Abstract:
:The objective of this study was to develop guidelines for the prescription of ankle-foot, knee, wrist-hand and elbow orthoses for patients with neurological disorders. The study is part of a more comprehensive study focusing on the development of clinical guidelines for the prescription of these orthoses in a wider patient population. Evidence from literature (reviews, randomized controlled trials with good quality), information from literature with a lower degree of evidence and information from structured interviews with experts in the field of orthotics, form the basis of statements presented in a Delphi procedure. The Delphi technique was used to gain consensus on statements published on the Internet. A group of experts in the field of orthotics and neurological disorders was asked to give their opinion on 41 statements. Statements with a general agreement of at least 75% were accepted. Statements with less general agreement were rewritten and the experts could react in a second and possibly in a third round. Afterwards, an opinion-based workshop was organized in which participants could react on preliminary guidelines and on Delphi-statements with between 65% and 75% agreement. Consensus on 32 statements was gained during the three rounds and the opinion-based workshop. These statements form the basis of the consensus based clinical guidelines for the prescription of orthoses in patients with neurological disorders.
journal_name
Prosthet Orthot Intjournal_title
Prosthetics and orthotics internationalauthors
Hijmans JM,Geertzen JHdoi
10.1080/03093640500533232subject
Has Abstractpub_date
2006-04-01 00:00:00pages
35-43issue
1eissn
0309-3646issn
1746-1553journal_volume
30pub_type
杂志文章abstract:BACKGROUND AND AIM:DEKA Integrated Solutions Corp. (DEKA) was charged by the Defense Advanced Research Project Agency to design a prosthetic arm system that would be a dramatic improvement compared with the existing state of the art. The purpose of this article is to describe the two DEKA Arm prototypes (Gen 2 and Gen ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364613506913
更新日期:2014-12-01 00:00:00
abstract:BACKGROUND:In 2003, the British Society of Rehabilitation Medicine (BSRM) published guidelines on amputee and prosthetic rehabilitation, including those with congenital limb deficiency. OBJECTIVES:The aim of the study was to evaluate the service provided by the Regional Disablement Service (RDS) to children with conge...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364611427070
更新日期:2012-03-01 00:00:00
abstract::The swing-phase motion of the shank of an above-knee prosthesis has been modelled mathematically. An inexpensive endoskeletal prosthesis was designed using the Jaipur foot and conduit pipes with a hinge joint for the knee. Results of field trials and the modelling indicate that a very simple above-knee prosthesis can ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649209164323
更新日期:1992-08-01 00:00:00
abstract::Pushchairs for adults are used by two distinct groups: the high dependency users who cannot walk or use a self-propelling chair and the occasional users who may be able to walk indoors but are unable to walk significant distances outdoors. In the past, both disparate groups were provided with similar wheelchairs descr...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649109164274
更新日期:1991-04-01 00:00:00
abstract:BACKGROUND:Increased foot temperature among individuals with type 2 diabetes can be predictive of diabetic foot ulcer development. A combination of physiological and mechanical deficiencies may contribute to elevations in intact foot temperature during gait for individuals with type 2 diabetes and transtibial amputatio...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364620968642
更新日期:2020-12-07 00:00:00
abstract::A simple alignment apparatus and the method of transferring the offset test load to the prosthetic assembly through an aligned mandrel for the principal structural tests in accordance with ISO 10328 is presented. The new alignment apparatus was used to prepare test specimens consisting of traditional laminated prosthe...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093640008726554
更新日期:2000-12-01 00:00:00
abstract:BACKGROUND::Orthotic treatment for adolescent idiopathic scoliosis is a mainstay in nonoperative treatment to prevent progressive spinal deformity. OBJECTIVE::To determine the effectiveness of the Providence orthosis in the treatment of adolescent idiopathic scoliosis. STUDY DESIGN::Retrospective review. METHODS::Pa...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364618792727
更新日期:2019-04-01 00:00:00
abstract:BACKGROUND:Orthotic treatment of idiopathic toe walking is complicated by the lack of a known etiology. This study compared control of toe walking using an articulated ankle-foot orthosis versus a rigid carbon fiber footplate attached to a foot orthosis. OBJECTIVES:Ascertain differences between two orthoses in the con...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,随机对照试验
doi:10.1177/0309364614564023
