Abstract:
:Static footprint parameters have been used to quantify arch height with conflicting results. This could be caused by the inherent inaccuracy and variations of the methodology used. Since the foot is a dynamic structure that undergoes changes during a step, it is more desirable to capture and analyse the dynamic footprint at an instant during the gait cycle that can most closely reflect the weight-bearing foot function. Forty (40) volunteer subjects were recruited for the reliability test of a new parameter, the Contact Force Ratio (CFR), derived from dynamic footprint. This is a measure of midfoot loading during gait. The mid-gait dynamic footprints were collected using a pressure sensing mat. Results of ICC tests showed that the CFR had good intratester (0.918) and intertester (0.909) reliability. The validity of the method was examined by correlating the parameter to the functional change in arch height, i.e. the Navicular Drop between the non-weight-bearing and weight-bearing conditions.
journal_name
Prosthet Orthot Intjournal_title
Prosthetics and orthotics internationalauthors
Leung AK,Cheng JC,Zhang M,Fan Y,Dong Xdoi
10.1080/03093640408726701keywords:
subject
Has Abstractpub_date
2004-08-01 00:00:00pages
167-74issue
2eissn
0309-3646issn
1746-1553journal_volume
28pub_type
杂志文章abstract:BACKGROUND:Curriculum documents identify key concepts within learning prosthetics. Threshold concepts provide an alternative way of viewing the curriculum, focussing on the ways of thinking and practicing within prosthetics. Threshold concepts can be described as an opening to a different way of viewing a concept. This...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364616679317
更新日期:2017-12-01 00:00:00
abstract::If below-knee amputation is impossible, knee disarticulation should be considered before above-knee amputation, regardless of age and etiology. Knee disarticulation which leaves the femur and patella untoched offers many advantages. The surgical technique is simple and non-traumatic since no bone or muscle tissue is t...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093647909164695
更新日期:1979-04-01 00:00:00
abstract:BACKGROUND:The aim of this case study was to identify the effect of a powered hip orthosis on the kinematics and temporal-spatial parameters of walking by a patient with spinal cord injury (SCI). CASE DESCRIPTION AND METHODS:Two orthoses were evaluated while worn by an incomplete SCI subject with a T-8level of injury....
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364611431482
更新日期:2012-03-01 00:00:00
abstract::A polio victim who has been in a negative pressure ventilator ("iron lung") since 1950 was in need of an activated mattress to combat the hallucinatory effects of complete immobilization and to assist with body pressure distribution. A mechanical method was used to give the patient's mattress a moving wave form of ver...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093647809177773
更新日期:1978-08-01 00:00:00
abstract::In Europe, bespoke orthopaedic shoes are usually sent for a trial fitting in order to check the fit and indicate any modifications required before final finishing. The use of shell shoes at the fit assessment stage, rather than the traditional alternative of partially or fully finished shoes, can offer service advanta...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649509168002
更新日期:1995-12-01 00:00:00
abstract::A cheap and fast method of providing long term accommodating insoles is described. Room temperature vulcanizing (RTV) silicone rubber is used, with suitable coverings, to provide pain relief and support for feet and ankles. The combination of physical properties of the finished item provides a useful balance between s...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648409145347
更新日期:1984-04-01 00:00:00
abstract::A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is bas...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648909079421
更新日期:1989-12-01 00:00:00
abstract::Ten years after the ISPO consensus conference on amputation surgery, a search of relevant publications in the Rehabilitation-prosthetics-literature over the years 1990-2000 was performed. The main key-words in this research were: "lower limb, amputation, human and rehabilitation". One hundred and four (104) articles w...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,评审
doi:10.1080/03093640108726563
更新日期:2001-04-01 00:00:00
abstract::The casting of flexible polyurethane foam into a wide range of customised shapes has been found to offer a relatively straightforward solution to a number of problems associated with providing support for the physically handicapped. This note describes the techniques used for the production of such supports and report...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648409145359
更新日期:1984-08-01 00:00:00
abstract::The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's F-Socket Pressure Measurement System, have been com...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093640008726523
更新日期:2000-04-01 00:00:00
abstract:BACKGROUND:Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning. STUDY DESIGN:Clinical trial. OBJECTIVES:To introduce and evaluate a new simple method for measuring the pistoning between the soft liner and...
