Abstract:
:Various simulation models of different complexity have been proposed to model the dynamic response of the human cardiovascular system. In a related paper we proposed an improved numerical model to study the dynamic response of the cardiovascular system, and the pressures, volumes and flow-rates in the four chambers of the heart, which included the effects of atrial contraction, atrioventricular interaction, and heart valve dynamics. This paper investigates the effects of each one of these aspects of the model on the overall dynamic system response. The dynamic response is studied under different situations, with and without including the effect of various features of the model, and these situations are studied and compared among themselves and to detailed aspects of expected healthy-system response. As an important contribution with potential clinical applications, this paper examines the corresponding effects of atrioventricular interaction, and heart valve opening and closing dynamics to the general system dynamic response. This isolation of physical cause-effect relationships is difficult to study with purely experimental methods. The simulation results agree well with results in the open literature. Comparison shows that introduction of these new features greatly improves the simulation accuracy of the effects of a, v and c waves, and in predicting regurgitant valve flow, the dichrotic notch, and E/A velocity ratio.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Korakianitis T,Shi Ydoi
10.1016/j.medengphy.2005.11.005subject
Has Abstractpub_date
2006-10-01 00:00:00pages
762-79issue
8eissn
1350-4533issn
1873-4030pii
S1350-4533(05)00247-Xjournal_volume
28pub_type
杂志文章abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.09.009
更新日期:2016-11-01 00:00:00
abstract::This study tested the effectiveness of low-level laser therapy (LLLT) in preventing and/or treating osteoporotic trabecular bone. Mice were ovariectomized (OVX) to induce osteoporotic bone loss. The tibiae of eight OVX mice were treated for 5 days each week for 2 weeks by LLLT (660 nm, 3 J) using a minimally invasive ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.10.002
更新日期:2013-07-01 00:00:00
abstract::For many decades correlation and power spectrum have been primary tools for digital signal processing applications in the biomedical area. The information contained in the power spectrum is essentially that of the autocorrelation sequence; which is sufficient for complete statistical descriptions of Gaussian signals o...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2010.04.009
更新日期:2010-09-01 00:00:00
abstract::The construction and performance of a 5.4 m3 combined direct and indirect calorimeter for human subjects is described. The calorimeter was constructed for studies on human subjects primarily undergoing fast alterations in heat production and heat losses, e.g. after a meal or during physical exercise. A heat sink and a...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00037-x
更新日期:1998-06-01 00:00:00
abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.09.003
更新日期:2020-11-01 00:00:00
abstract::A three-layer artificial neural network was used for adaptive control of gait swing generated by neuromuscular electrical stimulation (NMES) in a spinal cord injured subject. Network inputs consisted of knee and ankle goniometer signals for System 1, and knee and hip angular data for System 2. Controller output was pr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00030-6
更新日期:1997-01-01 00:00:00
abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.11.004
更新日期:2010-03-01 00:00:00
abstract::Pressure ulcers are a major problem worldwide believed to affect over 5% of all hospital in-patients, and countless others in the community at large. Many types of Patient Support Systems (PSS) are sold as pressure ulcer prevention equipment, but no consensus exists as to their mechanical efficacy. The use of human vo...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(99)00053-3
更新日期:1999-06-01 00:00:00
abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2004.03.002
更新日期:2004-07-01 00:00:00
abstract::Balance impairment is critical for many patient groups such as those with neural and musculoskeletal disorders and also the elderly. Accurate and objective assessment of balance performance has led to the development of several indices based on the measurement of the center of pressure. In this study, a robotic device...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.07.006
更新日期:2020-09-01 00:00:00
abstract::In this study we integrated between confocal-based cell-specific finite element (FE) modeling and Virtual Cell (VC) transport simulations in order to determine trends of relationship between externally applied compressive deformations and build-up rates of oxygen in myoblast cells, and to further test how mild culture...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.04.008
更新日期:2011-11-01 00:00:00
