The reliability of measurement of tissue pressure in compartment syndrome.

Abstract:

BACKGROUND:Although there is general agreement as to the pathophysiology and treatment of compartment syndrome and the importance of intramuscular pressure measurements, there are many methods described to obtain these measurements. Variations in experimental measurements using current electronic monitoring, needle, and catheter devices of 18 to 22 mmHg are reported and are enough to cause errors in clinical decision-making that could result in significant clinical consequences. Current unacceptable reliability has been reported with the use of bevel-tipped needles and the clinical Whitesides technique. Because this is contrary to the authors' cumulative clinical and research experience with various methods when properly used (with the small required saline flush to assure a fluid continuum between tissue and the pressure monitor), this study was designed to clarify these problems. Although the two Whitesides techniques (original and clinical) are not in current use where digital methods are available, the clinical method is still used in the Third World. METHODS:To eliminate comparative errors, a laboratory compartment syndrome model was devised to allow simultaneous testing of different devices in the same area of fusiform muscle against increasing intramuscular pressure using the same transducer and monitor. Slit catheters, side-ported bevel-tipped needles, and 18-gauge bevel-tipped needles were compared against each other. The two Whitesides methods using a capillary meniscus and a mercury manometer were compared against a current electronic transducer method using identical 18-gauge bevel-tipped needles and varying diameter capillary tubing. RESULTS:The side-ported needle, slit catheter, and 18-gauge bevel-tipped needle were found to measure equivalent pressure when compared statistically with each other in pairs. The original Whitesides method using a 1.25-mm capillary tube and the digital transducer method using 18-gauge bevel-tipped needles was also found to measure equivalent pressure. The clinical Whitesides method using current plastic intravenous tubing of 3.0-mm internal diameter fails to produce an obvious capillary meniscus, leading to diminished reliability in the measured pressure. CONCLUSIONS:The slit catheter, side-ported bevel-tipped needle, or an 18-gauge needle, when appropriately used with current electronic transducer monitoring, may be used clinically with confidence. When digital methods are not available, the original Whitesides method using 1.25-mm glass capillary tubing is an accurate alternative but requires preplanning. When only 3-mm tubing is available, this method is relatively useful when electronic means are not available by averaging several consecutive measurements.

journal_name

J Orthop Trauma

authors

Hammerberg EM,Whitesides TE Jr,Seiler JG 3rd

doi

10.1097/BOT.0b013e31822908cf

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

24-31; discussion 32

issue

1

eissn

0890-5339

issn

1531-2291

journal_volume

26

pub_type

杂志文章
  • In vitro femoral stiffness after femoral neck osteotomy and osteosynthesis with defined surgical errors.

    abstract::In our search for an osteosynthesis device that would tolerate the surgical errors of the inexperienced surgeon, we tested in vitro femoral stiffness in 75 human osteoporotic femora after internal fixation of a cervical neck osteotomy using three commonly used devices: two von Bahr screws (A. Ericsson AB, Sweden), two...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199608000-00009

    authors: Hernefalk L,Messner K

    更新日期:1996-01-01 00:00:00

  • Prolonged thromboprophylaxis with dalteparin after surgical treatment of achilles tendon rupture: a randomized, placebo-controlled study.

    abstract:OBJECTIVES:Prophylaxis against thromboembolic complications has become routine after major orthopedic surgery. In contrast, it remains an issue for debate whether prophylaxis after minor surgery and immobilization is necessary, even though these treatments are well-known risk factors for deep-vein thrombosis (DVT). The...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/01.bot.0000250741.65003.14

    authors: Lapidus LJ,Rosfors S,Ponzer S,Levander C,Elvin A,Lärfars G,de Bri E

    更新日期:2007-01-01 00:00:00

  • Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

    abstract:OBJECTIVE:To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. METHODS:Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000309

    authors: Wurm S,Augat P,Bühren V

    更新日期:2015-09-01 00:00:00

  • Trauma program development.

    abstract::The development of a strong trauma program is clearly one of the most important facets of successful business development. Several recent publications have demonstrated that well run trauma services can generate significant profits for both the hospital and the surgeons involved. There are many aspects to this task th...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000142

    authors: Althausen PL

    更新日期:2014-07-01 00:00:00

  • Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures.

