Abstract:
:Mice, previously immunized with sheep erythrocytes, were anaesthetized with halothane and the splenic lymphoid cells were incubated with 3H-thymidine at 1-h intervals. Abiphasic response was observed; 0.9 and 1.5% halothane reduced 3H-thymidine incorporation into the primed lymphoid cells by 83 and 94% respectively, while 0.4% halothane stimulated it by 5% of control at 3H. Immunosuppression by halothane may be the result of reduced 3H-thymidine uptake of the dividing immunocytes.
journal_name
Br J Anaesthjournal_title
British journal of anaesthesiaauthors
Bandoh T,Fujita Tdoi
10.1093/bja/48.12.1129subject
Has Abstractpub_date
1976-12-01 00:00:00pages
1129-33issue
12eissn
0007-0912issn
1471-6771pii
S0007-0912(17)46267-2journal_volume
48pub_type
杂志文章abstract::The use of atracurium during major abdominal surgery was assessed in 20 infants with hepatic dysfunction caused by biliary atresia. An initial dose of 0.6 mg kg-1 provided excellent intubating conditions in all patients. Subsequent neuromuscular blockade was monitored with a peripheral nerve stimulator and incremental...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/58.11.1214
更新日期:1986-11-01 00:00:00
abstract:BACKGROUND:The cuff pressures may be different in oesophageal and tracheal intubations. We conducted a study to evaluate if cuff pressures of endotracheal tubes (ETTs) could provide information to distinguish tracheal or oesophageal intubations in a pig trachea-oesophagus model. METHODS:In each preparation of pig trac...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aem244
更新日期:2007-11-01 00:00:00
abstract:INTRODUCTION:In the context of an increasing number of publications of trial data analysed by Bayesian methods, clinicians need support to better understand Bayesian statistical methods. The existing checklists are intended for people who already know these methods. We aimed to establish and validate a checklist that c...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1016/j.bja.2020.04.093
更新日期:2020-08-01 00:00:00
abstract:BACKGROUND:Better education of clinicians is expected to enhance patient safety. An important component of education is adherence to standard protocols, which are mainly available in written form. Believing in the potential power of videos, we hypothesized that the introduction of an educational video, based on an inst...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aew030
更新日期:2016-05-01 00:00:00
abstract::We studied the elimination rate of nitrous oxide in 36 patients undergoing orthopaedic surgery. They were allocated randomly to one of six groups which differed in time of nitrous oxide exposure and mode of ventilation. In order to simulate recovery conditions, nitrous oxide administration was discontinued after 30, 6...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/71.2.189
更新日期:1993-08-01 00:00:00
abstract:BACKGROUND:Vasopressor agents are used to prevent intraoperative hypotension and ensure adequate perfusion. Vasopressors are usually administered as intermittent boluses or manually adjusted infusions, but this practice requires considerable time and attention. We have developed a closed-loop vasopressor (CLV) controll...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1016/j.bja.2019.04.064
更新日期:2019-10-01 00:00:00
abstract::Blood transfusion saves many lives but carries significant risk of injury. Currently, red blood cell (RBC) concentrates can be stored up to 42 days. Concerns have recently been raised about the safety and efficacy of transfusing stored RBCs. Refrigerated storage results in a 'storage lesion' that is reflected by metab...
journal_title:British journal of anaesthesia
pub_type: 杂志文章,评审
doi:10.1093/bja/aet405
更新日期:2013-12-01 00:00:00
abstract:Background:. Missense variants in the ryanodine receptor 1 gene ( RYR1 ) are associated with malignant hyperthermia but only a minority of these have met the criteria for use in predictive DNA diagnosis. We examined the utility of a simplified method of segregation analysis and a functional assay for determining the pa...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aex042
更新日期:2017-04-01 00:00:00
abstract::We describe a 25 mg intrathecal morphine overdose during a combined spinal-epidural block for a Caesarean delivery. Naloxone infusion (5.24 mg over 24 h) was started prior to the patient becoming symptomatic and almost immediately after the overdose. Invasive therapeutics such as mechanical ventilation were avoided. ...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aef286
更新日期:2002-12-01 00:00:00
abstract:BACKGROUND:It is believed that the severely disturbed night-time sleep architecture after surgery is associated with increased cardiovascular morbidity with rebound of rapid eye movement (REM). The daytime sleep pattern of patients after major general surgery has not been investigated before. We decided to study the ci...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aem340
更新日期:2008-01-01 00:00:00
abstract::We have investigated the effect of interpleural morphine on postoperative pain and pulmonary function after thoracotomy. At the end of surgery, an interpleural catheter was inserted in 17 patients and, in a double-blind and randomized manner, either a bolus of morphine 2.5 mg interpleurally (i.p.) and normal saline i....
