Loading frequencies up to 20Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic.

Abstract:

:Considering the interest of the research community in the fatigue behavior of all-ceramic restorations and the time consumed in low-frequency cyclic fatigue tests, this study aimed to investigate the influence of the loading frequency on the zirconia fatigue strength. The biaxial flexural fatigue strength of Y-TZP discs was determined by the staircase approach after 500,000 cycles. The investigated frequencies were 2Hz (control-simulation of the chewing activity; n=20), 10Hz (n=20), 20Hz (n=20), and 40Hz (n=21). The fatigue strength data were analyzed using one-way ANOVA and post-hoc Tukey׳s test (α=0.05). Pearson coefficient (r) was calculated to assess the existence of a correlation between fatigue strength and loading frequency. X-ray diffraction analysis was used to determine the relative amount of monoclinic phase under each fatigue test condition. The fatigue strength was significantly higher for 40Hz group (630.7±62.1MPa) and did not differ among the groups 2Hz (550.3±89.7MPa), 10Hz (574.0±47MPa) and 20Hz (605.1±30.7MPa). Pearson correlation coefficient indicated a significantly moderate correlation (r=0.57) between fatigue strength and loading frequency. The percentage of monoclinic phase was similar among the groups. Therefore, the use of loading frequencies up to 20Hz seems a good alternative to expedite the cycling strength fatigue tests in polycrystalline ceramics without significantly changing the fatigue behavior showed by zirconia in tests employing the frequency of the masticatory cycle.

authors

Fraga S,Pereira GKR,Freitas M,Kleverlaan CJ,Valandro LF,May LG

doi

10.1016/j.jmbbm.2016.01.008

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

79-86

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(16)00011-4

journal_volume

61

pub_type

杂志文章
  • The error of tensile strength tests and an approach for improvement.

    abstract:OBJECTIVES:The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device. MATERIAL AND METHODS:Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.003

    authors: Behr M,Fuerst J,Rosentritt M

    更新日期:2018-11-01 00:00:00

  • Micromechanical modelling of oil palm empty fruit bunch fibres containing silica bodies.

    abstract::Experimental and numerical investigation was conducted to study the micromechanics of oil palm empty fruit bunch fibres containing silica bodies. The finite viscoelastic-plastic material model called Parallel Rheological Network model was proposed, that fitted well with cyclic and stress relaxation tensile tests of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.043

    authors: Omar FN,Hanipah SH,Xiang LY,Mohammed MAP,Baharuddin AS,Abdullah J

    更新日期:2016-09-01 00:00:00

  • Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

    abstract:PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.034

    authors: Lee JT,Cho SA

    更新日期:2016-08-01 00:00:00

  • Sub-10-micrometer toughening and crack tip toughness of dental enamel.

    abstract::In previous studies, enamel showed indications to occlude small cracks in-vivo and exhibited R-curve behaviors for bigger cracks ex-vivo. This study quantifies the crack tip's toughness (K(I0),K(III0)), the crack's closure stress and the cohesive zone size at the crack tip of enamel and investigates the toughening mec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.12.003

    authors: Ang SF,Schulz A,Pacher Fernandes R,Schneider GA

    更新日期:2011-04-01 00:00:00

  • Nitinol stent design - understanding axial buckling.

    abstract::Nitinol׳s superelastic properties permit self-expanding stents to be crimped without plastic deformation, but its nonlinear properties can contribute towards stent buckling. This study investigates the axial buckling of a prototype tracheobronchial nitinol stent design during crimping, with the objective of eliminatin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.029

    authors: McGrath DJ,O Brien B,Bruzzi M,McHugh PE

    更新日期:2014-12-01 00:00:00

  • The applicability of PEEK-based abutment screws.

    abstract::The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.024

    authors: Schwitalla AD,Abou-Emara M,Zimmermann T,Spintig T,Beuer F,Lackmann J,Müller WD

    更新日期:2016-10-01 00:00:00

  • Mechanical performance of highly permeable laser melted Ti6Al4V bone scaffolds.