    abstract:OBJECTIVE:To evaluate the clinical use of the Partridge osteosynthesis in periprosthetic femoral fractures. DESIGN AND SETTING:Prospective nonrandomized clinical study. PATIENTS:Over a ten-year period, 222 patients presenting with femoral fractures near the tip of a hip prosthesis were treated with the Partridge syst...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/00005131-200101000-00011

    authors: de Ridder VA,de Lange S,Koomen AR,Heatley FW

    更新日期:2001-01-01 00:00:00

  • Modified Technique of Separate Vertical Wiring for the Fixation of Patellar Inferior Pole Fracture.

    abstract::To evaluate the biomechanical and clinical results of modified separate vertical wiring technique (SVW) for inferior pole patellar fracture repair we conducted a finite element biomechanical study using 2 fixation methods and evaluated a clinical series of eleven patients. The modified SVW technique was an effective, ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001080

    authors: He S,Huang X,Yan B,Zhu J,Bao N,Zhao J

    更新日期:2018-04-01 00:00:00

  • No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures.

    abstract:OBJECTIVE:To determine whether stimulation with low-intensity ultrasound will reduce the radiologic healing time of fresh tibial shaft fractures fixed with a reamed and statically locked intramedullary rod. DESIGN:Prospective, randomized, double blinded, and placebo controlled. PATIENTS AND METHODS:Thirty-two adult p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199905000-00005

    authors: Emami A,Petrén-Mallmin M,Larsson S

    更新日期:1999-05-01 00:00:00

  • Functional outcomes in women after high-energy pelvic ring injury.

    abstract:OBJECTIVES:Residual dysfunction after pelvic trauma has been previously described, but limited functional outcome data are available in the female population after high-energy pelvic ring injury. The purposes of this study were to determine functional outcomes and to characterize factors predictive of outcome. DESIGN:...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318221e94e

    authors: Vallier HA,Cureton BA,Schubeck D,Wang XF

    更新日期:2012-05-01 00:00:00

  • Cross-sectional geometry of the sacral ala for safe insertion of iliosacral lag screws: a computed tomography model.

    abstract:OBJECTIVE:To measure the dimensions of the narrowest portion of the sacral ala for safe insertion of iliosacral lag screws. DESIGN:Computed tomography (CT) model. SETTING:Level One trauma center. PATIENTS:Thirteen adult patients underwent pelvic CT imaging. MAIN OUTCOME MEASURE:Axial CT scans of intact pelves were ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200001000-00007

    authors: Noojin FK,Malkani AL,Haikal L,Lundquist C,Voor MJ

    更新日期:2000-01-01 00:00:00

  • Regeneration of segmental diaphyseal defects in sheep tibiae using resorbable polymeric membranes: a preliminary study.

    abstract:OBJECTIVE:To investigate whether a long bone cortex of well-defined thickness can be regenerated by using an anatomically designed membranous resorbable "tube-in-tube" implant and to establish the functions of membranes in the healing of segmental diaphyseal bone defects larger than the "critical size." DESIGN:Bone he...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199903000-00006

    authors: Gugala Z,Gogolewski S

    更新日期:1999-03-01 00:00:00

  • Physical Performance Limitations After Severe Lower Extremity Trauma in Military Service Members.

    abstract:OBJECTIVES:To characterize the type and magnitude of lower extremity physical performance deficits in military service members who have undergone rehabilitation after limb salvage or transtibial amputation. DESIGN:Cross-sectional prospective. SETTING:Level I trauma military medical and rehabilitation center. PATIENT...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001103

    authors: Wilken JM,Roy CW,Shaffer SW,Patzkowski JC,Blanck RV,Owens JG,Hsu JR

    更新日期:2018-04-01 00:00:00

  • False positive indium-111 white blood cell scan in a closed clavicle fracture.

    abstract::Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagn...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Friedman RJ,Gordon L

    更新日期:1988-01-01 00:00:00

  • Stabilization of displaced articular fragments in calcaneal fractures using bioabsorbable pin fixation: a technique guide.

