Abstract:
:We reviewed the treatment and results of 22 Bennett's fractures. Of these fractures, treated by closed reduction and plaster immobilization, 20 were available for follow-up. Eighteen patients had a subjectively satisfactory outcome, and seven had a radiographically confirmed arthrosis of the first carpometacarpal joint. Of these, two were severe and painfully impaired. Nonanatomic reduction was seen in six of the seven patients with arthrosis and is thus considered a prognostic factor of posttraumatic arthrosis.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Oosterbos CJ,de Boer HHdoi
10.1097/00005131-199502000-00004subject
Has Abstractpub_date
1995-02-01 00:00:00pages
23-7issue
1eissn
0890-5339issn
1531-2291journal_volume
9pub_type
杂志文章abstract:OBJECTIVE:Does immediate tibial nail insertion without reaming as part of protocol-driven management provide a safe and effective treatment for open tibia fractures? STUDY DESIGN:Prospective cohort. SETTING:Level 1 trauma center. PATIENTS:A consecutive series of 161 patients with Gustilo grade I-IIIb open tibia frac...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3180336923
更新日期:2007-03-01 00:00:00
abstract::Fracture healing is a unique multifaceted process requiring the presence of cells, molecular mediators, and angiogenic factors. The state of inflammation dominates the initial phase, but the ideal magnitude and duration of the process for an optimal outcome remains obscure. Biological response modifiers, such as plate...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000465
更新日期:2015-12-01 00:00:00
abstract::The maximum pullout force in the distal metaphysis of cadaver femurs was investigated using a commercially available, pneumatically inserted staple. In paired studies, a significantly greater pullout force was required in the power-driven staples than in an almost identical sized hand-driven staple. A nonlinear relati...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199004020-00009
更新日期:1990-01-01 00:00:00
abstract::The application of a pelvic clamp for provisional stability of unstable pelvic fractures has been advocated in the orthopaedic literature. Although the technique has gained some supporters, problems with placement and associated complications have prevented widespread acceptance. We have modified the pelvic clamp (ACE...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000175156.92743.db
更新日期:2006-01-01 00:00:00
abstract:OBJECTIVES:To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN:Retrospective. SETTING:Urban University Level I Trauma Center. PATIENT/PARTICIPANTS:All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were re...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000391
更新日期:2016-01-01 00:00:00
abstract::The distribution of clindamycin in tibial cortical bone, administered via direct local infusion with an implantable pump, is described. Clindamycin concentrations in cortical bone were measured after 3, 7, and 21 days of intraosseous infusion. The tibia were divided into four quadrants relative to the outflow infusion...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199410000-00003
更新日期:1994-10-01 00:00:00
abstract:OBJECTIVES:To determine the rates of infection in low-energy gunshot wounds (GSWs) to the extremity. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:Patients (N = 140) with at least 90-day follow-up for extremity-only low-energy GSW injuries from 2010-2014 were retrospectively revie...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000827
更新日期:2017-06-01 00:00:00
abstract::Fifteen patients with fractures of the extremities and associated arterial injuries treated from 1976 to 1987 were retrospectively analyzed. Complete ischemia was present in only two cases; in four cases with partial ischemia, the vascular injury presented late after 12 h-14 days. All limbs could be preserved, but com...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199103000-00005
更新日期:1991-01-01 00:00:00
abstract::From 1998 to 2006, 578 patients who were skeletally immature with proximal humerus fractures were treated at our institution. During that time period, 4 patients (0.7%) had associated brachial plexus and major peripheral nerve palsies. Average age at the time of injury was 12.3 years (range 10-14 years). Two fractures...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31816b7898
更新日期:2008-04-01 00:00:00
abstract::Over a 15-month period, 41 open grade I-IIIA tibia fractures were treated with unreamed interlocking nails. A protocol previously established by the authors to enhance fracture union was followed. The purpose of the study was to determine if union rate for the comminuted statically locked fracture could be reduced thr...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199504000-00005
更新日期:1995-04-01 00:00:00
abstract::We present a case of a 19-year-old woman with a closed diaphyseal femur fracture and who had fixation of the fracture using a newer lateral entry nail, which resulted in an intraoperative proximal femur fracture. The patient underwent revision the following day and subsequently returned to regular activity without sig...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181a53790
更新日期:2010-04-01 00:00:00
abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318051532d
更新日期:2007-05-01 00:00:00
abstract:OBJECTIVES:To compare reports of implant fatigue failure submitted to the FDA of 2 commonly used cephalomedullary nails. METHODS:In total, 2724 medical device reports from the FDA's MAUDE database from Jan 2015 to Oct 2019 were reviewed for the Trochanteric Femoral Nail-Advanced (TFNa) and Gamma 3 implants. RESULTS:D...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001864
更新日期:2021-02-01 00:00:00
abstract::In our search for an osteosynthesis device that would tolerate the surgical errors of the inexperienced surgeon, we tested in vitro femoral stiffness in 75 human osteoporotic femora after internal fixation of a cervical neck osteotomy using three commonly used devices: two von Bahr screws (A. Ericsson AB, Sweden), two...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199608000-00009
