The value of 99mTc-MDP bone SPECT/CT in evaluation of patients with painful knee prosthesis.

Abstract:

OBJECTIVE:The purpose of this study was to assess the incremental value of technetium-99m-methyl diphosphonate (Tc-MDP) single-photon emission computed tomography/computed tomography (SPECT/CT) over Tc-MDP two-phase bone scan (TPBS) in the assessment of the patients with pain following knee arthroplasty. PATIENTS AND METHODS:Tc-MDP TPBS and Tc-MDP SPECT/CT were performed in 49 patients with knee pain after knee arthroplasty. The scans were reviewed by two readers (nuclear medicine physician and musculoskeletal radiologist). Tc-MDP SPECT/CT studies were interpreted in conjunction with TPBS in this retrospective study to identify the pain generator in painful knee prosthesis. The final diagnosis was established based on a combination of histopathological/cytological findings, other imaging findings (e.g. MRI, radiolabelled white scan), clinical decisions, and management outcomes (including subsequent intraoperative findings). RESULTS:In diagnosing infection or aseptic loosening, a definitive outcome regarding the presence/absence of aseptic loosening or periprosthetic infection was obtained in 41 patients. (a) Sensitivity of Tc-MDP SPECT/CT [100%; 95% confidence interval (CI): 66.4-100%] was higher than Tc-MDP TPBS (88.9%; 95% CI: 51.8-99.7%). (b) Specificity of Tc-MDP SPECT/CT (75%; 95% CI: 53.3-90.2%) was considerably higher than Tc-MDP TPBS (30%; 95% CI: 11.9-54.3%). Alternative diagnoses were identified in 21/49 (43%) patients on Tc-MDP SPECT/CT, which could not be ascertained on Tc-MDP TPBS alone. CONCLUSION:Tc-MDP SPECT/CT has better sensitivity and specificity compared with Tc-MDP TPBS in diagnosis of aseptic loosening and periprosthestic infection in patients with painful knee arthroplasty. Tc-MDP SPECT/CT identified alternative causes of pain in 43% of patients, which was not identified by Tc-MDP TPBS.

journal_name

Nucl Med Commun

authors

Mandegaran R,Agrawal K,Vijayanathan S,Gnanasegaran G

doi

10.1097/MNM.0000000000000825

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

397-404

issue

5

eissn

0143-3636

issn

1473-5628

journal_volume

39

pub_type

杂志文章
  • Large variations occur in bone density measurements of children when using different software.

    abstract:BACKGROUND:Paediatric dual X-ray absorptiometry (DXA) studies present a number of technical problems. One of these is that the edge detection algorithms designed for the adult skeleton may fail for paediatric studies. Hologic provide alternative algorithms for low bone density studies. AIM:To assess low-density softwa...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200506000-00002

    authors: Simpson DE,Dontu VS,Stephens SE,Archbold LJ,Lowe V,O'Doherty MJ,Martin N,Coakley AJ

    更新日期:2005-06-01 00:00:00

  • Short-term and long-term monitoring of the serum level of TPA after radical resection of gastrointestinal or lung cancer.

    abstract::Radically operated tumour patients (gastrointestinal cancer, n = 10; lung cancer, n = 10) were subjected to continuous prospective monitoring of the serum level of tissue polypeptide antigen (TPA) prior to surgical treatment as well as during the subsequent year. The following observations were made: Immediately after...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198602000-00007

    authors: Bauer T,Muhrer KH,Müller H,Grebe SF

    更新日期:1986-02-01 00:00:00

  • Extraction of arterial input function for measurement of brain perfusion index with 99mTc compounds using fuzzy clustering.

    abstract::Cerebral blood flow (CBF) can be quantified non-invasively using the brain perfusion index (BPI) determined from radionuclide angiographic data generated with 99mTc-hexamethylpropylene amine oxime (99mTc-HMPAO). When measuring the BPI, manual drawing of regions of interest (ROIs) (manual ROI method) for the extraction...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200403000-00014

    authors: Murase K,Nagayoshi M,Uenishi Y,Kawamata M,Yamazaki Y,Takasawa M,Oku N,Hatazawa J

