The treatment of longitudinal ulnar deficiency.

Abstract:

:Longitudinal ulnar deficiency, whose detailed anatomy is varied, is often accompanied by other abnormalities and appears as part of several syndromes. The history of its classification is reviewed, and the treatments, which have been offered, described. Follow-up of a series shows that the function achieved is good and is optimised by aids, occupational therapy and some hand surgical procedures. The more elaborate surgical reconstructions are unlikely to be beneficial.

journal_name

Prosthet Orthot Int

authors

Lovett RJ

doi

10.3109/03093649109164643

subject

Has Abstract

pub_date

1991-08-01 00:00:00

pages

104-5

issue

2

eissn

0309-3646

issn

1746-1553

journal_volume

15

pub_type

杂志文章
  • Nordic clinical guidelines for orthotic treatment of osteoarthritis of the knee: A systematic review using the AGREE II instrument.

    abstract:BACKGROUND:High-quality clinical practice guidelines are necessary for effective use of resources both at an individual patient- and national-level. Nordic clinical practice guidelines recommendations for orthotic treatment of knee osteoarthritis vary and little is known about their quality. OBJECTIVES:The aim of the ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364619857854

    authors: Jarl G,Hellstrand Tang U,Nordén E,Johannesson A,Rusaw DF

    更新日期:2019-10-01 00:00:00

  • The mobile arm support.

    abstract::The Mobile Arm Support, conceived and researched by Dr. Radulovic, is intended for the use of patients whose arm is afflicted. The support consists of a supporting harness, an articulated splint on which the arm is fixed and a pneumatic system of elevation that counterbalances the weight of the arm. Its originality li...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648009164573

    authors: Radulovic R,Piera JB,Cassagne B,Grossiord A,Boruchowitsch G

    更新日期:1980-08-01 00:00:00

  • The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm.

    abstract:BACKGROUND AND AIM:DEKA Integrated Solutions Corp. (DEKA) was charged by the Defense Advanced Research Project Agency to design a prosthetic arm system that would be a dramatic improvement compared with the existing state of the art. The purpose of this article is to describe the two DEKA Arm prototypes (Gen 2 and Gen ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613506913

    authors: Resnik L,Klinger SL,Etter K

    更新日期:2014-12-01 00:00:00

  • Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test.

    abstract:BACKGROUND:The functional performance of currently available body-powered prostheses is unknown. OBJECTIVE:The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. STUDY DESIGN:Experimental trial. METHODS:A total of 21 ab...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614554030

    authors: Haverkate L,Smit G,Plettenburg DH

    更新日期:2016-02-01 00:00:00

  • Influence of gait training and prosthetic foot category on external work symmetry during unilateral transtibial amputee gait.

    abstract:BACKGROUND:Prosthetic foot prescription guidelines lack scientific evidence and are concurrent with an amputee's concurrent with an amputee's Medicare Functional Classification Level (K-Level) and categorization of prosthetic feet. OBJECTIVE:To evaluate the influence of gait training and four categories of prosthetic ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612473501

    authors: Agrawal V,Gailey R,O'Toole C,Gaunaurd I,Finnieston A

    更新日期:2013-10-01 00:00:00

  • Comparison of gait between healthy participants and persons with spinal cord injury when using the advanced reciprocating gait orthosis.

    abstract:BACKGROUND:The advanced reciprocating gait orthosis (ARGO) has a rigid structure which provides restricted movement at the hip, knee, and ankle joints and incorporates a pelvic section with an extended section in the lumbar region. Healthy subjects, when walking with an RGO in situ, could feasibly demonstrate the level...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364615592699

    authors: Arazpour M,Joghtaei M,Bahramizadeh M,Ahmadi Bani M,Hutchins SW,Curran S,Mousavi ME,Sharifi G,Mardani MA

    更新日期:2016-04-01 00:00:00

  • Quality of life of persons with transfemoral amputation: Comparison of socket prostheses and osseointegrated prostheses.

