Radial Head Replacement Through a Kocher Approach.

Abstract:

PURPOSE:Radial head fractures are some of the most common elbow fractures. Fractures with 3 or more fracture fragments have been shown to have worse outcomes when treated with open reduction and internal fixation (ORIF). Radial head replacement offers an alternative treatment for those more comminuted radial head fractures. METHODS:Three-part radial head fractures make anatomical reduction more difficult to obtain with ORIF. Radial head fractures requiring replacement have shown good clinical outcomes. As a result, radial head arthroplasty offers a good treatment option for 3-or-more-part radial head fractures. RESULTS:This video presents a case of a radial head arthroplasty for a 3-part radial head fracture in a 23-year-old man. The radial head implant provides a smooth and concentric surface for articulation with the capitellum while providing stability to the elbow. CONCLUSIONS:Radial head replacement provides a good alternative to ORIF, producing similar elbow range of motion and providing good stability compared with the contralateral elbow.

journal_name

J Orthop Trauma

authors

Petersen KA,Siesel C,Miller ET

doi

10.1097/BOT.0000000000001537

subject

Has Abstract

pub_date

2019-08-01 00:00:00

pages

S11-S12

eissn

0890-5339

issn

1531-2291

pii

00005131-201908001-00007

journal_volume

33 Suppl 1

pub_type

杂志文章
  • Predictors of Improved Early Clinical Outcomes Following Elective Implant Removal.

    abstract:OBJECTIVES:To determine preoperative factors predictive of improvement in pain and function following elective implant removal. We hypothesized that patients undergoing orthopaedic implant removal to relieve pain would have significant improvements in both pain and function. DESIGN:Prospective Cohort Study SETTING:: L...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001920

    authors: Kempton LB,Gaski GE,Brown K,McKinley TO,Virkus WW

    更新日期:2020-10-13 00:00:00

  • Calcaneal Avulsion Fractures: A Multicenter Analysis of Soft-Tissue Compromise and Early Fixation Failure.

    abstract:OBJECTIVE:To characterize the presentation and outcomes of calcaneal avulsion fractures. DESIGN:Case series. SETTING:Two ACS Level I trauma centers. PATIENTS/PARTICIPANTS:Forty-seven calcaneal avulsion fractures isolated from a cohort of 1365 calcaneus fractures treated over a 17-year period. MAIN OUTCOME MEASUREME...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001582

    authors: Mitchell PM,OʼNeill DE,Branch E,Mir HR,Sanders RW,Collinge CA

    更新日期:2019-11-01 00:00:00

  • Comparison of Outcomes of Intertrochanteric Fracture Fixation Using Percutaneous Compression Plate Between Stable and Unstable Fractures in the Elderly.

    abstract:OBJECTIVES:To evaluate the outcomes of treatment with a percutaneous compression plate (PCCP) in stable and unstable intertrochanteric hip fractures. DESIGN:Clinical prospective nonrandomized cohort study. SETTING:San Cecilio University Hospital, Granada (Spain). A tertiary-care hospital. PATIENTS:Patients older tha...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000509

    authors: Carvajal-Pedrosa C,Gómez-Sánchez RC,Hernández-Cortés P

    更新日期:2016-06-01 00:00:00

  • The anterior intra-pelvic (modified rives-stoppa) approach for fixation of acetabular fractures.

    abstract:OBJECTIVES:Report the technical aspects, radiographic results, and complications after minimum 1-year follow up of the anterior intra-pelvic (AIP or modified Rives-Stoppa) approach as an alternative to the ilioinguinal approach for the treatment of acetabular fractures. DESIGN:Retrospective review. SETTING:Level I tr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181dd0b84

    authors: Sagi HC,Afsari A,Dziadosz D

    更新日期:2010-05-01 00:00:00

  • The surgical treatment of isolated mason type 2 fractures of the radial head in adults: comparison between radial head resection and open reduction and internal fixation.

    abstract:OBJECTIVES:To compare the outcomes of two different surgical treatments for the management of isolated closed Mason Type 2 radial head fractures. DESIGN:Retrospective study. The Student t test and McPearson chi-square test were used to evaluate whether there was a significance difference between the groups. PATIENTS:...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318220a227

    authors: Zarattini G,Galli S,Marchese M,Mascio LD,Pazzaglia UE

    更新日期:2012-04-01 00:00:00

  • Locking plates for distal femur fractures: is there a problem with fracture healing?

