Data dependent random forest applied to screening for laryngeal disorders through analysis of sustained phonation: acoustic versus contact microphone.

Abstract:

:Comprehensive evaluation of results obtained using acoustic and contact microphones in screening for laryngeal disorders through analysis of sustained phonation is the main objective of this study. Aiming to obtain a versatile characterization of voice samples recorded using microphones of both types, 14 different sets of features are extracted and used to build an accurate classifier to distinguish between normal and pathological cases. We propose a new, data dependent random forests-based, way to combine information available from the different feature sets. An approach to exploring data and decisions made by a random forest is also presented. Experimental investigations using a mixed gender database of 273 subjects have shown that the perceptual linear predictive cepstral coefficients (PLPCC) was the best feature set for both microphones. However, the linear predictive coefficients (LPC) and linear predictive cosine transform coefficients (LPCTC) exhibited good performance in the acoustic microphone case only. Models designed using the acoustic microphone data significantly outperformed the ones built using data recorded by the contact microphone. The contact microphone did not bring any additional information useful for the classification. The proposed data dependent random forest significantly outperformed the traditional random forest.

journal_name

Med Eng Phys

authors

Verikas A,Gelzinis A,Vaiciukynas E,Bacauskiene M,Minelga J,Hållander M,Uloza V,Padervinskis E

doi

10.1016/j.medengphy.2014.12.005

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

210-8

issue

2

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(15)00004-1

journal_volume

37

pub_type

杂志文章
  • Effects of mechanical loading on the profile of human femoral diaphyseal geometry.

    abstract::In vivo bone behaviour predictions with respect to altered loading conditions, implants, and endoprostheses are highly desirable to avoid untoward effects such as implant loosening and breakage. This knowledge does not relate only to the result but also to the mechanisms of bone adaptation and bone growth. Since bone ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90014-0

    authors: Mittlmeier T,Mattheck C,Dietrich F

    更新日期:1994-01-01 00:00:00

  • Accelerometer based calf muscle pump activity monitoring.

    abstract::Long distance travel is associated with increased risk of deep vein thrombosis (DVT). There is an increased risk of travel related DVT in passengers with a predisposition to thrombosis. Assisting blood circulation in the lower limb will reduce the risk of DVT. Leg exercises are recommended as a DVT preventative measur...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.02.002

    authors: O'Donovan KJ,O'Keeffe DT,Grace PA,Lyons GM

    更新日期:2005-10-01 00:00:00

  • In vitro assessment of mitral valve function in cyclically pressurized porcine hearts.

    abstract::Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experime...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.01.007

    authors: Vismara R,Leopaldi AM,Piola M,Asselta C,Lemma M,Antona C,Redaelli A,van de Vosse F,Rutten M,Fiore GB

    更新日期:2016-04-01 00:00:00

  • Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking.

    abstract::This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54 +/- 12 years, mass: 84.3 +/- 16.3 kg, height: 17.8 +/- 0.10 m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.003

    authors: Lee WC,Frossard LA,Hagberg K,Haggstrom E,Gow DL,Gray S,Brånemark R

    更新日期:2008-09-01 00:00:00

  • Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.009

    authors: Kahl L,Hofmann UG

    更新日期:2016-11-01 00:00:00

  • Real time monitoring of muscular fatigue from dynamic surface myoelectric signals using a complex covariance approach.

    abstract::A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00049-1

    authors: Conforto S,D'Alessio T

    更新日期:1999-05-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • Effect of the stiffness of bone substitutes on the biomechanical behaviour of femur for core decompression.

    abstract::Core decompression is the most common procedure for treatment of the early stages of osteonecrosis of the femoral head. The purpose of this study was to compare the biomechanical performance of four different bone graft substitutes combined with core decompression. Subject-specific finite element models generated from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.008

    authors: Tran TN,Kowalczyk W,Hohn HP,Jäger M,Landgraeber S

    更新日期:2016-09-01 00:00:00

  • Regression-based indices of fatigue in paraplegics' electrically stimulated quadriceps.

    abstract::We studied muscle fatigue in 19 paraplegic patients during an isometric sustained contraction. Both quadriceps (n = 38) were maximally stimulated for 126 s. We defined a nonlinear equation with four coefficients to fit the data and extract fatigue indices carrying information on the amount (asymptotic values, torque c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00038-6

    authors: Rabischong E,Chavet P

    更新日期:1997-12-01 00:00:00

  • Robust infrarenal aortic aneurysm lumen centerline detection for rupture status classification.

    abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.005

    authors: Zhang H,Kheyfets VO,Finol EA

    更新日期:2013-09-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00

  • Suitability of commercial barometric pressure sensors to distinguish sitting and standing activities for wearable monitoring.

    abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.001

    authors: Massé F,Bourke AK,Chardonnens J,Paraschiv-Ionescu A,Aminian K

    更新日期:2014-06-01 00:00:00

  • A model of lung parenchyma stress relaxation using fractional viscoelasticity.

    abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.05.003

    authors: Dai Z,Peng Y,Mansy HA,Sandler RH,Royston TJ

    更新日期:2015-08-01 00:00:00

  • Development of a small wireless device for perspiration monitoring.

    abstract::A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.009

    authors: Ogai K,Fukuoka M,Kitamura K,Uchide K,Nemoto T

    更新日期:2016-04-01 00:00:00

  • A mathematical model of the impact response of the seated subject.

    abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00062-3

    authors: Broman H,Pope M,Hansson T

    更新日期:1996-07-01 00:00:00

  • Estimation of pulsatile cerebral arterial blood volume based on transcranial doppler signals.

    abstract:OBJECTIVE:Mathematical modeling of cerebral hemodynamics by descriptive equations can estimate the underlying pulsatile component of cerebral arterial blood volume (CaBV). This way, clinical monitoring of changes in cerebral compartmental compliances becomes possible. Our aim is to validate the most adequate method of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.019

    authors: Calviello LA,Zeiler FA,Donnelly J,Uryga A,de Riva N,Smielewski P,Czosnyka M

    更新日期:2019-12-01 00:00:00

  • Bioelectric signal detrending using smoothness prior approach.

    abstract::Bioelectric signals such as electromyogram (EMG) and electrocardiogram (ECG) are often affected by various low-frequency trending interferences. It is critical to remove these interferences from the recordings so that the critical features of the bioelectric signals could be clearly observed. In this study, an advance...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.009

    authors: Zhang F,Chen S,Zhang H,Zhang X,Li G

    更新日期:2014-08-01 00:00:00

  • Numerical simulations of particle dynamics in a poststenotic blood vessel region within the scope of extracorporeal ultrasound stenosis treatment.

    abstract::A numerical model was developed to predict the dynamics of a solid particle in a poststenotic blood vessel region. The flow through a 3D axisymmetric stenosis with 75% reduction in cross-section area was considered for inlet Reynolds numbers of 500 and 1000, which corresponds to typical values for the blood flow in hu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.003

    authors: Dhahbi M,Ben Chiekh M,Gilles B,Béra JC,Jemni A

    更新日期:2012-09-01 00:00:00

  • Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.

    abstract::The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.03.019

    authors: Merino M,Gómez IM,Molina AJ

    更新日期:2015-06-01 00:00:00

  • Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.02.006

    authors: Jiang S,Gan RZ

    更新日期:2018-04-01 00:00:00

  • Finite element prediction of surface strain and fracture strength at the distal radius.

    abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.016

    authors: Edwards WB,Troy KL

    更新日期:2012-04-01 00:00:00

  • Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate.

    abstract::Locking compression plates (LCPs) have been used to fix femoral shaft fractures. Previous studies have attempted to identify the best LCP screw positions and numbers to achieve the fixation stability. However, the determined screw positions and numbers were mainly based on the surgeons' experiences. The aim of this st...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.005

    authors: Lee CH,Shih KS,Hsu CC,Cho T

    更新日期:2014-01-01 00:00:00

  • New equations to calculate 3D joint centres in the lower extremities.

    abstract::Biomechanical movement analysis in 3D requires estimation of joint centres in the lower extremities and this estimation is based on extrapolation from markers placed on anatomical landmarks. The purpose of the present study was to quantify the accuracy of three established set of equations and provide new improved equ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.07.001

    authors: Sandau M,Heimbürger RV,Villa C,Jensen KE,Moeslund TB,Aanæs H,Alkjær T,Simonsen EB

    更新日期:2015-10-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • A complete, non-lumped, and verifiable set of upper body segment parameters for three-dimensional dynamic modeling.

    abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.09.008

    authors: Vette AH,Yoshida T,Thrasher TA,Masani K,Popovic MR

    更新日期:2011-01-01 00:00:00

  • Characterization of crackles from patients with fibrosis, heart failure and pneumonia.

    abstract::The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.009

    authors: Ponte DF,Moraes R,Hizume DC,Alencar AM

    更新日期:2013-04-01 00:00:00

  • Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.

    abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00037-7

    authors: Imai S,Higashijima K,Ishida A,Fukuoka Y,Hoshino A,Minamitani H

    更新日期:2003-06-01 00:00:00

  • Diffusion coefficients of articular cartilage for different CT and MRI contrast agents.

    abstract::In contrast enhanced magnetic resonance imaging (MRI) and computed tomography (CT), the equilibrium distribution of anionic contrast agent is expected to reflect the fixed charged density (FCD) of articular cartilage. Diffusion is mainly responsible for the transport of contrast agents into cartilage. In osteoarthriti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.002

    authors: Kulmala KA,Korhonen RK,Julkunen P,Jurvelin JS,Quinn TM,Kröger H,Töyräs J

    更新日期:2010-10-01 00:00:00

  • Significance of spine stability criteria on trunk muscle forces following unilateral muscle weakening: A comparison between kinematics-driven and stability-based kinematics-driven musculoskeletal models.

    abstract::Two optimization-driven approaches were employed to develop kinematics-driven (KD) and stability-based kinematics-driven (SKD) musculoskeletal models of an adult thoracolumbar to ascertain the significance of spine stability in holding the upright-standing posture after muscular disuse atrophy. Both models were used t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.008

    authors: Kamal Z,Rouhi G

    更新日期:2019-11-01 00:00:00

  • Dynamic cerebral autoregulation assessment using an ARX model: comparative study using step response and phase shift analysis.

    abstract::Middle cerebral arterial blood velocity (MCAv) response to spontaneous and manipulated changes of arterial blood pressure (ABP) was studied in eight subjects using a linear autoregressive with exogenous input (ARX) model. ABP and MCAv were measured non-invasively by photoplethysmograph and transcranial Doppler ultraso...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00015-8

    authors: Liu Y,Birch AA,Allen R

    更新日期:2003-10-01 00:00:00