HRC adjustable pneumatic swing-phase control knee.

Abstract:

:Since 1972 the Hyogo Rehabilitation Centre has been developing a variable-resistance-type pneumatic control device, the HRC Adjustable Pneumatic Swing-Phase Control Knee. Successful field tests have been carried out on 20 cases with Model IV since 1973 with only a limited number of mechanical troubles. This paper introduces the HRC adjustable pneumatic swing-phase control knee with follow-up studies.

journal_name

Prosthet Orthot Int

authors

Nakamura S,Sawamura S

doi

10.3109/03093647809166698

subject

Has Abstract

pub_date

1978-12-01 00:00:00

pages

137-42

issue

3

eissn

0309-3646

issn

1746-1553

journal_volume

2

pub_type

杂志文章
  • The mobile arm support.

    abstract::The Mobile Arm Support, conceived and researched by Dr. Radulovic, is intended for the use of patients whose arm is afflicted. The support consists of a supporting harness, an articulated splint on which the arm is fixed and a pneumatic system of elevation that counterbalances the weight of the arm. Its originality li...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648009164573

    authors: Radulovic R,Piera JB,Cassagne B,Grossiord A,Boruchowitsch G

    更新日期:1980-08-01 00:00:00

  • Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets.

    abstract::This study served as a pilot to develop the methodology for a larger number of clinical trials. Ten trans-tibial amputees compared sockets made by conventional methods with sockets made using computer aided socket design (CASD). Prosthetists, paired for experience, fitted each subject with one prosthesis using each me...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648609164519

    authors: Holden JM,Fernie GR

    更新日期:1986-12-01 00:00:00

  • Comparison of the efficacy of laterally wedged insoles and bespoke unloader knee orthoses in treating medial compartment knee osteoarthritis.

    abstract:BACKGROUND:Patients suffering from medial compartment knee osteoarthritis (OA) may be treated with unloader knee orthoses or laterally wedged insoles. OBJECTIVES:The aim of this study was to identify and compare the effects of them on the gait parameters and pain in these patients. STUDY DESIGN:Quasi-experimental. M...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612447094

    authors: Arazpour M,Bani MA,Maleki M,Ghomshe FT,Kashani RV,Hutchins SW

    更新日期:2013-02-01 00:00:00

  • Threshold concepts in prosthetics.

    abstract:BACKGROUND:Curriculum documents identify key concepts within learning prosthetics. Threshold concepts provide an alternative way of viewing the curriculum, focussing on the ways of thinking and practicing within prosthetics. Threshold concepts can be described as an opening to a different way of viewing a concept. This...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616679317

    authors: Hill S

    更新日期:2017-12-01 00:00:00

  • Measuring foam model shapes with a contact digitizer.

    abstract:BACKGROUND AND AIM:It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE:A controlled laboratory study was c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364610394478

    authors: Sanders JE,Severance MR

    更新日期:2011-06-01 00:00:00

  • Evaluation of a novel powered hip orthosis for walking by a spinal cord injury patient: a single case study.

    abstract:BACKGROUND:The aim of this case study was to identify the effect of a powered hip orthosis on the kinematics and temporal-spatial parameters of walking by a patient with spinal cord injury (SCI). CASE DESCRIPTION AND METHODS:Two orthoses were evaluated while worn by an incomplete SCI subject with a T-8level of injury....

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364611431482

    authors: Arazpour M,Chitsazan A,Hutchins SW,Ghomshe FT,Mousavi ME,Takamjani EE,Aminian G,Rahgozar M,Bani MA

    更新日期:2012-03-01 00:00:00

  • The i-LIMB hand and the DMC plus hand compared: a case report.

    abstract::The i-LIMB hand is a novel upper limb myoelectric prosthetic hand with several joints in the fingers and thumb. This study aimed to determine whether this new device had more functionality than a more conventional myoelectric prosthetic hand with only a single joint between the thumb and two fingers. Therefore, a 45-y...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093641003767207

    authors: Otr OV,Reinders-Messelink HA,Bongers RM,Bouwsema H,Van Der Sluis CK

    更新日期:2010-06-01 00:00:00

  • Custom skiing and trekking adaptations for a trans-tibial and trans-radial quadrilateral amputee.

    abstract::A keen skier who is a trans-tibial and trans-radial quadrilateral amputee sought an improved adaptation for skiing from the Rehabilitation Engineering Service in Edinburgh. The unpredictable nature of the bending moments and loads that can be imposed on the prostheses during skiing raised concern about the suitability...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093640409167927

    authors: Farley R,Mitchell F,Griffiths M

    更新日期:2004-04-01 00:00:00

  • The stump capping procedure to prevent or treat terminal osseous overgrowth.

    abstract::Terminal overgrowth in transverse deficiencies and in amputations, particularly of the humerus and tibia necessitate serial trimming procedures or re-amputation. Capping using an autogenous bone graft or a titanium and polyethylene endoprosthetic cap provides a satisfactory way of avoiding these re-amputations and all...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164641

    authors: Pfeil J,Marquardt E,Holtz T,Niethard FU,Schneider E,Carstens C

    更新日期:1991-08-01 00:00:00

  • Shock absorption during transtibial amputee gait: Does longitudinal prosthetic stiffness play a role?