    abstract:OBJECTIVES:Fractures of the distal femur are severe injuries that present many clinical challenges. Nonunion, delayed union, implant failure, and the need for secondary procedures can reflect complications of healing. This article reviews the literature on distal femur fractures treated with locking plates to determine...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3182070127

    authors: Henderson CE,Kuhl LL,Fitzpatrick DC,Marsh JL

    更新日期:2011-02-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Lateral Humeral Condyle Fracture Pearls and Pitfalls.

    abstract::Lateral condyle fractures are second only to supracondylar humeral fractures when it comes to pediatric elbow fractures. Whether minimally displaced or substantially displaced, these growth plate fractures may present significant treatment challenges. These include nonunion, malunion, avascular necrosis, and growth di...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001543

    authors: Ho CA,Mehlman CT

    更新日期:2019-08-01 00:00:00

  • Biomechanical Assessment of Locking Plate Fixation of Comminuted Proximal Olecranon Fractures.

    abstract:OBJECTIVES:To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS:Comminuted osteotomies were created in 10 matched pairs of cadaveric uppe...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001279

    authors: Fantry A,Sobel A,Capito N,Hodax JD,Pidgeon T,Koruprolu S,Rich R,Fava JL,Green A,Paxton S

    更新日期:2018-11-01 00:00:00

  • Bone regeneration with resorbable polymeric membranes: treatment of diaphyseal bone defects in the rabbit radius with poly(L-lactide) membrane. A pilot study.

    abstract::Tubular poly(L-lactide) membranes with a pore size of 5-15 microns and a molecular weight of 70,000 Daltons were implanted into 24 New Zealand skeletally mature rabbits to cover 10-mm mid-diaphyseal defects of the radius of the forelimb. An identical defect on the contralateral limb was not treated with the membrane a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199604000-00006

    authors: Meinig RP,Rahn B,Perren SM,Gogolewski S

    更新日期:1996-01-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • Harvesting of autogenous cancellous bone graft from the proximal tibial metaphysis. A review of 230 cases.

    abstract::A study was undertaken to review the results of donor site morbidity of cancellous bone grafts obtained from the proximal tibial metaphysis. Two hundred six patients who underwent 230 proximal tibial bone graft harvestings were reviewed. Patients with lower-extremity fractures or nonunions who required cancellous bone...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199112000-00014

    authors: O'Keeffe RM Jr,Riemer BL,Butterfield SL

    更新日期:1991-01-01 00:00:00

  • Dual-energy X-ray absorptiometry as a measure of healing in fractures treated by intramedullary nailing.

    abstract::The conventional qualitative techniques of manual manipulation and plain radiography do not give a quantifiable measurement of healing. With internal fixation, manual manipulation is not usually possible, and conventional radiographs may not give much useful information, particularly if only a small amount of callus i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199611000-00010

    authors: Cattermole HC,Fordham JN,Muckle DS,Cunningham JL

    更新日期:1996-01-01 00:00:00

  • Deficit (14 cm) of the tibia solved by a double sliding graft using the Ilizarov apparatus.

    abstract::A 14 cm deficit of the tibia with a soft tissue deficit was resolved using the apparatus of Ilizarov. The apparatus was applied using a double corticotomy of the proximal and distal remainder of the tibia. The fragments were moved until they met each other in the central part of the deficit. Afterwards, a part of the ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Milicevic N

    更新日期:1990-01-01 00:00:00

  • Outcomes Following the Urgent Surgical Management of Displaced Femoral Neck Stress Fractures.

    abstract:OBJECTIVES:To review the clinical course, complication rates, and mid-term functional outcomes associated with the treatment of displaced femoral neck stress fractures (FNSFs). DESIGN:Retrospective Case Series. SETTING:Military Tertiary Referral Center. PATIENTS:Twenty-one operatively treated displaced FNSFs between...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001810

    authors: Cochran GK,Staeheli GR,Deafenbaugh BK,Kuhn KM

    更新日期:2020-11-01 00:00:00

  • A Machine Learning Algorithm to Predict the Probability of (Occult) Posterior Malleolar Fractures Associated With Tibial Shaft Fractures to Guide "Malleolus First" Fixation.

    abstract:OBJECTIVES:To develop an accurate machine learning (ML) predictive model incorporating patient, fracture, and trauma characteristics to identify individual patients at risk of an (occult) PMF. METHODS:Databases of 2 studies including patients with TSFs from 2 Level 1 trauma centers were combined for analysis. Using te...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001663

    authors: Hendrickx LAM,Sobol GL,Langerhuizen DWG,Bulstra AEJ,Hreha J,Sprague S,Sirkin MS,Ring D,Kerkhoffs GMMJ,Jaarsma RL,Doornberg JN,Machine Learning Consortium.