    更新日期:2004-03-01 00:00:00

  • Cytotoxicity of 213Bi- and 225Ac-immunoconjugates.

    abstract::This paper describes in vitro cytotoxicity experiments with 213Bi- and 225Ac-immunoconjugates on the human epidermoid tumour cell line A431 using a blood group A-reactive murine IgG (2D11) as the specific antibody and MOPC 21 as the control antibody. With both radionuclides, specific cell-killing was achieved. The obs...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199506000-00009

    authors: Kaspersen FM,Bos E,Doornmalen AV,Geerlings MW,Apostolidis C,Molinet R

    更新日期:1995-06-01 00:00:00

  • Intravenous administration of morphine sulfate in hepatobiliary imaging for acute cholecystitis: a review of clinical efficacy.

    abstract::Morphine sulfate has been used by several investigators in the cholescintigraphic diagnosis of acute cholecystitis. A review of the available literature indicates that morphine sulfate significantly reduces the total time required for the hepatobiliary examination, while retaining both high sensitivity (98.8%) and spe...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-198803000-00005

    authors: Vasquez TE,Rimkus DS,Pretorius HT,Greenspan G

    更新日期:1988-03-01 00:00:00

  • Evaluation of renal function following treatment with extracorporeal shock wave lithotripsy (ESWL): the use of whole-kidney, parenchymal and pelvic transit times.

    abstract::The aim of this prospective study was to assess the efficacy of using whole-kidney, mean parenchymal and pelvic transit times to evaluate renal function following treatment with extracorporeal shock wave lithotripsy (ESWL). Fifteen patients were evaluated 24-48 h before and after ESWL therapy using 99Tcm-DTPA renal sc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199802000-00010

    authors: Ilgin N,Iftehar SA,Vural G,Bozkirli I,Gokcora N

    更新日期:1998-02-01 00:00:00

  • Analysis of the early blood kinetics of 99mTc-GSA and its verification: new one-compartment model and regression equation.

    abstract::Technetium-99m-galactosyl human serum albumin (99mTc-GSA) is a radiopharmaceutical that binds to asialoglycoprotein receptors in the hepatocyte membrane; the level of 99mTc-GSA accumulation in the liver correlates well with the parameters of hepatic function tests. We hypothesized that the early blood kinetics of 99mT...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200107000-00008

    authors: Sugai Y,Komatani A,Hosoya T,Takahashi K

    更新日期:2001-07-01 00:00:00

  • Preparation of radioactive praseodymium oxide as a multifunctional agent in nuclear medicine: expanding the horizons of cancer therapy using nanosized neodymium oxide.

    abstract:OBJECTIVE:Many studies have attempted to assess the significance of the use of the β(-)particle emitter praseodymium-142 ((142)Pr) in cancer treatment. As praseodymium oxide (Pr(2)O(3)) powder is not water soluble, it was dissolved in HCl solution and the resultant solution had to be pH adjusted to be in an injectable ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32835aa7bd

    authors: Bakht MK,Sadeghi M,Ahmadi SJ,Sadjadi SS,Tenreiro C

    更新日期:2013-01-01 00:00:00

  • Performance of two new solid-phase ligand assays for TSH using monoclonal antibodies.

    abstract::Three ligand assays for TSH using monoclonal antibodies, an IRMA, an ELISA and a DELFIA were compared with a standard DAB RIA technique. The IRMA proved to be superior in respect to sensitivity, precision, reproducibility and practicality. The highest sensitivity yet, was achieved by DELFIA. IRMA, ELISA and DELFIA are...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198504000-00003

    authors: Böttger I,Pabst HW,Senekowitsch R,Kriegel H

    更新日期:1985-04-01 00:00:00

  • The impact of radiopharmaceutical particle size on the visualization and identification of sentinel nodes in breast cancer.

