Scientific validation of two commercial pressure sensor systems for prosthetic socket fit.

Abstract:

:The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's F-Socket Pressure Measurement System, have been commercially designed for in situ interface pressure measurement over the past decade. Their use is not common in prosthetic practice, perhaps due to questions of cost effectiveness and the difficulties of interpreting the data. Another concern is the use of sensors for pressure measurements in areas of high contour and complex geometries such as the stump. Before these systems can be used in a clinical setting, it is necessary to determine the reliability and accuracy of each system. In order to assess the clinical validity of the Rincoe SFS and F-Socket systems, a series of trials was conducted to evaluate different aspects of sensor performance, namely; accuracy, hysteresis, drift and the effect of curvature. The sensors were subjected to tests in flatbed and custom-designed pressure vessels. Overall results indicated an accuracy error for the Rincoe SFS system of 25% (flatbed) and 33% (mould), with a corresponding 15% (flatbed) and 23% (mould) error in hysteresis, and 7% (flatbed) and 11% (mould) drift errors. The F-Socket system demonstrated an 8% (flatbed) and 11% (mould) accuracy errors, 42% (flatbed) and 24% (mould) hysteresis errors, and 12% (flatbed) and 33% (mould) drift errors. These findings indicate favourable results for the F-Socket Pressure Measurement System compared to the Rincoe Socket Fitting System with respect to its accuracy errors only. Nevertheless, it is the authors' belief that these systems are adequate in indicating areas of high pressure at the stump socket interface for clinical purposes, but both systems should be used with caution.

journal_name

Prosthet Orthot Int

authors

Polliack AA,Sieh RC,Craig DD,Landsberger S,McNeil DR,Ayyappa E

doi

10.1080/03093640008726523

keywords:

subject

Has Abstract

pub_date

2000-04-01 00:00:00

pages

63-73

issue

1

eissn

0309-3646

issn

1746-1553

journal_volume

24

pub_type

杂志文章
  • Custom skiing and trekking adaptations for a trans-tibial and trans-radial quadrilateral amputee.

    abstract::A keen skier who is a trans-tibial and trans-radial quadrilateral amputee sought an improved adaptation for skiing from the Rehabilitation Engineering Service in Edinburgh. The unpredictable nature of the bending moments and loads that can be imposed on the prostheses during skiing raised concern about the suitability...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093640409167927

    authors: Farley R,Mitchell F,Griffiths M

    更新日期:2004-04-01 00:00:00

  • The use of a direct manufacturing prosthetic socket system in a rural community in South Africa: A pilot study and lessons for future research.

    abstract:BACKGROUND:Challenges exist with the provision of appropriate mobility assistive devices in rural areas. The use of the direct manufacturing prosthetic socket system is a possible solution to these challenges. OBJECTIVES:The objective of this study was to test and explore the clients' perspectives with the application...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616683982

    authors: Ennion L,Johannesson A,Rhoda A

    更新日期:2017-10-01 00:00:00

  • Multi-segment kinematic model to assess three-dimensional movement of the spine and back during gait.

    abstract:BACKGROUND:Relatively little is known about spine during gait compared to movement analysis of the lower extremities. The trunk is often regarded and analysed as a single rigid segment and there is a paucity of information on inter-segmental movement within the spine and its relationship to pelvis and lower limbs. OBJ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364615579319

    authors: Needham R,Naemi R,Healy A,Chockalingam N

    更新日期:2016-10-01 00:00:00

  • New walking aid for primary mobilization of an infant with deficiency of all four limbs.

    abstract::The authors report on a new device for the primary mobilization of a boy with severe deficiencies of all four limbs. This device allows independent mobility. ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164671

    authors: Balogh S,Gönczy T,Bujdosó R,Kullmann L

    更新日期:1994-04-01 00:00:00

  • Prosthetic rehabilitation of a patient with finger amputation using silicone material.

    abstract:AIM:Finger and partial finger amputations are commonly due to traumatic injuries; digit loss may also be attributed to congenital malformations and disease. Finger prostheses are difficult to fabricate as they demand both aesthetic and function. When dealing with these types of prostheses, the only method of gaining su...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614528203

    authors: Goyal A,Goel H

    更新日期:2015-08-01 00:00:00

  • The stump capping procedure to prevent or treat terminal osseous overgrowth.

    abstract::Terminal overgrowth in transverse deficiencies and in amputations, particularly of the humerus and tibia necessitate serial trimming procedures or re-amputation. Capping using an autogenous bone graft or a titanium and polyethylene endoprosthetic cap provides a satisfactory way of avoiding these re-amputations and all...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164641

    authors: Pfeil J,Marquardt E,Holtz T,Niethard FU,Schneider E,Carstens C

    更新日期:1991-08-01 00:00:00

  • Pedorthic management of the diabetic foot.

    abstract:BACKGROUND:Conservative pedorthic management of the diabetic foot has been shown to be an effective method to prevent ulcers, amputations, and re-amputations. This article exhibits why and how pedorthics plays such an important role via modalities such as footwear, shoe modifications, custom foot orthoses, and partial ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364614535233

    authors: Janisse D,Janisse E

    更新日期:2015-02-01 00:00:00

  • Melorheostosis--an unusual cause of amputation.