    abstract::Successful operative intervention in displaced intra-articular calcaneal fractures depends in part on the maintenance of an anatomic reduction of the posterior facet. This guide describes our use of bioabsorbable implants to solve this problem. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ca38ce

    authors: Min W,Munro M,Sanders R

    更新日期:2010-12-01 00:00:00

  • Isolated ulnar shaft fractures treated with functional braces.

    abstract:OBJECTIVE:To report the results from functional bracing of isolated ulnar shaft fractures. DESIGN:Retrospective review. SETTING:Two university hospitals. PATIENTS:Isolated ulnar shaft fractures in 444 patients were stabilized in functional braces that permitted full range of motion of all joints. INTERVENTION:Prefa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199808000-00009

    authors: Sarmiento A,Latta LL,Zych G,McKeever P,Zagorski JP

    更新日期:1998-08-01 00:00:00

  • Complications of nailing in closed tibial fractures.

    abstract::Reamed intramedullary nailing was used to treat 102 closed tibial shaft fractures. Although a high rate of union was achieved (98%), we noted a higher incidence of complications than previously reported. Thirty-five (37%) patients exhibited one or more components of malunion. In 17 (18%) patients, further operative pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199509060-00004

    authors: Williams J,Gibbons M,Trundle H,Murray D,Worlock P

    更新日期:1995-01-01 00:00:00

  • The "swashbuckler": a modified anterior approach for fractures of the distal femur.

    abstract::A modified anterior approach to the distal femur is presented. The approach allows surgical exposure of the entire articular surface of the distal femur. The quadriceps muscle bellies are spared during the approach. The skin incision used will not interfere with subsequent total knee arthroplasty, if posttraumatic art...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199902000-00012

    authors: Starr AJ,Jones AL,Reinert CM

    更新日期:1999-02-01 00:00:00

  • Radiographic analysis of the Brooker-Wills interlocking nail in the treatment of comminuted femoral fractures.

    abstract::Forty-three patients with 43 comminuted femoral shaft fractures treated with the Brooker-Wills interlocking nail were followed through bony union to determine the device's ability to maintain length and rotational control of these difficult injuries. Only severely comminuted fractures, types III and IV, were included....

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-198702010-00002

    authors: Brumback RJ,Handal JA,Poka A,Burgess AR,Feddis G

    更新日期:1987-01-01 00:00:00

  • Definitive Management of Distal Tibia and Simple Plafond Fractures With Circular External Fixation.

    abstract::Obtaining optimal results in the treatment of extraarticular distal tibia fractures can be challenging. Plate and screw and intramedullary fixation have proven to be effective treatments, but are associated with significant complication rates when used for open fractures and patient with severe medical comorbidities. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000694

    authors: Quinnan SM

    更新日期:2016-11-01 00:00:00

  • Comparison of Early Fatigue Failure of the TFNa and Gamma 3 Cephalomedullary Nails in the United States From 2015 to 2019.

    abstract:OBJECTIVES:To compare reports of implant fatigue failure submitted to the FDA of 2 commonly used cephalomedullary nails. METHODS:In total, 2724 medical device reports from the FDA's MAUDE database from Jan 2015 to Oct 2019 were reviewed for the Trochanteric Femoral Nail-Advanced (TFNa) and Gamma 3 implants. RESULTS:D...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001864

    authors: Klima ML

    更新日期:2021-02-01 00:00:00

  • Three-dimensional computerized tomographic demonstration of bilateral atlantoaxial rotatory dislocation in an adult: report of a case and review of the literature.

    abstract::A rare case of bilateral atlantoaxial rotatory dislocation (Fielding type V) in an adult is presented. The diagnosis was rapidly made by computed axial tomography. Prior reports of this entity have not clearly defined the pathoanatomy, which in our case was confirmed by three-dimensional tomographic reconstruction. We...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-199402000-00015

    authors: Born CT,Mure AJ,Iannacone WM,DeLong WG Jr

    更新日期:1994-01-01 00:00:00

  • Retrograde Femoral Nailing Using Percutaneous Reduction Techniques.

