Value of modern sonography in the assessment of meniscal lesions.

Abstract:

:The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age=36.2 years, range=16-70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1-4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI>25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries.

journal_name

Eur J Radiol

authors

Wareluk P,Szopinski KT

doi

10.1016/j.ejrad.2011.09.013

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

2366-9

issue

9

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(11)00695-4

journal_volume

81

pub_type

杂志文章
  • Local thermal ablation of renal cell carcinoma.

    abstract:PURPOSE:With evolving local thermal ablation technology, the clinical application of thermal ablation has been actively investigated in the treatment for renal cell carcinoma. We review the evolution and current status of radiofrequency ablation and microwave ablation for renal cell carcinoma. MATERIALS AND METHODS:Al...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2010.12.056

    authors: Feng B,Liang P

    更新日期:2012-03-01 00:00:00

  • Clinical utility of real-time ultrasound-multimodality fusion guidance for percutaneous biopsy of focal liver lesions.

    abstract:OBJECTIVES:To prospectively evaluate the clinical value of real-time ultrasonography (US)-computed tomography (CT)/magnetic resonance imaging (MRI) fusion imaging for percutaneous needle biopsy of focal liver lesions (FLLs), and to compare its biopsy success rate with that of conventional US-guided biopsy in a propensi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.04.002

    authors: Ahn SJ,Lee JM,Chang W,Lee SM,Kang HJ,Yang HK,Han JK

    更新日期:2018-06-01 00:00:00

  • Comparison of automated 4-chamber cardiac views versus axial views for measuring right ventricular enlargement in patients with suspected pulmonary embolism.

    abstract:PURPOSE:Compare the right ventricle to left ventricle (RV/LV) diameter ratio obtained from axial pulmonary CT angiograms (CTPA) with those derived from automatically generated 4-chamber (4-CH) reformats in patients with suspected pulmonary embolism (PE). METHODS:In this institutional review board-approved study we inc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.041

    authors: Wittenberg R,van Vliet JW,Ghaye B,Peters JF,Schaefer-Prokop CM,Coche E

    更新日期:2012-02-01 00:00:00

  • Assessment of cardiac implantable electric device lead perforation using a metal artifact reduction algorithm in cardiac computed tomography.

    abstract:PURPOSE:CT is considered the non-invasive gold standard for evaluating cardiac implantable electronic devices (CIEDs) lead perforation, but metal artifacts caused by the lead tip affect the image quality and make a definitive diagnosis challenging. We compared the performances of the metal artifact reduction (MAR) algo...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2021.109530

    authors: Kidoh M,Oda S,Nakato K,Sakabe D,Kanazawa H,Takashio S,Nakaura T,Nagayama Y,Sasao A,Hatemura M,Funama Y,Kaikita K,Tsujita K,Ikeda O,Azuma M,Hirai T

    更新日期:2021-01-09 00:00:00

  • Mesenchymal hamartoma of the liver in infant: its roentgen diagnosis.

    abstract::A case of mesenchymal hamartoma of the liver in an 18-month-old boy is reported. CT and US revealed a large, cystic tumour surrounded by a thick wall. In the lower portion of the tumour, a small solid component was recognized on CT. Angiography revealed marked arterial displacement, fine tumour vessels and a large rad...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Egawa T,Kuroda C,Yoshioka H,Hori S,Tokunaga K,Fukui Y,Ikeda Y,Okada A,Sakurai M

    更新日期:1983-11-01 00:00:00

  • Arterial calcification and long-term outcome in chronic limb-threatening ischemia patients.

    abstract:PURPOSE:Within five years after presentation 50-60% of patients with chronic limb-threatening ischemia (CLI) have died or had an amputation. We assessed the predictive value of lower extremity arterial calcification on computed tomography (CT) characteristics on both 7-years amputation-free survival and 10-years all-ca...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109305

    authors: Konijn LCD,Takx RAP,de Jong PA,Spreen MI,Veger HTC,Mali WPTM,van Overhagen H

    更新日期:2020-11-01 00:00:00

  • Assessment of right ventricular dysfunction in end-stage renal disease patients on maintenance haemodialysis by cardiac magnetic resonance imaging.