    abstract::Critically engineered stiffness and strength of a scaffold are crucial for managing maladapted stress concentration and reducing stress shielding. At the same time, suitable porosity and permeability are key to facilitate biological activities associated with bone growth and nutrient delivery. A systematic balance of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103517

    authors: Arjunan A,Demetriou M,Baroutaji A,Wang C

    更新日期:2020-02-01 00:00:00

  • Nanoscale characterization of dynamic cellular viscoelasticity by atomic force microscopy with varying measurement parameters.

    abstract::Cell mechanics plays an important role in regulating the physiological activities of cells. The advent of atomic force microscopy (AFM) provides a novel powerful instrument for quantifying the mechanics of single cells at the nanoscale. The applications of AFM in single-cell mechanical assays in the past decade have s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.036

    authors: Li M,Liu L,Xu X,Xing X,Dang D,Xi N,Wang Y

    更新日期:2018-06-01 00:00:00

  • Numerical study of temperature effects on the poro-viscoelastic behavior of articular cartilage.

    abstract::This paper presents a new approach to study the effects of temperature on the poro- elastic and viscoelastic behavior of articular cartilage. Biphasic solid-fluid mixture theory is applied to study the poro-mechanical behavior of articular cartilage in a fully saturated state. The balance of linear momentum, mass, and...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.023

    authors: Behrou R,Foroughi H,Haghpanah F

    更新日期:2018-02-01 00:00:00

  • Development of label-free biophysical markers in osteogenic maturation.

    abstract::The spatial and temporal changes of morphological and mechanical properties of living cells reflect complex functionally-associated processes. Monitoring these modifications could provide a direct information on the cellular functional state. Here we present an integrated biophysical approach to the quantification of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103581

    authors: Bartolozzi A,Viti F,De Stefano S,Sbrana F,Petecchia L,Gavazzo P,Vassalli M

    更新日期:2020-03-01 00:00:00

  • Damage mechanisms in uniaxial compression of single enamel rods.

    abstract::Enamel possesses a complex hierarchical structure, which bestows this tissue with unique mechanical properties. In this study, the mechanical behavior of single enamel rods was investigated under uniaxial compression. Numerical simulations were also performed using micromechanics models for individual enamel rods to i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.014

    authors: An B,Wang R,Arola D,Zhang D

    更新日期:2015-02-01 00:00:00

  • Mechanical characterization of oligo(ethylene glycol)-based hydrogels by dynamic nanoindentation experiments.

    abstract::Oligo(ethylene glycol)-based (OEG) hydrogel samples of varying cross-link densities and degrees of swelling were characterized through dynamic nanoindentation testing. Experiments were performed using a non-standard nanoindentation method, which was validated on a standard polystyrene sample. This method maximizes the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.009

    authors: Guglielmi PO,Herbert EG,Tartivel L,Behl M,Lendlein A,Huber N,Lilleodden ET

    更新日期:2015-06-01 00:00:00

  • A microstructurally-based, multi-scale, continuum-mechanical model for the passive behaviour of skeletal muscle tissue.

    abstract::This work presents a novel microstructurally-based, multi-scale model describing the passive behaviour of skeletal muscle tissue. The model is based on the detailed description of the mechanically relevant parts of the microstructure. The effective constitutive material response is obtained by a homogenisation of mech...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.012

    authors: Bleiler C,Ponte Castañeda P,Röhrle O

    更新日期:2019-09-01 00:00:00

  • Mechanical properties and thermal behaviour of PEGDMA hydrogels for potential bone regeneration application.

    abstract::Poly(ethylene glycol) hydrogels are currently under investigation as possible scaffold materials for bone regeneration. The main purpose of this research was to analyse the mechanical properties and thermal behaviour of novel photopolymerised poly(ethylene glycol) dimethacrylate (PEGDMA) based hydrogels. The effect of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.04.004

    authors: Killion JA,Geever LM,Devine DM,Kennedy JE,Higginbotham CL

    更新日期:2011-10-01 00:00:00

  • Constitutive modeling of the passive inflation-extension behavior of the swine colon.