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/69.6.637
更新日期:1992-12-01 00:00:00
abstract::In obstetric patients undergoing postpartum tubal ligation, we found that metoclopramide produced dose-dependent prolongation of suxamethonium-induced neuromuscular block. Mean block times after suxamethonium 1 mg kg-1 were 8.0 min, 9.83 min and 12.45 min for control and metoclopramide 10 mg and metoclopramide 20 mg g...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章
doi:10.1093/bja/65.2.220
更新日期:1990-08-01 00:00:00
abstract:BACKGROUND:Malposition of tracheostomy tubes is difficult to detect at the bedside and may contribute to eventual device misplacement. Endoscopic examination can be undertaken via tracheoscopic (T-view) or trans-laryngeal (L-view) approach, offering more precise detail regarding positioning within the airway. The aims ...
journal_title:British journal of anaesthesia
pub_type: 评论,信件
doi:10.1093/bja/aew336
更新日期:2017-01-01 00:00:00
abstract:BACKGROUND:The Laryngeal Tube (LT) performs similarly to the classic laryngeal mask airway during controlled ventilation but with an improved airway seal. We compared the laryngeal tube with the ProSeal laryngeal mask airway (PLMA) throughout anaesthesia. METHODS:Thirty-two patients were studied using a randomized cro...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/aeg239
更新日期:2003-11-01 00:00:00
abstract::We have compared the ability of naïve intubators to intubate the trachea using a laryngoscope and an intubating laryngeal mask airway (ILMA) after receiving basic training, in a randomized, prospective, crossover study in 60 patients. Ventilation of the lungs via the ILMA was also compared with ventilation with a face...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/83.4.615
更新日期:1999-10-01 00:00:00
abstract::Cancer survivorship represents a growing clinical challenge for pain clinicians. The population of cancer survivors is rapidly expanding and many of these patients experience pain as a sequelae of their disease and its treatment. The features, pathophysiology and natural history of some painful conditions observed in ...
journal_title:British journal of anaesthesia
pub_type: 杂志文章,评审
doi:10.1093/bja/aex202
更新日期:2017-10-01 00:00:00
abstract::A simple method of adapting a pressure-cycled ventilator of the flow generator type to ventilate patients on a circle-absorber anaesthetic system is described. Standard lengths of corrugated black rubber tubing are placed between the ventilator and the circle-absorber is deadspace, replacing the reservoir bag. The per...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/49.3.273
更新日期:1977-03-01 00:00:00
abstract::We have studied the effect of clonidine, dexmedetomidine and morphine on gastric emptying and gastrointestinal transit in the rat. In one group, each agonist was injected i.p. in 6-12 male Wistar rats. In another group of rats, yohimbine, naloxone or saline was injected with an agonist. At 30 min, radiolabelled saline...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/78.3.301
更新日期:1997-03-01 00:00:00
abstract:BACKGROUND:There is little advice on the posture to be used when intubating the trachea. Does the stance used depend on experience? METHODS:Twenty-six subjects with varying experience of intubation were photographed during laryngoscopy of an intubation training mannequin. Posture was measured from the photographs and ...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:
更新日期:2002-11-01 00:00:00
abstract:BACKGROUND:Increased BMI may increase the body's capacity to store potent inhaled anaesthetics, more so with more soluble agents. Accordingly, we asked whether increased BMI and longer anaesthesia prolonged airway reflex recovery. METHODS:We measured time from anaesthetic discontinuation until first response to comman...