    abstract:PURPOSE:To assess right ventricular (RV) dysfunction in end-stage renal disease (ESRD) patients on maintenance haemodialysis (HD) by cardiac magnetic resonance (CMR) imaging and determined the risk factors associated with RV dysfunction. MATERIALS AND METHODS:Fifty ESRD patients on maintenance HD and 16 age- and gende...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.02.036

    authors: Peng W,Li Z,Xu H,Xia C,Guo Y,Zhang J,Liu K,Li Y,Pu J,Zhang H,Cui T

    更新日期:2018-05-01 00:00:00

  • MRI of the cardiomyopathies.

    abstract::We examined the potentialities of Magnetic resonance imaging (MRI) in the evaluation of the main cardiomyopathies: hypertrophic, dilated, restrictive and arrhythmogenic right ventricular. The hypertrophic cardiomyopathy is generally adequately investigated by echocardiography, that well defines the myocardial thickeni...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(01)00311-4

    authors: Di Cesare E

    更新日期:2001-06-01 00:00:00

  • Pancreatic neuroendocrine tumors: Correlation between the contrast-enhanced computed tomography features and the pathological tumor grade.

    abstract:OBJECTIVE:To determine whether CT features can predict the pathological tumor grades of pancreatic neuroendocrine tumors (PanNETs) according to the recent WHO classification. MATERIALS AND METHODS:In all, 28 patients with histologically confirmed PanNETs underwent preoperative contrast CT examinations. Thirteen tumors...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.05.005

    authors: Takumi K,Fukukura Y,Higashi M,Ideue J,Umanodan T,Hakamada H,Kanetsuki I,Yoshiura T

    更新日期:2015-08-01 00:00:00

  • Malignant pleural mesothelioma: computed tomography and correlation with histology.

    abstract:OBJECTIVE:To review the computed tomography (CT) imaging findings of pleural mesothelioma at presentation and to correlate the CT with the histological subtype. MATERIALS AND METHODS:Pathology reports from 1997 to 2006 were reviewed at two academic institutions to identify patients with proven pleural mesothelioma. Di...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.02.004

    authors: Seely JM,Nguyen ET,Churg AM,Müller NL

    更新日期:2009-06-01 00:00:00

  • Peritoneal cavity circumference on computed tomography predicts outcomes in acute pancreatitis.

    abstract:OBJECTIVES:We investigated the role of novel intra-abdominal parameters measured by computed tomography (CT) in the prediction of clinical outcomes in acute pancreatitis (AP). METHODS:Patients with AP underwent an abdominal CT scan on admission to define different intra-abdominal parameters (abdominal circumference, p...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109327

    authors: Monreal-Robles R,Kohn-Gutiérrez AE,Sordia-Ramírez J,Zúñiga-Segura JA,Palafox-Salinas JA,de la Rosa-Pacheco S,Elizondo-Riojas G,González-González JA

    更新日期:2020-11-01 00:00:00

  • Triage for suspected acute Pulmonary Embolism: Think before opening Pandora's Box.

    abstract::This is a review of the current strengths and weaknesses of the various imaging modalities available for the diagnosis of suspected non-massive Pulmonary Embolism (PE). Without careful consideration for the clinical presentation, and the timely application of clinical decision support (CDS) methodology, the current ov...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.03.023

    authors: Levin D,Seo JB,Kiely DG,Hatabu H,Gefter W,van Beek EJ,Schiebler ML,2013 International Workshop for Pulmonary Functional Imaging (IWPFI).

    更新日期:2015-06-01 00:00:00

  • Interstitial lung disease in anti-synthetase syndrome: initial and follow-up CT findings.

    abstract:PURPOSE:To describe the initial and follow-up CT features of interstitial lung disease associated with anti-synthetase syndrome (AS-ILD). MATERIALS AND METHODS:Two independent thoracic radiologists retrospectively analysed thin-section CT images obtained at diagnosis of AS-ILD in 33 patients (17 positive for anti-Jo1,...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.026

    authors: Debray MP,Borie R,Revel MP,Naccache JM,Khalil A,Toper C,Israel-Biet D,Estellat C,Brillet PY

    更新日期:2015-03-01 00:00:00

  • Contrast-enhanced ultrasound study of primary hepatic angiosarcoma: a pitfall of non-enhancement.

    abstract:OBJECTIVE:To investigate the contrast-enhanced ultrasound (CEUS) characteristics of primary hepatic angiosarcoma (PHA). METHODS:The sonographic findings and CEUS images of PHA in three patients were retrospectively analyzed. RESULTS:In our study, 3 cases of PHA (2 multiple nodules and 1 solitary mass) showed similar ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.06.026

    authors: Wang L,Lv K,Chang XY,Xia Y,Yang ZY,Jiang YX,Dai Q,Tan L,Li JC

    更新日期:2012-09-01 00:00:00

  • Digital fluoroscopic radiology: evaluation of the clinical impact.

