Effect of chronic idiopathic low back pain on the kinetic gait characteristics in different foot masks.

Abstract:

:Identification of kinetic variables in different masks of foot is important for the evaluation and treatment of chronic low back pain. The aim of this study was to investigate the effect of chronic idiopathic low back pain on kinetic variables of gait in different foot masks. 11 idiopathic chronic low back pain patients and 13 healthy matched controls participated in this study. Using Emed foot-scanner system, the ground reaction force and impulse were measured during barefoot normal walking. Then, the average footprints were divided into 10 masks using the Automask program and the data were extracted using Multimask Evaluation programs. The low back pain disability was measured by Quebec questionnaire. Our results revealed that the ground reaction force and impulse in medial and lateral midfoot and hallux masks of patients were significantly lower than controls. Furthermore, these patients demonstrated greater ground reaction force and impulse in 3-5th metatarsals mask than control group. There was a significant interaction between the low back pain and the foot masks factors. In conclusion, the ground reaction forces and impulses in different areas of foot are affected by low back pain. Therefore, the kinetic gait analysis should be considered as an appropriate tool in evaluation and prescribing proper treatment program in low back pain patients.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Yazdani S,Dizji E,Alizadeh F,Hassanlouei H

doi

10.1016/j.jbiomech.2018.08.013

subject

Has Abstract

pub_date

2018-10-05 00:00:00

pages

243-247

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30680-8

journal_volume

79

pub_type

杂志文章
  • Temporal changes of mechanical signals and extracellular composition in human intervertebral disc during degenerative progression.

    abstract::In this study, a three-dimensional finite element model was used to investigate the changes in tissue composition and mechanical signals within human lumbar intervertebral disc during the degenerative progression. This model was developed based on the cell-activity coupled mechano-electrochemical mixture theory. The d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.09.004

    authors: Zhu Q,Gao X,Gu W

    更新日期:2014-11-28 00:00:00

  • Extracellular NO signalling from a mechanically stimulated osteocyte.

    abstract::Bone remodelling is a dynamic process that requires the coordinated interaction of osteocytes, osteoblasts, and osteoclasts, collaborating in basic multicellular units (BMUs). Communication between these cells can be by extracellular soluble molecules as well as directly propagating intercellular signalling molecules....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.015

    authors: Vatsa A,Smit TH,Klein-Nulend J

    更新日期:2007-01-01 00:00:00

  • The exoskeletal structure and tensile loading behavior of an ant neck joint.

    abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.053

    authors: Nguyen V,Lilly B,Castro C

    更新日期:2014-01-22 00:00:00

  • Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes.

    abstract::How small do pressure transducers need to be in order to faithfully measure the plantar pressure profiles (PPPs) under normal and diabetic feet? In this study, pressures were collected from five diabetic and six non-diabetic subjects using a commercial measurement system with 25 mm2 transducers. Discrete Fourier Trans...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00116-6

    authors: Davis BL,Cothren RM,Quesada P,Hanson SB,Perry JE

    更新日期:1996-07-01 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00

  • A constitutive model for vascular tissue that integrates fibril, fiber and continuum levels with application to the isotropic and passive properties of the infrarenal aorta.

    abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.015

    authors: Martufi G,Gasser TC

    更新日期:2011-09-23 00:00:00

  • Explicit calibration method and specific device designed for stereoradiography.

    abstract::The three-dimensional geometry of the human spine is noteworthy information that can be obtained by stereoradiographic methods. These methods are based on the identification of anatomical structures in several views which are obtained by rotation of a patient standing on a turntable. Calibration algorithms for compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00016-2

    authors: Dumas R,Mitton D,Laporte S,Dubousset J,Steib JP,Lavaste F,Skalli W

    更新日期:2003-06-01 00:00:00

  • Comparison of different state space definitions for local dynamic stability analyses.