    abstract:BACKGROUND:Until recently, no study had compared the quality of life of persons with transfemoral amputation treated with osseointegration to socket prosthesis users. OBJECTIVES:Comparison of quality of life in two types of prostheses users: a cohort of patients with osseointegration and patients equipped with a socke...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620948649

    authors: Pospiech PT,Wendlandt R,Aschoff HH,Ziegert S,Schulz AP

    更新日期:2020-08-25 00:00:00

  • Weight bearing and velocity in trans-tibial and trans-femoral amputees.

    abstract::The purpose of this study was to review the clinical utility of static weight bearing (SWB) and maximal self-selected ambulatory velocity as objective quantifiable measures in an outpatient lower limb prosthetic clinic. Seventy-three (n = 73) consecutive trans-tibial (TTA) and trans-femoral amputees (TFA) attending an...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.3109/03093649709164553

    authors: Jones ME,Bashford GM,Mann JM

    更新日期:1997-12-01 00:00:00

  • A series of case studies on the effect of a midfoot control ankle foot orthosis in the prevention of unresolved pressure areas in children with cerebral palsy.

    abstract::This paper reports on a series of case studies where improvements were sought in muscle tone and gait in children with cerebral palsy. A Midfoot Control Ankle Foot Orthosis (AFO) was developed to control foot position in a cohort of patients with cerebral palsy (CP). The concept of controlling midfoot and hindfoot wit...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1080/03093640108726609

    authors: Bill M,McIntosh R,Myers P

    更新日期:2001-12-01 00:00:00

  • Failures in through-knee amputation.

    abstract::Long-term results over a period of more than 10 years give evidence of the superiority of the through-knee compared to the above-knee stump. However, failures in through-knee stumps before, during and after operation and pitfalls in prosthetic fitting are still too frequent. They are mostly due to errors because the p...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648309166986

    authors: Baumgartner R

    更新日期:1983-08-01 00:00:00

  • The impact of gender, level of amputation and diabetes on prosthetic fit rates following major lower extremity amputation.

    abstract:BACKGROUND:Diabetes mellitus is a leading cause of major lower extremity amputation. OBJECTIVE:To examine the influence of gender, level of amputation and diabetes mellitus status on being fit with a prosthetic limb following lower extremity amputation for peripheral arterial disease. STUDY DESIGN:Retrospective analy...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616628341

    authors: Davie-Smith F,Paul L,Nicholls N,Stuart WP,Kennon B

    更新日期:2017-02-01 00:00:00

  • The effect of floor reaction ankle foot orthosis on postural control in children with spastic cerebral palsy.

    abstract:BACKGROUND:Children with cerebral palsy (CP) often demonstrate postural control difficulties. Orthotic management may assist in improving postural control in these children. OBJECTIVE:The purpose of this investigation was to examine the influence of floor reaction ankle foot orthosis (FRAFO) on postural flexion called...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364611429855

    authors: Bahramizadeh M,Mousavi ME,Rassafiani M,Aminian G,Ebrahimi I,Karimlou M,Toole GO

    更新日期:2012-03-01 00:00:00

  • Scientific validation of two commercial pressure sensor systems for prosthetic socket fit.

    abstract::The concept of measuring pressure at the interface between the stump and the prosthetic socket could provide valuable information in the process of prosthetic socket fabrication, modification, and fit. Two systems, the Rincoe Socket Fitting System (SFS) and Tekscan's F-Socket Pressure Measurement System, have been com...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640008726523

    authors: Polliack AA,Sieh RC,Craig DD,Landsberger S,McNeil DR,Ayyappa E

    更新日期:2000-04-01 00:00:00

  • A novel technique for fabricating an ear prosthesis in a patient with congenital ear deformity.

