Limitations of exercise testing in critical left coronary artery disease.

Abstract:

:Exercise testing was evaluated in 51 patients with critical left coronary artery disease (LCA) documented by coronary arteriography within two weeks of their bicycle ergometer (26 patients) or treadmill (25 patients) electrocardiographic study. Adequate tests, as defined by the patient having reached 85% of predicted maximum heart rate, were achieved in only 16 patients on the ergometer (62%) and in 21 (84%) on the treadmill. Nevertheless mean maximum double product (220 vs 232) and mean exercise time (4.6 min vs 5.0 min.) were similar (p:NS). The sensitivity for ergometry and treadmill testing was 75 and 62% respectively. If however we include those negative studies in which for various reasons patients were unable to achieve 85% of their predicted maximal heart rate (i.e., inadequate studies), sensitivity was only 46 and 52% respectively. Thus a sizable group of patients with critical LCA disease cannot adequately perform exercise tests especially on the ergometer; and over half of all such patients studied will be found for one reason or another to respond negatively, regardless of exercise protocol.

journal_name

J Electrocardiol

authors

Timmis GC,Westveer DC,Gordon S,Ramos RG,Gangadharan V

doi

10.1016/s0022-0736(79)80057-6

subject

Has Abstract

pub_date

1979-07-01 00:00:00

pages

241-8

issue

3

eissn

0022-0736

issn

1532-8430

journal_volume

12

pub_type

杂志文章
  • Apparent electrocardiogram left ventricular hypertrophy during tachycardia.

    abstract::The electrocardiographic transient display of left ventricular hypertrophy (LVH), during rapid heart rates, in the setting of sinus/supraventricular tachycardias and atrial fibrillation, is illustrated via 3 case reports. This common occurrence is expressed by an increase in the S-waves in leads V2-V5, during tachycar...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2021.01.001

    authors: Madias JE

    更新日期:2021-01-09 00:00:00

  • QRS broadening due to terminal distortion is associated with the size of myocardial injury in experimental myocardial infarction.

    abstract:INTRODUCTION:Not only repolarization, but also depolarization ECG indexes reflect the progression of ischemic injury. The aim was to assess the QRS duration and morphology dynamics during the prolonged coronary occlusion and their association with the myocardial area at risk (MaR) and final infarct size (IS). METHODS:...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2016.03.014

    authors: Demidova MM,Martín-Yebra A,Koul S,Engblom H,Martínez JP,Erlinge D,Platonov PG

    更新日期:2016-05-01 00:00:00

  • Electrocardiogram training for residents: A curriculum based on Facebook and Twitter.

    abstract:BACKGROUND:We studied whether social media applications can serve as effective educational tools for teaching electrocardiogram (ECG) interpretation to medical residents. METHODS:39 emergency, family, and internal medicine residents participated in the 33-week "ECG of the Week" curriculum via Facebook and Twitter. ECG...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2017.04.010

    authors: Liu SS,Zakaria S,Vaidya D,Srivastava MC

    更新日期:2017-01-01 00:00:00

  • Wide complex tachycardia cycle length shorter than the narrow complex tachycardia. What is the mechanism?

    abstract::15-Year-old man's cardiac event monitor showed an episode of wide complex tachycardia which transitioned into narrow complex tachycardia. The tachycardia cycle length was shorter during wide complex tachycardia compared with narrow complex tachycardia. He underwent electrophysiology study in which an orthodromic atrio...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2020.02.002

    authors: Tan VH,Yeo C,Wong K

    更新日期:2020-01-01 00:00:00

  • Vectorcardiographic criteria of high posterior infarction: differentiation from normal subjects, right ventricular hypertrophy and primary myocardial disease.

    abstract::In order to differentiate the vectorcardiogram (VCG) in high posterior infarction (HPI) from VCGs of normal subjects, right ventricular hypertrophy (RVH) and primary myocardial disease (PMD), the following criteria were presented; cases satisfying the criteria could be diagnosed as high posterior infarction. In cases ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(78)80107-1

    authors: Suzuki K,Toyama S

    更新日期:1978-04-01 00:00:00

  • Impact of number of co-existing rotors and inter-electrode distance on accuracy of rotor localization.

    abstract:BACKGROUND:Conflicting evidence exists on the efficacy of focal impulse and rotor modulation on atrial fibrillation ablation. A potential explanation is inaccurate rotor localization from multiple rotors coexistence and a relatively large (9-11mm) inter-electrode distance (IED) of the multi-electrode basket catheter. ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2017.08.032

    authors: Aronis KN,Ashikaga H

    更新日期:2018-01-01 00:00:00

  • Intravenous electrocardiographic guidance for placement of peripherally inserted central catheters.