    abstract::A 24-year-old female developed, in infancy, progressive right upper and lower limb muscle and soft tissue contractures and had a diagnosis of melorheostosis made on X-ray and pathological specimens. At the age of 11 years she began to have pain in the right hip and lower limb and this later became the dominant feature...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/17461550500066808

    authors: Graham LE,Parke RC

    更新日期:2005-04-01 00:00:00

  • A reference shape library for computer aided socket design in above-knee prostheses.

    abstract::A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is bas...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648909079421

    authors: Torres-Moreno R,Foort J,Morrison JB,Saunders CG

    更新日期:1989-12-01 00:00:00

  • Mathematical modelling and field trials of an inexpensive endoskeletal above-knee prosthesis.

    abstract::The swing-phase motion of the shank of an above-knee prosthesis has been modelled mathematically. An inexpensive endoskeletal prosthesis was designed using the Jaipur foot and conduit pipes with a hinge joint for the knee. Results of field trials and the modelling indicate that a very simple above-knee prosthesis can ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649209164323

    authors: Mohan D,Sethi PK,Ravi R

    更新日期:1992-08-01 00:00:00

  • New concept of spinal orthosis for weakened back muscles.

    abstract::An anterior bending posture of the trunk during walking is often seen among the elderly commonly due to weakened thoraco-lumbar and gluteal muscles. For the management of this debilitating condition, the authors have developed a modified design of thoraco-lumbosacral orthosis (TLSO). Incorporated in this device are po...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649509078233

    authors: Watanabe H,Kutsuna T,Asami T,Inoue E

    更新日期:1995-04-01 00:00:00

  • Clinical field testing of vulcanized rubber feet for trans-tibial amputees in tropical low-income countries.

    abstract::In a prospective, controlled study, 186 prosthetic rubber feet of different designs were fitted to amputees with trans-tibial prostheses. There were 158 amputees available for follow-up. The amputee compliance was good and 89% were satisfied with their device. After 18 months of use one VI-Solid rubber foot from VVAF ...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1080/03093640600794692

    authors: Steen Jensen J,Nilsen R,Zeffer J,Fisk J,Hartz C

    更新日期:2006-08-01 00:00:00

  • Comparison of prosthetic outcomes between adolescent transtibial and transfemoral amputees after Sichuan earthquake using Step Activity Monitor and Prosthesis Evaluation Questionnaire.

    abstract:BACKGROUND:The devastating earthquake in Sichuan in 2008 has left many adolescent amputees. However, little research has been focused on the adolescent amputees who have high potential to return to premorbid activity level. OBJECTIVES:To investigate daily step activities and prosthesis-related quality of life of the a...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614556837

    authors: Chu CK,Wong MS

    更新日期:2016-02-01 00:00:00

  • Significance of recumbent curvature in prediction of in-orthosis correction for adolescent idiopathic scoliosis.

    abstract:BACKGROUND::Prediction of in-orthosis curvature at pre-orthosis stage is valuable for the treatment planning for adolescent idiopathic scoliosis, while the position of spinal curvature assessment that is effective for this prediction is still unknown. OBJECTIVES::To compare the spinal curvatures in different body posi...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618798172

    authors: He C,To MK,Chan CK,Wong MS

    更新日期:2019-04-01 00:00:00

  • The use of flexible polyurethane foam in orthotics.

    abstract::The casting of flexible polyurethane foam into a wide range of customised shapes has been found to offer a relatively straightforward solution to a number of problems associated with providing support for the physically handicapped. This note describes the techniques used for the production of such supports and report...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648409145359

    authors: Taylor AG

    更新日期:1984-08-01 00:00:00

  • The care of the limb deficient child in north Africa.

    abstract::The surgical and prosthetic treatment of longitudinal lower limb deficiency is described and discussed, in the light of cultural and social requirements. Those with upper limb deficiencies are not fitted with prostheses. ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164653

    authors: Sliman N,Mrabet A,Daghfous S,Douik M

    更新日期:1991-08-01 00:00:00

  • Effects of heel lifting on transtibial amputee gait before and after treadmill walking: a case study.

    abstract:BACKGROUND:Prosthetic alignment is usually unchanged once optimized. However, a previous study indicated that long-distance walking significantly altered gait patterns, suggesting some alignment adjustments after walking are required. This study investigated the effects of alignment changes (by inserting a heel lift) o...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612461521

    authors: Yeung LF,Leung AK,Zhang M,Lee WC

    更新日期:2013-08-01 00:00:00

  • Biomechanical improvements following foot strike biofeedback training for a patient using a passive dynamic ankle-foot orthosis during running.

    abstract:BACKGROUND AND PURPOSE:Passive dynamic ankle-foot orthoses have potential to facilitate return to running after a lower limb trauma. However, transitioning patients to new movement patterns that enhance passive dynamic ankle-foot orthoses benefits can pose a challenge. The purpose of this case study was to report biome...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364619851935

    authors: Yoder AJ,Mazzone BN,Miltenberger RS,Farrokhi S

    更新日期:2019-08-01 00:00:00

  • Powered prosthetic hands in very young children.