    abstract::Measures of local dynamic stability, such as the local divergence exponent (lambda*(s)) quantify how quickly small perturbations deviate from an attractor that defines the motion. When the governing equations of motion are unknown, an attractor can be reconstructed by defining an appropriate state space. However, stat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.015

    authors: Gates DH,Dingwell JB

    更新日期:2009-06-19 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension.

    abstract::Incisional hernia development is a significant complication after laparoscopic abdominal surgery. Intra-abdominal pressure (IAP) is known to initiate the extrusion of intestines through the abdominal wall, but there is limited data on the mechanics of IAP generation and the structural properties of rectus sheath. This...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.009

    authors: Lyons M,Winter DC,Simms CK

    更新日期:2014-06-03 00:00:00

  • Characterizing gait induced normal strains in a murine tibia cortical bone defect model.

    abstract::The critical role that mechanical stimuli serve in mediating bone repair is recognized but incompletely understood. Further, previous attempts to understand this role have utilized application of externally applied mechanical loads to study the tissue's response. In this project, we have therefore endeavored to capita...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.030

    authors: Prasad J,Wiater BP,Nork SE,Bain SD,Gross TS

    更新日期:2010-10-19 00:00:00

  • Hamstring muscle kinematics and activation during overground sprinting.

    abstract::Hamstring muscle strain injury is one of the most commonly seen injuries in sports such as track and field, soccer, football, and rugby. The purpose of this study was to advance our understanding of the mechanisms of hamstring muscle strain injuries during over ground sprinting by investigating hamstring muscle-tendon...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.005

    authors: Yu B,Queen RM,Abbey AN,Liu Y,Moorman CT,Garrett WE

    更新日期:2008-11-14 00:00:00

  • Exercise-induced hyperthermia as a possible mechanism for tendon degeneration.

    abstract::Mathematical modelling of tendon thermodynamics predicted that the temperature of the central core of the equine superficial digital flexor tendon would plateau at 11 degrees C above the tendon surface temperature during a sustained gallop. A mean temperature differential (between tendon core and surface) of 5.4 (S.E....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90262-3

    authors: Wilson AM,Goodship AE

    更新日期:1994-07-01 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture.

    abstract::To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.003

    authors: Han HC,Marita S,Ku DN

    更新日期:2006-01-01 00:00:00

  • 3D kinematic and dynamic analysis of the front crawl tumble turn in elite male swimmers.

    abstract::The aim of this study was to identify kinematic and dynamic variables related to the best tumble turn times (3mRTT, the turn time from 3-m in to 3-m out, independent variable) in ten elite male swimmers using a three-dimensional (3D) underwater analysis protocol and the Lasso (least absolute shrinkage and selection op...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.043

    authors: Puel F,Morlier J,Avalos M,Mesnard M,Cid M,Hellard P

    更新日期:2012-02-02 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Sensitivity analysis of muscle properties and impact parameters on head injury risk in American football.

    abstract::Head injuries frequently occur in American football and other contact sports. Uncertainty on the effects of cervical muscle properties on head injury risk may be due to the limitations of previous observational studies. This simulation study employs a musculoskeletal model of the head and neck to investigate the effec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109411

    authors: Mortensen JD,Vasavada AN,Merryweather AS

    更新日期:2020-02-13 00:00:00

  • Right ventricle in hypoplastic left heart syndrome exhibits altered hemodynamics in the human fetus.

    abstract::Hypoplastic left heart syndrome (HLHS) represents approximately 9% of all congenital heart defects and is one of the most complex, with the left side of the heart being generally underdeveloped. Numerous studies demonstrate that intracardiac fluid flow patterns in the embryonic and fetal circulation can impact cardiac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110035

    authors: Zebhi B,Wiputra H,Howley L,Cuneo B,Park D,Hoffman H,Gilbert L,Yap CH,Bark D Jr

    更新日期:2020-11-09 00:00:00

  • Sensitivity of ACL volume and T2∗ relaxation time to magnetic resonance imaging scan conditions.