journal_title:British journal of anaesthesia
pub_type: 杂志文章,随机对照试验
doi:10.1093/bja/aep374
更新日期:2010-02-01 00:00:00
abstract::The value of the continuous monitoring of end-tidal carbon dioxide concentration as an indicator of the acute intraoperative interruption of pulmonary blood flow, in patients with pre-existing restrictions of pulmonary blood flow undergoing closed heart surgery, is illustrated by two case reports. Decreases in end-tid...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/57.12.1257
更新日期:1985-12-01 00:00:00
abstract::Relative humidity of air produced by simple compressors used to drive ventilators was measured at different working pressures. At normal working pressures, a relative humidity of 100% was found and condensation occurred, mainly at the high pressure air/oxygen mixer valve. This resulted in blockages and loss of accurac...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/53.5.549
更新日期:1981-05-01 00:00:00
abstract::We conducted a prospective, randomized, double-blind study to compare analgesia obtained by wound infiltration using 29 ml of 0.25% bupivacaine alone, or with the addition of clonidine hydrochloride 150 micrograms. A third group received bupivacaine wound infiltration with clonidine 150 micrograms i.m. to control for ...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/79.4.446
更新日期:1997-10-01 00:00:00
abstract:BACKGROUND:Low fibrinogen (Fg) concentrations in trauma haemorrhage are associated with poorer outcomes. Cryoprecipitate is the standard source for Fg administration in the UK and USA and is often given in the later stages of transfusion therapy. It is not known whether early cryoprecipitate therapy improves clinical o...
journal_title:British journal of anaesthesia
pub_type: 杂志文章,随机对照试验
doi:10.1093/bja/aev134
更新日期:2015-07-01 00:00:00
abstract::We have compared, in a randomized, double-blind study, the pharmacokinetics of ropivacaine and bupivacaine during labour. Total and free plasma concentrations of ropivacaine and bupivacaine were measured after the first of two extradural doses. The main dose was 20 mg (test dose) and 30 mg, with a top-up dose of 25 mg...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/79.5.558
更新日期:1997-11-01 00:00:00
abstract::Three hundred and twenty adults (ASA grade I, both sexes), received diazepam 10 mg by mouth (50% received atropine 7 micrograms kg-1 in addition) i.m. 45 min before operation. Patients were then allocated randomly to undergo general anaesthesia with either a nitrous oxide-neurolept technique or nitrous oxide-halothane...
journal_title:British journal of anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1093/bja/62.2.194
更新日期:1989-02-01 00:00:00
abstract::We have assessed a prototype laryngeal mask airway (pLMA) in 50 anaesthetized children for ease of insertion, oropharyngeal leak pressures, gastric insufflation and fibreoptic position. The pLMA has a second smaller mask, which rests against the upper oesophageal sphincter, and a second cuff to increase the seal press...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/82.1.132
更新日期:1999-01-01 00:00:00
abstract:BACKGROUND:The purpose of this observational study was to investigate the relationship between splanchnic and renal blood flow during infrarenal aortic cross-clamp (XC) and postoperative gastrointestinal perfusion and function. METHODS:Descending aortic blood flow (DABF) was continuously monitored with an oesophageal ...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aes095
更新日期:2012-06-01 00:00:00
abstract::Fast inactivation of sodium channel function is modified by anaesthetics. Its quantitative contribution to the overall anaesthetic effect is assessed by removing the fast inactivation mechanism enzymatically. Sodium channels from human brain cortex were incorporated into planar lipid bilayers. After incorporation, cha...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/82.1.74
更新日期:1999-01-01 00:00:00
abstract:BACKGROUND:This study compares cardiac output (CO) measurements obtained by lithium dilution (LiDCO), pulse power analysis (PulseCO), and continuous thermodilution (CTD) with bolus thermodilution (BTD) in ponies. METHODS:Eight isoflurane-anaesthetized Shetland ponies received xylazine, ketamine, and midazolam infusion...
journal_title:British journal of anaesthesia
pub_type: 杂志文章
doi:10.1093/bja/aes269
更新日期:2012-12-01 00:00:00