    abstract:BACKGROUND AND AIM:Microtia is one of the forms of ear loss and deformity. A prosthesis that is simple to apply, and which has adequate suspension and acceptable aesthetics, can be useful in the rehabilitation of patients with this deficit and can improve the social and psychological effects of patients with ear amputa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612467344

    authors: Mardani MA,Aminian G,Tabatabaian F,Arazpour M,Hutchins SW,Head JS

    更新日期:2013-08-01 00:00:00

  • Passive prosthetic hands and tools: A literature review.

    abstract:BACKGROUND:The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no re...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364617691622

    authors: Maat B,Smit G,Plettenburg D,Breedveld P

    更新日期:2018-02-01 00:00:00

  • A reference shape library for computer aided socket design in above-knee prostheses.

    abstract::A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is bas...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648909079421

    authors: Torres-Moreno R,Foort J,Morrison JB,Saunders CG

    更新日期:1989-12-01 00:00:00

  • Outcomes of knee disarticulation and the influence of surgical techniques in dysvascular patients: A systematic review.

    abstract:BACKGROUND:Dysvascularity is the main cause of lower limb amputations in Scotland, and there is an insignificant proportion (1.7%) of knee disarticulations, despite the benefits of amputation. OBJECTIVES:The outcomes of knee disarticulation and its associated surgical techniques will be evaluated based on healing, rea...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364615574163

    authors: Murakami T,Murray K

    更新日期:2016-08-01 00:00:00

  • Comparison of prosthetic costs and service between osseointegrated and conventional suspended transfemoral prostheses.

    abstract:BACKGROUND:Nowadays, a transfemoral amputation prosthesis can be fitted to the skeleton using an osseointegrated implant, that is, without a socket. Treated patients have reported improvements in quality of life. OBJECTIVES:To investigate differences in prosthetic costs and service of osseointegrated prostheses compar...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612454160

    authors: Haggstrom EE,Hansson E,Hagberg K

    更新日期:2013-04-01 00:00:00

  • Long term comparison of some shock attenuating insoles.

    abstract::The effect of one years general use on the performance of four shock attenuating insoles is reported. Testing was carried out using the JP Biomechanics Shock Meter on twelve volunteers on a timed oval course at eight intervals during the year. The results show that two of the insoles perform well (Viscolas and PPT) al...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649009080322

    authors: Pratt DJ

    更新日期:1990-08-01 00:00:00

  • Effect of custom-made and prefabricated orthoses on grip strength in persons with carpal tunnel syndrome.

    abstract:BACKGROUND:Based on the literature, patients with carpal tunnel syndrome are suggested to wear a custom-made wrist orthosis immobilizing the wrist in a neutral position. Many prefabricated orthoses are available on the market, but the majority of those do not assure neutral wrist position. OBJECTIVES:We hypothesized t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613490440

    authors: Mlakar M,Ramstrand N,Burger H,Vidmar G

    更新日期:2014-06-01 00:00:00

  • Significance of recumbent curvature in prediction of in-orthosis correction for adolescent idiopathic scoliosis.

    abstract:BACKGROUND::Prediction of in-orthosis curvature at pre-orthosis stage is valuable for the treatment planning for adolescent idiopathic scoliosis, while the position of spinal curvature assessment that is effective for this prediction is still unknown. OBJECTIVES::To compare the spinal curvatures in different body posi...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618798172

    authors: He C,To MK,Chan CK,Wong MS

    更新日期:2019-04-01 00:00:00

  • Sensory feedback add-on for upper-limb prostheses.

    abstract:BACKGROUND AND AIM:Sensory feedback systems have been of great interest in upper-limb prosthetics. Despite tremendous research, there are no commercial modality-matched feedback systems. This article aims to introduce the first detachable and feedback add-on option that can be attached to in-use prostheses. TECHNIQUE:...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616677653

    authors: Fallahian N,Saeedi H,Mokhtarinia H,Tabatabai Ghomshe F

    更新日期:2017-06-01 00:00:00

  • The importance of being earnest about shank and thigh kinematics especially when using ankle-foot orthoses.

