A series of case studies on the effect of a midfoot control ankle foot orthosis in the prevention of unresolved pressure areas in children with cerebral palsy.

Abstract:

:This paper reports on a series of case studies where improvements were sought in muscle tone and gait in children with cerebral palsy. A Midfoot Control Ankle Foot Orthosis (AFO) was developed to control foot position in a cohort of patients with cerebral palsy (CP). The concept of controlling midfoot and hindfoot with an encapsulated internal Supra-Malleolar AFO that fitted into an external AFO was shown to be effective in ambulant children with CP. Some initial problems of compliance were noted and postulated to be due to difficulties associated with previous orthotic devices. Evidence from the case studies suggest that the developed Supra-Malleolar AFO orthoses enables children with CP to maintain mobility without skin tissue damage, delays the need for surgery and at the same time maintains the length of the Triceps Surae (Gastrocnemius and Soleus) complex. Plans for further research are discussed which will contribute to the evidence base for this particular orthotic device.

journal_name

Prosthet Orthot Int

authors

Bill M,McIntosh R,Myers P

doi

10.1080/03093640108726609

keywords:

subject

Has Abstract

pub_date

2001-12-01 00:00:00

pages

246-50

issue

3

eissn

0309-3646

issn

1746-1553

journal_volume

25

pub_type

杂志文章,评审
  • Quality of life of persons with transfemoral amputation: Comparison of socket prostheses and osseointegrated prostheses.

    abstract:BACKGROUND:Until recently, no study had compared the quality of life of persons with transfemoral amputation treated with osseointegration to socket prosthesis users. OBJECTIVES:Comparison of quality of life in two types of prostheses users: a cohort of patients with osseointegration and patients equipped with a socke...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620948649

    authors: Pospiech PT,Wendlandt R,Aschoff HH,Ziegert S,Schulz AP

    更新日期:2020-08-25 00:00:00

  • Comparison of gait between healthy participants and persons with spinal cord injury when using the advanced reciprocating gait orthosis.

    abstract:BACKGROUND:The advanced reciprocating gait orthosis (ARGO) has a rigid structure which provides restricted movement at the hip, knee, and ankle joints and incorporates a pelvic section with an extended section in the lumbar region. Healthy subjects, when walking with an RGO in situ, could feasibly demonstrate the level...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364615592699

    authors: Arazpour M,Joghtaei M,Bahramizadeh M,Ahmadi Bani M,Hutchins SW,Curran S,Mousavi ME,Sharifi G,Mardani MA

    更新日期:2016-04-01 00:00:00

  • Preliminary experiences with modified SACH feet manufactured and used in a tropical developing world setting.

    abstract::In a prospective study of polypropylene (PP) prostheses for trans-tibial amputees four different modified SACH feet were used. These are identified as: 1. BAVI from the national manufacturer of componentry in BaVi; 2. HCMC a design initiated by the International Committee of the Red Cross (ICRC) together with the Army...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649909071641

    authors: Jensen JS,Heim S

    更新日期:1999-12-01 00:00:00

  • Technical note--test instructions for the technical testing of mono-functional myoelectrically-controlled prosthetic hands. A proposal.

    abstract::To get an acceptable standard of prostheses and orthoses in Sweden, the Swedish Institute for the Handicapped is testing this group of aids. One important part of the work is to draw up test instructions. In response to a request from the Swedish Institute for the Handicapped, the Laboratory of Rehabilitation Engineer...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648209167739

    authors: Ingvarsson B,Karlsson I,Ottosson LG,Thyberg M

    更新日期:1982-04-01 00:00:00

  • The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm.

    abstract:BACKGROUND AND AIM:DEKA Integrated Solutions Corp. (DEKA) was charged by the Defense Advanced Research Project Agency to design a prosthetic arm system that would be a dramatic improvement compared with the existing state of the art. The purpose of this article is to describe the two DEKA Arm prototypes (Gen 2 and Gen ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613506913

    authors: Resnik L,Klinger SL,Etter K

    更新日期:2014-12-01 00:00:00

  • Heel lifting as a conservative therapy for osteoarthritis of the hip: based on the rationale of Pauwels' intertrochanteric osteotomy.