    abstract::Femoral shaft fractures are commonly treated with closed reduction and reamed intramedullary nailing. However, some reductions are difficult to obtain or maintain, especially in muscular or large patients. When closed methods fail to achieve reduction, percutaneous techniques are extremely useful. In addition, the use...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000890

    authors: Pettett BJ,Avery MC,Ostrum RF

    更新日期:2017-08-01 00:00:00

  • Single provider reduction and splinting of displaced ankle fractures: a modification of Quigley's classic technique.

    abstract::Ankle fractures are commonly treated by orthopaedic surgeons and often require manipulative reduction. This can be painful for the patient and frequently uses 2 or more providers. Intra-articular injection of local anesthetic into the ankle joint precludes the need for conscious sedation (intravenous narcotics and ben...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000206

    authors: Alton TB,Harnden E,Hagen J,Firoozabadi R

    更新日期:2015-04-01 00:00:00

  • The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression.

    abstract:OBJECTIVE:A new device for the treatment of intertrochanteric fractures that uses 2 cephalocervical screws in an integrated mechanism allowing linear intraoperative compression and rotational stability of the head/neck fragment has been developed. The aim of this study was to describe the results using this device for ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0b013e31819211b2

    authors: Ruecker AH,Rupprecht M,Gruber M,Gebauer M,Barvencik F,Briem D,Rueger JM

    更新日期:2009-01-01 00:00:00

  • A Novel Traction Frame for Femur Fracture Management in Developing Countries: Technique and Outcomes.

    abstract::Fractures of the femur have long been a major cause of morbidity and mortality in developing countries and are most frequently caused by road traffic accidents. Intramedullary nail fixation has become the gold standard of care for diaphyseal fractures of the femur. However, modern techniques require proper implants, a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001407

    authors: Levy DM,Meadows MC,Gates DJ

    更新日期:2019-05-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • Innominosacral dissociation: mechanism of injury as a predictor of resuscitation requirements, morbidity, and mortality.

    abstract:OBJECTIVES:To assess mechanism of injury as a clinical course predictor in patients with complete anterior and posterior pelvic ring disruptions [innominosacral dissociation (ISD)]. DESIGN:Retrospective review of radiographs and medical data. SETTING:R Adams Cowley Shock Trauma Center, Baltimore, Maryland, statewide ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199702000-00002

    authors: Whitbeck MG Jr,Zwally HJ 2nd,Burgess AR

    更新日期:1997-02-01 00:00:00

  • Continuous peripheral nerve blockade as postoperative analgesia for open treatment of calcaneal fractures.

    abstract:OBJECTIVE:To examine the cost and efficacy of methods of general and regional anesthetic for postoperative pain control after open repair of intra-articular calcaneal fractures. We compared single-injection popliteal fossa blocks and continuous infusion popliteal fossa blocks with drug delivered through a catheter from...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181bfc9f7

    authors: Hunt KJ,Higgins TF,Carlston CV,Swenson JR,McEachern JE,Beals TC

    更新日期:2010-03-01 00:00:00

  • A staged protocol for soft tissue management in the treatment of complex pilon fractures.

    abstract:OBJECTIVE:To determine whether open reduction and internal fixation of intra-articular pilon fractures using a staged treatment protocol results in minimal surgical wound complications. DESIGN:Retrospective. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:Between January 1991 and December 1996, 226 pilon fractu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199902000-00002

    authors: Sirkin M,Sanders R,DiPasquale T,Herscovici D Jr

    更新日期:1999-02-01 00:00:00

  • Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail.

    abstract:OBJECTIVES:To compare the results between a new intramedullary Gamma nail and a compression hip screw in the treatment of trochanteric fractures. DESIGN:Prospective randomized. SETTING:Level 1 trauma center. PATIENTS:Two hundred ten consecutive patients older than 65 years with trochanteric femoral fractures. INTER...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.bot.0000151819.95075.ad

    authors: Utrilla AL,Reig JS,Muñoz FM,Tufanisco CB

    更新日期:2005-04-01 00:00:00

  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00