    abstract::The use of digital image intensifier radiography (DIIR) for examinations in projection radiography is becoming more common. Fluoroscopic controlled contrast studies (barium- or iodine-based), particularly of the gastrointestinal tract, can be performed quickly and easily with a considerable decrease in radiation expos...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(93)90021-e

    authors: Lehmann KJ,Busch HP,Georgi M

    更新日期:1993-06-01 00:00:00

  • A dynamic phantom for generation of contrast bolus curves for the evaluation of digital subtraction angiography systems.

    abstract::A solid dynamic phantom has been constructed, which allows quantitative measurements of the signal-to-noise ratios in processed images from digital subtraction angiography (DSA) units. Profiles of silicone rubber placed in concentric circles on a plate which is rotated in the image plane generates bolus curves with fi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(90)90104-j

    authors: Hansson IB,Axelsson B,Nordell B

    更新日期:1990-07-01 00:00:00

  • Classification, staging and prognosis of lung cancer.

    abstract::Lung cancer has increased in incidence throughout the twentieth century and is now the most common cancer in the Western World. It has a poor prognosis, only 10-15% of patients survive 5 years or longer. Outcome is dependent on clinical stage and cancer cell type. Lung cancer is broadly subclassified on the basis of h...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(02)00287-5

    authors: Beadsmoore CJ,Screaton NJ

    更新日期:2003-01-01 00:00:00

  • Investigating the correlation of arterial spin labeling and dynamic contrast enhanced perfusion in primary tumor of nasopharyngeal carcinoma.

    abstract:PURPOSE:This prospective study aimed to investigate the correlation between two perfusion methods: arterial spin labeling (ASL) and dynamic contrast enhanced (DCE) technique in patients with nasopharyngeal carcinoma (NPC) and to optimize ASL protocol. MATERIALS AND METHODS:Forty-five newly diagnosed NPC patients under...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.09.034

    authors: Lin M,Yu X,Luo D,Ouyang H,Xie L,Wu B,Zhou C

    更新日期:2018-11-01 00:00:00

  • Respiratory-gated ¹⁸F-FDG PET/CT for the diagnosis of liver metastasis.

    abstract:PURPOSE:To ascertain the role of respiratory-gated PET/CT with (18)F-fluorodeoxyglucose ((18)F-FDG) for accurate diagnosis of liver metastasis. MATERIALS AND METHODS:Forty patients with suspected liver metastasis underwent conventional whole-body PET/CT scan initially, followed by respiratory-gated PET/CT scan coverin...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.05.019

    authors: Suenaga Y,Kitajima K,Aoki H,Okunaga T,Kono A,Matsumoto I,Fukumoto T,Tanaka K,Sugimura K

    更新日期:2013-10-01 00:00:00

  • Molecular imaging of apoptosis in cancer.

    abstract::Apoptosis plays an important role in cancer. Mechanisms hindering its action are implicated in a number of malignancies. Also, the induction of apoptosis plays a pivotal role in non-surgical cancer treatment regimes such as irradiation, chemotherapy, or hormones. Recent advanced in imaging science have made it now pos...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.03.016

    authors: Hakumäki JM,Liimatainen T

    更新日期:2005-11-01 00:00:00

  • Functional connectivity disruption of the substantia nigra associated with cognitive impairment in acute mild traumatic brain injury.

    abstract:PURPOSE:Mild traumatic brain injury is known to have frequent cognitive impairment. Accumulating evidence is pointing to the malfunctioning of the substantia nigra (SN) as an important factor for head trauma. However, it remains unknown whether changes in the SN-based resting state functional connectivity following mTB...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.03.002

    authors: Lu L,Li F,Ma Y,Chen H,Wang P,Peng M,Chen YC,Yin X

    更新日期:2019-05-01 00:00:00

  • Ultrasound in Crohn's disease of the small bowel.

    abstract:OBJECTIVE:The purpose of this work is to prospectively evaluate high resolution ultrasonography with graded compression in the ability to detect Crohn's disease of the small bowel (CDSB) together with its complications and activity signs, compared with enteroclysis, CT and immunoscintigraphy in the mirror of the final ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(00)00240-0

    authors: Tarján Z,Tóth G,Györke T,Mester A,Karlinger K,Makó EK

    更新日期:2000-09-01 00:00:00

  • Delayed-enhancement magnetic resonance imaging at 3.0T using 0.15mmol/kg of contrast agent for the assessment of chronic myocardial infarction.

