Ultrasound in Crohn's disease of the small bowel.

Abstract:

OBJECTIVE:The purpose of this work is to prospectively evaluate high resolution ultrasonography with graded compression in the ability to detect Crohn's disease of the small bowel (CDSB) together with its complications and activity signs, compared with enteroclysis, CT and immunoscintigraphy in the mirror of the final diagnosis. METHODS AND MATERIAL:In a series of 73 consecutive patients, who were referred for enteroclysis with suspected Crohn's disease of the small bowel computed tomography (CT), ultrasound (US), immunoscintigraphy with 99mTc labeled monoclonal antigranulocyte antibody (AGAb) examinations were performed within 10 days from each other. For the final evaluation the diagnosis of CDSB was based on combination of clinical and enteroclysis findings (73 cases) and in 17 cases additional surgical and pathological data were available. The results of other modalities were blinded to the radiologists performing and reading out the exams. The diagnostic values of each modality was assessed also in those 18 patients, who had early Crohn's disease. In the group of 43 patients with proven CDSB who had all the four imaging modalities, the modalities were compared in their ability to demonstrate various pathological conditions related to CD. Increased (>500 ml/min) flow measured by Doppler US in the superior mesenteric artery and increased color signs in the gut wall seen by power Doppler sonography were compared to CDAI. RESULTS:Of the 73 patients the combination of enteroclysis and clinical tests demonstrated CDSB in 47. The sensitivity, specificity and accuracy of ultrasound were 88.4, 93.3 and 90.4%, respectively. Enteroclysis was the most accurate method. CT was more sensitive than US, but less specific. The accuracy of US, CT and scintigraphy were similar. In the group of 18 patients, who had early CDSB, the sensitivity of US decreased to only 67%, CT and scintigraphy had higher values. Intra- and perimural abscesses, and sinus tracts were also more frequently visualized by US, especially if they were small. US was superior than CT in detecting stenoses and skip lesions, but inferior to enteroclysis. US and CT detected more fistulas, than enteroclysis. Compared to CT, US detected more cases with mesenteric lymphadenopathy, equal cases with abscesses and free peritoneal fluids. In detecting mesenteric inflammatory proliferation CT, and in detecting colonic involvement CT and immunoscintigraphy were slightly superior than graded compression US. Patterns of mural stratification detected by ultrasound correlated well with the enteroclysis severity stages. There was only 59% agreement between increased superior mesenteric artery flow detected by Doppler sonography and CDAI, and 60.5% agreement between increased number of Color pixels in the gut wall measured by power Doppler and increased CDAI. CONCLUSION:High resolution graded compression sonography is a valuable tool for detecting small intestinal Crohn's disease. It has similar diagnostic values as CT. However in early disease the sensitivity substantially decreases. In known Crohn's disease for following disease course, evaluating relapses and extramural manifestations US is an excellent tool. Doppler and Power Doppler activity measurements do not correlate well with the more widespread clinical activity index.

journal_name

Eur J Radiol

authors

Tarján Z,Tóth G,Györke T,Mester A,Karlinger K,Makó EK

doi

10.1016/s0720-048x(00)00240-0

keywords:

subject

Has Abstract

pub_date

2000-09-01 00:00:00

pages

176-82

issue

3

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(00)00240-0

journal_volume

35

pub_type

杂志文章
  • T1 mapping for detection of left ventricular myocardial fibrosis in hypertrophic cardiomyopathy: a preliminary study.

    abstract:PURPOSE:To investigate the diagnostic value of T1 mapping imaging of evaluating fibrosis in patients with hypertrophic cardiomyopathy (HCM). MATERIALS AND METHODS:21 subjects with HCM and 18 healthy volunteers underwent conventional late gadolinium enhancement (LGE) imaging and T1 mapping imaging. The region of myocar...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.12.014

    authors: Lu M,Zhao S,Yin G,Jiang S,Zhao T,Chen X,Tian L,Zhang Y,Wei Y,Liu Q,He Z,Xue H,An J,Shah S

    更新日期:2013-05-01 00:00:00

  • Thrombocytopenic thrombotic purpura: severe clinic with no CT, minor MRI, but a SPECT correlate.

    abstract::A 28-year-old woman with primarily therapy refractory TTP was followed neuroradiologically over 6 months. Despite pronounced neurological and neuropsychiatric symptoms including hemiparesis and aphasia she had unremarkable CT scans on two occasions. Three MRI exams showed no correlate for her neurological symptoms exc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(98)00088-6

    authors: Baron Y,Bargemann T,Harten P,Gutschmidt HJ

    更新日期:1999-07-01 00:00:00

  • Differentiation between benign and malignant colon tumors using fast dynamic gadolinium-enhanced MR colonography; a feasibility study.