    abstract:OBJECTIVES:The aim of this study was to compare the success rate in lymphatic mapping and sentinel node biopsy in breast cancer using two radiopharmaceuticals. METHODS:The study included 119 breast cancer patients who underwent lymphoscintigraphy after a single intratumoral injection of 99mTc-labelled human albumin co...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200403000-00004

    authors: Leidenius MH,Leppänen EA,Krogerus LA,Smitten KA

    更新日期:2004-03-01 00:00:00

  • Molecular PET and PET/CT imaging of tumour cell proliferation using F-18 fluoro-L-thymidine: a comprehensive evaluation.

    abstract::Positron emission tomography (PET) using F-18 fluoro-3'-deoxy-3-L-fluorothymidine (FLT) offers noninvasive assessment of cell proliferation in vivo. The most important application refers to the evaluation of tumour proliferative activity, representing a key feature of malignancy. Most data to date suggest that FLT is ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0b013e32832ee93b

    authors: Barwick T,Bencherif B,Mountz JM,Avril N

    更新日期:2009-12-01 00:00:00

  • In vivo kinetics of 123I-labelled insulin: studies in normal subjects and patients with diabetes mellitus.

    abstract::Radioactive tracer techniques using 131I- and 125I-insulin have been applied to study insulin metabolism. A simple method to label human insulin with 123I to a high specific activity is described. We have used this radiotracer to study insulin kinetics in vivo in normal subjects and in two groups of diabetic patients....

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198710000-00003

    authors: Sinclair AJ,Signore A,Bomanji J,Britton KE,Pozzilli P,Gale EA

    更新日期:1987-10-01 00:00:00

  • Reliability of left ventricular ejection fraction calculated with gated myocardial perfusion single photon emission computed tomography in patients with extensive perfusion defect.

    abstract:INTRODUCTION:Gated myocardial perfusion scintigraphy (g-MPS) provides functional information on the left ventricle (LV) apart from the perfusion status. Computer algorithm-based LV ejection fraction (EF) calculated from resting g-MPS has been found to be reliable in patients with normal perfusion. However, its role in ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e328342b97e

    authors: Harisankar CN,Mittal BR,Kamaleshwaran KK,Parmar M,Bhattacharya A,Singh B,Mahajan R

    更新日期:2011-06-01 00:00:00

  • Relationship between positive thyroglobulin doubling time and 18F-FDG PET/CT-positive, 131I-negative lesions.

    abstract:AIM:In patients with differentiated thyroid carcinoma (DTC), metastases can either show iodine-131 (I) uptake on whole-body scintigraphy or F-2-fluoro-2-deoxy-D-glucose (F-FDG) uptake on combined PET and X-ray computed tomography (PET/CT), or a mix of both. The present study investigates the relationship between uptake...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000025

    authors: Kelders A,Kennes LN,Krohn T,Behrendt FF,Mottaghy FM,Verburg FA

    更新日期:2014-02-01 00:00:00

  • Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: use of two independent markers and an independent arbiter.

    abstract:PURPOSE:Exclusive use of the half-time of clearance of a filtration marker in the bolus injection, single compartment technique for measuring glomerular filtration rate (GFR) is a convenient approach that gives GFR (GFR(SO)) already scaled for extracellular fluid volume (ECV). It has been criticized as less accurate th...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3281ec51b5

    authors: Bird NJ,Peters C,Michell AR,Peters AM

    更新日期:2007-09-01 00:00:00

  • Prevalence and risk factors of intraoperative identification failure of sentinel lymph nodes in patients affected by breast cancer.

    abstract:INTRODUCTION:Sentinel lymph node biopsy (SLNB) has progressively replaced complete axillary lymph node dissection in the evaluation of breast cancer patients with clinically node-negative disease. Our study investigates the rate of and risk factors involved in sentinel node identification failure. MATERIALS AND METHOD...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328361cd84

    authors: Bernardi S,Bertozzi S,Londero AP,Angione V,Petri R,Giacomuzzi F

    更新日期:2013-07-01 00:00:00

  • Propagation of measurement errors in glomerular filtration rate determination: a comparison of slope-intercept, single-sample and slope-only methods.

