Abstract:
BACKGROUND:Contact allergy to epoxy (meth)acrylates, 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy) phenyl]propane (bis-GMA), 2,2-bis[4-(2-hydroxy-3-acryloxypropoxy)phenyl]-propane (bis-GA), 2,2-bis[4-(methacryl-oxyethoxy)phenyl] propane (bis-EMA), 2,2-bis[4-(methacryloxy)phenyl]-propane (bis-MA), and glycidyl methacrylate (GMA) is often manifested together with contact allergy to diglycidyl ether of bisphenol A (DGEBA) epoxy resin. OBJECTIVE:To analyse patterns of concomitant allergic reactions to the five epoxy (meth)acrylates in relation to exposure. METHODS:We reviewed the 1994-2008 patch test files at the Finnish Institute of Occupational Health (FIOH) for reactions to the five epoxy (meth)acrylates, and examined the patients' medical records for exposure. RESULTS:Twenty-four patients had an allergic reaction to at least one of the studied epoxy (meth)acrylates, but specific exposure was found only in five patients: two bis-GMA allergies from dental products, two bis-GA allergies from UV-curable printing inks, and one bis-GA allergy from an anaerobic glue. Only 25% of the patients were negative to DGEBA epoxy resin. CONCLUSIONS:The great majority of allergic patch test reactions to bis-GMA, bis-GA, GMA and bis-EMA were not associated with specific exposure, and cross-allergy to DGEBA epoxy resin remained a probable explanation. However, independent reactions to bis-GA indicated specific exposure. Anaerobic sealants may induce sensitization not only to aliphatic (meth)acrylates but also to aromatic bis-GA.
journal_name
Contact Dermatitisjournal_title
Contact dermatitisauthors
Aalto-Korte K,Jungewelter S,Henriks-Eckerman ML,Kuuliala O,Jolanki Rdoi
10.1111/j.1600-0536.2009.01574.xsubject
Has Abstractpub_date
2009-07-01 00:00:00pages
9-21issue
1eissn
0105-1873issn
1600-0536pii
COD1574journal_volume
61pub_type
杂志文章abstract::Tween 80 is an ethoxylated hydrophilic non-ionic surfactant, which is used for the preparation of oil-in-water emulsions in pharmaceutical products, cosmetics, and industrial detergents. Ethoxylated surfactants are polyethers and are thus easily oxidized by atmospheric oxygen to a variety of hydroperoxides, peroxides ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1997.tb00368.x
更新日期:1997-07-01 00:00:00
abstract::An experimental study is reported of the irritant potential of oil of purcellin , isopropyl palmitate, nonyl phenol, Modulan , Amerchol and Acetulan when massaged in fixed amounts into the rabbit's skin daily for 30 days. Skin biopsies provided data on the number of epithelial cell layers, cell counts of the superfici...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1984.tb00102.x
更新日期:1984-04-01 00:00:00
abstract::Vulvar tissue is more permeable than exposed skin due to differences in structure, occlusion, hydration and susceptibility to friction. The safety assessment of products that contact the vulva should account for this potentially heightened permeability. Standard clinical patch tests may not sufficiently mimic vulvar e...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/j.0105-1873.2004.00444.x
更新日期:2004-10-01 00:00:00
abstract::An outbreak of dermatitis occurred in an aircraft factory using epoxy resin composite material. Of 25 operatives, 14 gave positive patch test reactions to the composite material and/or diglycidylether of bisphenol A (DGEBA), tetraglycidyl-4,4'-methylene dianiline (TGMDA), and o-diglycidyl phthalate. This report seems ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1984.tb00931.x
更新日期:1984-08-01 00:00:00
abstract:BACKGROUND:Cobalt release from dental prostheses has been shown to elicit allergic reactions in cobalt-allergic patients. It is therefore important to investigate whether these prostheses are possible sources of sensitization. OBJECTIVES:To assess (i) cobalt release from dental prostheses and (ii) allergic reactions t...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.12649
更新日期:2016-12-01 00:00:00
abstract::3 minor resin acids and 7 commercial modified-colophony products of different origins were studied by experimental sensitization by means of a modified FCA method. All 3 resin acids were almost negative. The commercial products gave different results. While the maleic-modified product of Greek origin showed a strong s...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1990.tb03229.x
更新日期:1990-08-01 00:00:00
abstract:BACKGROUND:The diagnostic approach to drug hypersensitivity includes a detailed medical history, clinical examination, and skin testing and/or oral challenge with a culprit or alternative drug, depending on the type of reaction and the suspected drugs. Although skin testing is considered to be rather safe, cutaneous an...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/cod.12956
更新日期:2018-04-01 00:00:00
abstract::Exaggerated test conditions were frequently used to investigate the cutaneous tolerance of detergent products in the past. As the sensitivity of newly designed biometric methods is steadily improving, the trend towards more realistic test conditions should be encouraged. A hand immersion test under laboratory-controll...