    abstract::Myoelectric prostheses are generally not provided in the United Kingdom for children before the age of 3 1/2 years. Following the introduction of a smaller sized electric hand in the United Kingdom in 1993 the authors decided to introduce electrically powered hands for a group of congenital upper limb deficient childr...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649809164477

    authors: Datta D,Ibbotson V

    更新日期:1998-08-01 00:00:00

  • Continuous passive motion in hand rehabilitation.

    abstract::This paper reviews the literature comparing the results obtained in applying regimes involving motion with those involving rest following injury or surgery. The deleterious effects of immobilisation are compared to those obtained under conditions of passive motion and intermittent passive motion. It is concluded that ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.3109/03093649309164369

    authors: Dent JA

    更新日期:1993-08-01 00:00:00

  • Orthoses to fit shoes.

    abstract::Orthoses which fit inside shoes have, in many cases in the past, been fashioned to the shape of the patient's foot. It is suggested that improved stability and comfort is achieved if, instead, the outside shape of the foot-piece of the orthosis is fashioned to the inside shape of the footwear. A method for achieving t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647909103088

    authors: Platts RG,Field A,Knight S

    更新日期:1979-08-01 00:00:00

  • Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test.

    abstract:BACKGROUND:The functional performance of currently available body-powered prostheses is unknown. OBJECTIVE:The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. STUDY DESIGN:Experimental trial. METHODS:A total of 21 ab...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614554030

    authors: Haverkate L,Smit G,Plettenburg DH

    更新日期:2016-02-01 00:00:00

  • Heel lifting as a conservative therapy for osteoarthritis of the hip: based on the rationale of Pauwels' intertrochanteric osteotomy.

    abstract::Patients with osteoarthritis of the hip were treated with a conservative therapy of heel lifting. Orthoses were applied on 35 hips in 33 subjects and the cases were followed for 23 months on average. Dramatic pain relief was reported, but the time required to reduce or completely relieve pain increased according to th...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649709164544

    authors: Ohsawa S,Ueno R

    更新日期:1997-08-01 00:00:00

  • Analysis of the swing phase dynamics and muscular effort of the above-knee amputee for varying prosthetic shank loads.

    abstract::The purpose of this study was to determine the effect of varying prosthetic shank mass, while maintaining the mass centre location and moment of inertia, on the swing phase kinematics, kinetics and hip muscular effort of free speed above-knee (AK) amputee gait. Six AK amputees, wearing similar prosthetic designs, had ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649009080338

    authors: Hale SA

    更新日期:1990-12-01 00:00:00

  • HRC adjustable pneumatic swing-phase control knee.

    abstract::Since 1972 the Hyogo Rehabilitation Centre has been developing a variable-resistance-type pneumatic control device, the HRC Adjustable Pneumatic Swing-Phase Control Knee. Successful field tests have been carried out on 20 cases with Model IV since 1973 with only a limited number of mechanical troubles. This paper intr...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647809166698

    authors: Nakamura S,Sawamura S

    更新日期:1978-12-01 00:00:00

  • Toileting self-care methods for bilateral high level upper limb amputees.

    abstract::One of the most important problems for the bilateral upper limb deficient patient is the inability to manage toileting activities. Dependence in this area precludes schooling or work. This paper surveys available clothing types and adaptations to facilitate doffing and donning clothing and devices for genital cleansin...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648009103112

    authors: Friedmann L

    更新日期:1980-04-01 00:00:00

  • The treatment of longitudinal ulnar deficiency.

    abstract::Longitudinal ulnar deficiency, whose detailed anatomy is varied, is often accompanied by other abnormalities and appears as part of several syndromes. The history of its classification is reviewed, and the treatments, which have been offered, described. Follow-up of a series shows that the function achieved is good an...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164643

    authors: Lovett RJ

    更新日期:1991-08-01 00:00:00

  • The Prosthetist Role Expectations Scale: Development and initial validation of a scale for clinical settings.

    abstract:BACKGROUND:The role of the prosthetist has changed substantially over the past century. In the transition from 'limb-maker' to 'clinician', the expectations of prosthetics professionals have also changed. OBJECTIVES:To develop and test a new scale capable of assessing and comparing current expectations of the roles of...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364617698519

    authors: Mackenzie RL,Morris ME,Murphy G,Hodge MC

    更新日期:2018-04-01 00:00:00

  • Tolerance of early walking with total contact among below-knee amputees--a randomized test.

    abstract::In order to reduce the need for repeated changes of socket due to postoperative atrophy and resorption of oedema simple temporary limbs are required to delay the casting of individual sockets until the stump is more mature. A randomized study of 95 below-knee amputees was performed with a re-usable temporary one-size ...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.3109/03093648309166980

    authors: Liedberg E,Hommerberg H,Persson BM

    更新日期:1983-08-01 00:00:00

  • Measuring foam model shapes with a contact digitizer.

    abstract:BACKGROUND AND AIM:It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE:A controlled laboratory study was c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364610394478

    authors: Sanders JE,Severance MR

    更新日期:2011-06-01 00:00:00