Measuring foam model shapes with a contact digitizer.

Abstract:

BACKGROUND AND AIM:It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE:A controlled laboratory study was conducted. Thirty trans-tibial socket models were measured using a custom mechanical digitizer. Models were coated with a thin layer of resin, and then the resin thickness measured and subtracted from the digitizer data. Error introduced to the measurement from presence of the resin was determined. RESULTS AND DISCUSSION:The technique did not introduce meaningful error to the digitizer data beyond that already present from other sources in the instrument. The total instrument error for the contact digitizer used was 0.1% for model volume and 0.05 mm for mean radii. The root-mean-square error for individual measurement points was 0.08 mm. While resin coating introduced error to the digitizer measurements, the effect on volume, mean radii and interquartile range accuracies was minimal. CLINICAL RELEVANCE:Accurate model measurements can assist clinical service providers in the identification of problems and the repair of carving equipment. This facilitates the delivery of high quality sockets to practitioners and patients.

journal_name

Prosthet Orthot Int

authors

Sanders JE,Severance MR

doi

10.1177/0309364610394478

subject

Has Abstract

pub_date

2011-06-01 00:00:00

pages

242-5

issue

2

eissn

0309-3646

issn

1746-1553

pii

0309364610394478

journal_volume

35

pub_type

杂志文章
  • The effect of custom carbon ankle-foot orthosis alignment on roll-over shape and center of pressure velocity.

    abstract:BACKGROUND:Maintaining an optimal rolling of the foot over the ground is thought to increase the stability and efficiency of pathologic gait. Ankle-foot orthoses are often prescribed to improve gait mechanics in individuals with lower extremity injuries; however, their design may compromise how the foot rolls over the ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620971407

    authors: Russell Esposito E,Ruble MD,Ikeda AJ,Wilken JM

    更新日期:2020-11-21 00:00:00

  • A new approach for the pistoning measurement in transtibial prosthesis.

    abstract:BACKGROUND:Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning. STUDY DESIGN:Clinical trial. OBJECTIVES:To introduce and evaluate a new simple method for measuring the pistoning between the soft liner and...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1177/0309364611423130

    authors: Gholizadeh H,Abu Osman NA,Lúvíksdóttir Á,Eshraghi A,Kamyab M,Wan Abas WA

    更新日期:2011-12-01 00:00:00

  • An adjustable shoulder abduction orthosis for the post-operative management of tendon transfers: A preliminary study.

    abstract::Transfer of Musculus Latissimus dorsi/M. Teres major to the rotator cuff with or without M. Subscapularis/M. Pectoralis release is a widely used procedure for restoring shoulder abduction and external rotation in squeal of obstetric brachial plexus palsy. After the operation a shoulder abduction orthosis in maximal ex...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802015755

    authors: Erel S,Simşek IE,Ayhan C,Bek N,Yakut Y,Uygur F

    更新日期:2008-06-01 00:00:00

  • Integration of surface electromyographic sensors with the transfemoral amputee socket: a comparison of four differing configurations.

    abstract:BACKGROUND AND AIM:In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical int...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613516484

    authors: Hefferman GM,Zhang F,Nunnery MJ,Huang H

    更新日期:2015-04-01 00:00:00

  • Toileting self-care methods for bilateral high level upper limb amputees.

    abstract::One of the most important problems for the bilateral upper limb deficient patient is the inability to manage toileting activities. Dependence in this area precludes schooling or work. This paper surveys available clothing types and adaptations to facilitate doffing and donning clothing and devices for genital cleansin...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648009103112

    authors: Friedmann L

    更新日期:1980-04-01 00:00:00

  • Step count accuracy of StepWatch and FitBit One™ among individuals with a unilateral transtibial amputation.

    abstract:BACKGROUND:Step counts, obtained via activity monitors, provide insight into activity level in the free-living environment. Accuracy assessments of activity monitors are limited among individuals with lower-limb amputations. OBJECTIVES:(1) To evaluate the step count accuracy of both monitors during forward-linear and ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618767138

    authors: Arch ES,Sions JM,Horne J,Bodt BA

    更新日期:2018-10-01 00:00:00

  • Long term comparison of some shock attenuating insoles.