    abstract::Patients with osteoarthritis of the hip were treated with a conservative therapy of heel lifting. Orthoses were applied on 35 hips in 33 subjects and the cases were followed for 23 months on average. Dramatic pain relief was reported, but the time required to reduce or completely relieve pain increased according to th...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649709164544

    authors: Ohsawa S,Ueno R

    更新日期:1997-08-01 00:00:00

  • New walking aid for primary mobilization of an infant with deficiency of all four limbs.

    abstract::The authors report on a new device for the primary mobilization of a boy with severe deficiencies of all four limbs. This device allows independent mobility. ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164671

    authors: Balogh S,Gönczy T,Bujdosó R,Kullmann L

    更新日期:1994-04-01 00:00:00

  • Measuring foam model shapes with a contact digitizer.

    abstract:BACKGROUND AND AIM:It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE:A controlled laboratory study was c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364610394478

    authors: Sanders JE,Severance MR

    更新日期:2011-06-01 00:00:00

  • Weight bearing and velocity in trans-tibial and trans-femoral amputees.

    abstract::The purpose of this study was to review the clinical utility of static weight bearing (SWB) and maximal self-selected ambulatory velocity as objective quantifiable measures in an outpatient lower limb prosthetic clinic. Seventy-three (n = 73) consecutive trans-tibial (TTA) and trans-femoral amputees (TFA) attending an...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.3109/03093649709164553

    authors: Jones ME,Bashford GM,Mann JM

    更新日期:1997-12-01 00:00:00

  • Removable rigid dressings: a retrospective case-note audit to determine the validity of post-amputation application.

    abstract::This study investigated the validity of post-amputation application of removable rigid dressings (RRDs) for trans-tibial amputees, regarding preparation for prosthetic management and key rehabilitation timelines. It was hypothesised that the use of RRDs would result in faster preparation of the residual limb for prost...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802016795

    authors: Taylor L,Cavenett S,Stepien JM,Crotty M

    更新日期:2008-06-01 00:00:00

  • The social and economic outcome after upper limb amputation.

    abstract::This paper reports a study of 66 upper limb amputees in County Funen, Denmark who were visited in their homes by the author. The purpose of this study was to evaluate for the same period of time the social and economic outcome for a population of upper limb amputees compared with the normal population. The number of a...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649209164304

    authors: Kejlaa GH

    更新日期:1992-04-01 00:00:00

  • Integration of surface electromyographic sensors with the transfemoral amputee socket: a comparison of four differing configurations.

    abstract:BACKGROUND AND AIM:In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical int...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613516484

    authors: Hefferman GM,Zhang F,Nunnery MJ,Huang H

    更新日期:2015-04-01 00:00:00

  • Mandible reconstruction: History, state of the art and persistent problems.

    abstract:BACKGROUND:Mandibular reconstruction has been experiencing an amazing evolution. Several different approaches are used to reconstruct this bone and therefore have a fundamental role in the recovery of oral functions. OBJECTIVES:This review aims to highlight the persistent problems associated with the approaches identi...

    journal_title:Prosthetics and orthotics international

    pub_type: 历史文章,杂志文章,评审

    doi:10.1177/0309364613520032

    authors: Ferreira JJ,Zagalo CM,Oliveira ML,Correia AM,Reis AR

    更新日期:2015-06-01 00:00:00

  • A new approach for the pistoning measurement in transtibial prosthesis.

    abstract:BACKGROUND:Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning. STUDY DESIGN:Clinical trial. OBJECTIVES:To introduce and evaluate a new simple method for measuring the pistoning between the soft liner and...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1177/0309364611423130

    authors: Gholizadeh H,Abu Osman NA,Lúvíksdóttir Á,Eshraghi A,Kamyab M,Wan Abas WA