    abstract:BACKGROUND:Measurement errors occurring during glomerular filtration rate (GFR) studies propagate to an error in the calculated GFR. Previous work has modelled measurement errors for slope-intercept (SI-GFR), single-sample (SS-GFR) and slope-only (SO-GFR) methods. In this study, we have extended these models. The prima...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000977

    authors: Holness JL,Fleming JS,Chirehwa MT,Warwick JM

    更新日期:2019-04-01 00:00:00

  • Relationship between myocardial counts and patient weight: adjusting the injected activity in myocardial perfusion scans.

    abstract::It is generally accepted that the quality of myocardial images deteriorates with increasing patient weight. This is attributed to a reduction of counts detected from the myocardium. In this paper we have looked at the count reduction in obese patients and suggest a workable algorithm to increase the injected activity ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00006231-200301000-00015

    authors: Notghi A,Williams N,Smith N,Goyle S,Harding LK

    更新日期:2003-01-01 00:00:00

  • Improving radiopharmaceutical supply chain safety by implementing bar code technology.

    abstract::The aim of this study was to describe and evaluate an approach for improving radiopharmaceutical supply chain safety by implementing bar code technology. We first evaluated the current situation of our radiopharmaceutical supply chain and, by means of the ALARM protocol, analysed two dispensing errors that occurred in...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000177

    authors: Matanza D,Hallouard F,Rioufol C,Fessi H,Fraysse M

    更新日期:2014-11-01 00:00:00

  • Prospective evaluation of qualitative and quantitative ¹⁸F-FDG PET-CT parameters for predicting survival in recurrent carcinoma of the cervix.

    abstract:OBJECTIVE:The aim of this study was to evaluate the prognostic significance of qualitative and quantitative F-fluorodeoxyglucose (F-FDG) PET-computed tomography (PET-CT) parameters in patients with recurrent cervical carcinoma. METHODS:Twenty-six patients (age: 44 ± 10.1 years) with histologically proven recurrent car...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e3283622f0d

    authors: Maharjan S,Sharma P,Patel CD,Sharma DN,Dhull VS,Jain SK,Thulkar S,Malhotra A,Kumar R

    更新日期:2013-08-01 00:00:00

  • Dosimetric evaluation and therapeutic response to internal radiation therapy of hepatocarcinomas using iodine-131-labelled lipiodol.

    abstract:OBJECTIVE:Vectorized internal radiation therapy using lipiodol-labelled with iodine-131 (131 I-lipiodol) is an effective treatment for inoperable hepatocellular carcinomas. However, few dosimetric data are available based on this approach. We have developed a dosimetric protocol based on scintiscan imaging and that is ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32830439c6

    authors: Becker S,Laffont S,Vitry F,Rolland Y,Lecloirec J,Boucher E,Raoul JL,Herry JY,Bourguet P,Garin E

    更新日期:2008-09-01 00:00:00

  • InfuShield: a shielded enclosure for administering therapeutic radioisotope treatments using standard syringe pumps.

    abstract::The administration of radionuclide therapies presents significant radiation protection challenges. The aim of this work was to develop a delivery system for intravenous radioisotope therapies to substantially moderate radiation exposures to staff and operators. A novel device (InfuShield) was designed and tested befor...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000634

    authors: Rushforth DP,Pratt BE,Chittenden SJ,Murray IS,Causer L,Grey MJ,Gear JI,Du Y,Flux GD

    更新日期:2017-03-01 00:00:00

  • Clinical implications of the differences between diagnostic 123I and post-therapy 131I scans.

    abstract:BACKGROUND:123I has been promoted for diagnostic imaging as a means of avoiding 'stunning'. It has also been suggested that the more favourable physical characteristics and consequent enhanced imaging resolution provided by 123I offers a more accurate diagnostic assessment of the extent of disease prior to therapy. Thi...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200402000-00006

    authors: Cohen JB,Kalinyak JE,McDougall IR

    更新日期:2004-02-01 00:00:00

  • Non-invasive assessment of absolute values of hepatic haemodynamics using radiocolloid scintigraphy.