    abstract::The effect of one years general use on the performance of four shock attenuating insoles is reported. Testing was carried out using the JP Biomechanics Shock Meter on twelve volunteers on a timed oval course at eight intervals during the year. The results show that two of the insoles perform well (Viscolas and PPT) al...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649009080322

    authors: Pratt DJ

    更新日期:1990-08-01 00:00:00

  • A field evaluation of arm prostheses for unilateral amputees.

    abstract::A post-clinical investigation has been carried out among 42 unilateral amputees who lost their hand due to an accident. The investigation was directed at two main topics of interest. Firstly the amputee, the problems he has to cope with, and the role the prosthesis plays in his life; and secondly the prosthesis, its u...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648309166586

    authors: van Lunteren A,van Lunteren-Gerritsen GH,Stassen HG,Zuithoff MJ

    更新日期:1983-12-01 00:00:00

  • Evaluation of a novel powered hip orthosis for walking by a spinal cord injury patient: a single case study.

    abstract:BACKGROUND:The aim of this case study was to identify the effect of a powered hip orthosis on the kinematics and temporal-spatial parameters of walking by a patient with spinal cord injury (SCI). CASE DESCRIPTION AND METHODS:Two orthoses were evaluated while worn by an incomplete SCI subject with a T-8level of injury....

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364611431482

    authors: Arazpour M,Chitsazan A,Hutchins SW,Ghomshe FT,Mousavi ME,Takamjani EE,Aminian G,Rahgozar M,Bani MA

    更新日期:2012-03-01 00:00:00

  • Load on osseointegrated fixation of a transfemoral amputee during a fall: loading, descent, impact and recovery analysis.

    abstract::Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterize a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093640903585024

    authors: Frossard LA,Tranberg R,Haggstrom E,Pearcy M,Brånemark R

    更新日期:2010-03-01 00:00:00

  • Using NetMeeting for remote configuration of the Otto Bock C-Leg: technical considerations.

    abstract::Telehealth has the potential to be a valuable tool for technical and clinical support of computer controlled prosthetic devices. This pilot study examined the use of Internet-based, desktop video conferencing for remote configuration of the Otto Bock C-Leg. Laboratory tests involved connecting two computers running Mi...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640208726638

    authors: Lemaire ED,Fawcett JA

    更新日期:2002-08-01 00:00:00

  • The Prosthetist Role Expectations Scale: Development and initial validation of a scale for clinical settings.

    abstract:BACKGROUND:The role of the prosthetist has changed substantially over the past century. In the transition from 'limb-maker' to 'clinician', the expectations of prosthetics professionals have also changed. OBJECTIVES:To develop and test a new scale capable of assessing and comparing current expectations of the roles of...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364617698519

    authors: Mackenzie RL,Morris ME,Murphy G,Hodge MC

    更新日期:2018-04-01 00:00:00

  • Evaluation of the psychophysical detection threshold level for vibrotactile and pressure stimulation of prosthetic limbs using bone anchorage or soft tissue support.

    abstract::In the present study the psychophysical detection threshold levels mechanical stimulation of 32 prosthetic limbs were determined. Prosthetic limbs were anchored to the bone by means of an implant (n=17) or supported by a socket enclosing the amputation stump (n=15). Detection threshold levels were assessed for pressur...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1080/03093640008726536

    authors: Jacobs R,Brånemark R,Olmarker K,Rydevik B,Van Steenberghe D,Brånemark PI

    更新日期:2000-08-01 00:00:00

  • Comparison of the efficacy of laterally wedged insoles and bespoke unloader knee orthoses in treating medial compartment knee osteoarthritis.

