Effect of powered gait orthosis on walking in individuals with paraplegia.

Abstract:

BACKGROUND:The important purpose of a powered gait orthosis is to provide active joint movement for patients with spinal cord injury. OBJECTIVES:The aim of this study was to clarify the effect of a powered gait orthosis on the kinematics and temporal-spatial parameters in paraplegics with spinal cord injury. STUDY DESIGN:Quasi-experimental. METHODS:Four spinal cord injury individuals experienced gait training with a powered gait orthosis for a minimum of 6 weeks prior to participating in the following walking trials: walking with an isocentric reciprocating gait orthosis and walking with both separate and synchronized movements with actuated orthotic hip and knee joints in a powered gait orthosis. Specific parameters were calculated and compared for each of the test conditions. RESULTS:Using separate and synchronized actuated movement of the hip and knee joints in the powered gait orthosis increased gait speed and step length and reduced lateral and vertical compensatory motions when compared to the isocentric reciprocating gait orthosis, but there were no significant differences in these parameters. Using the new powered gait orthosis improved knee and hip joint kinematics. CONCLUSIONS:The powered gait orthosis increased speed and step length as well as hip and knee joint kinematics and reduced the vertical and lateral compensatory motions compared to an isocentric reciprocating gait orthosis in spinal cord injury patients. CLINICAL RELEVANCE:This new powered gait orthosis has the potential to improve hip and knee joint kinematics, the temporal-spatial parameters of gait in spinal cord injury patients walking.

journal_name

Prosthet Orthot Int

authors

Arazpour M,Ahmadi Bani M,Kashani RV,Tabatabai Ghomshe F,Mousavi ME,Hutchins SW

doi

10.1177/0309364612463164

subject

Has Abstract

pub_date

2013-08-01 00:00:00

pages

261-7

issue

4

eissn

0309-3646

issn

1746-1553

pii

0309364612463164

journal_volume

37

pub_type

临床试验,杂志文章
  • Pedorthic management of the diabetic foot.

    abstract:BACKGROUND:Conservative pedorthic management of the diabetic foot has been shown to be an effective method to prevent ulcers, amputations, and re-amputations. This article exhibits why and how pedorthics plays such an important role via modalities such as footwear, shoe modifications, custom foot orthoses, and partial ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364614535233

    authors: Janisse D,Janisse E

    更新日期:2015-02-01 00:00:00

  • Tolerance of early walking with total contact among below-knee amputees--a randomized test.

    abstract::In order to reduce the need for repeated changes of socket due to postoperative atrophy and resorption of oedema simple temporary limbs are required to delay the casting of individual sockets until the stump is more mature. A randomized study of 95 below-knee amputees was performed with a re-usable temporary one-size ...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.3109/03093648309166980

    authors: Liedberg E,Hommerberg H,Persson BM

    更新日期:1983-08-01 00:00:00

  • Rasch analysis of the Locomotor Capabilities Index-5 in people with lower limb amputation.

    abstract::The aim of this study was to perform a Rasch analysis on the 5-level ordinal scale version of the Locomotor Capabilities Index (LCI-5), in order to investigate rating scale quality and conduct reliability and validity assessments. A questionnaire was mailed to 144 subjects who had undergone lower limb amputation (LLA)...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640701253952

    authors: Franchignoni F,Giordano A,Ferriero G,Muñoz S,Orlandini D,Amoresano A

    更新日期:2007-12-01 00:00:00

  • Variability of kinetic variables during gait in unilateral transtibial amputees.

    abstract:BACKGROUND:Prosthetic gait increases demands on stability. Some variability measures can be used to investigate the stability of movement for prosthetic feet. OBJECTIVES:The purpose of this study was to determine the influence of the prosthetic foot on ground reaction force variability for transtibial amputee gait. S...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612439572

    authors: Svoboda Z,Janura M,Cabell L,Elfmark M

    更新日期:2012-06-01 00:00:00

  • Compliance to service standards for congenital upper limb deficiency: the Northern Ireland experience.