    abstract:BACKGROUND:Correct positioning of peripherally inserted central catheters (PICCs) is essential to avoid complications. We evaluated intravenous electrocardiogram (ECG) recordings during PICC placement to assess the effectiveness of this guidance technique to reduce complications resulting from incorrect catheter placem...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2010.02.003

    authors: Smith B,Neuharth RM,Hendrix MA,McDonnall D,Michaels AD

    更新日期:2010-05-01 00:00:00

  • Simulation of the QRS complex using papillary muscle positions as the site of early activation in human subjects.

    abstract:BACKGROUND:Simulation of the electrical activation of the heart and its comparison with real in vivo activation is a promising method in testing potential determinants of excitation. Simulation of the electrical activity of the human heart is now emerging as a step forward for understanding and predicting electrophysio...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2008.12.008

    authors: Hakacova N,Bass GD,Olson CW,Robinson AM,Selvester RH

    更新日期:2009-03-01 00:00:00

  • The role of pacing-induced dyssynchrony in left ventricular remodeling associated with long-term right ventricular pacing for atrioventricular block.

    abstract:AIMS:Patients with atrioventricular (AV) block can develop left ventricular (LV) dysfunction with long-term right ventricular pacing (RVP). We investigated the role of RVP-induced LV dyssynchrony in this adverse remodeling. METHODS AND RESULTS:Nineteen patients with normal LV function undergoing pacemaker implantation...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2012.04.001

    authors: Pap R,Gallardo R,Rónaszéki D,Ágoston G,Traykov VB,Sághy L,Varga A,Forster T

    更新日期:2012-07-01 00:00:00

  • Time domain parameters can be estimated with less statistical error than frequency domain parameters in the analysis of heart rate variability.

    abstract:INTRODUCTION:Measures of heart rate variability (HRV) can be divided in time domain and frequency domain parameters. It is frequently ignored that estimation of frequency-domain parameters is a 2-step procedure where statistical error from the first step (spectral estimation) is neglected in subsequent analyses. METHO...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2008.02.014

    authors: Kuss O,Schumann B,Kluttig A,Greiser KH,Haerting J

    更新日期:2008-07-01 00:00:00

  • Variant forms of AV and VA conduction in the canine heart.

    abstract::In 19 pentobarbital anesthetized dogs subjected to right thoracotomy, plunge wire and catheter electrodes were positioned to record and pace from the high right atrium, coronary sinus os, aortic root (for His bundle electrograms), and the right ventricular outflow tract and apex. A deflectable-tip catheter electrode w...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:

    authors: Scherlag BJ,Munsif A,Nakagawa H,Hirao K,Lazzara R

    更新日期:1993-01-01 00:00:00

  • Noninvasive risk stratification in postinfarction patients with severe left ventricular dysfunction and methodology of the MADIT II noninvasive electrocardiology substudy.

    abstract::Sudden cardiac death occurs as a result of a complex interplay of changes in myocardial substrate, imbalance of autonomic regulation of the heart, and myocardial vulnerability. Noninvasive electrocardiology serves as a comprehensive tool for investigating factors representing mechanistic pathways leading to cardiac ev...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.jelectrocard.2003.09.022

    authors: Zareba W,Moss AJ

    更新日期:2003-01-01 00:00:00

  • Using body surface mapping to detect vulnerability to ventricular arrhythmias in patients with coronary artery disease.

    abstract::In order to examine the clinical usefulness of the vulnerability map, body surface mapping was performed in ten normal subjects and 32 patients with CAD using dipyridamole infusion to induce ventricular arrhythmias. A vulnerability map and the vulnerability index (VI) proposed by Urie et al. were constructed from QRS ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(87)80100-0

    authors: Yasumura S,Kubota I,Ikeda K,Tsuiki K,Yasui S

    更新日期:1987-04-01 00:00:00

  • Transfer of coupling of premature ventricular contractions to an ectopic ventricular tachycardia: a mechanism for atypical bidirectional tachycardia.

    abstract::Bidirectional tachycardia was observed on Holter tracings recorded from a dog three days after the production of a small freeze lesion on the wall of the left ventricle. A bigeminal rhythm with fixed coupling of ventricular premature contractions was interrupted by a burst of ventricular tachycardia of different morph...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(79)80046-1

    authors: Klein GJ,Wallace AG,Gallagher JJ

    更新日期:1979-01-01 00:00:00

  • PR depression with multi‑lead ST elevation and ST depression in aVR: Is it always acute pericarditis?