    abstract:BACKGROUND:Patients suffering from medial compartment knee osteoarthritis (OA) may be treated with unloader knee orthoses or laterally wedged insoles. OBJECTIVES:The aim of this study was to identify and compare the effects of them on the gait parameters and pain in these patients. STUDY DESIGN:Quasi-experimental. M...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612447094

    authors: Arazpour M,Bani MA,Maleki M,Ghomshe FT,Kashani RV,Hutchins SW

    更新日期:2013-02-01 00:00:00

  • A model to facilitate implementation of the International Classification of Functioning, Disability and Health into prosthetics and orthotics.

    abstract:BACKGROUND:The International Classification of Functioning, Disability and Health is a classification of human functioning and disability and is based on a biopsychosocial model of health. As such, International Classification of Functioning, Disability and Health seems suitable as a basis for constructing models defin...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364617729925

    authors: Jarl G,Ramstrand N

    更新日期:2018-10-01 00:00:00

  • Development and measurement properties of the Orthotics and Prosthetics Users' Survey (OPUS): a comprehensive set of clinical outcome instruments.

    abstract::The need to measure and evaluate orthotics and prosthetics (O&P) practice has received growing recognition in the past several years. Reliable and valid self-report instruments are needed that can help facilities evaluate patient outcomes. The objective of this project was to develop a set of self-report instruments t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640308726682

    authors: Heinemann AW,Bode RK,O'Reilly C

    更新日期:2003-12-01 00:00:00

  • The i-LIMB hand and the DMC plus hand compared: a case report.

    abstract::The i-LIMB hand is a novel upper limb myoelectric prosthetic hand with several joints in the fingers and thumb. This study aimed to determine whether this new device had more functionality than a more conventional myoelectric prosthetic hand with only a single joint between the thumb and two fingers. Therefore, a 45-y...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093641003767207

    authors: Otr OV,Reinders-Messelink HA,Bongers RM,Bouwsema H,Van Der Sluis CK

    更新日期:2010-06-01 00:00:00

  • Selection of an above or below-ankle orthosis for individuals with neuropathic partial foot amputation: a pilot study.

    abstract:BACKGROUND:Little evidence exists for the orthotic management for individuals diagnosed with diabetic neuropathy and partial foot amputation. OBJECTIVE:This pilot study examined differences in balance and pressure distribution while individuals wore foot orthoses inside shoes (BA) and this same orthosis combined with ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612437005

    authors: Spaulding SE,Chen T,Chou LS

    更新日期:2012-06-01 00:00:00

  • Rotational moulding in the production of prostheses.

    abstract::This paper discusses the place of rotational moulding in the provision of prosthetic shanks and shank sections. It covers the selection of thermoplastic material, the moulding conditions and their automation in a machine process, and the development of a suitable range of moulds. Also covered is the question of interf...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648509164822

    authors: Coombs AG,Lawrence RB,Davies RM

    更新日期:1985-04-01 00:00:00

  • Effect of powered gait orthosis on walking in individuals with paraplegia.

    abstract:BACKGROUND:The important purpose of a powered gait orthosis is to provide active joint movement for patients with spinal cord injury. OBJECTIVES:The aim of this study was to clarify the effect of a powered gait orthosis on the kinematics and temporal-spatial parameters in paraplegics with spinal cord injury. STUDY DE...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1177/0309364612463164

    authors: Arazpour M,Ahmadi Bani M,Kashani RV,Tabatabai Ghomshe F,Mousavi ME,Hutchins SW

    更新日期:2013-08-01 00:00:00

  • Knee disarticulation versus above-knee amputation.

    abstract::If below-knee amputation is impossible, knee disarticulation should be considered before above-knee amputation, regardless of age and etiology. Knee disarticulation which leaves the femur and patella untoched offers many advantages. The surgical technique is simple and non-traumatic since no bone or muscle tissue is t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647909164695

    authors: Baumgartner RF

    更新日期:1979-04-01 00:00:00

  • A reference shape library for computer aided socket design in above-knee prostheses.

    abstract::A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is bas...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648909079421

    authors: Torres-Moreno R,Foort J,Morrison JB,Saunders CG

    更新日期:1989-12-01 00:00:00

  • The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm.