journal_title:Contact dermatitis
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1600-0536.1999.tb06010.x
更新日期:1999-03-01 00:00:00
abstract::Among patients consecutively patch tested at St John's from 1984-1989, the prevalence rate of formaldehyde sensitivity was 2.2% for men and 3.7% for women. During these 6 years, 117 women were primarily sensitized by formaldehyde, of whom 61 (52%) had hand eczema. Exposure was occupational in 12% and domestic in 88%. ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1991.tb01874.x
更新日期:1991-11-01 00:00:00
abstract::A patient was found to have a delayed positive patch test to hydrocortisone on multiple testing. This proved to be due to a photoallergy with an action spectrum in the UV-A range. The patient coincidently had a polymorphous light eruption in the UV-B range. ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1978.tb03845.x
更新日期:1978-12-01 00:00:00
abstract::Drug reactions are a common problem in hospital inpatients and outpatients. Oral or parenteral drug challenges are valuable diagnostic aids, but time consuming. We review attempts to diagnose delayed hypersensitivity drug eruptions by patch testing. We review control data, and offer an operational definition that migh...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0536.1993.tb03555.x
更新日期:1993-11-01 00:00:00
abstract::"Eau de Javel" (liquid bleach) is a common cause of chromate contact allergy. A historical review explains the reasons for the addition of sodium dichromate after the First World War. The chromium content in different brands of eau de Javel has been determined by flameless atomic absorption spectrophotometry. The resu...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1980.tb03916.x
更新日期:1980-01-01 00:00:00
abstract::A cohort of initially 111 office apprentices was prospectively followed for the duration of their training (2 and 3 years, respectively). The point prevalence of (slight) irritant or atopic hand eczema was 18.9% in the initial and 25.0% in the final examinations. Altogether, 37 cases of (slight) hand eczema were noted...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:
更新日期:1998-02-01 00:00:00
abstract::Kojic acid (5-hydroxy-2-(hydroxymethyl)-4-pyrone), a fungal metabolic product, has increasingly been used as a skin-depigmenting agent in skin care products marketed in Japan since 1988. In order to determine its frequency of sensitization, during 1 year from October 1992 to September 1993, we performed patch testing ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1995.tb00832.x
更新日期:1995-01-01 00:00:00
abstract::The aim of our study was to investigate the risk and characteristics of self-reported skin diseases among hydrotherapists. We attempted to contact 400 adults who participated in 1 of 2 training courses. 248 were reached and 190 of them (76.6%) completed the questionnaires. The data were collected by means of a telepho...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.0105-1873.2005.00699.x
更新日期:2005-12-01 00:00:00
abstract::During a 5-year period, 3664 consecutive patients were patch tested in a private dermatology practice with the Standard Series of the International Contact Dermatitis Research Group (ICDRG). 454 of these were tested with one or more additional substances which were suspected of having caused their dermatitis. 194 of t...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1983.tb04396.x
更新日期:1983-07-01 00:00:00
abstract::The arylpropionic acid derivatives (APADs) ketoprofen and tiaprofenic acid can provoke photoallergic dermatitis. Possible cross-reactivity between APADs is of importance in patients using nonsteroidal anti-inflammatory drugs. Because of the similarities in chemical structures, we investigated patients with photoallerg...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1998.tb05737.x
更新日期:1998-05-01 00:00:00
abstract::The quantitative risk assessment (QRA) paradigm has been extended to evaluating the risk of induction of allergic contact dermatitis from consumer products. Sensitization QRA compares product-related, topical exposures to a safe benchmark, the sensitization reference dose. The latter is based on an experimentally or c...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.0105-1873.2003.00192.x
更新日期:2003-09-01 00:00:00
abstract::To test the screening value of the sesquiterpene lactone (SL) mix in Europe today and describe epidemiological and clinical features of Compositae-sensitive patients, the SL mix 0.1% pet. was included in the standard patch test series in 11 European clinics. 10,695 patients were tested, and 106 (1%) had positive react...