    更新日期:2020-03-01 00:00:00

  • Predictors of Unplanned Reoperation After Operative Treatment of Pelvic Ring Injuries.

    abstract:OBJECTIVES:To evaluate the incidence of unplanned reoperations after pelvic ring injuries and to develop a risk prediction model. DESIGN:Retrospective review. SETTING:Level I Trauma Center. PATIENTS:The medical records of 913 patients (644 male and 269 female patients; mean age, 39 years; age range, 16-89 years) wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001170

    authors: Ochenjele G,Reid KR,Castillo RC,Schoonover CD,Montalvo RN,Manson TT,Sciadini MF,Nascone JW,Carlini AR,OʼToole RV

    更新日期:2018-07-01 00:00:00

  • Pullout force of power-driven staples in cadaveric femoral metaphysis.

    abstract::The maximum pullout force in the distal metaphysis of cadaver femurs was investigated using a commercially available, pneumatically inserted staple. In paired studies, a significantly greater pullout force was required in the power-driven staples than in an almost identical sized hand-driven staple. A nonlinear relati...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199004020-00009

    authors: McCombe PF,Thomas AM,Pynsent PB,Thompson AG

    更新日期:1990-01-01 00:00:00

  • Impact of an Integrated Hip Fracture Inpatient Program on Length of Stay and Costs.

    abstract:BACKGROUND:Hip fractures are associated with significant morbidity and mortality. Co-management models pairing orthopaedic surgeons with hospitalists or geriatricians may be effective at improving processes of care and outcomes such as length of stay (LOS) and cost. We set out to determine the effect of an integrated h...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000691

    authors: Soong C,Cram P,Chezar K,Tajammal F,Exconde K,Matelski J,Sinha SK,Abrams HB,Fan-Lun C,Fabbruzzo-Cota C,Backstein D,Bell CM

    更新日期:2016-12-01 00:00:00

  • Do Safe Radiographic Sacral Screw Pathways Exist in a Pediatric Patient Population and Do They Change With Age?

    abstract:OBJECTIVES:Iliosacral screw pathways in the first (S1) and second (S2) sacral segments are commonly used for adult pelvic ring stabilization. We hypothesize that radiographically "safe" pathways exist in pediatric patients. SETTING:Academic level I Trauma Center. PATIENTS:All patients between ages 2 and 16 years with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0000000000000421

    authors: Burn M,Gary JL,Holzman M,Heydemann JA,Munz JW,Galpin M,Ambrose CG,Achor TS,Kumaravel M

    更新日期:2016-01-01 00:00:00

  • Biomechanical Stability of Volar Plate Only Versus Addition of Dorsal Ulnar Pin Plate: A Dorsal Ulnar Fragment, C-3-Type, Distal Radius, Cadaver Fracture Model.

    abstract:OBJECTIVE:To determine if the addition of a dorsal ulnar pin plate provides improved stability characteristics in the management of intra-articular distal radius fractures with an associated dorsal ulnar fragment. METHODS:OTA/AO type C3 fractures, with a dorsal ulnar fragment of one-third or one-half the width of the ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001776

    authors: Patrick NC,Lewis GS,Roush EP,Black SS,Henderson SR,Taylor KF

    更新日期:2020-09-01 00:00:00

  • Intramedullary nailing of the femoral shaft: a prospective, randomized study.

    abstract::We conducted a prospective, randomized study on 84 consecutive patients with 88 acute, traumatic femoral shaft fractures using 32 Grosse-Kempf nails, 29 Russell-Taylor nails, and 27 Synthes nails. Although total operative times and proximal and distal locking times were similar for the three groups, the procedure was ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0000000000000185

    authors: Cameron CD,Meek RN,Blachut PA,O'Brien PJ,Pate GC

    更新日期:2014-08-01 00:00:00

  • Posterior tibial tendon tear after 4-cortex syndesmotic screw fixation: a case report and literature review.