    abstract:BACKGROUND AND AIM:DEKA Integrated Solutions Corp. (DEKA) was charged by the Defense Advanced Research Project Agency to design a prosthetic arm system that would be a dramatic improvement compared with the existing state of the art. The purpose of this article is to describe the two DEKA Arm prototypes (Gen 2 and Gen ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613506913

    authors: Resnik L,Klinger SL,Etter K

    更新日期:2014-12-01 00:00:00

  • A novel technique for fabricating an ear prosthesis in a patient with congenital ear deformity.

    abstract:BACKGROUND AND AIM:Microtia is one of the forms of ear loss and deformity. A prosthesis that is simple to apply, and which has adequate suspension and acceptable aesthetics, can be useful in the rehabilitation of patients with this deficit and can improve the social and psychological effects of patients with ear amputa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612467344

    authors: Mardani MA,Aminian G,Tabatabaian F,Arazpour M,Hutchins SW,Head JS

    更新日期:2013-08-01 00:00:00

  • Multichannel functional electrical stimulation--facts and expectations.

    abstract::Clinically applied multichannel stimulation was visualized in the very beginnings of FES. A short survey of existing multichannel systems was taken and compared to initial expectations. While much still remains to be done to get multichannel stimulation out of the research environment and into the clinical routine, th...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647709164605

    authors: Vodovnik L,Grobelnik S

    更新日期:1977-04-01 00:00:00

  • Nordic clinical guidelines for orthotic treatment of osteoarthritis of the knee: A systematic review using the AGREE II instrument.

    abstract:BACKGROUND:High-quality clinical practice guidelines are necessary for effective use of resources both at an individual patient- and national-level. Nordic clinical practice guidelines recommendations for orthotic treatment of knee osteoarthritis vary and little is known about their quality. OBJECTIVES:The aim of the ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364619857854

    authors: Jarl G,Hellstrand Tang U,Nordén E,Johannesson A,Rusaw DF

    更新日期:2019-10-01 00:00:00

  • Walking in a vacuum-assisted socket shifts the stump fluid balance.

    abstract::Gains in stump volume have been documented in trans-tibial amputees while walking in custom made under-sized, total surface-bearing, vacuum-assisted sockets (Board et al., 2001). These gains raised doubts as to whether the sockets were truly under-sized and concerns that using an over-sized socket with vacuum-assist c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640308726666

    authors: Goswami J,Lynn R,Street G,Harlander M

    更新日期:2003-08-01 00:00:00

  • Development of clinical guidelines for the prescription of orthoses in patients with neurological disorders in The Netherlands.

    abstract::The objective of this study was to develop guidelines for the prescription of ankle-foot, knee, wrist-hand and elbow orthoses for patients with neurological disorders. The study is part of a more comprehensive study focusing on the development of clinical guidelines for the prescription of these orthoses in a wider pa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640500533232

    authors: Hijmans JM,Geertzen JH

    更新日期:2006-04-01 00:00:00

  • Is there any relationship between orthotic usage and functional activities in children with neuromuscular disorders?

    abstract:BACKGROUND:Contractures of Achilles tendons and gastrocnemius muscle deteriorate the performance in daily living activities of patients with neuromuscular diseases. Ankle-foot orthoses help to prevent the progression of deformities and to obtain optimal position of the joints to support standing and walking. OBJECTIVE...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613486915

    authors: Alemdaroğlu İ,Gür G,Bek N,Yilmaz ÖT,Yakut Y,Uygur F,Karaduman A

    更新日期:2014-02-01 00:00:00

  • Tolerance of early walking with total contact among below-knee amputees--a randomized test.

    abstract::In order to reduce the need for repeated changes of socket due to postoperative atrophy and resorption of oedema simple temporary limbs are required to delay the casting of individual sockets until the stump is more mature. A randomized study of 95 below-knee amputees was performed with a re-usable temporary one-size ...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.3109/03093648309166980

    authors: Liedberg E,Hommerberg H,Persson BM

    更新日期:1983-08-01 00:00:00