Abstract:
:The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Yi C,Burns S,Hak DJdoi
10.1097/BOT.0b013e318288c0c3subject
Has Abstractpub_date
2014-01-01 00:00:00pages
48-56issue
1eissn
0890-5339issn
1531-2291journal_volume
28pub_type
杂志文章,评审abstract::Our purpose was to determine the incidence of deep-vein thrombosis (DVT) in patients who have had early operative fixation of fractures of the lower extremity distal to the hip. There is a high incidence of distal thrombosis in patients who have undergone early operative fixation of lower-extremity fractures. The inci...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199605000-00002
更新日期:1996-01-01 00:00:00
abstract::Periprosthetic humerus fractures are relatively uncommon occurrence that can be difficult to manage nonoperatively. Locking plate technology has enhanced the surgical management of these fractures. However, adequate fixation around the stem remains of some concern. We describe an osteosynthesis technique using a locki...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000646
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVES:To assess the outcomes of the surgical management of "isolated" displaced lateral malleolar fractures, comparing the techniques of lateral plating and antiglide plating as described previously. DESIGN:This is a retrospective review, being largely a surgeon-randomized comparative study. SETTING:The study wa...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200208000-00008
更新日期:2002-08-01 00:00:00
abstract::In our search for an osteosynthesis device that would tolerate the surgical errors of the inexperienced surgeon, we tested in vitro femoral stiffness in 75 human osteoporotic femora after internal fixation of a cervical neck osteotomy using three commonly used devices: two von Bahr screws (A. Ericsson AB, Sweden), two...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199608000-00009
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVE:To review our series of open calcaneal fractures compared with other series. DESIGN:Retrospective review. SETTING:All patients were treated at a single Level 1 trauma center. PATIENTS/PARTICIPANTS:We reviewed 19 consecutive patients, each with an open fracture of the calcaneus. Fracture morphology ranged f...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200401000-00002
更新日期:2004-01-01 00:00:00
abstract:OBJECTIVE:To determine if cancellous screw (CS) and sliding hip screw (SHS) technical factors during low-energy femoral neck fracture fixation affects a 24-month revision surgery rate and health-related quality of life (HRQL). DESIGN:Prospective randomized controlled study. SETTING:International, multicenter. PATIEN...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001891
更新日期:2021-02-01 00:00:00
abstract::Posterior wall (PW) fractures are the most common fractures requiring surgical fixation in acetabular surgery. Extra-articular screw placement must be confirmed intraoperatively. Herein we describe the use of the inlet and obturator oblique view (the Leeds view) for screw placement in elementary PW and in associated b...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章
doi:10.1097/BOT.0000000000000724
更新日期:2017-04-01 00:00:00
abstract:OBJECTIVES:Prophylaxis against thromboembolic complications has become routine after major orthopedic surgery. In contrast, it remains an issue for debate whether prophylaxis after minor surgery and immobilization is necessary, even though these treatments are well-known risk factors for deep-vein thrombosis (DVT). The...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,随机对照试验
doi:10.1097/01.bot.0000250741.65003.14
更新日期:2007-01-01 00:00:00
abstract:OBJECTIVE:A new device for the treatment of intertrochanteric fractures that uses 2 cephalocervical screws in an integrated mechanism allowing linear intraoperative compression and rotational stability of the head/neck fragment has been developed. The aim of this study was to describe the results using this device for ...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章
doi:10.1097/BOT.0b013e31819211b2
更新日期:2009-01-01 00:00:00
abstract:OBJECTIVES:The purposes of this study were to evaluate the cantilevered bending strength and failure modes of locking screws inserted at various angles in a plate with fully circumferential threaded holes. As an additional measure, the amount of screw head prominence at these angles was also assessed. METHODS:Standard...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000066
更新日期:2014-01-01 00:00:00
abstract::Road traffic accidents are a leading cause of global mortality. In March 2010, the United Nations General Assembly and the World Health Organization (WHO) officially proclaimed 2011-2020 as the "Decade of Action for Road Safety." Researchers must focus on vulnerable road users and low- and middle-income countries (LMI...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000103
更新日期:2014-01-01 00:00:00
abstract:OBJECTIVES:To determine whether uncemented implants would provide similar outcomes while avoiding the complications associated with cement in the treatment of elderly patients with proximal humerus fractures (PHFs) with primary reverse total shoulder arthroplasty (RTSA). DESIGN:Case series. SETTING:A single Level I t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001465
更新日期:2019-07-01 00:00:00
abstract::Fractures of the distal humerus involving the articular surface can be challenging. The complexity of these fracture patterns increases when the distal fracture is associated with a concomitant humeral shaft fracture with significant proximal extension. The combined exposure technique described here allows for consist...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/01.bot.0000245988.23684.79
更新日期:2007-02-01 00:00:00
abstract::Orthopaedic surgery and biomechanics are intimately partnered topics in medicine. Biomechanical principles are used to design implants and fashion treatment protocols. Although it would seem that biomechanical principles in the design of fixation devices and fracture repair constructs have been already finalized, ther...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000001126
更新日期:2018-03-01 00:00:00