    更新日期:2011-12-01 00:00:00

  • The stump capping procedure to prevent or treat terminal osseous overgrowth.

    abstract::Terminal overgrowth in transverse deficiencies and in amputations, particularly of the humerus and tibia necessitate serial trimming procedures or re-amputation. Capping using an autogenous bone graft or a titanium and polyethylene endoprosthetic cap provides a satisfactory way of avoiding these re-amputations and all...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164641

    authors: Pfeil J,Marquardt E,Holtz T,Niethard FU,Schneider E,Carstens C

    更新日期:1991-08-01 00:00:00

  • A CAD analysis programme for prosthetics and orthotics.

    abstract::A CAD (computer aided design) analysis software package (CADVIEW) was designed for use with prosthetic and orthotic CAD CAM (computer aided design/computer aided manufacture) systems. Using the Microsoft Windows 3.1 environment, CADVIEW provides a series of anatomical shape viewing and analysis tools. These tools incl...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164393

    authors: Lemaire E

    更新日期:1994-08-01 00:00:00

  • Prosthetic rehabilitation of a patient with finger amputation using silicone material.

    abstract:AIM:Finger and partial finger amputations are commonly due to traumatic injuries; digit loss may also be attributed to congenital malformations and disease. Finger prostheses are difficult to fabricate as they demand both aesthetic and function. When dealing with these types of prostheses, the only method of gaining su...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614528203

    authors: Goyal A,Goel H

    更新日期:2015-08-01 00:00:00

  • Sensory feedback add-on for upper-limb prostheses.

    abstract:BACKGROUND AND AIM:Sensory feedback systems have been of great interest in upper-limb prosthetics. Despite tremendous research, there are no commercial modality-matched feedback systems. This article aims to introduce the first detachable and feedback add-on option that can be attached to in-use prostheses. TECHNIQUE:...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616677653

    authors: Fallahian N,Saeedi H,Mokhtarinia H,Tabatabai Ghomshe F

    更新日期:2017-06-01 00:00:00

  • CIR Casting System for making transtibial sockets.

    abstract::This paper describes a new casting system for transtibial socket fabrication. Like the earlier CIR Sand Casting System, the CIR Casting System is based on the 'dilatancy' principle that is similar to the packaging process for coffee beans by which loose beans become a solid mass when a vacuum is applied. The main diff...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802446703

    authors: Wu Y,Casanova HR,Reisinger KD,Smith WK,Childress DS

    更新日期:2009-03-01 00:00:00

  • Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets.

    abstract::This study served as a pilot to develop the methodology for a larger number of clinical trials. Ten trans-tibial amputees compared sockets made by conventional methods with sockets made using computer aided socket design (CASD). Prosthetists, paired for experience, fitted each subject with one prosthesis using each me...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648609164519

    authors: Holden JM,Fernie GR

    更新日期:1986-12-01 00:00:00

  • Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.

    abstract::Interface pressures and shear stresses at different sagittal plane angular alignment settings were measured on 3 trans-tibial amputee subjects ambulating with patellar-tendon-bearing total contact prostheses. Substantial socket-shank angular alignment modifications in the sagittal plane had minimal effect on stance ph...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649909071607

    authors: Sanders JE,Daly CH

    更新日期:1999-04-01 00:00:00

  • Residual limb fluid volume change and volume accommodation: Relationships to activity and self-report outcomes in people with trans-tibial amputation.

    abstract:BACKGROUND:Fluctuations in limb volume degrade prosthesis fit and require users to accommodate changes using management strategies, such as donning and doffing prosthetic socks. OBJECTIVES:To examine how activities and self-report outcomes relate to daily changes in residual limb fluid volume and volume accommodation....