    abstract:BACKGROUND:In 2003, the British Society of Rehabilitation Medicine (BSRM) published guidelines on amputee and prosthetic rehabilitation, including those with congenital limb deficiency. OBJECTIVES:The aim of the study was to evaluate the service provided by the Regional Disablement Service (RDS) to children with conge...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364611427070

    authors: Hillan J,Graham LE

    更新日期:2012-03-01 00:00:00

  • The effect of custom carbon ankle-foot orthosis alignment on roll-over shape and center of pressure velocity.

    abstract:BACKGROUND:Maintaining an optimal rolling of the foot over the ground is thought to increase the stability and efficiency of pathologic gait. Ankle-foot orthoses are often prescribed to improve gait mechanics in individuals with lower extremity injuries; however, their design may compromise how the foot rolls over the ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620971407

    authors: Russell Esposito E,Ruble MD,Ikeda AJ,Wilken JM

    更新日期:2020-11-21 00:00:00

  • Importance of neurological evaluation before reverse shoulder arthroplasty in patients with previous poliomyelitis.

    abstract::We present a case report of a patient, affected by post-polio syndrome and cuff tear arthropathy of his right shoulder, who underwent reverse shoulder arthroplasty. A previous radial deficiency was unmasked in the post-operative follow-up, with passive elbow bending when the forearm was put in an antigravitational pos...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802425459

    authors: Castoldi F,Lollino N,Caranzano F,Assom M

    更新日期:2009-06-01 00:00:00

  • Influence of gait training and prosthetic foot category on external work symmetry during unilateral transtibial amputee gait.

    abstract:BACKGROUND:Prosthetic foot prescription guidelines lack scientific evidence and are concurrent with an amputee's concurrent with an amputee's Medicare Functional Classification Level (K-Level) and categorization of prosthetic feet. OBJECTIVE:To evaluate the influence of gait training and four categories of prosthetic ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612473501

    authors: Agrawal V,Gailey R,O'Toole C,Gaunaurd I,Finnieston A

    更新日期:2013-10-01 00:00:00

  • Step count accuracy of StepWatch and FitBit One™ among individuals with a unilateral transtibial amputation.

    abstract:BACKGROUND:Step counts, obtained via activity monitors, provide insight into activity level in the free-living environment. Accuracy assessments of activity monitors are limited among individuals with lower-limb amputations. OBJECTIVES:(1) To evaluate the step count accuracy of both monitors during forward-linear and ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618767138

    authors: Arch ES,Sions JM,Horne J,Bodt BA

    更新日期:2018-10-01 00:00:00

  • Multichannel functional electrical stimulation--facts and expectations.

    abstract::Clinically applied multichannel stimulation was visualized in the very beginnings of FES. A short survey of existing multichannel systems was taken and compared to initial expectations. While much still remains to be done to get multichannel stimulation out of the research environment and into the clinical routine, th...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647709164605

    authors: Vodovnik L,Grobelnik S

    更新日期:1977-04-01 00:00:00

  • Adjustments to amputation and an artificial limb in lower limb amputees.

    abstract:BACKGROUND:Positive adjustments to amputation and an artificial limb play important roles in the rehabilitation process. OBJECTIVES:To study the different facets of adjustments to amputation and an artificial limb in lower limb amputees and to assess the possible role of different background and amputation-related fac...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613489332

    authors: Sinha R,van den Heuvel WJ,Arokiasamy P

    更新日期:2014-04-01 00:00:00

  • Taxonomy of clinical encounters during the first 90 days post-delivery of an initial lower limb prosthesis.

    abstract:BACKGROUND:The incidence and etiology of prosthetic services utilization is poorly understood during the first 90 days post-delivery of the initial lower limb prosthesis. This period is of critical importance, as prevailing policy dictates limits on the reimbursement for certain services provided during this time perio...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618774053

    authors: Lee DJ,Wininger M,Mahler D,Parisi M

    更新日期:2018-10-01 00:00:00

  • Evaluation of a screening and prevention programme for diabetic foot complications.

    abstract::Foot complications in diabetes can be decreased by preventive measures. The authors evaluated the current diabetic foot screening and prevention programme of the diabetes outpatient clinic of their university hospital, by assessing the presence of risk factors for the development of foot disorders and the preventive m...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640108726586

    authors: Meijer JW,Links TP,Smit AJ,Groothoff JW,Eisma WH

    更新日期:2001-08-01 00:00:00

  • Prosthetic rehabilitation of a patient with finger amputation using silicone material.