journal_title:Prosthetics and orthotics international
pub_type: 临床试验,杂志文章
doi:10.1177/0309364611423130
更新日期:2011-12-01 00:00:00
abstract::An analysis of 200 patients with congenital limb deficiency who attended the Artificial Limb Centre, Pune from January 1984 to April 1990 is presented. This group is representative of the congenital limb deficient population of the country. The commonest deficiencies were transverse phalangeal total/partial deficiency...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649409164402
更新日期:1994-12-01 00:00:00
abstract::A post-clinical investigation has been carried out among 42 unilateral amputees who lost their hand due to an accident. The investigation was directed at two main topics of interest. Firstly the amputee, the problems he has to cope with, and the role the prosthesis plays in his life; and secondly the prosthesis, its u...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648309166586
更新日期:1983-12-01 00:00:00
abstract::The authors report on a new device for the primary mobilization of a boy with severe deficiencies of all four limbs. This device allows independent mobility. ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649409164671
更新日期:1994-04-01 00:00:00
abstract::Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterize a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093640903585024
更新日期:2010-03-01 00:00:00
abstract:BACKGROUND:Few studies have explored the effects of exercise on gait performance in people with lower limb amputations. OBJECTIVES:To (1) summarize the effects of exercise programs on gait performance and (2) assess the overall quality of the evidence for adults ambulating with leg prostheses. STUDY DESIGN:Systematic...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,评审
doi:10.1177/0309364614546926
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Challenges exist with the provision of appropriate mobility assistive devices in rural areas. The use of the direct manufacturing prosthetic socket system is a possible solution to these challenges. OBJECTIVES:The objective of this study was to test and explore the clients' perspectives with the application...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364616683982
更新日期:2017-10-01 00:00:00
abstract::A mathematical model was used to investigate the dynamic behaviour of an above-knee (AK) prosthesis in the swing phase and to analyse the influence of mass and mass distribution on the maximal stump load and the required energy. The model consists of a bondgraph model of the prosthesis and a "walking" model which pred...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648709078180
更新日期:1987-08-01 00:00:00
abstract::This paper reports a study of 66 upper limb amputees in County Funen, Denmark who were visited in their homes by the author. The purpose of this study was to evaluate for the same period of time the social and economic outcome for a population of upper limb amputees compared with the normal population. The number of a...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649209164304
更新日期:1992-04-01 00:00:00
abstract:BACKGROUND:Prosthetic gait increases demands on stability. Some variability measures can be used to investigate the stability of movement for prosthetic feet. OBJECTIVES:The purpose of this study was to determine the influence of the prosthetic foot on ground reaction force variability for transtibial amputee gait. S...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364612439572
更新日期:2012-06-01 00:00:00
abstract:BACKGROUND AND AIM:It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE:A controlled laboratory study was c...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364610394478
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Reduced-stiffness components are often prescribed in lower-limb prostheses, but their efficacy in augmenting shock absorption has been inconclusive. OBJECTIVES:To perform a systematic variation of longitudinal prosthetic stiffness over a wide range of values and to evaluate its effect on shock absorption du...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364616640945
更新日期:2017-04-01 00:00:00
abstract::Gains in stump volume have been documented in trans-tibial amputees while walking in custom made under-sized, total surface-bearing, vacuum-assisted sockets (Board et al., 2001). These gains raised doubts as to whether the sockets were truly under-sized and concerns that using an over-sized socket with vacuum-assist c...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093640308726666
更新日期:2003-08-01 00:00:00
abstract:BACKGROUND:Children with cerebral palsy (CP) often demonstrate postural control difficulties. Orthotic management may assist in improving postural control in these children. OBJECTIVE:The purpose of this investigation was to examine the influence of floor reaction ankle foot orthosis (FRAFO) on postural flexion called...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364611429855
更新日期:2012-03-01 00:00:00
abstract::Since 1972 the Hyogo Rehabilitation Centre has been developing a variable-resistance-type pneumatic control device, the HRC Adjustable Pneumatic Swing-Phase Control Knee. Successful field tests have been carried out on 20 cases with Model IV since 1973 with only a limited number of mechanical troubles. This paper intr...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093647809166698
更新日期:1978-12-01 00:00:00
abstract::Orthoses which fit inside shoes have, in many cases in the past, been fashioned to the shape of the patient's foot. It is suggested that improved stability and comfort is achieved if, instead, the outside shape of the foot-piece of the orthosis is fashioned to the inside shape of the footwear. A method for achieving t...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093647909103088
更新日期:1979-08-01 00:00:00
abstract::This review presents an analytical and comparative survey of upper limb prosthesis acceptance and abandonment as documented over the past 25 years, detailing areas of consumer dissatisfaction and ongoing technological advancements. English-language articles were identified in a search of Ovid, PubMed, and ISI Web of S...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,评审
doi:10.1080/03093640600994581
更新日期:2007-09-01 00:00:00
abstract::The swing-phase motion of the shank of an above-knee prosthesis has been modelled mathematically. An inexpensive endoskeletal prosthesis was designed using the Jaipur foot and conduit pipes with a hinge joint for the knee. Results of field trials and the modelling indicate that a very simple above-knee prosthesis can ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649209164323
更新日期:1992-08-01 00:00:00
abstract::Transfer of Musculus Latissimus dorsi/M. Teres major to the rotator cuff with or without M. Subscapularis/M. Pectoralis release is a widely used procedure for restoring shoulder abduction and external rotation in squeal of obstetric brachial plexus palsy. After the operation a shoulder abduction orthosis in maximal ex...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093640802015755
更新日期:2008-06-01 00:00:00
abstract::The multifunctional above-knee prosthesis WLP-7R (Waseda Leg Prosthesis - type 7 Refined) described in this study allows amputees to descend and ascend stairs with no external power sources. With the hydraulic circuit mounted in the shank, the ankle joint and the knee joint mutually conterbalance during stance phase i...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648709078198
更新日期:1987-12-01 00:00:00