New walking aid for primary mobilization of an infant with deficiency of all four limbs.

Abstract:

:The authors report on a new device for the primary mobilization of a boy with severe deficiencies of all four limbs. This device allows independent mobility.

journal_name

Prosthet Orthot Int

authors

Balogh S,Gönczy T,Bujdosó R,Kullmann L

doi

10.3109/03093649409164671

subject

Has Abstract

pub_date

1994-04-01 00:00:00

pages

49-51

issue

1

eissn

0309-3646

issn

1746-1553

journal_volume

18

pub_type

杂志文章
  • Effects of alignment on the roll-over shapes of prosthetic feet.

    abstract::Recent work suggests that a prosthetic ankle-foot component's roll-over shape - the effective rocker it conforms to between initial contact and opposite initial contact (the 'roll-over' interval of walking) - is closely linked to its final alignment in the prosthesis (as determined by a skilled prosthetist using heuri...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802366158

    authors: Hansen A

    更新日期:2008-12-01 00:00:00

  • Nighttime bracing with the Providence thoracolumbosacral orthosis for treatment of adolescent idiopathic scoliosis: A retrospective consecutive clinical series.

    abstract:BACKGROUND::Orthotic treatment for adolescent idiopathic scoliosis is a mainstay in nonoperative treatment to prevent progressive spinal deformity. OBJECTIVE::To determine the effectiveness of the Providence orthosis in the treatment of adolescent idiopathic scoliosis. STUDY DESIGN::Retrospective review. METHODS::Pa...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618792727

    authors: Davis L,Murphy JS,Shaw KA,Cash K,Devito DP,Schmitz ML

    更新日期:2019-04-01 00:00:00

  • Upper limb prosthesis use and abandonment: a survey of the last 25 years.

    abstract::This review presents an analytical and comparative survey of upper limb prosthesis acceptance and abandonment as documented over the past 25 years, detailing areas of consumer dissatisfaction and ongoing technological advancements. English-language articles were identified in a search of Ovid, PubMed, and ISI Web of S...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1080/03093640600994581

    authors: Biddiss EA,Chau TT

    更新日期:2007-09-01 00:00:00

  • Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets.

    abstract::This study served as a pilot to develop the methodology for a larger number of clinical trials. Ten trans-tibial amputees compared sockets made by conventional methods with sockets made using computer aided socket design (CASD). Prosthetists, paired for experience, fitted each subject with one prosthesis using each me...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648609164519

    authors: Holden JM,Fernie GR

    更新日期:1986-12-01 00:00:00

  • Tolerance of early walking with total contact among below-knee amputees--a randomized test.

    abstract::In order to reduce the need for repeated changes of socket due to postoperative atrophy and resorption of oedema simple temporary limbs are required to delay the casting of individual sockets until the stump is more mature. A randomized study of 95 below-knee amputees was performed with a re-usable temporary one-size ...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.3109/03093648309166980

    authors: Liedberg E,Hommerberg H,Persson BM

    更新日期:1983-08-01 00:00:00

  • A walking bout reveals altered foot thermodynamics associated with unilateral transtibial amputation among individuals with type 2 diabetes.

    abstract:BACKGROUND:Increased foot temperature among individuals with type 2 diabetes can be predictive of diabetic foot ulcer development. A combination of physiological and mechanical deficiencies may contribute to elevations in intact foot temperature during gait for individuals with type 2 diabetes and transtibial amputatio...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364620968642

    authors: Leister KR,Wurdeman SR

    更新日期:2020-12-07 00:00:00

  • Pushchairs.

    abstract::Pushchairs for adults are used by two distinct groups: the high dependency users who cannot walk or use a self-propelling chair and the occasional users who may be able to walk indoors but are unable to walk significant distances outdoors. In the past, both disparate groups were provided with similar wheelchairs descr...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164274

    authors: van Ross E

    更新日期:1991-04-01 00:00:00

  • Evaluation of the psychophysical detection threshold level for vibrotactile and pressure stimulation of prosthetic limbs using bone anchorage or soft tissue support.

    abstract::In the present study the psychophysical detection threshold levels mechanical stimulation of 32 prosthetic limbs were determined. Prosthetic limbs were anchored to the bone by means of an implant (n=17) or supported by a socket enclosing the amputation stump (n=15). Detection threshold levels were assessed for pressur...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1080/03093640008726536

    authors: Jacobs R,Brånemark R,Olmarker K,Rydevik B,Van Steenberghe D,Brånemark PI

    更新日期:2000-08-01 00:00:00

  • Walking in a vacuum-assisted socket shifts the stump fluid balance.

    abstract::Gains in stump volume have been documented in trans-tibial amputees while walking in custom made under-sized, total surface-bearing, vacuum-assisted sockets (Board et al., 2001). These gains raised doubts as to whether the sockets were truly under-sized and concerns that using an over-sized socket with vacuum-assist c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640308726666

    authors: Goswami J,Lynn R,Street G,Harlander M

    更新日期:2003-08-01 00:00:00

  • Effect of powered gait orthosis on walking in individuals with paraplegia.