    abstract:BACKGROUND:Colorectal cancer will present itself as a bowel obstruction in 16-23% of all cases. However, not all obstructing tumors are malignant and the differentiation between a benign and a malignant tumor can be difficult. The purpose of our study was to determine whether fast dynamic gadolinium-enhanced MR imaging...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.033

    authors: Achiam MP,Andersen LP,Klein M,Løgager V,Chabanova E,Thomsen HS,Rosenberg J

    更新日期:2010-06-01 00:00:00

  • Joint impingement syndrome: clinical features.

    abstract::Joint impingement is a painful syndrome caused by the friction of joint tissues, which is both the cause and the effect of altered joint biomechanics. From the anatomical and clinical viewpoints, these syndromes are classified as bone impingement, soft tissue impingement and entrapment neuropathy, depending on what jo...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(98)00041-2

    authors: Billi A,Catalucci A,Barile A,Masciocchi C

    更新日期:1998-05-01 00:00:00

  • New-born infants with severe hyaline membrane disease: radiological evaluation during high frequency oscillatory versus conventional ventilation.

    abstract:OBJECTIVE:The aim of our study was to determine the impact of treatment with exogenous surfactant (ES) and high frequency oscillatory ventilation (HFOV) on the radiological appearance and clinical course of hyaline membrane disease (HMD) in new-born infants. MATERIALS AND METHODS:New-born infants (18) (median weight, ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)00153-8

    authors: Helbich TH,Popow C,Dobner M,Wunderbaldinger P,Zekert M,Herold CJ

    更新日期:1998-10-01 00:00:00

  • Value of diagnosis and differential diagnosis of MRI and MR spectroscopy in gliomatosis cerebri.

    abstract:PURPOSE:The purpose of this study was to characterize gliomatosis cerebri on magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), and to analyze the value of these two techniques in diagnosis and differential diagnosis of gliomatosis cerebri. MATERIALS AND METHODS:MR images of 14 patients with g...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.03.001

    authors: Yu A,Li K,Li H

    更新日期:2006-08-01 00:00:00

  • Postoperative imaging of gastrointestinal tract cancers.

    abstract::Assessment in postoperative complications of gastrointestinal cancers via imaging modalities is of significant importance as diagnosing the cancer. Complications can be considered as an indicator for the success of surgical procedure, and has a vital importance for the patient. In this article the implications of CT, ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00033-5

    authors: Tunaci A

    更新日期:2002-06-01 00:00:00

  • Ionizing radiation doses during lower limb torsion and anteversion measurements by EOS stereoradiography and computed tomography.

    abstract:OBJECTIVES:To calculate and compare the doses of ionizing radiation delivered to the organs by computed tomography (CT) and stereoradiography (SR) during measurements of lower limb torsion and anteversion. MATERIALS AND METHODS:A Rando anthropomorphic phantom (Alderson RANDO phantom, Alderson Research Laboratories Inc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.10.026

    authors: Delin C,Silvera S,Bassinet C,Thelen P,Rehel JL,Legmann P,Folinais D

    更新日期:2014-02-01 00:00:00

  • Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.

    abstract:PURPOSE:To evaluate the diagnostic yield and safety of computed tomography (CT) fluoroscopy-guided cutting needle biopsy (CNB) for pulmonary nodules ≤ 8 mm. METHOD:Data of CT fluoroscopy-guided CNB for pulmonary nodules ≤ 8 mm performed in a single institution were retrospectively analyzed. One hundred and seventeen b...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108903

    authors: Zhao Y,Matsui Y,Hiraki T,Iguchi T,Tomita K,Uka M,Gobara H,Toyooka S,Kanazawa S

    更新日期:2020-04-01 00:00:00

  • Advances in paediatric CNS ultrasound.

    abstract::Advanced paediatric ultrasound of the central nervous system (CNS) requires 7 MHz sector and linear transducers, equipment which is highly sensitive to flow velocity (Power Doppler) and additional transcranial axial, coronal and sagittal imaging. New diagnostic possibilities include recognition of subarachnoid hemorrh...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(97)00087-9

    authors: Winkler P

    更新日期:1998-01-01 00:00:00

  • Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence.

    abstract:PURPOSE:The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. MATERIALS AND METHODS:Forty-five patients with cranial nerve symptoms referable to the...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2003.10.019

    authors: Ciftci E,Anik Y,Arslan A,Akansel G,Sarisoy T,Demirci A

    更新日期:2004-09-01 00:00:00

  • Radiologic total lung capacity measurement. Development and evaluation of a computer-based system.

    abstract::The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Seeley GW,Mazzeo J,Borgstrom M,Hunter TB,Newell JD,Bjelland JC

    更新日期:1986-11-01 00:00:00

  • Breast imaging reporting and data system (BI-RADS) lexicon for breast MRI: interobserver variability in the description and assignment of BI-RADS category.