更新日期:2016-04-01 00:00:00
abstract::Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterize a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093640903585024
更新日期:2010-03-01 00:00:00
abstract:BACKGROUND AND AIM:Partial hand amputations are common in developing countries and have a negative impact on patients and their families' quality of life. The uniqueness of each partial hand amputation, coupled with the relatively high costs of prostheses, makes it challenging to provide suitable prosthetic solutions i...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364620905220
更新日期:2020-04-01 00:00:00
abstract::The Locomotor Capability Index (LCI) is widely used for assessing goals and achievements of patients receiving prostheses. The Stanmore-Kingston Splat method for graphical display of the results has previously been described and is based on four levels of achievement for each of the 14 tasks in the index. Recently a m...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093640903214083
更新日期:2009-12-01 00:00:00
abstract::The i-LIMB hand is a novel upper limb myoelectric prosthetic hand with several joints in the fingers and thumb. This study aimed to determine whether this new device had more functionality than a more conventional myoelectric prosthetic hand with only a single joint between the thumb and two fingers. Therefore, a 45-y...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093641003767207
更新日期:2010-06-01 00:00:00
abstract::A post-clinical investigation has been carried out among 42 unilateral amputees who lost their hand due to an accident. The investigation was directed at two main topics of interest. Firstly the amputee, the problems he has to cope with, and the role the prosthesis plays in his life; and secondly the prosthesis, its u...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648309166586
更新日期:1983-12-01 00:00:00
abstract::Transfer of Musculus Latissimus dorsi/M. Teres major to the rotator cuff with or without M. Subscapularis/M. Pectoralis release is a widely used procedure for restoring shoulder abduction and external rotation in squeal of obstetric brachial plexus palsy. After the operation a shoulder abduction orthosis in maximal ex...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093640802015755
更新日期:2008-06-01 00:00:00
abstract::A CAD (computer aided design) analysis software package (CADVIEW) was designed for use with prosthetic and orthotic CAD CAM (computer aided design/computer aided manufacture) systems. Using the Microsoft Windows 3.1 environment, CADVIEW provides a series of anatomical shape viewing and analysis tools. These tools incl...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649409164393
更新日期:1994-08-01 00:00:00
abstract::This paper describes functional outcome of a population of lower limb amputees five months after amputation compared with their preoperative functional abilities and studies the relationship between potential determinants and functional outcome. Twenty out of 26 patients who underwent a lower limb amputation between D...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649609164423
更新日期:1996-08-01 00:00:00
abstract:BACKGROUND:Diabetes mellitus is a leading cause of major lower extremity amputation. OBJECTIVE:To examine the influence of gender, level of amputation and diabetes mellitus status on being fit with a prosthetic limb following lower extremity amputation for peripheral arterial disease. STUDY DESIGN:Retrospective analy...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364616628341
更新日期:2017-02-01 00:00:00
abstract:BACKGROUND:The devastating earthquake in Sichuan in 2008 has left many adolescent amputees. However, little research has been focused on the adolescent amputees who have high potential to return to premorbid activity level. OBJECTIVES:To investigate daily step activities and prosthesis-related quality of life of the a...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364614556837
更新日期:2016-02-01 00:00:00
abstract::The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees by C Beatriz Samitier, Lluis Guirao, Maria Costea, Josep M Camós, and Eulogio Pleguezuelos. Prosthetics and Orthotics International 2016; 40: 83-88, DOI: 10.1177/0309364614546927. ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,已发布勘误
doi:10.1177/0309364616648557
更新日期:2016-08-01 00:00:00
abstract::This paper discusses the place of rotational moulding in the provision of prosthetic shanks and shank sections. It covers the selection of thermoplastic material, the moulding conditions and their automation in a machine process, and the development of a suitable range of moulds. Also covered is the question of interf...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648509164822
更新日期:1985-04-01 00:00:00
abstract::In a prospective, controlled study, 186 prosthetic rubber feet of different designs were fitted to amputees with trans-tibial prostheses. There were 158 amputees available for follow-up. The amputee compliance was good and 89% were satisfied with their device. After 18 months of use one VI-Solid rubber foot from VVAF ...