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364617752983

    authors: Sanders JE,Youngblood RT,Hafner BJ,Ciol MA,Allyn KJ,Gardner D,Cagle JC,Redd CB,Dietrich CR

    更新日期:2018-08-01 00:00:00

  • Importance of neurological evaluation before reverse shoulder arthroplasty in patients with previous poliomyelitis.

    abstract::We present a case report of a patient, affected by post-polio syndrome and cuff tear arthropathy of his right shoulder, who underwent reverse shoulder arthroplasty. A previous radial deficiency was unmasked in the post-operative follow-up, with passive elbow bending when the forearm was put in an antigravitational pos...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802425459

    authors: Castoldi F,Lollino N,Caranzano F,Assom M

    更新日期:2009-06-01 00:00:00

  • Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test.

    abstract:BACKGROUND:The functional performance of currently available body-powered prostheses is unknown. OBJECTIVE:The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. STUDY DESIGN:Experimental trial. METHODS:A total of 21 ab...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614554030

    authors: Haverkate L,Smit G,Plettenburg DH

    更新日期:2016-02-01 00:00:00

  • Corrigendum.

    abstract::The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees by C Beatriz Samitier, Lluis Guirao, Maria Costea, Josep M Camós, and Eulogio Pleguezuelos. Prosthetics and Orthotics International 2016; 40: 83-88, DOI: 10.1177/0309364614546927. ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,已发布勘误

    doi:10.1177/0309364616648557

    authors:

    更新日期:2016-08-01 00:00:00

  • The effect of knee brace misalignment on the anterior cruciate ligament: An experimental study.

    abstract:BACKGROUND:Protective knee braces are used for rehabilitation or prevention. Due to poor patient compliance or slippage, the brace might be misaligned with the knee axis. OBJECTIVES:Does a misaligned knee brace stress the anterior cruciate ligament? STUDY DESIGN:It is an experimental study. METHODS:A strain sensor w...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618824443

    authors: Hacker SP,Schall F,Ignatius A,Dürselen L

    更新日期:2019-06-01 00:00:00

  • Standing balance in people with trans-tibial amputation due to vascular causes: A literature review.

    abstract:BACKGROUND:Balance is an important variable to consider during the rehabilitation process of individuals with trans-tibial amputation. Limited evidence exists on the balance abilities of people with trans-tibial amputation due to vascular causes. OBJECTIVE:The purpose of this article is to review literature and determ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364616683819

    authors: Seth M,Lamberg E

    更新日期:2017-08-01 00:00:00

  • A study of 200 cases of congenital limb deficiencies.

    abstract::An analysis of 200 patients with congenital limb deficiency who attended the Artificial Limb Centre, Pune from January 1984 to April 1990 is presented. This group is representative of the congenital limb deficient population of the country. The commonest deficiencies were transverse phalangeal total/partial deficiency...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164402

    authors: Jain SK

    更新日期:1994-12-01 00:00:00

  • Influence of gait training and prosthetic foot category on external work symmetry during unilateral transtibial amputee gait.

    abstract:BACKGROUND:Prosthetic foot prescription guidelines lack scientific evidence and are concurrent with an amputee's concurrent with an amputee's Medicare Functional Classification Level (K-Level) and categorization of prosthetic feet. OBJECTIVE:To evaluate the influence of gait training and four categories of prosthetic ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612473501

    authors: Agrawal V,Gailey R,O'Toole C,Gaunaurd I,Finnieston A

    更新日期:2013-10-01 00:00:00

  • Comparison of prosthetic costs and service between osseointegrated and conventional suspended transfemoral prostheses.

    abstract:BACKGROUND:Nowadays, a transfemoral amputation prosthesis can be fitted to the skeleton using an osseointegrated implant, that is, without a socket. Treated patients have reported improvements in quality of life. OBJECTIVES:To investigate differences in prosthetic costs and service of osseointegrated prostheses compar...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612454160

    authors: Haggstrom EE,Hansson E,Hagberg K

    更新日期:2013-04-01 00:00:00