Abstract:
:Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Friedman RJ,Gordon Lsubject
Has Abstractpub_date
1988-01-01 00:00:00pages
151-3issue
2eissn
0890-5339issn
1531-2291journal_volume
2pub_type
杂志文章abstract::Prospectively, 40 patients with an average age of 45 (20-65) with closed transverse fractures of the middle one-third of the humerus without associated radial nerve palsy were treated. All had failed nonoperative reduction and were then operated on with either compression plating or intramedullary fixation with Hacket...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00005131-199506000-00003
更新日期:1995-06-01 00:00:00
abstract::We report an isolated anterior dislocation of the radial head in an adult after sustaining a fall on the outstretched arm. Based on history and presentation, we speculate that the injury occurred in a position of hyperextension and supination. Reduction was achieved by a pronation maneuver. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199505000-00014
更新日期:1995-01-01 00:00:00
abstract:OBJECTIVES:Biomechanical studies of osteoporotic bone have used synthetic models rather than cadaveric samples because of decreased variability, increased availability, and overall ease of the use of synthetic models. We compared the torsional mechanical properties of cadaveric osteoporotic bone with those of currently...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000782
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVES:To investigate whether a conventional fracture hematoma block (FHB) or an ultrasound-guided peripheral nerve block has more superior analgesic effect during nonoperative management of distal radius fractures in an emergency department setting. Two peripheral nerve block types were investigated, one at the le...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,随机对照试验
doi:10.1097/BOT.0000000000001388
更新日期:2019-04-01 00:00:00
abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318051532d
更新日期:2007-05-01 00:00:00
abstract::Fractures of the distal humerus involving the articular surface can be challenging. The complexity of these fracture patterns increases when the distal fracture is associated with a concomitant humeral shaft fracture with significant proximal extension. The combined exposure technique described here allows for consist...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000245988.23684.79
更新日期:2007-02-01 00:00:00
abstract:OBJECTIVE:This study was designed to investigate the specific type and incidence of implant failure in patients with a proximal femur fracture treated with a proximal femoral nail antirotation. This device has a helical-shaped blade as a neck-head holding device, instead of the lag screw used in other intramedullary na...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31822c53c1
更新日期:2012-08-01 00:00:00
abstract::A 14 cm deficit of the tibia with a soft tissue deficit was resolved using the apparatus of Ilizarov. The apparatus was applied using a double corticotomy of the proximal and distal remainder of the tibia. The fragments were moved until they met each other in the central part of the deficit. Afterwards, a part of the ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract:OBJECTIVES:Long bone fractures that fail to heal or show a delay in healing can lead to increased morbidity. Bone marrow aspirate concentrate (BMAC) containing bone mesenchymal stem cells (BMSCs) has been suggested as an autologous biologic adjunct to aid long bone healing. The purpose of this study was to systematical...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000453
更新日期:2016-01-01 00:00:00
abstract::The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and ar...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e318288c0c3
更新日期:2014-01-01 00:00:00
abstract::The best results following fractures of the distal humerus are provided by anatomic reduction and rigid internal fixation. Plates of two designs placed in five different fixation configurations were used to determine the construct that would maximize rigidity of fixation of the distal humerus. Using a cadaver distal h...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:
更新日期:1994-12-01 00:00:00
abstract:OBJECTIVES:Malalignment has been frequently reported after intramedullary stabilization of distal tibia fractures. Nails have also been associated with knee pain in several studies. Historically, plate fixation has resulted in increased risks of infection and nonunion. Our purposes were to compare plate and nail stabil...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,随机对照试验
doi:10.1097/BOT.0b013e318213f709
更新日期:2011-12-01 00:00:00
abstract::Studies in several countries have indicated that there is likely to be a dramatic increase in the number of hip fractures in the early part of the 21st century. At a time when health care costs are coming under close scrutiny internationally, the added financial burden of the increasing number of fractures is of conce...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract::The maximum pullout force in the distal metaphysis of cadaver femurs was investigated using a commercially available, pneumatically inserted staple. In paired studies, a significantly greater pullout force was required in the power-driven staples than in an almost identical sized hand-driven staple. A nonlinear relati...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199004020-00009
更新日期:1990-01-01 00:00:00
abstract::This technique article presents a small-incision, gluteal-splitting approach for the treatment of select fractures involving the posterior acetabulum. The approach essentially involves the proximal portion of the Kocher-Langenbeck incision, and it can be extended to a larger exposure if needed. It is ideally suited fo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000211143.70424.f7
更新日期:2006-09-01 00:00:00