    abstract::The classic electrocardiographic (ECG) manifestation of stage I of acute pericarditis is diffuse ST elevation and PR depression with ST depression in lead aVR. One of the most common conditions, that is often confused with acute pericarditis, is the benign diffuse ST elevation, termed "early repolarization with ST ele...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2019.01.085

    authors: Birnbaum Y,Perez Riera AR,Nikus K

    更新日期:2019-01-01 00:00:00

  • Electrocardiographic patterns of patients with echocardiographically determined biventricular hypertrophy.

    abstract::The numerous criteria proposed for the electrocardiographic (ECG) diagnosis of biventricular hypertrophy (BVH) suffer from inadequate correlative data. We used two-dimensional (2D) echocardiography to identify BVH and analyzed the ECG patterns in these patients. The study group had 69 such patients with BVH and the co...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:

    authors: Jain A,Chandna H,Silber EN,Clark WA,Denes P

    更新日期:1999-07-01 00:00:00

  • ST-segment deviation pattern of takotsubo cardiomyopathy similar to acute pericarditis: diffuse ST-segment elevation.

    abstract:BACKGROUND:Possible similarities or differences in the ST- and PR-segment deviations in the electrocardiogram of takotsubo cardiomyopathy (TTC) and acute pericarditis (AP) are not well defined. METHODS:We compared different parameters of the admission electrocardiogram in eight patients with TTC and eight patients wit...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2012.11.013

    authors: Zhong-qun Z,Chong-quan W,Sclarovsky S,Nikus KC,Chao-rong H,Shan M

    更新日期:2013-03-01 00:00:00

  • Epicardial ablation of right pulmonary artery ganglionated plexi for the prevention of atrial fibrillation originating in the pulmonary veins.

    abstract:UNLABELLED:PROBLEM PRESENTED: A novel study of catheter ablation of the right pulmonary artery ganglionated plexi (RPA GP) to reduce atrial fibrillation (AF) originating in the pulmonary veins (PVs) is presented. STUDIES UNDERTAKEN:In 20 dogs, atrial effective refractory periods (AERPs), PVERP, and the dispersion of A...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2010.03.007

    authors: Wang H,Li J,Hong C,Liu X,Shang F,He Y,Wang Z,Zheng Q

    更新日期:2010-07-01 00:00:00

  • Prognostic value of heart rate variability in patients with hypertrophic cardiomyopathy.

    abstract::Hypertrophic cardiomyopathy (HCM) have been reported to display impaired heart rate variability, although little is known regarding its prognostic value. By using fast Fourier transformation of 24-hour Holter recordings in 73 HCM patients at a stable clinical condition, we computed 4 spectral components: very low freq...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2003.08.005

    authors: Kawasaki T,Azuma A,Sakatani T,Hadase M,Kamitani T,Kawasaki S,Kuribayashi T,Sugihara H

    更新日期:2003-10-01 00:00:00

  • Predictors of in-hospital ventricular fibrillation or torsades de pointes in patients with acute symptomatic bradycardia.

    abstract::Severe bradyarrythmias remain as an important cause for hospital urgent admission and these patients can suffer potentially lethal complications (such as ventricular fibrillation [VF] and torsades de pointes [TdP]) between hospital admission and final therapy. Incidence and predictors of these tachyarrhythmias have no...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2003.10.003

    authors: Díaz-Castro O,Puchol A,Almendral J,Torrecilla EG,Arenal A,Martínez-Selles M

    更新日期:2004-01-01 00:00:00

  • Accuracy in clinical arrhythmia detection of a real-time Holter system (Oxford Medilog 4500).

    abstract::The accuracy of a real-time analysis Holter system (Oxford Medilog 4500) in detecting ventricular and supraventricular arrhythmias was evaluated. Hand-counted data from randomly selected hours of 152 ECG monitorings of 152 patients were used as the control standard. Accuracy of the system was evaluated on 606 hours fo...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/0022-0736(90)90119-m

    authors: Lanza GA,Lucente M,Rebuzzi AG,Cortellessa MC,Tamburi S,Mancuso P,Neri R,Manzoli U

    更新日期:1990-10-01 00:00:00

  • Recovery time dispersion measured by body surface mapping: noninvasive method of assessing vulnerability to ventricular tachyarrhythmias.

    abstract::To assess the significance of recovery time (RT) dispersion measured by body surface mapping, we investigated body surface RT isochrone maps of 40 patients with anterior old myocardial infarction (OMI), 40 patients with dilated cardiomyopathy (DCM), and 40 controls. Among the OMI and DCM groups, 20 patients per group ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1054/jelc.2001.23358

    authors: Nirei T,Kasanuki H

    更新日期:2001-04-01 00:00:00

  • Temporary unipolar pacing using a dual cathode.