    abstract:BACKGROUND:Reduced-stiffness components are often prescribed in lower-limb prostheses, but their efficacy in augmenting shock absorption has been inconclusive. OBJECTIVES:To perform a systematic variation of longitudinal prosthetic stiffness over a wide range of values and to evaluate its effect on shock absorption du...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616640945

    authors: Boutwell E,Stine R,Gard S

    更新日期:2017-04-01 00:00:00

  • Preliminary experiences with modified SACH feet manufactured and used in a tropical developing world setting.

    abstract::In a prospective study of polypropylene (PP) prostheses for trans-tibial amputees four different modified SACH feet were used. These are identified as: 1. BAVI from the national manufacturer of componentry in BaVi; 2. HCMC a design initiated by the International Committee of the Red Cross (ICRC) together with the Army...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649909071641

    authors: Jensen JS,Heim S

    更新日期:1999-12-01 00:00:00

  • Quality of life of persons with transfemoral amputation: Comparison of socket prostheses and osseointegrated prostheses.

    abstract:BACKGROUND:Until recently, no study had compared the quality of life of persons with transfemoral amputation treated with osseointegration to socket prosthesis users. OBJECTIVES:Comparison of quality of life in two types of prostheses users: a cohort of patients with osseointegration and patients equipped with a socke...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620948649

    authors: Pospiech PT,Wendlandt R,Aschoff HH,Ziegert S,Schulz AP

    更新日期:2020-08-25 00:00:00

  • Residual limb fluid volume change and volume accommodation: Relationships to activity and self-report outcomes in people with trans-tibial amputation.

    abstract:BACKGROUND:Fluctuations in limb volume degrade prosthesis fit and require users to accommodate changes using management strategies, such as donning and doffing prosthetic socks. OBJECTIVES:To examine how activities and self-report outcomes relate to daily changes in residual limb fluid volume and volume accommodation....

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364617752983

    authors: Sanders JE,Youngblood RT,Hafner BJ,Ciol MA,Allyn KJ,Gardner D,Cagle JC,Redd CB,Dietrich CR

    更新日期:2018-08-01 00:00:00

  • The ICEROSS concept: a discussion of a philosophy.

    abstract::Prefabricated ICEROSS (Icelandic Roll On Silicone Socket) sockets have been in use in Iceland since early 1986. Use of custom-made silicone sockets began several years earlier, and a paper devoted to the subject was presented at the 1984 AOPA Assembly by the author of this article. The ICEROSS system is primarily used...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649309164354

    authors: Kristinsson O

    更新日期:1993-04-01 00:00:00

  • Rotational moulding in the production of prostheses.

    abstract::This paper discusses the place of rotational moulding in the provision of prosthetic shanks and shank sections. It covers the selection of thermoplastic material, the moulding conditions and their automation in a machine process, and the development of a suitable range of moulds. Also covered is the question of interf...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648509164822

    authors: Coombs AG,Lawrence RB,Davies RM

    更新日期:1985-04-01 00:00:00

  • Passive prosthetic hands and tools: A literature review.

    abstract:BACKGROUND:The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no re...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364617691622

    authors: Maat B,Smit G,Plettenburg D,Breedveld P

    更新日期:2018-02-01 00:00:00

  • RTV silicone insoles.

    abstract::A cheap and fast method of providing long term accommodating insoles is described. Room temperature vulcanizing (RTV) silicone rubber is used, with suitable coverings, to provide pain relief and support for feet and ankles. The combination of physical properties of the finished item provides a useful balance between s...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648409145347

    authors: Pratt DJ,Rees PH,Butterworth RH

    更新日期:1984-04-01 00:00:00

  • Exercise programs to improve gait performance in people with lower limb amputation: A systematic review.

    abstract:BACKGROUND:Few studies have explored the effects of exercise on gait performance in people with lower limb amputations. OBJECTIVES:To (1) summarize the effects of exercise programs on gait performance and (2) assess the overall quality of the evidence for adults ambulating with leg prostheses. STUDY DESIGN:Systematic...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364614546926

    authors: Wong CK,Ehrlich JE,Ersing JC,Maroldi NJ,Stevenson CE,Varca MJ

    更新日期:2016-02-01 00:00:00

  • Movement quality of conventional prostheses and the DEKA Arm during everyday tasks.

    abstract:BACKGROUND:Conventional prosthetic devices fail to restore the function and characteristic movement quality of the upper limb. The DEKA Arm is a new, advanced prosthesis featuring a compound, powered wrist and multiple grip configurations. OBJECTIVES:The purpose of this study was to determine if the DEKA Arm improved ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616631348

    authors: Cowley J,Resnik L,Wilken J,Smurr Walters L,Gates D

    更新日期:2017-02-01 00:00:00

  • The effect of custom carbon ankle-foot orthosis alignment on roll-over shape and center of pressure velocity.