    abstract::Anterior cruciate ligament (ACL) volume and T2∗ relaxation times from magnetic resonance (MR) images have been previously shown to predict the structural properties of healing ligaments. We investigated whether MR imaging scan resolution and condition (in vivo, in situ, or ex vivo) affected ACL volume and T2∗ relaxati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.03.010

    authors: Beveridge JE,Walsh EG,Murray MM,Fleming BC

    更新日期:2017-05-03 00:00:00

  • Identification of intrinsic and reflexive contributions to low-back stiffness: medium-term reliability and construct validity.

    abstract::This study aimed at testing the reliability and construct validity of a trunk perturbation protocol (TPP) that estimates the intrinsic and reflexive contributions to low-back stiffness. The TPP consists of a series of pseudorandom position-controlled trunk perturbations in an apparatus measuring forces and displacemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.036

    authors: Larivière C,Ludvig D,Kearney R,Mecheri H,Caron JM,Preuss R

    更新日期:2015-01-21 00:00:00

  • A technique for the tensile testing of demineralised bone.

    abstract::The purpose of this study was to devise a method for the tensile testing of the organic component of demineralised bone. It was hoped that the method could be applied to determine whether an observed reduction in the strength of bone in copper-deficient rats could be attributed to a reduction in the cross-linking of c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90365-l

    authors: Jonas J,Burns J,Abel EW,Cresswell MJ,Strain JJ,Paterson CR

    更新日期:1993-03-01 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Effects of sagittal postural adjustments on seat reaction load.

    abstract::Wheelchair-dependent subjects often adopt a passive sitting posture and suffer from sitting acquired pressure ulcers (PU) that mainly occur when high buttock pressures sustain for a longer period of time. Body posture directly influences seating load and proper postural change is therefore essential. Many subjects can...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.04.012

    authors: van Geffen P,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-07-19 00:00:00

  • Monitoring of fracture healing by lateral and axial vibration analysis.

    abstract::The ability to monitor the healing of bone fractures is crucially important in their treatment. The aim of the present study was to develop and validate an objective method for monitoring fracture healing based on bone vibrational response. An analytic model was formulated, with which the mechanical parameters at the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90060-g

    authors: Nikiforidis G,Bezerianos A,Dimarogonas A,Sutherland C

    更新日期:1990-01-01 00:00:00

  • Mathematical modeling of the stress strain-strain rate behavior of bone using the Ramberg-Osgood equation.

    abstract::The Ramberg-Osgood equation is used to model the viscoplastic properties of compact bone. Because of the exponential nature of this equation a special optimization technique is used to curve fitting. Results are presented for the application of this equation to three sets of strain rate dependent stress-strain curves ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90076-3

    authors: Hight TK,Brandeau JF

    更新日期:1983-01-01 00:00:00

  • Simple method for measuring center of mass work during field running.

    abstract::The purpose of this study was to propose and validate a new simple method for calculation of center of mass work during field running, in order to avoid the use of costly and inconvenient measurement devices. This method relies on spring-mass model and measurements of average horizontal velocity, and contact and fligh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109369

    authors: Devise M,Rossi J,Théveniau N,Belli A

    更新日期:2019-12-03 00:00:00

  • Accuracy of an optical active-marker system to track the relative motion of rigid bodies.

    abstract::The measurement of relative motion between two moving bones is commonly accomplished for in vitro studies by attaching to each bone a series of either passive or active markers in a fixed orientation to create a rigid body (RB). This work determined the accuracy of motion between two RBs using an Optotrak optical moti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.01.017

    authors: Maletsky LP,Sun J,Morton NA

    更新日期:2007-01-01 00:00:00

  • Serial manipulator functional calibration for in vitro biomechanical testing.

    abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.017

    authors: Hill I,Banks S

    更新日期:2014-01-03 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00