    abstract::A non-invasive technique for the assessment of hepatic haemodynamics using radiocolloid imaging with a computer, in which absolute values of hepatic, mesenteric and splenic arterial effective blood flows were assessed, is described. The technique was carried out on ten volunteers, before and after a standard meal. Aft...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198708000-00002

    authors: Walmsley BH,Fleming JS,Ackery DM,Karran SJ

    更新日期:1987-08-01 00:00:00

  • Differentiation of liver transplantation complications by quantitative analysis of dynamic hepatobiliary scintigraphy.

    abstract:OBJECTIVE:We retrospectively investigated the value of dynamic Tc-diisopropyl-iminodiacetic acid hepatobiliary scintigraphy (HBS) in discriminating postsurgical complications following liver transplantation (LT). METHODS:Dynamic HBS was performed for suspected post-LT complications in 201 cases. Hepatic uptake and exc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32834fc5e6

    authors: Lee JY,Hu W,Lee KH,Kwon CH,Lee EJ,Choi JY,Kim BT

    更新日期:2012-03-01 00:00:00

  • Is a lung perfusion scan obtained by using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism?

    abstract::Planar pulmonary scintigraphy is still regularly performed for the evaluation of pulmonary embolism (PE). However, only about 50-80% of cases can be resolved by this approach. This study evaluates the ability of tomographic acquisition (single photon emission computed tomography, SPECT) of the perfusion scan to improv...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200211000-00011

    authors: Collart JP,Roelants V,Vanpee D,Lacrosse M,Trigaux JP,Delaunois L,Gillet JB,De Coster P,Vander Borght T

    更新日期:2002-11-01 00:00:00

  • The appearance of the pyramidal lobe on thyroid scintigraphy.

    abstract::The standard nuclear medicine textbooks describe the pyramidal lobe of the thyroid as arising from the upper part of the thyroid lobes. Anatomy and surgical texts however describe it as a thyroglossal tract remnant and state that it arises from the isthmus. Review of 150 thyroid scintigrams confirms that on scintigrap...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198403000-00006

    authors: Savage PE,Khan O,Grover S,Ott R,McCready VR

    更新日期:1984-03-01 00:00:00

  • Evaluation of 90Y phosphate particles as a possible radiation synoviorthesis agent.

    abstract:BACKGROUND:90Y is one of the radioisotopes used extensively for therapy due to its favourable nuclear characteristics. Particles and colloids incorporating 90Y are being used for radiation synovectomy, especially in European countries. METHODS:In our present work, 90Y phosphate particles were prepared and evaluated fo...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200505000-00011

    authors: Pandey U,Bapat KN,Samuel G,Sarma HD,Chaudhari PR,Dhami PS,Kannan R,Venkatesh M

    更新日期:2005-05-01 00:00:00

  • 18F-FEAU as a radiotracer for herpes simplex virus thymidine kinase gene expression: in-vitro comparison with other PET tracers.

    abstract:OBJECTIVE:The herpes simplex virus thymidine kinase (HSVtk) gene has frequently been applied as a reporter gene for monitoring transgene expression in animal models. In clinical gene therapy protocols, however, extremely low expression levels of the transferred gene are generally observed. Consequently, sensitive and s...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000186609.12895.20

    authors: Buursma AR,Rutgers V,Hospers GA,Mulder NH,Vaalburg W,de Vries EF

    更新日期:2006-01-01 00:00:00

  • Could the skewness and kurtosis texture parameters of lesions obtained from pretreatment Ga-68 DOTA-TATE PET/CT images predict receptor radionuclide therapy response in patients with gastroenteropancreatic neuroendocrine tumors?

    abstract:PURPOSE:In our study, tumor heterogeneity was evaluated using the parameters skewness and kurtosis on pretreatment Ga-68 DOTA-TATE PET/CT to assess therapy responses of lesions in patients with gastroenteropancreatic neuroendocrine tumors (GEP NETs) treated with peptide receptor radionuclide therapy (PRRT). METHOD:We ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001231

    authors: Önner H,Abdülrezzak Ü,Tutuş A

    更新日期:2020-10-01 00:00:00