    abstract::In the present work, we propose the first structural constitutive model of the passive mechanical behavior of the swine colon that is validated against physiological inflation-extension tests, and accounts for residual strains. Sections from the spiral colon and the descending colon were considered to investigate pote...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.031

    authors: Patel B,Chen H,Ahuja A,Krieger JF,Noblet J,Chambers S,Kassab GS

    更新日期:2018-01-01 00:00:00

  • An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch.

    abstract::An adaptive finite element simulation was developed to predict fretting wear in a head-neck taper junction of hip joint implant through a two dimensional (2D) model and based on the Archard wear equation. This model represents the most critical section of the head-neck junction which was identified from a 3D model of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.003

    authors: Fallahnezhad K,Oskouei RH,Badnava H,Taylor M

    更新日期:2017-11-01 00:00:00

  • Packing of muscles in the rabbit shank influences three-dimensional architecture of M. soleus.

    abstract::Isolated and packed muscles (e.g. in the calf) exhibit different three-dimensional muscle shapes. In packed muscles, cross-sections are more angular compared to the more elliptical ones in isolated muscles. As far as we know, it has not been examined yet, whether the shape of the muscle in its packed condition influen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.006

    authors: Wick C,Böl M,Müller F,Blickhan R,Siebert T

    更新日期:2018-07-01 00:00:00

  • Comparison of mechanical testing methods for biomaterials: Pipette aspiration, nanoindentation, and macroscale testing.

    abstract::Characterization of the mechanical properties of biological materials is often complicated by small volume, irregular geometry, fragility, and environmental sensitivity. Pipette aspiration and nanoindentation testing deal well with these limitations and have seen increasing use in biomaterial characterization, but lit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.022

    authors: Buffinton CM,Tong KJ,Blaho RA,Buffinton EM,Ebenstein DM

    更新日期:2015-11-01 00:00:00

  • Load-bearing in cortical bone microstructure: Selective stiffening and heterogeneous strain distribution at the lamellar level.

    abstract::An improved understanding of bone mechanics is vital in the development of evaluation strategies for patients at risk of bone fracture. The current evaluation approach based on bone mineral density (BMD) measurements lacks sensitivity, and it has become clear that as well as bone mass, bone quality should also be eval...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.08.016

    authors: Katsamenis OL,Chong HM,Andriotis OG,Thurner PJ

    更新日期:2013-01-01 00:00:00

  • Evaluation of the mechanical properties and degree of conversion of 3D printed splint material.

    abstract:OBJECTIVE:To evaluate the effect of post-curing method, printing layer thickness, and water storage on the mechanical properties and degree of conversion of a light-curing methacrylate based resin material (IMPRIMO® LC Splint), used for the fabrication of 3D printed occlusal splints and surgical guides. METHODS:96 bar...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104254

    authors: Perea-Lowery L,Gibreel M,Vallittu PK,Lassila L

    更新日期:2021-03-01 00:00:00

  • "Force-from-lipids" gating of mechanosensitive channels modulated by PUFAs.

    abstract::The level of fatty acid saturation in phospholipids is a crucial determinant of the biophysical properties of the lipid bilayer. Integral membrane proteins are sensitive to changes of their bilayer environment such that their activities and localization can be profoundly affected. When incorporated into phospholipids ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.026

    authors: Ridone P,Grage SL,Patkunarajah A,Battle AR,Ulrich AS,Martinac B

    更新日期:2018-03-01 00:00:00

  • Biomechanics of infarcted left Ventricle-A review of experiments.

    abstract::Myocardial infarction (MI) is one of leading diseases to contribute to annual death rate of 5% in the world. In the past decades, significant work has been devoted to this subject. Biomechanics of infarcted left ventricle (LV) is associated with MI diagnosis, understanding of remodelling, MI micro-structure and biomec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2019.103591

    authors: Li W

    更新日期:2020-03-01 00:00:00

  • Collagen tissue treated with chitosan solution in H2O/CO2 mixtures: Influence of clathrates hydrates on the structure and mechanical properties.