abstract::The application of a pelvic clamp for provisional stability of unstable pelvic fractures has been advocated in the orthopaedic literature. Although the technique has gained some supporters, problems with placement and associated complications have prevented widespread acceptance. We have modified the pelvic clamp (ACE...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000175156.92743.db
更新日期:2006-01-01 00:00:00
abstract:OBJECTIVES:The aim of this article is to provide a concise review of the basic science of extracorporeal shock wave therapy (ESWT) and to perform a systematic review of the literature for the use of ESWT in the treatment of fractures and delayed unions/nonunions. DATA SOURCES:Articles in the English or German language...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,meta分析,评审
doi:10.1097/BOT.0b013e3181cad510
更新日期:2010-03-01 00:00:00
abstract::Thirty-five patients with four-part displaced proximal humeral fractures and fracture-dislocations were retrospectively reviewed from the years 1977-1990. Thirty-three patients were available for study. All fractures were treated by open reduction and internal fixation allowing early motion. Surgical technique was as ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199312000-00002
更新日期:1993-01-01 00:00:00
abstract:OBJECTIVE:To determine the effects of various suture patterns on cutaneous blood flow (CBF) at the wound edge as increasing tension is applied through the suture. METHODS:Four different suture patterns commonly used for wound closure (simple, vertical mattress, horizontal mattress, and Allgower-Donati) were placed ind...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318169074c
更新日期:2008-03-01 00:00:00
abstract:OBJECTIVES:To compare the accuracy of 5 commonly available fine wire tensioners used in hybrid and ring external fixation. DESIGN:A laboratory investigation. SETTING:The testing of 5 commonly available tensioners was performed with a servohydraulic test frame (MTS Bionix 858, Minneapolis, MN). MAIN OUTCOME MEASUREME...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200403000-00006
更新日期:2004-03-01 00:00:00
abstract:PURPOSE:Radial head fractures are some of the most common elbow fractures. Fractures with 3 or more fracture fragments have been shown to have worse outcomes when treated with open reduction and internal fixation (ORIF). Radial head replacement offers an alternative treatment for those more comminuted radial head fract...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001537
更新日期:2019-08-01 00:00:00
abstract::Seat belt legislation has resulted in increased restraint use by passengers in automobiles in Washington State. At Harborview Medical Center in Seattle, we have observed an increased incidence of seat belt-related injuries. Twenty cases of Chance-type thoracolumbar flexion-distraction fractures were reviewed retrospec...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199105020-00006
更新日期:1991-01-01 00:00:00
abstract::Fracture compression can be achieved in many ways intraoperatively using either screws in compression plates, compression devices, or using intramedullary nails. The use of locked intramedullary nails combines the advantages of indirect fracture fixation and compression with minimal soft tissue disruption. This articl...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e31819f2779
更新日期:2009-05-01 00:00:00
abstract::A modified freehand method using a cannulated drill bit for the insertion of distal locking screws for interlocking intramedullary nails is described. It should be useful to introduce surgeons to interlocking and to aid those who are not comfortable with the freehand method. ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199306000-00009
更新日期:1993-01-01 00:00:00
abstract::Minifragment implants provide several advantages for the stabilization of distal humerus fractures. Compared with small fragment implants, minifragment implants may provide enhanced fracture fixation because a greater number of screws can be placed into the distal fragments. In addition, minifragment plates are easier...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000157908.45939.d7
更新日期:2005-08-01 00:00:00
abstract::Monteggia fractures represent approximately 1 to 2 percent of forearm fractures, whereas Galeazzi fractures represent 3 to 6 percent. The combination of these injuries in the same extremity is an exceedingly rare occurrence. We report a case of ipsilateral combination Monteggia and Galeazzi fractures in an adult patie...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200202000-00011
更新日期:2002-02-01 00:00:00
abstract::Ipsilateral femoral shaft and tibial plateau fractures, termed a "floating knee" are rare and challenging injuries. There is limited literature guiding the operative technique and the outcomes associated with these injuries. The author's preferred technique is early intramedullary of the femoral shaft fracture with kn...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001944
更新日期:2020-09-01 00:00:00
abstract:OBJECTIVE:The open reduction and internal fixation of radial shaft fractures and osteotomies with standard 3.5-mm plates can be complicated by tendon irritation, hardware prominence, and fracture through the screw holes. With the advent of locking plate technology, implant companies and some surgeons have recommended e...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181f8bf9b
更新日期:2011-06-01 00:00:00
abstract:OBJECTIVE:To evaluate the experience of a single tertiary care teaching hospital with the association between use of bisphosphonates and atypical femoral fractures, and to identify potential risk factors and chronologic incidence. DESIGN:Retrospective review. SETTING:Tertiary-care teaching hospital. PATIENTS:Thirty-...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000539
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to evaluate donor site morbidity associated with anterior iliac crest bone graft harvesting for orthopaedic trauma reconstructions. DESIGN:Retrospective case series. SETTING:Level 1 trauma center. PATIENTS:Forty-Six consecutive patients who had undergone anterior iliac cres...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000551
更新日期:2016-06-01 00:00:00