journal_title:Prosthetics and orthotics international
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1080/03093640600794692
更新日期:2006-08-01 00:00:00
abstract::The effect of one years general use on the performance of four shock attenuating insoles is reported. Testing was carried out using the JP Biomechanics Shock Meter on twelve volunteers on a timed oval course at eight intervals during the year. The results show that two of the insoles perform well (Viscolas and PPT) al...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649009080322
更新日期:1990-08-01 00:00:00
abstract::This paper reviews the literature comparing the results obtained in applying regimes involving motion with those involving rest following injury or surgery. The deleterious effects of immobilisation are compared to those obtained under conditions of passive motion and intermittent passive motion. It is concluded that ...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,评审
doi:10.3109/03093649309164369
更新日期:1993-08-01 00:00:00
abstract::In the present study the psychophysical detection threshold levels mechanical stimulation of 32 prosthetic limbs were determined. Prosthetic limbs were anchored to the bone by means of an implant (n=17) or supported by a socket enclosing the amputation stump (n=15). Detection threshold levels were assessed for pressur...
journal_title:Prosthetics and orthotics international
pub_type: 临床试验,杂志文章
doi:10.1080/03093640008726536
更新日期:2000-08-01 00:00:00
abstract::This paper reviews and summarizes the evidence for important observations of normal and pathological gait and presents an approach to rehabilitation and orthotic management, which is based on the significance of shank and thigh kinematics for standing and gait. It discusses normal gait biomechanics, challenging some t...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章,评审
doi:10.3109/03093646.2010.485597
更新日期:2010-09-01 00:00:00
abstract::One of the most important problems for the bilateral upper limb deficient patient is the inability to manage toileting activities. Dependence in this area precludes schooling or work. This paper surveys available clothing types and adaptations to facilitate doffing and donning clothing and devices for genital cleansin...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093648009103112
更新日期:1980-04-01 00:00:00
abstract::Recent work suggests that a prosthetic ankle-foot component's roll-over shape - the effective rocker it conforms to between initial contact and opposite initial contact (the 'roll-over' interval of walking) - is closely linked to its final alignment in the prosthesis (as determined by a skilled prosthetist using heuri...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1080/03093640802366158
更新日期:2008-12-01 00:00:00
abstract::In Europe, bespoke orthopaedic shoes are usually sent for a trial fitting in order to check the fit and indicate any modifications required before final finishing. The use of shell shoes at the fit assessment stage, rather than the traditional alternative of partially or fully finished shoes, can offer service advanta...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.3109/03093649509168002
更新日期:1995-12-01 00:00:00
abstract:BACKGROUND:The role of the prosthetist has changed substantially over the past century. In the transition from 'limb-maker' to 'clinician', the expectations of prosthetics professionals have also changed. OBJECTIVES:To develop and test a new scale capable of assessing and comparing current expectations of the roles of...
journal_title:Prosthetics and orthotics international
pub_type: 杂志文章
doi:10.1177/0309364617698519
更新日期:2018-04-01 00:00:00
abstract:BACKGROUND:The important purpose of a powered gait orthosis is to provide active joint movement for patients with spinal cord injury. OBJECTIVES:The aim of this study was to clarify the effect of a powered gait orthosis on the kinematics and temporal-spatial parameters in paraplegics with spinal cord injury. STUDY DE...
journal_title:Prosthetics and orthotics international
pub_type: 临床试验,杂志文章
doi:10.1177/0309364612463164
更新日期:2013-08-01 00:00:00