    abstract:BACKGROUND:The important purpose of a powered gait orthosis is to provide active joint movement for patients with spinal cord injury. OBJECTIVES:The aim of this study was to clarify the effect of a powered gait orthosis on the kinematics and temporal-spatial parameters in paraplegics with spinal cord injury. STUDY DE...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1177/0309364612463164

    authors: Arazpour M,Ahmadi Bani M,Kashani RV,Tabatabai Ghomshe F,Mousavi ME,Hutchins SW

    更新日期:2013-08-01 00:00:00

  • Biomechanical improvements following foot strike biofeedback training for a patient using a passive dynamic ankle-foot orthosis during running.

    abstract:BACKGROUND AND PURPOSE:Passive dynamic ankle-foot orthoses have potential to facilitate return to running after a lower limb trauma. However, transitioning patients to new movement patterns that enhance passive dynamic ankle-foot orthoses benefits can pose a challenge. The purpose of this case study was to report biome...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364619851935

    authors: Yoder AJ,Mazzone BN,Miltenberger RS,Farrokhi S

    更新日期:2019-08-01 00:00:00

  • Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test.

    abstract:BACKGROUND:The functional performance of currently available body-powered prostheses is unknown. OBJECTIVE:The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. STUDY DESIGN:Experimental trial. METHODS:A total of 21 ab...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614554030

    authors: Haverkate L,Smit G,Plettenburg DH

    更新日期:2016-02-01 00:00:00

  • Comparison of the efficacy of laterally wedged insoles and bespoke unloader knee orthoses in treating medial compartment knee osteoarthritis.

    abstract:BACKGROUND:Patients suffering from medial compartment knee osteoarthritis (OA) may be treated with unloader knee orthoses or laterally wedged insoles. OBJECTIVES:The aim of this study was to identify and compare the effects of them on the gait parameters and pain in these patients. STUDY DESIGN:Quasi-experimental. M...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612447094

    authors: Arazpour M,Bani MA,Maleki M,Ghomshe FT,Kashani RV,Hutchins SW

    更新日期:2013-02-01 00:00:00

  • Comparison of gait between healthy participants and persons with spinal cord injury when using the advanced reciprocating gait orthosis.

    abstract:BACKGROUND:The advanced reciprocating gait orthosis (ARGO) has a rigid structure which provides restricted movement at the hip, knee, and ankle joints and incorporates a pelvic section with an extended section in the lumbar region. Healthy subjects, when walking with an RGO in situ, could feasibly demonstrate the level...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364615592699

    authors: Arazpour M,Joghtaei M,Bahramizadeh M,Ahmadi Bani M,Hutchins SW,Curran S,Mousavi ME,Sharifi G,Mardani MA

    更新日期:2016-04-01 00:00:00

  • SMARTWheel: From concept to clinical practice.

    abstract::Wheelchair prescription is complex with thousands of choices and options. Theoretically, a higher quality or innovative wheelchair that is appropriately matched to the user and their unique needs will increase participation. It is well accepted that there is an alarmingly high incidence of carpal tunnel syndrome, and ...

    journal_title:Prosthetics and orthotics international

    pub_type: 历史文章,杂志文章

    doi:10.1080/03093640903082126

    authors: Cooper RA

    更新日期:2009-09-01 00:00:00

  • The efficacy of powered orthoses on walking in persons with paraplegia.

    abstract:BACKGROUND:Powered orthoses are a new generation of assistive devices for people with spinal cord injury, which are designed to induce motion to paralyzed lower limb joints using external power via electric motors or pneumatic or hydraulic actuators. OBJECTIVE:Powered gait orthoses provide activated movement of lower ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364613520031

    authors: Arazpour M,Hutchins SW,Ahmadi Bani M

    更新日期:2015-04-01 00:00:00

  • Measuring foam model shapes with a contact digitizer.

    abstract:BACKGROUND AND AIM:It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE:A controlled laboratory study was c...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364610394478

    authors: Sanders JE,Severance MR

    更新日期:2011-06-01 00:00:00

  • A new approach for the pistoning measurement in transtibial prosthesis.

    abstract:BACKGROUND:Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning. STUDY DESIGN:Clinical trial. OBJECTIVES:To introduce and evaluate a new simple method for measuring the pistoning between the soft liner and...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1177/0309364611423130

    authors: Gholizadeh H,Abu Osman NA,Lúvíksdóttir Á,Eshraghi A,Kamyab M,Wan Abas WA

    更新日期:2011-12-01 00:00:00

  • Total surface bearing self suspending above-knee sockets.

    abstract::A new type of above-knee socket has been designed to provide total surface support and to dispense with ischial bearing as the primary weight bearing area. The socket is based upon the hypothesis that if the soft tissues of an above-knee stump are adequately supported in a suitably shaped container they will behave un...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647909103096

    authors: Redhead RG

    更新日期:1979-12-01 00:00:00

  • Knee disarticulation versus above-knee amputation.