    abstract:BACKGROUND:Maintaining an optimal rolling of the foot over the ground is thought to increase the stability and efficiency of pathologic gait. Ankle-foot orthoses are often prescribed to improve gait mechanics in individuals with lower extremity injuries; however, their design may compromise how the foot rolls over the ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620971407

    authors: Russell Esposito E,Ruble MD,Ikeda AJ,Wilken JM

    更新日期:2020-11-21 00:00:00

  • The treatment of longitudinal ulnar deficiency.

    abstract::Longitudinal ulnar deficiency, whose detailed anatomy is varied, is often accompanied by other abnormalities and appears as part of several syndromes. The history of its classification is reviewed, and the treatments, which have been offered, described. Follow-up of a series shows that the function achieved is good an...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164643

    authors: Lovett RJ

    更新日期:1991-08-01 00:00:00

  • Relating minimum toe clearance to prospective, self-reported, trip-related stumbles in the community.

    abstract:BACKGROUND:Individuals with transtibial amputation are at increase risk of falling. The absence of an ankle joint and the associated musculature in these individuals can reduce clearance between the prosthetic foot and ground during the swing phase of gait, which may increase the risk of stumbling and in turn falling. ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364616650085

    authors: Rosenblatt NJ,Bauer A,Grabiner MD

    更新日期:2017-08-01 00:00:00

  • Removable rigid dressings: a retrospective case-note audit to determine the validity of post-amputation application.

    abstract::This study investigated the validity of post-amputation application of removable rigid dressings (RRDs) for trans-tibial amputees, regarding preparation for prosthetic management and key rehabilitation timelines. It was hypothesised that the use of RRDs would result in faster preparation of the residual limb for prost...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802016795

    authors: Taylor L,Cavenett S,Stepien JM,Crotty M

    更新日期:2008-06-01 00:00:00

  • Melorheostosis--an unusual cause of amputation.

    abstract::A 24-year-old female developed, in infancy, progressive right upper and lower limb muscle and soft tissue contractures and had a diagnosis of melorheostosis made on X-ray and pathological specimens. At the age of 11 years she began to have pain in the right hip and lower limb and this later became the dominant feature...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/17461550500066808

    authors: Graham LE,Parke RC

    更新日期:2005-04-01 00:00:00

  • Long term comparison of some shock attenuating insoles.

    abstract::The effect of one years general use on the performance of four shock attenuating insoles is reported. Testing was carried out using the JP Biomechanics Shock Meter on twelve volunteers on a timed oval course at eight intervals during the year. The results show that two of the insoles perform well (Viscolas and PPT) al...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649009080322

    authors: Pratt DJ

    更新日期:1990-08-01 00:00:00

  • A newly developed socket design for a knee disarticulation amputee who is an active athlete.

    abstract::This case report describes a newly developed socket design for a world class knee disarticulation athlete. To meet the demands concerning especially the suspension of the prosthesis a new type of socket was developed. The socket is made from carbon fibres and polyaramid fibres and is designed with a slit in the socket...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640208726624

    authors: Tingleff H,Jensen L

    更新日期:2002-04-01 00:00:00

  • Management of proximal femoral focal deficiency with limited resources in Haiti.

    abstract:BACKGROUND:Individuals with proximal femoral focal deficiency (PFFD) present with a shortened femur. This report highlights the process used to determine prosthetic candidacy, a novel use of the International Committee of the Red Cross (ICRC) prosthetic materials, and subsequent rehabilitation when treating in rural Ha...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612447095

    authors: Lamberg EM,Collins CK,Hanks JE,Alaniz MB

    更新日期:2013-02-01 00:00:00

  • Pedorthic management of the diabetic foot.

    abstract:BACKGROUND:Conservative pedorthic management of the diabetic foot has been shown to be an effective method to prevent ulcers, amputations, and re-amputations. This article exhibits why and how pedorthics plays such an important role via modalities such as footwear, shoe modifications, custom foot orthoses, and partial ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364614535233

    authors: Janisse D,Janisse E

    更新日期:2015-02-01 00:00:00

  • Walking in a vacuum-assisted socket shifts the stump fluid balance.

    abstract::Gains in stump volume have been documented in trans-tibial amputees while walking in custom made under-sized, total surface-bearing, vacuum-assisted sockets (Board et al., 2001). These gains raised doubts as to whether the sockets were truly under-sized and concerns that using an over-sized socket with vacuum-assist c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640308726666

    authors: Goswami J,Lynn R,Street G,Harlander M

    更新日期:2003-08-01 00:00:00

  • Integration of surface electromyographic sensors with the transfemoral amputee socket: a comparison of four differing configurations.

    abstract:BACKGROUND AND AIM:In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical int...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613516484

    authors: Hefferman GM,Zhang F,Nunnery MJ,Huang H

    更新日期:2015-04-01 00:00:00