    abstract::A mixture of water/carbon dioxide is a "green" perspective solvent from the viewpoint of biomedical applications. Clathrate hydrates are formed this solvent under certain conditions and a very interesting question is the impact of clathrates hydrates on the structure and properties of bovine pericardium, which is used...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.11.015

    authors: Chaschin IS,Bakuleva NP,Grigoriev TE,Krasheninnikov SV,Nikitin LN

    更新日期:2017-03-01 00:00:00

  • Thermal-stress analysis of ceramic laminate veneer restorations with different incisal preparations using micro-computed tomography-based 3D finite element models.

    abstract::Main objective of this study is to investigate the thermal behavior of ceramic laminate veneer restorations of the maxillary central incisor with different incisal preparations such as butt joint and palatinal chamfer using finite element method. In addition, it is also aimed to understand the effect of different ther...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.039

    authors: Celebi AT,Icer E,Eren MM,Baykasoglu C,Mugan A,Yildiz E

    更新日期:2017-11-01 00:00:00

  • Evaluation of multi-scale mineralized collagen-polycaprolactone composites for bone tissue engineering.

    abstract::A particular challenge in biomaterial development for treating orthopedic injuries stems from the need to balance bioactive design criteria with the mechanical and geometric constraints governed by the physiological wound environment. Such trade-offs are of particular importance in large craniofacial bone defects whic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.032

    authors: Weisgerber DW,Erning K,Flanagan CL,Hollister SJ,Harley BAC

    更新日期:2016-08-01 00:00:00

  • Through-thickness stress relaxation in bacterial cellulose hydrogel.

    abstract::Biological hydrogels, e.g. bacterial cellulose (BC) hydrogel, attracted increasing interest in recent decades since they show a good potential for biomedical engineering as replacements of real tissues thanks mainly to their good biocompatibility and fibrous structure. To select potential candidates for such applicati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.021

    authors: Gao X,Kuśmierczyk P,Shi Z,Liu C,Yang G,Sevostianov I,Silberschmidt VV

    更新日期:2016-06-01 00:00:00

  • A combined experimental, modeling, and computational approach to interpret the viscoelastic response of the white matter brain tissue during indentation.

    abstract::Viscoelastic properties of the white matter brain tissue are systematically studied in this paper utilizing indentation experiments, mathematical modeling, and finite element simulation. It is first demonstrated that the internal stiffness of the instrument needs to be thoroughly obtained and incorporated in the analy...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.037

    authors: Samadi-Dooki A,Voyiadjis GZ,Stout RW

    更新日期:2018-01-01 00:00:00

  • Translucency, hardness and strength parameters of PMMA resin containing graphene-like material for CAD/CAM restorations.

    abstract::CAD/CAM restorations can be produced from several ceramic and hybrid materials. The moderate mechanical properties of PMMA based resin have hindered its use for permanent restorations. Recently, a graphene reinforced PMMA namely G-CAM has been introduced for permanent CAD/CAM restorations. Although graphene family mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103388

    authors: Agarwalla SV,Malhotra R,Rosa V

    更新日期:2019-12-01 00:00:00

  • Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications.

    abstract::The incidence of total hip arthroplasty (THA) has been evidently growing over the last few decades. Surface modification, such as polymer grafting onto implant surfaces using poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC), has been gaining attention due to its excellent biocompatibility and high lubricity beha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103412

    authors: Ghosh S,Abanteriba S,Wong S,Houshyar S

    更新日期:2019-12-01 00:00:00

  • Dynamic nanomechanical properties of novel Si-rich intermetallic coatings growth on a medical 316 LVM steel by hot dipping in a hypereutectic Al-25Si alloy.

    abstract::This aim of this study is to determine the elastoplastic properties of Ni-free Al3FeSi2 intermetallic coatings grown on medical stainless steel under different experimental conditions. Elastoplastic properties are defined by the plasticity index (PI), which correlates the hardness and the Young's modulus. Special emph...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.018

    authors: Frutos E,González-Carrasco JL

    更新日期:2015-06-01 00:00:00