    abstract::This paper reviews and summarizes the evidence for important observations of normal and pathological gait and presents an approach to rehabilitation and orthotic management, which is based on the significance of shank and thigh kinematics for standing and gait. It discusses normal gait biomechanics, challenging some t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.3109/03093646.2010.485597

    authors: Owen E

    更新日期:2010-09-01 00:00:00

  • Affordable passive 3D-printed prosthesis for persons with partial hand amputation.

    abstract:BACKGROUND AND AIM:Partial hand amputations are common in developing countries and have a negative impact on patients and their families' quality of life. The uniqueness of each partial hand amputation, coupled with the relatively high costs of prostheses, makes it challenging to provide suitable prosthetic solutions i...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620905220

    authors: Alturkistani R,A K,Devasahayam S,Thomas R,Colombini EL,Cifuentes CA,Homer-Vanniasinkam S,Wurdemann HA,Moazen M

    更新日期:2020-04-01 00:00:00

  • Selection of an above or below-ankle orthosis for individuals with neuropathic partial foot amputation: a pilot study.

    abstract:BACKGROUND:Little evidence exists for the orthotic management for individuals diagnosed with diabetic neuropathy and partial foot amputation. OBJECTIVE:This pilot study examined differences in balance and pressure distribution while individuals wore foot orthoses inside shoes (BA) and this same orthosis combined with ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612437005

    authors: Spaulding SE,Chen T,Chou LS

    更新日期:2012-06-01 00:00:00

  • Development and measurement properties of the Orthotics and Prosthetics Users' Survey (OPUS): a comprehensive set of clinical outcome instruments.

    abstract::The need to measure and evaluate orthotics and prosthetics (O&P) practice has received growing recognition in the past several years. Reliable and valid self-report instruments are needed that can help facilities evaluate patient outcomes. The objective of this project was to develop a set of self-report instruments t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640308726682

    authors: Heinemann AW,Bode RK,O'Reilly C

    更新日期:2003-12-01 00:00:00

  • A new directly moulded patellar-tendon-bearing socket.

    abstract::Silicone rubbers and casting tapes individually have previously been used in the manufacture of sockets (Swanson, 1972; Sweitzer, 1973; Ruder, 1977; Graves, 1980; Aqualite, 1982). The authors believe that the present combination of these materials to manufacture a directly moulded socket with a complete silicone rubbe...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648509164717

    authors: Boot DA,Young NJ

    更新日期:1985-08-01 00:00:00

  • Development and characterisation of electromechanical muscles for driving trans-humeral myoelectric prostheses.

    abstract::Recently, attempts have been made to construct actuators with similar behaviour to natural muscles. However the results have been inadequate for application to practical prostheses. For example, muscle wire, which has too low an efficiency to be powered by batteries and McKibben muscles which require two power supplie...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640208726652

    authors: Escudero AZ,Alvarez J,Leija L

    更新日期:2002-12-01 00:00:00

  • Upper limb prosthesis use and abandonment: a survey of the last 25 years.

    abstract::This review presents an analytical and comparative survey of upper limb prosthesis acceptance and abandonment as documented over the past 25 years, detailing areas of consumer dissatisfaction and ongoing technological advancements. English-language articles were identified in a search of Ovid, PubMed, and ISI Web of S...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1080/03093640600994581

    authors: Biddiss EA,Chau TT

    更新日期:2007-09-01 00:00:00

  • Knee disarticulation versus above-knee amputation.

    abstract::If below-knee amputation is impossible, knee disarticulation should be considered before above-knee amputation, regardless of age and etiology. Knee disarticulation which leaves the femur and patella untoched offers many advantages. The surgical technique is simple and non-traumatic since no bone or muscle tissue is t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647909164695

    authors: Baumgartner RF

    更新日期:1979-04-01 00:00:00