    abstract:AIM:Finger and partial finger amputations are commonly due to traumatic injuries; digit loss may also be attributed to congenital malformations and disease. Finger prostheses are difficult to fabricate as they demand both aesthetic and function. When dealing with these types of prostheses, the only method of gaining su...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614528203

    authors: Goyal A,Goel H

    更新日期:2015-08-01 00:00:00

  • Mandible reconstruction: History, state of the art and persistent problems.

    abstract:BACKGROUND:Mandibular reconstruction has been experiencing an amazing evolution. Several different approaches are used to reconstruct this bone and therefore have a fundamental role in the recovery of oral functions. OBJECTIVES:This review aims to highlight the persistent problems associated with the approaches identi...

    journal_title:Prosthetics and orthotics international

    pub_type: 历史文章,杂志文章,评审

    doi:10.1177/0309364613520032

    authors: Ferreira JJ,Zagalo CM,Oliveira ML,Correia AM,Reis AR

    更新日期:2015-06-01 00:00:00

  • 'It's . . . forward-focused': Experiences of a mobility clinic for people with limb loss.

    abstract:BACKGROUND:Mobility clinics are designed to extend gait and mobility training beyond rehabilitation programmes. No research has been undertaken into participants' experiences of attending these multidisciplinary, experience-based clinics. Research in this area is needed to ensure clinics meet intended goals, including ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364619882126

    authors: Anderson S,Chaffey L,Dillon M

    更新日期:2019-12-01 00:00:00

  • Contact force ratio: a new parameter to assess foot arch function.

    abstract::Static footprint parameters have been used to quantify arch height with conflicting results. This could be caused by the inherent inaccuracy and variations of the methodology used. Since the foot is a dynamic structure that undergoes changes during a step, it is more desirable to capture and analyse the dynamic footpr...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640408726701

    authors: Leung AK,Cheng JC,Zhang M,Fan Y,Dong X

    更新日期:2004-08-01 00:00:00

  • A series of case studies on the effect of a midfoot control ankle foot orthosis in the prevention of unresolved pressure areas in children with cerebral palsy.

    abstract::This paper reports on a series of case studies where improvements were sought in muscle tone and gait in children with cerebral palsy. A Midfoot Control Ankle Foot Orthosis (AFO) was developed to control foot position in a cohort of patients with cerebral palsy (CP). The concept of controlling midfoot and hindfoot wit...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1080/03093640108726609

    authors: Bill M,McIntosh R,Myers P

    更新日期:2001-12-01 00:00:00

  • Load on osseointegrated fixation of a transfemoral amputee during a fall: loading, descent, impact and recovery analysis.

    abstract::Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterize a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093640903585024

    authors: Frossard LA,Tranberg R,Haggstrom E,Pearcy M,Brånemark R

    更新日期:2010-03-01 00:00:00

  • The influence of orthosis stiffness on paraplegic ambulation and its implications for functional electrical stimulation (FES) walking systems.

    abstract::This study examines the evidence which supports the importance of maintaining relative abduction for effective reciprocal walking in high level paraplegic patients. In comparisons of orthoses, where this can only be achieved mechanically, those with higher lateral rigidity consistently showed greater levels of walking...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649509080352

    authors: Stallard J,Major RE

    更新日期:1995-08-01 00:00:00

  • The impact of gender, level of amputation and diabetes on prosthetic fit rates following major lower extremity amputation.

    abstract:BACKGROUND:Diabetes mellitus is a leading cause of major lower extremity amputation. OBJECTIVE:To examine the influence of gender, level of amputation and diabetes mellitus status on being fit with a prosthetic limb following lower extremity amputation for peripheral arterial disease. STUDY DESIGN:Retrospective analy...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616628341

    authors: Davie-Smith F,Paul L,Nicholls N,Stuart WP,Kennon B

    更新日期:2017-02-01 00:00:00

  • Contact dermatitis to cobalt chloride with an unusual mechanism.