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVE:To characterize the presentation and outcomes of calcaneal avulsion fractures. DESIGN:Case series. SETTING:Two ACS Level I trauma centers. PATIENTS/PARTICIPANTS:Forty-seven calcaneal avulsion fractures isolated from a cohort of 1365 calcaneus fractures treated over a 17-year period. MAIN OUTCOME MEASUREME...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,多中心研究
doi:10.1097/BOT.0000000000001582
更新日期:2019-11-01 00:00:00
abstract::Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation s...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e31817d5356
更新日期:2008-08-01 00:00:00
abstract::This report describes the use of articulating external fixation in patients with lower extremity trauma with segmental nerve defects. Four patients who would otherwise require nerve grafting underwent application of an articulated external fixator, allowing optimal positioning for end-to-end, tension-free nerve repair...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200304000-00008
更新日期:2003-04-01 00:00:00
abstract:OBJECTIVES:To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS:Comminuted osteotomies were created in 10 matched pairs of cadaveric uppe...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001279
更新日期:2018-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the clinical use of the Partridge osteosynthesis in periprosthetic femoral fractures. DESIGN AND SETTING:Prospective nonrandomized clinical study. PATIENTS:Over a ten-year period, 222 patients presenting with femoral fractures near the tip of a hip prosthesis were treated with the Partridge syst...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章
doi:10.1097/00005131-200101000-00011
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVE:To evaluate objectively the effectiveness of current surgical management of displaced acetabular fractures. To provide insight into how these evaluation methods can be used to identify areas in which improvements in surgery and rehabilitation can be pursued to improve patient outcomes. DESIGN:Consecutive cas...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200202000-00001
更新日期:2002-02-01 00:00:00
abstract::Bone grafts are the second most common tissue transplanted in the United States, and they are an essential treatment tool in the field of acute and reconstructive traumatic orthopaedic surgery. Available in cancellous, cortical, or bone marrow aspirate form, autogenous bone graft is regarded as the gold standard in th...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001420
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:We investigated the role of negative pressure therapy (NPT) in postoperative primary wound treatment and closure. To date, extensive evidence exists demonstrating the benefit of negative pressure dressings in the treatment of open wounds; our experiment tested the hypothesis that negative pressure dressings ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318211363a
更新日期:2011-12-01 00:00:00
abstract:BACKGROUND:Although there is general agreement as to the pathophysiology and treatment of compartment syndrome and the importance of intramuscular pressure measurements, there are many methods described to obtain these measurements. Variations in experimental measurements using current electronic monitoring, needle, an...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31822908cf
更新日期:2012-01-01 00:00:00
abstract::Healing patterns were compared between transverse and 60 degrees oblique osteotomies in canine tibiae stabilized under external fixation. Under similar in vitro testing conditions (osteotomy ends in contact), the axial stiffness of the oblique osteotomy under external fixation was 45% of the paired transverse osteotom...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199109000-00016
更新日期:1991-01-01 00:00:00
abstract:PURPOSE:The purpose of this video is to demonstrate the technique of an extensile fasciotomy of the forearm and hand. METHODS:A patient presented to our hospital with a rapidly progressing infection of the right upper extremity and clinical signs and symptoms of compartment syndrome. The patient was immediately taken ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000903
更新日期:2017-08-01 00:00:00
abstract:OBJECTIVES:To analyze long-term functional outcomes in patients with posttraumatic infected tibial nonunions having undergone bone transport with hexapod external fixator. DESIGN:Retrospective cohort study. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:Thirty-eight patients with infected nonunions of the tibi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001005
更新日期:2018-01-01 00:00:00
abstract::Understanding complex acetabular fractures is difficult and may require three-dimensional reformatted computed tomographic (CT) images. This paper evaluates a technique, digital rotational imaging (DRI), that displays multiple oblique images of the pelvis and acetabulum. When viewed statically, DRI provides optimal il...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199801000-00011
更新日期:1998-01-01 00:00:00
abstract::The application of the pelvic clamp as a tool for emergency stabilization of unstable pelvic ring fractures has proved to be a life-saving procedure. Using correct technique, the pelvic clamp can be applied within a few minutes after the patient's admission. To avoid severe complications (eg, pin perforation into the ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200402000-00008
更新日期:2004-02-01 00:00:00
abstract::In patients who are candidates for a total knee arthroplasty and suffer a periarticular fracture of the femur, the arthroplasty may be performed after bony union of the fracture or immediately, in conjunction with the fracture repair. Herein we present the case of a sixty-year-old female with rheumatoid arthritis and ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199906000-00014
更新日期:1999-06-01 00:00:00
abstract:OBJECTIVE:To determine whether operating on "major" vertebral fractures leads to premature abortion of surgery and/or other acute cardiopulmonary complications. DESIGN:Retrospective review. CLINICAL SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS AND INTERVENTION:We retrospectively queried our institutional Tra...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001316
更新日期:2019-01-01 00:00:00