    abstract::Using standard biopolar, temporary pacing catheters, thresholds were measured in four configurations: (1) bipolar (distal electrode negative, proximal electrode positive); (2) distal unipolar (distal electrode negative, right arm electrode positive); (3) proximal unipolar (proximal electrode negative, right arm electr...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(76)80077-5

    authors: Preston TA

    更新日期:1976-04-01 00:00:00

  • Detection of myocardial ischemia due to clinically asymptomatic coronary artery stenosis at rest using supervised artificial intelligence-enabled vectorcardiography - A five-fold cross validation of accuracy.

    abstract:BACKGROUND:Coronary artery disease (CAD) is a leading cause of death and disability. Conventional non-invasive diagnostic modalities for the detection of stable CAD at rest are subject to significant limitations: low sensitivity, and personal expertise. We aimed to develop a reliable and time-cost efficient screening t...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2019.12.018

    authors: Braun T,Spiliopoulos S,Veltman C,Hergesell V,Passow A,Tenderich G,Borggrefe M,Koerner MM

    更新日期:2020-01-01 00:00:00

  • Extra AV nodal Wenckebach periodicity.

    abstract::Extra AV nodal Wenckebach periodicity was diagnosed in seven patients. The most frequent form of this conduction abnormality was an exit block. The underlying block was localized in the sinoatrial junction and in the atria in two patients; the AV junction and the ventricle were the site of the Wenckebach periodicity i...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(81)80003-9

    authors: Schweitzer P,Choudhry M,Kunkes SH,Ress R,Mark H

    更新日期:1981-07-01 00:00:00

  • Clinical alarm hazards: a "top ten" health technology safety concern.

    abstract::For the past several years ECRI Institute has published a list of Top Ten Health Technology Hazards. This list is based on ECRI's extensive research in health technology safety and on data provided to its problemreporting systems. For every year that the Top Ten list has been published, Alarm Hazards have been at or n...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.jelectrocard.2012.08.050

    authors: Keller JP Jr

    更新日期:2012-11-01 00:00:00

  • Performance of seven ECG interpretation programs in identifying arrhythmia and acute cardiovascular syndrome.

    abstract:BACKGROUND:No direct comparison of current electrocardiogram (ECG) interpretation programs exists. OBJECTIVE:Assess the accuracy of ECG interpretation programs in detecting abnormal rhythms and flagging for priority review records with alterations secondary to acute coronary syndrome (ACS). METHODS:More than 2,000 di...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2019.11.043

    authors: De Bie J,Martignani C,Massaro G,Diemberger I

    更新日期:2020-01-01 00:00:00

  • Alterations in the QRS complex in the offspring of patients with metabolic syndrome and diabetes mellitus: early evidence of cardiovascular pathology.

    abstract:OBJECTIVE:This study was undertaken to evaluate the nature and onset of changes in the QRS complex in the offspring of patients with diabetes mellitus (DM) and metabolic syndrome (MetS). METHODS AND METHODS:A total of 529 subjects, divided into 5 groups, were included in the study: (i) group DM (n = 92), patients with...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2012.02.004

    authors: Bacharova L,Krivosikova Z,Wsolova L,Gajdos M

    更新日期:2012-05-01 00:00:00

  • On the potential of the Wilson central terminal with respect to an ideal reference for unipolar electrocardiography.

    abstract::Body surface potential mapping was performed in 60 clinical cases and an ideal 0 potential was calculated in each case at 2msec intervals, which corresponds to the potential at infinity. Maximal deviation of the Wilson terminal voltage the ideal potential was 0.14mv on the average. Time course of potential variations ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(05)80054-8

    authors: Miyamoto N,Shimizu Y,Nishiyama G,Mashima S,Okamoto Y

    更新日期:1995-10-01 00:00:00

  • Electrocardiographic estimation of successful ablation site in patients with manifest inferior paraseptal accessory pathway.

    abstract::Inferior paraseptal accessory pathways (APs) have a wide distribution and prediction of AP location before radiofrequency ablation is very important in such pathways. We aimed to estimate successful ablation site based on electrocardiogram in 137 patients (mean age: 25.8±9.0; 126 males) with single manifest inferior p...

    journal_title:Journal of electrocardiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jelectrocard.2015.12.017

    authors: Kabul HK,Ulus T,Barcın C,Unlu M,Samedli S,Kose S

    更新日期:2016-03-01 00:00:00