    abstract:BACKGROUND:Contact dermatitis is a frequent inflammatory skin disease. A suspected diagnosis is based on clinical symptoms, a plausible contact to allergens and a suitable history of dermatitis. Therefore, careful diagnosis by patch testing is of great importance because the patch testing is important to find out which...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614534293

    authors: Arslan S,Aksan S,Ucar R,Caliskaner AZ

    更新日期:2015-10-01 00:00:00

  • Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.

    abstract::Interface pressures and shear stresses at different sagittal plane angular alignment settings were measured on 3 trans-tibial amputee subjects ambulating with patellar-tendon-bearing total contact prostheses. Substantial socket-shank angular alignment modifications in the sagittal plane had minimal effect on stance ph...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649909071607

    authors: Sanders JE,Daly CH

    更新日期:1999-04-01 00:00:00

  • Multifunctional above-knee prosthesis for stairs' walking.

    abstract::The multifunctional above-knee prosthesis WLP-7R (Waseda Leg Prosthesis - type 7 Refined) described in this study allows amputees to descend and ascend stairs with no external power sources. With the hydraulic circuit mounted in the shank, the ankle joint and the knee joint mutually conterbalance during stance phase i...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648709078198

    authors: Koganezawa K,Fujimoto H,Kato I

    更新日期:1987-12-01 00:00:00

  • Nighttime bracing with the Providence thoracolumbosacral orthosis for treatment of adolescent idiopathic scoliosis: A retrospective consecutive clinical series.

    abstract:BACKGROUND::Orthotic treatment for adolescent idiopathic scoliosis is a mainstay in nonoperative treatment to prevent progressive spinal deformity. OBJECTIVE::To determine the effectiveness of the Providence orthosis in the treatment of adolescent idiopathic scoliosis. STUDY DESIGN::Retrospective review. METHODS::Pa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618792727

    authors: Davis L,Murphy JS,Shaw KA,Cash K,Devito DP,Schmitz ML

    更新日期:2019-04-01 00:00:00

  • Development of clinical guidelines for the prescription of orthoses in patients with neurological disorders in The Netherlands.

    abstract::The objective of this study was to develop guidelines for the prescription of ankle-foot, knee, wrist-hand and elbow orthoses for patients with neurological disorders. The study is part of a more comprehensive study focusing on the development of clinical guidelines for the prescription of these orthoses in a wider pa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640500533232

    authors: Hijmans JM,Geertzen JH

    更新日期:2006-04-01 00:00:00

  • A novel technique for fabricating an ear prosthesis in a patient with congenital ear deformity.

    abstract:BACKGROUND AND AIM:Microtia is one of the forms of ear loss and deformity. A prosthesis that is simple to apply, and which has adequate suspension and acceptable aesthetics, can be useful in the rehabilitation of patients with this deficit and can improve the social and psychological effects of patients with ear amputa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612467344

    authors: Mardani MA,Aminian G,Tabatabaian F,Arazpour M,Hutchins SW,Head JS

    更新日期:2013-08-01 00:00:00

  • A study of 200 cases of congenital limb deficiencies.

    abstract::An analysis of 200 patients with congenital limb deficiency who attended the Artificial Limb Centre, Pune from January 1984 to April 1990 is presented. This group is representative of the congenital limb deficient population of the country. The commonest deficiencies were transverse phalangeal total/partial deficiency...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164402

    authors: Jain SK

    更新日期:1994-12-01 00:00:00

  • Clinical field testing of vulcanized rubber feet for trans-tibial amputees in tropical low-income countries.

    abstract::In a prospective, controlled study, 186 prosthetic rubber feet of different designs were fitted to amputees with trans-tibial prostheses. There were 158 amputees available for follow-up. The amputee compliance was good and 89% were satisfied with their device. After 18 months of use one VI-Solid rubber foot from VVAF ...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1080/03093640600794692

    authors: Steen Jensen J,Nilsen R,Zeffer J,Fisk J,Hartz C

    更新日期:2006-08-01 00:00:00

  • Scientific validation of two commercial pressure sensor systems for prosthetic socket fit.

    abstract::The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's F-Socket Pressure Measurement System, have been com...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640008726523

    authors: Polliack AA,Sieh RC,Craig DD,Landsberger S,McNeil DR,Ayyappa E

    更新日期:2000-04-01 00:00:00