    abstract:PURPOSE:To retrospectively evaluate interobserver variability between breast radiologists when describing abnormal enhancement on breast MR examinations and assigning a BI-RADS category using the Breast Imaging Reporting and Data System (BI-RADS) terminology. MATERIALS AND METHODS:Five breast radiologists blinded to p...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.10.003

    authors: El Khoury M,Lalonde L,David J,Labelle M,Mesurolle B,Trop I

    更新日期:2015-01-01 00:00:00

  • Peritoneal cavity circumference on computed tomography predicts outcomes in acute pancreatitis.

    abstract:OBJECTIVES:We investigated the role of novel intra-abdominal parameters measured by computed tomography (CT) in the prediction of clinical outcomes in acute pancreatitis (AP). METHODS:Patients with AP underwent an abdominal CT scan on admission to define different intra-abdominal parameters (abdominal circumference, p...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109327

    authors: Monreal-Robles R,Kohn-Gutiérrez AE,Sordia-Ramírez J,Zúñiga-Segura JA,Palafox-Salinas JA,de la Rosa-Pacheco S,Elizondo-Riojas G,González-González JA

    更新日期:2020-11-01 00:00:00

  • Intravoxel incoherent motion diffusion-weighted MRI in patients with breast cancer: Correlation with tumor stroma characteristics.

    abstract:PURPOSE:To determine whether imaging parameters derived from intravoxel incoherent motion (IVIM) diffusion weighted imaging (DWI) vary according to tumor-stroma ratio(TSR) or dominant stroma type of breast cancer. METHODS:We prospectively enrolled 77 patients with breast cancer who underwent IVIM DWI on a 3.0 T MR sca...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.108686

    authors: Li Y,Wang Z,Chen F,Qin X,Li C,Zhao Y,Yan C,Wu Y,Hao P,Xu Y

    更新日期:2019-11-01 00:00:00

  • Higher precontrast CT density of the carotid plaque in the symptomatic patients.

    abstract:PURPOSE:The purpose of this study was to determine if there is a significant difference in the CT Hounsfield Unit (CTHU) of the carotid atherosclerotic plaque (CAP) on CTpre and CTartery depending on the presence of symptomatology. METHODS:Quantitative analysis of the CTHUs for the CAP was performed in 43 arteries (11...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.06.029

    authors: Park JK,Sung YH,Jeong SY,Lee JH

    更新日期:2012-09-01 00:00:00

  • Percutaneous image-guided screws meditated osteosynthesis of impeding and pathological/insufficiency fractures of the femoral neck in non-surgical cancer patients.

    abstract:AIM:To present percutaneous image-guided screw-mediated osteosynthesis (PIGSMO) for fixation of impending fractures (ImF) and non-displaced/mildly displaced pathological/insufficient fractures (PF/InF) of the femoral neck in non-surgical cancer patients. MATERIALS AND METHODS:This is a double-centre single-arm observa...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.02.022

    authors: Cazzato RL,Garnon J,Tsoumakidou G,Koch G,Palussière J,Gangi A,Buy X

    更新日期:2017-05-01 00:00:00

  • Radiomic analysis of DCE-MRI for prediction of response to neoadjuvant chemotherapy in breast cancer patients.

    abstract:OBJECTIVES:To enhance the accurate prediction of the response to neoadjuvant chemotherapy (NAC) in breast cancer patients by using a quantitative analysis of dynamic enhancement magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS:A dataset of 57 cancer patients with breast DCE-MR images acquired before NAC was...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.06.019

    authors: Fan M,Wu G,Cheng H,Zhang J,Shao G,Li L

    更新日期:2017-09-01 00:00:00

  • Computed tomographic myelography characteristics of spinal cord atrophy in juvenile muscular atrophy of the upper extremity.

    abstract::Although atrophy of the lower cervical and upper thoracic cord in juvenile muscular atrophy of distal upper extremity has been reported, the atrophic patterns of the cord, especially in the transverse section, have not been studied extensively. The aim of this study is to clarify the atrophic patterns of the cord by C...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90033-r

    authors: Hirabuki N,Mitomo M,Miura T,Hashimoto T,Kawai R,Kozuka T

    更新日期:1991-11-01 00:00:00

  • Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging.

    abstract:INTRODUCTION:Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiogra...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.02.012

    authors: Kinner S,Steinweg V,Maderwald S,Radtke A,Sotiropoulos G,Forsting M,Schroeder T

    更新日期:2014-05-01 00:00:00

  • The future of radiology augmented with Artificial Intelligence: A strategy for success.

    abstract::The rapid development of Artificial Intelligence/deep learning technology and its implementation into routine clinical imaging will cause a major transformation to the practice of radiology. Strategic positioning will ensure the successful transition of radiologists into their new roles as augmented clinicians. This p...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2018.03.019

    authors: Liew C

    更新日期:2018-05-01 00:00:00

  • Reject analysis: a pilot programme for image quality management.