journal_title:Contact dermatitis
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1111/j.1600-0536.1999.tb05994.x
更新日期:1999-02-01 00:00:00
abstract::The laser Doppler perfusion scanning technique is an objective, non-invasive assessment method that may be used to assess patch tests. The purpose of this paper is to focus on its clinical use in individuals with light skin, tested with non-pigmented test materials. A laser Doppler perfusion imager PIM 1.0 (LDPI) is u...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1999.tb06059.x
更新日期:1999-05-01 00:00:00
abstract::The Nickel Directive will become law in the countries of the European Union in 1996. This directive states that the concentration of nickel in post assemblies (used after ear piercing) may not exceed 0.05%, that products which come into direct and prolonged contact with the skin, e.g. earrings, watchstraps or zippers,...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0536.1996.tb02386.x
更新日期:1996-11-01 00:00:00
abstract::Adverse cutaneous reactions to topically applied olive oil are seldom reported, and positive patch tests to it are mostly regarded as allergic. To evaluate such "positive" patch test reactions, 77 female (mean age: 44 years) and 23 male eczema patients (mean age: 46 years) were prospectively patch tested with freshly ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1997.tb00914.x
更新日期:1997-01-01 00:00:00
abstract::Although p-phenylenediamine (PPD) has been recognized as an extreme sensitizer for many years, the exact mechanism of sensitization has not been elucidated yet. Penetration and the ability to bind to proteins are the first two hurdles that an allergen has to overcome to be able to sensitize. This review is an overview...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/cod.12032
更新日期:2013-04-01 00:00:00
abstract:BACKGROUND:Chromium-tanned leather footwear, which releases >3 ppm hexavalent Cr(VI), may pose a risk of sensitizing and eliciting allergic dermatitis. OBJECTIVES:To determine the content and potential release of chromium in leather footwear and to discuss the prevention of chromium contact allergy and dermatitis. ME...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2011.02053.x
更新日期:2012-05-01 00:00:00
abstract::The development of topical drug products requires testing for skin toxicology reactions. A variety of patch test systems are available with which chemicals are applied to skin. The purpose of this study was to determine the skin absorption of paraphenylenediamine (PPDA) from a variety of such systems. [14C]-PPDA (1% p...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1987.tb02701.x
更新日期:1987-09-01 00:00:00
abstract::In continuation of our preceding studies, we disclose long-term experiments to test more extensively the protective power of the novel 4H Glove. 2 compounds encountered in modern electron microscopy technique, 1-hexadecene (1-HD) and 2-hydroxyethyl acrylate (2-HEA), which elicit allergic and/or toxic reactions in labo...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1992.tb00122.x
更新日期:1992-05-01 00:00:00
abstract:BACKGROUND:Cyclic acid anhydrides often cause allergic respiratory diseases, but contact urticaria because of these anhydrides has been considered rare. OBJECTIVE:We describe 21 patients diagnosed with occupational contact urticaria at the Finnish Institute of Occupational Health during the period 1990-2006. METHOD:P...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2009.01526.x
更新日期:2009-04-01 00:00:00
abstract::Erythema caused by occlusion of 3 concentrations of surfactant was quantified in vivo using a modified spectrophotometer. Standard chamber irritation test sites were evaluated objectively using the spectrophotometer and subjectively by trained observers. There was a good relationship between the instrumental and visua...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1988.tb02893.x
更新日期:1988-09-01 00:00:00
abstract::A tire assembler developed contact dermatitis from IPPD, a rubber antioxidant. The lichenoid clinical pattern corresponded histologically to lichenified dermatitis. Tire assemblers appear to acquire contact dermatitis to this aromatic amine more frequently than any other workers in the tire manufacturing industry. Pos...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1982.tb04152.x
更新日期:1982-03-01 00:00:00
abstract::Toys are a reflection of the compounds used frequently in manufacturing. Allergic contact dermatitis to potties, metal toys, and children's jewelry is well known, however, there is a broad range of skin risks in toys. With the objective to identify and publicize the associated risk of contact dermatitis in children's ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.13500
更新日期:2020-05-01 00:00:00