abstract:OBJECTIVES:Evaluate the effect of the COVID-19 pandemic and the "shelter-in-place" order on orthopaedic trauma presenting to a community level II trauma center. It is hypothesized the overall number of orthopaedic trauma encounters (OTE), the number of OTEs related to both high and low severity injuries, as well as the...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001860
更新日期:2020-06-08 00:00:00
abstract:OBJECTIVE:To compare the strength of fixation obtained using two unicortical 4.0 mm diameter cancellous screws versus two bicortical 3.5 mm diameter cortical screws in the fixation of intra-articular calcaneus fractures. DESIGN:In eight paired fresh frozen cadaver feet, the subtalar joint complex, consisting of the ta...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199701000-00008
更新日期:1997-01-01 00:00:00
abstract::The pull-out strength of two types of bone staples (A, Techmedica; B, Richards) was evaluated in a canine model and compared with a control of 6.5 mm cancellous bone screw (Synthes). Fifteen adult mongrel dogs were divided into three groups of five animals each. The implants were placed in the lateral femoral condyle ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198701040-00009
更新日期:1987-01-01 00:00:00
abstract:OBJECTIVES:Lateral locked plating for proximal tibial fractures with metaphyseal disruption provides a biomechanically stable and biologically favorable alternative to conventional medial/lateral plate fixation. New polyaxial screw technology incorporates expanding screw bushings, allowing variable angle screw placemen...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/QAI.0b013e3181a25368
更新日期:2009-08-01 00:00:00
abstract:OBJECTIVES:For intramedullary nailing of tibial shaft fractures, a recent study has determined that the entry site should be just medial to the lateral tibial spine at the anterior margin of the articular surface. Gaining access to this site is often through a medial parapatellar or transpatellar approach. Several stud...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200211000-00001
更新日期:2002-11-01 00:00:00
abstract:OBJECTIVES:Because locked plates as a neutralization device for lag screw fracture fixation have different biomechanics than that of unlocked plates, we investigated how this would affect lag screw load at the fracture site. The purpose of this study was to assess the load at a fracture site compressed with a lag screw...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31823b3dd1
更新日期:2012-09-01 00:00:00
abstract:OBJECTIVE:To biomechanically assess the angular stability provided by 3 techniques for reconstruction of the lateral ulnar collateral ligament. METHODS:Eight cadaveric elbows were tested with the lateral collateral ligament complex intact, disrupted from the origin at the lateral epicondyle, and reconstructed with 3 d...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001051
更新日期:2018-03-01 00:00:00
abstract:OBJECTIVES:To investigate the clinical utility of additional axillary or Velpeau views in evaluating potential shoulder trauma after a standard radiograph series of anteroposterior, Grashey, and/or trans-scapular views. DESIGN:Retrospective study. SETTING:Level I academic medical center. PATIENTS:All patients in a 1...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001760
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVES:To evaluate the use of lag screw only fixation of noncomminuted oblique fractures of the lateral malleolus in patients younger than fifty years of age. DESIGN:Prospective evaluation. SETTING:Level I trauma center. PATIENTS AND PARTICIPANTS:Forty-seven ankle fractures with simple oblique patterns and no co...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200102000-00008
更新日期:2001-02-01 00:00:00
abstract::American survivability during the current conflicts in Iraq and Afghanistan continues to improve, though the rate of extremity injury remains quite high. The decision to proceed with amputation versus limb salvage remains controversial. Exposure to combat wound with severe high-energy lower extremity trauma during the...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000669
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3182539333
更新日期:2013-03-01 00:00:00
abstract::Nail plate combination technique can be applied in the setting of periprosthetic and interprosthetic fractures to promote reliable healing with a biomechanically favorable construct. Here, technical aspects and discussion of the technique are reviewed through a case of an 87-year-old woman who suffered from an interpr...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001571
更新日期:2019-09-01 00:00:00
abstract::Healthcare policy has changed drastically, and with the 50-year anniversary of the passage of Medicare approaching in 2015, the authors evaluate the development of the current healthcare system and its relationship to the development of modern orthopaedic trauma. With more changes in healthcare policy forthcoming, it ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000214
更新日期:2014-10-01 00:00:00
abstract:OBJECTIVE:Ankle fractures are one of the most common operatively treated lower extremity fractures. Several studies indicate that patients often have residual effects after this injury. The purpose of this study is to use the SF-36 questionnaire at two times to assess patients' functional recovery and residual effects ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200201000-00007
更新日期:2002-01-01 00:00:00
abstract::Unstable pelvic ring injuries are associated with an increased mortality rate, most commonly from severe hemorrhage. Circumferential pelvic antishock sheeting has proven effective for rapidly stabilizing the pelvic ring and has become an integral part of resuscitation protocols. Acute antishock sheet placement frequen...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181a87c6c
更新日期:2009-10-01 00:00:00
abstract::The use of Ender nails for the treatment of femoral shaft fractures has been described as technically easier and less time consuming than current intramedullary nailing techniques. We reviewed our results with unlocked Ender nails in 26 stable and 17 unstable fracture patterns an average of 3-4 years after injury. Bec...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199209000-00008
更新日期:1992-01-01 00:00:00