    abstract::The radiographic film wastage and the different parameters affecting this wastage were analysed for a 9-week period at a 600-bed University Hospital. An overall reject rate of 7.6% was found. The different reasons for rejection were evaluated, while retake rate, relation between working experience of the personnel, am...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90067-6

    authors: Arvanitis TN,Parizel PM,Degryse HR,De Schepper AM

    更新日期:1991-05-01 00:00:00

  • Reduction in inappropriate MRI knee studies after implementation of an appropriateness checklist: Experience at a tertiary care centre.

    abstract:PURPOSE:To evaluate reduction in inappropriate knee MRI requests following implementation of a mandatory knee MRI appropriateness checklist. METHODS:A retrospective review was performed at a single tertiary care centre. A knee MRI appropriateness checklist was developed based on the ACR Appropriateness Criteria and ad...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.108781

    authors: Xu SS,Berkovitz N,Li O,Garvin G

    更新日期:2020-02-01 00:00:00

  • Digital breast tomosynthesis and breast ultrasound: Additional roles in dense breasts with category 0 at conventional digital mammography.

    abstract:PURPOSE:To compare the diagnostic performances of digital breast tomosynthesis (DBT) and ultrasound for the dense breasts with category 0 at conventional digital mammography. MATERIALS AND METHODS:This retrospective study was approved by the institutional review board, and informed consent was waived. Among the 1103 p...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.09.026

    authors: Lee WK,Chung J,Cha ES,Lee JE,Kim JH

    更新日期:2016-01-01 00:00:00

  • Can the IVIM model be used for renal perfusion imaging?

    abstract:OBJECTIVE:Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incohe...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)01161-3

    authors: Müller MF,Prasad PV,Edelman RR

    更新日期:1998-02-01 00:00:00

  • Regional changes in brain perfusion during brain maturation measured non-invasively with Arterial Spin Labeling MRI in neonates.

    abstract:PURPOSE:The purpose of this study was to evaluate if non-invasive Arterial Spin Labeling MR imaging can be used to assess changes in brain perfusion with age which reflect neonatal brain development. For this purpose regional perfusion values obtained with ASL MR imaging were evaluated as a function of postmenstrual ag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.10.013

    authors: De Vis JB,Petersen ET,de Vries LS,Groenendaal F,Kersbergen KJ,Alderliesten T,Hendrikse J,Benders MJ

    更新日期:2013-03-01 00:00:00

  • Resting-state functional connectivity MRI analysis in Human Immunodeficiency Virus and Hepatitis C Virus co-infected subjects. A pilot study.

    abstract:BACKGROUND AND PURPOSE:Hepatitis C virus (HCV) co-infection's role on cognitive impairment of human immunodeficiency virus (HIV) positive patients is still debated and functional neuroimaging evaluation on this matter is lacking. To provide further insight about HCV's neuro-effects on HIV associated neurocognitive diso...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.03.022

    authors: Corgiolu S,Barberini L,Suri JS,Mandas A,Costaggiu D,Piano P,Zaccagna F,Lucatelli P,Balestrieri A,Saba L

    更新日期:2018-05-01 00:00:00

  • 18F-FDG-PET/CT in patients with breast cancer and rising Ca 15-3 with negative conventional imaging: a multicentre study.

    abstract:OBJECTIVES:Breast cancer is the second cause of death in women in Europe and North America. The mortality of this disease can be reduced with effective therapy and regular follow up to detect early recurrence. Tumor markers are sensitive in detecting recurrent or residual disease but imaging is required to customize th...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2010.04.029

    authors: Grassetto G,Fornasiero A,Otello D,Bonciarelli G,Rossi E,Nashimben O,Minicozzi AM,Crepaldi G,Pasini F,Facci E,Mandoliti G,Marzola MC,Al-Nahhas A,Rubello D

    更新日期:2011-12-01 00:00:00

  • Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla.

    abstract:PURPOSE:To compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality. METHODS:In this institutional review board-a...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109472

    authors: Xie S,Masokano IB,Liu W,Long X,Li G,Pei Y,Li W

    更新日期:2021-02-01 00:00:00

  • Acute and repeated inhalation lung injury by 3-methoxybutyl chloroformate in rats: CT-pathologic correlation.

    abstract:OBJECTIVES:To investigate the acute and repeated pulmonary damage in Sprague-Dawley rats caused by the inhalation of 3-methoxybutyl chloroformate (3-MBCF) using computed tomography (CT), and to correlate these results with those obtained from a pathological study. METHODS:Sixty, 7-week-old rats were exposed to 3-MBCF ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.11.035

    authors: Lim YS,Chung MH,Park SH,Kim HY,Choi BG,Lim HW,Kim JA,Yoo WJ

    更新日期:2007-05-01 00:00:00