abstract::During fatiguing contractions, many adjustments in motor units behaviour occur: decrease in muscle fibre conduction velocity; increase in motor units synchronisation; modulation of motor units firing rate; increase in variability of motor units inter-spike interval. We simulated the influence of all these adjustments ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.09.022
更新日期:2016-12-01 00:00:00
abstract::The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe tha...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.07.014
更新日期:2014-11-01 00:00:00
abstract::Cervical spinal instability due to ligamentous injury, degenerated disc and facetectomy is a subject of great controversy. There is no analytical investigation reported on the biomechanical response of cervical spine in these respects. Parametric study on the roles of ligaments, facets, and disc nucleus of human lower...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00036-4
更新日期:2001-04-01 00:00:00
abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(03)00099-7
更新日期:2003-12-01 00:00:00
abstract::Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults with sleep disordered breathing (SDB). Hence, this shows promise to be an effective screening tool for the paediatrics. However, little is known about its utility and suita...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2006.01.006
更新日期:2007-01-01 00:00:00
abstract::Comprehensive evaluation of results obtained using acoustic and contact microphones in screening for laryngeal disorders through analysis of sustained phonation is the main objective of this study. Aiming to obtain a versatile characterization of voice samples recorded using microphones of both types, 14 different set...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.12.005
更新日期:2015-02-01 00:00:00
abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.01.001
更新日期:2014-06-01 00:00:00
abstract::Truly representative architectural parameters of trabeculea can be extremely difficult to achieve based on scanning images because of variable porosity and distribution of trabeculae within the specific overall scanned volume of bone. Accordingly, in present study different selective volume of interests, measured from...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.01.014
更新日期:2011-07-01 00:00:00
abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00003-5
更新日期:1999-12-01 00:00:00
abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.06.011
更新日期:2014-09-01 00:00:00
abstract::This paper describes a non-invasive human brain-actuated robotic arm experiment, which allows remote writing. In the local environment, the participant decides on an arbitrary word to transmit. A mental speller interface is then used to select the letters. A robot arm placed in the remote environment writes the word o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.06.005
更新日期:2011-12-01 00:00:00
abstract::Most surgical procedures in breast plastic surgery are either reconstructive procedures following oncologic interventions (tumorectomy, quadrantectomy, mastectomy ...) or aesthetic ones, both augmentation and reduction. With current techniques, the results of such procedures cannot be fully guaranteed. Usually, surgic...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.01.005
更新日期:2008-11-01 00:00:00
abstract::Inserting the distal locking screws is a challenging step of the intramedullary nailing procedures due to the nail deformation that makes the proximally mounted targeting systems ineffective. A pre-planning methodology is proposed, based on an analytical model of the nail-bone construct, to predict the nail deformatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.012
更新日期:2019-12-01 00:00:00
abstract::Neointimal hyperplasia (NIH) is a major obstacle to graft patency in the peripheral arteries. A complex interaction of biomechanical factors contribute to NIH development and progression, and although haemodynamic markers such as wall shear stress have been linked to the disease, these have so far been insufficient to...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.011
更新日期:2019-12-01 00:00:00
abstract::Two quantitative techniques have been evaluated to examine whether respiratory sinus arrhythmia can be detected in atrial fibrillation. Cyclical changes in heart rate during deep breathing indicating respiratory sinus arrhythmia were seen in 11/15 control patients, but only 1/44 patients with atrial fibrillation. Powe...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/1350-4533(94)90061-2
更新日期:1994-07-01 00:00:00
abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.02.012
更新日期:2015-05-01 00:00:00
abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00121-7
更新日期:2002-03-01 00:00:00
abstract::The mean value and standard deviation of localization error for the stereo imaging systems are derived based on probability theory. Compared with the maximum error analysis method used in our previous study, the new approach yields more informative and precise results as the guidance for X-ray imaging system design an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00084-4
更新日期:2001-10-01 00:00:00
abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.003
更新日期:2016-03-01 00:00:00