    abstract::If below-knee amputation is impossible, knee disarticulation should be considered before above-knee amputation, regardless of age and etiology. Knee disarticulation which leaves the femur and patella untoched offers many advantages. The surgical technique is simple and non-traumatic since no bone or muscle tissue is t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093647909164695

    authors: Baumgartner RF

    更新日期:1979-04-01 00:00:00

  • Toileting self-care methods for bilateral high level upper limb amputees.

    abstract::One of the most important problems for the bilateral upper limb deficient patient is the inability to manage toileting activities. Dependence in this area precludes schooling or work. This paper surveys available clothing types and adaptations to facilitate doffing and donning clothing and devices for genital cleansin...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648009103112

    authors: Friedmann L

    更新日期:1980-04-01 00:00:00

  • The physical effect of lumbar spinal supports.

    abstract::A study has been performed to investigate the physical effects of lumbar spinal supports. Two groups were studied, a group of normal male subjects and a group of male low back pain patients. Five different spinal supports were investigated and their effects upon the skin temperature, spinal movements and intra-abdomin...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648209166772

    authors: Grew ND,Deane G

    更新日期:1982-08-01 00:00:00

  • Compliance to service standards for congenital upper limb deficiency: the Northern Ireland experience.

    abstract:BACKGROUND:In 2003, the British Society of Rehabilitation Medicine (BSRM) published guidelines on amputee and prosthetic rehabilitation, including those with congenital limb deficiency. OBJECTIVES:The aim of the study was to evaluate the service provided by the Regional Disablement Service (RDS) to children with conge...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364611427070

    authors: Hillan J,Graham LE

    更新日期:2012-03-01 00:00:00

  • A comparison of trial shoe and shell shoe fitting techniques.

    abstract::In Europe, bespoke orthopaedic shoes are usually sent for a trial fitting in order to check the fit and indicate any modifications required before final finishing. The use of shell shoes at the fit assessment stage, rather than the traditional alternative of partially or fully finished shoes, can offer service advanta...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649509168002

    authors: Chen RC,Lord M

    更新日期:1995-12-01 00:00:00

  • Manufacturing custom-contoured wheelchair seating: A state-of-the-art review.

    abstract:BACKGROUND:Custom-contoured wheelchair seating lowers risk of pressure injury and postural deterioration while custom-contoured wheelchair seating lowers risk of pressure injury and postural deterioration while increasing the stability and functional activity of the wheelchair occupant. Producing custom-contoured seati...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364619836028

    authors: Nace S,Tiernan J,Ní Annaidh A

    更新日期:2019-08-01 00:00:00

  • A study of 200 cases of congenital limb deficiencies.

    abstract::An analysis of 200 patients with congenital limb deficiency who attended the Artificial Limb Centre, Pune from January 1984 to April 1990 is presented. This group is representative of the congenital limb deficient population of the country. The commonest deficiencies were transverse phalangeal total/partial deficiency...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164402

    authors: Jain SK

    更新日期:1994-12-01 00:00:00

  • The ICEROSS concept: a discussion of a philosophy.

    abstract::Prefabricated ICEROSS (Icelandic Roll On Silicone Socket) sockets have been in use in Iceland since early 1986. Use of custom-made silicone sockets began several years earlier, and a paper devoted to the subject was presented at the 1984 AOPA Assembly by the author of this article. The ICEROSS system is primarily used...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649309164354

    authors: Kristinsson O

    更新日期:1993-04-01 00:00:00

  • Step count accuracy of StepWatch and FitBit One™ among individuals with a unilateral transtibial amputation.

    abstract:BACKGROUND:Step counts, obtained via activity monitors, provide insight into activity level in the free-living environment. Accuracy assessments of activity monitors are limited among individuals with lower-limb amputations. OBJECTIVES:(1) To evaluate the step count accuracy of both monitors during forward-linear and ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618767138

    authors: Arch ES,Sions JM,Horne J,Bodt BA

    更新日期:2018-10-01 00:00:00

  • The i-LIMB hand and the DMC plus hand compared: a case report.

    abstract::The i-LIMB hand is a novel upper limb myoelectric prosthetic hand with several joints in the fingers and thumb. This study aimed to determine whether this new device had more functionality than a more conventional myoelectric prosthetic hand with only a single joint between the thumb and two fingers. Therefore, a 45-y...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093641003767207

    authors: Otr OV,Reinders-Messelink HA,Bongers RM,Bouwsema H,Van Der Sluis CK

    更新日期:2010-06-01 00:00:00

  • A reference shape library for computer aided socket design in above-knee prostheses.

    abstract::A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is bas...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648909079421

    authors: Torres-Moreno R,Foort J,Morrison JB,Saunders CG

    更新日期:1989-12-01 00:00:00