    abstract:OBJECTIVE:A recent international, multicenter, double-blinded, randomized trial shows delayed-enhanced magnetic resonance imaging (DE-MRI) using contrast doses of ≥0.2mmol/kg is effective in the detection and assessment of myocardial infarction (MI), and 0.1mmol/kg is not enough; intermediate doses between 0.1 and 0.2m...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2014.01.012

    authors: Yang J,Ma H,Liu J,Wang C,Shi Y,Xie H,Huo F,Liu F,Lin K

    更新日期:2014-05-01 00:00:00

  • Synthesized image processing in clinical neurosurgery.

    abstract::In an effort to achieve efficient image management in clinical neurosurgery utilizing a local image filing system (EFPACS, Fuji Electric Co., Ltd), adequate image-processing and display techniques were developed. One is a method whereby the anatomical location of the thalamic and basal ganglion lesions is determined b...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(90)90092-p

    authors: Kikuchi K,Kowada M,Ogayama H,Sasanuma J,Watanabe K

    更新日期:1990-01-01 00:00:00

  • Perfusion CT imaging of treatment response in oncology.

    abstract::Perfusion CT was first described in the 1970s but has become accepted as a clinical technique in recent years. In oncological practice Perfusion CT allows the downstream effects of therapies on the tumour vasculature to be monitored. From the dynamic changes in tumour and vascular enhancement following intravenous iod...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.03.022

    authors: Prezzi D,Khan A,Goh V

    更新日期:2015-12-01 00:00:00

  • Small hepatocellular carcinoma: assessment with T1-weighted spin-echo magnetic resonance imaging with and without fat suppression.

    abstract:OBJECTIVE:We examined the detectability of small hepatocellular carcinomas (HCCs) and the factors that affect hyperintensity of small HCC on T1-weighted images (T1W) by using T1-weighted fat-suppressed images (T1FS). METHODS:Thirty-nine HCCs (29 patients) measuring 30 mm or less were enrolled. The mean size of HCCs wa...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(01)00346-1

    authors: Koushima Y,Ebara M,Fukuda H,Morimoto N,Sugiura N,Yoshikawa M,Sanada M,Saisho H,Matsumoto T,Yukawa M

    更新日期:2002-01-01 00:00:00

  • Spinal cord injury caused by a lateral C1-2 puncture for cervical myelography.

    abstract::A case is reported of a metrizamide injection into the cervical spinal cord during myelography via a lateral C1-2 puncture. This resulted in a mild persistent neurological deficit. The literature is reviewed. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Müller-Vahl H,Vogelsang H

    更新日期:1986-05-01 00:00:00

  • Image guided percutaneous splenic interventions.

    abstract:AIM:The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. MATERIALS AND METHODS:We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous s...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.02.011

    authors: Kang M,Kalra N,Gulati M,Lal A,Kochhar R,Rajwanshi A

    更新日期:2007-10-01 00:00:00

  • Monitoring of liver glycogen synthesis in diabetic patients using carbon-13 MR spectroscopy.

    abstract::To investigate the relationship between liver glucose, glycogen, and plasma glucose in diabetic patients, in vivo liver carbon-13 magnetic resonance spectroscopy ((13)C MRS) with a clinical 3.0T MR system was performed. Subjects were healthy male volunteers (n=5) and male type-2 diabetic patients (n=5). Pre- and durin...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.10.019

    authors: Tomiyasu M,Obata T,Nishi Y,Nakamoto H,Nonaka H,Takayama Y,Autio J,Ikehira H,Kanno I

    更新日期:2010-02-01 00:00:00

  • Magnetic resonance angiography in transjugular intrahepatic portosystemic stenting: comparison with contrast hepatic and portal venography.

    abstract::In order to highlight the role of magnetic resonance angiography [MRA] in the assessment of patients pre-transjugular intrahepatic portosystemic shunt (TIPS) stenting, the MRA images of portal and hepatic veins of 21 patients were compared with the images from contrast portal and hepatic venograms performed on the sam...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)00559-u

    authors: Eustace S,Buff B,Kruskal J,Roizental M,Finn JP,Longmaid HE,Stokes K,Hartnell GC

    更新日期:1994-11-01 00:00:00