    abstract::We describe a previously unreported problem of a patient who underwent errant 4-cortex syndesmotic screw fixation with resultant posterior tibial tendon tear necessitating removal of hardware and repair of a tendon tear. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31821e127f

    authors: Kwon JY,Campbell JT,Myerson MS

    更新日期:2012-06-01 00:00:00

  • Common factors and outcome in late upper extremity amputations after military injury.

    abstract:OBJECTIVES:Much attention has been given to lower extremity amputations that occur more than 90 days after injury, but little focus has been given to analogous upper extremity amputations. The purpose of this study was to determine the reason(s) for desired amputation and the common complications after amputation for t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a665f5

    authors: Krueger CA,Wenke JC,Cho MS,Hsu JR

    更新日期:2014-04-01 00:00:00

  • No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures.

    abstract:OBJECTIVE:To determine whether stimulation with low-intensity ultrasound will reduce the radiologic healing time of fresh tibial shaft fractures fixed with a reamed and statically locked intramedullary rod. DESIGN:Prospective, randomized, double blinded, and placebo controlled. PATIENTS AND METHODS:Thirty-two adult p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199905000-00005

    authors: Emami A,Petrén-Mallmin M,Larsson S

    更新日期:1999-05-01 00:00:00

  • Retrograde Femoral Nailing Using Percutaneous Reduction Techniques.

    abstract::Femoral shaft fractures are commonly treated with closed reduction and reamed intramedullary nailing. However, some reductions are difficult to obtain or maintain, especially in muscular or large patients. When closed methods fail to achieve reduction, percutaneous techniques are extremely useful. In addition, the use...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000890

    authors: Pettett BJ,Avery MC,Ostrum RF

    更新日期:2017-08-01 00:00:00

  • Modern Results of Functional Bracing of Humeral Shaft Fractures: A Multicenter Retrospective Analysis.

    abstract:OBJECTIVES:To evaluate the rate of, and reasons for, conversion of closed treatment of humeral shaft fractures using a fracture brace, to surgical intervention. DESIGN:Multicenter, retrospective analysis. SETTING:Nine Level 1 trauma centers across the United States. PATIENTS:A total of 1182 patients with a closed hu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001666

    authors: Serrano R,Mir HR,Sagi HC,Horwitz DS,Borade A,Ketz JP,Kistler BJ,Quade JH,Beebe MJ,Au BK,Sanders RW,Shah AR

    更新日期:2020-04-01 00:00:00

  • Articulating external fixation to overcome nerve gaps in lower extremity trauma.

    abstract::This report describes the use of articulating external fixation in patients with lower extremity trauma with segmental nerve defects. Four patients who would otherwise require nerve grafting underwent application of an articulated external fixator, allowing optimal positioning for end-to-end, tension-free nerve repair...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200304000-00008

    authors: Ruch DS,Smith AM

    更新日期:2003-04-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Pediatric Femoral Shaft Fracture Pearls and Pitfalls.

    abstract::Pediatric femoral shaft fractures present many challenging patient care decisions. Nonoperative treatment approaches still dominate care of the youngest age groups while surgical intervention is commonplace in virtually all older children. Treatment is determined primarily by patient age as modified by clinical factor...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001016

    authors: Gordon JE,Mehlman CT

    更新日期:2017-11-01 00:00:00

  • Intracardiac malpositioning of a sternoclavicular fixation wire.

    abstract::A case of intracardiac malpositioning of a sternoclavicular Kirschner pin is reported. After an uneventful closed wire-fixation of sternoclavicular subluxation and a normal postanesthetic recovery, a 17-year-old male patient developed opacification of the right hemithorax and signs of internal bleeding. The lateral ch...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Smolle-Juettner FM,Hofer PH,Pinter H,Friehs G,Szyskowitz R

    更新日期:1992-01-01 00:00:00

  • Evaluation of the mangled extremity severity score in combat-related type III open tibia fracture.

    abstract:OBJECTIVES:The purpose of this study was to determine the extent to which the Mangled Extremity Severity Score (MESS) predicted outcomes for soldiers sustaining combat-related Gustilo-Anderson type III open tibia fractures. DESIGN:Retrospective cohort study. SETTING:Tertiary trauma center. PATIENTS:Service Members w...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000054

    authors: Sheean AJ,Krueger CA,Napierala MA,Stinner DJ,Hsu JR,Skeletal Trauma and Research Consortium (STReC).

    更新日期:2014-09-01 00:00:00