Pseudostenosis in vessels adjacent to intracranial aneurysms on volume-rendered 3D angiograms: a phantom study.

Abstract:

RATIONALE AND OBJECTIVE:Among artifacts on three-dimensional (3D) angiograms, pseudostenosis in vessels adjacent to intracranial aneurysms has not been described. By using a phantom, artifacts seen in vessels adjacent to intracranial aneurysms on volume-rendered 3D angiograms were assessed. MATERIALS AND METHODS:Using a 3D angiography system and a C-arm sweep, digital images were obtained with a 512 x 512 matrix. Rotation was 30 degrees /second, and frame rate was 30 frames/second. Phantom aneurysms were designed to simulate intracranial saccular aneurysms and their parent arteries. Phantoms, consisting of a cylinder (inner diameter, 2 or 4 mm) and spheres, 10, 7, 5, 3, or 2 mm in diameter, were placed at 0 degrees and 45 degrees to the axis of rotation. Two radiologists consensually recorded their findings regarding the presence and location of stenosis and its relationship to the angle of rotation. The maximum percentage of stenosis in the pseudostenosis area was measured on multiplanar reconstruction images by using a workstation computer. RESULTS:Pseudostenosis was observed in the cylinder adjacent to the sphere at both 0 degrees and 45 degrees angles; it was on a plane perpendicular to the axis of rotation. Pseudostenosis was most obvious with 10-mm spheres; it was not seen when spheres were 3 mm or less in diameter. The maximum percentage of stenosis of the pseudostenosis increased with sphere size. CONCLUSION:On volume-rendered 3D angiograms, pseudostenosis was seen in the cylinder adjacent to the sphere. The artifact lay on a plane perpendicular to the axis of rotation, and sphere size affected the artifact.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Yamura M,Hirai T,Korogi Y,Ikushima I,Yamashita Y,Oishi S

doi

10.1016/j.acra.2004.12.003

keywords:

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

305-8

issue

3

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(04)00790-1

journal_volume

12

pub_type

杂志文章
  • A review of technical advances in interventional magnetic resonance imaging.

    abstract::Initial research in the development of interventional magnetic resonance (MR) imaging in the late 1980s and early to mid-1990s focused on pulse sequences, devices, and clinical applications. This focus was largely a result of the limited number of areas in which the academic research community leading the development ...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2005.06.003

    authors: Elgort DR,Duerk JL

    更新日期:2005-09-01 00:00:00

  • Influence of using manual or automatic breast density information in a mass detection CAD system.

    abstract:RATIONALE AND OBJECTIVES:The goal of this article is to analyze and compare the performance of a developed mass computer-aided detection (CAD) system that takes breast density information into account when using manual or automatic breast density annotations in the training step. The advantages of considering this brea...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.04.013

    authors: Oliver A,Lladó X,Freixenet J,Martí R,Pérez E,Pont J,Zwiggelaar R

    更新日期:2010-07-01 00:00:00

  • Comparison of three methods for estimating the standard error of the area under the curve in ROC analysis of quantitative data.

    abstract:RATIONALE AND OBJECTIVES:Several methods have been proposed for estimating the standard error (SE) of the area under the curve (AUC) in receiver operating characteristic analysis. The authors examined the validity of three methods--the LABROC procedure, exponential approximation, and the method of DeLong et al (purely ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80561-5

    authors: Hajian-Tilaki KO,Hanley JA

    更新日期:2002-11-01 00:00:00

  • 3D Printing of Preoperative Simulation Models of a Splenic Artery Aneurysm: Precision and Accuracy.

    abstract:RATIONALE AND OBJECTIVES:Three-dimensional (3D) printing is attracting increasing attention in the medical field. This study aimed to apply 3D printing to the production of hollow splenic artery aneurysm models for use in the simulation of endovascular treatment, and to evaluate the precision and accuracy of the simula...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.015

    authors: Takao H,Amemiya S,Shibata E,Ohtomo K

    更新日期:2017-05-01 00:00:00

  • Lung nodule CAD software as a second reader: a multicenter study.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this multicenter, multireader study was to evaluate the performance of computed tomography (CT) lung nodule computer-aided detection (CAD) software as a second reader. METHODS AND MATERIALS:The study involved 109 patients from four sites. The data were collected from a variety o...

    journal_title:Academic radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.acra.2007.09.027

    authors: White CS,Pugatch R,Koonce T,Rust SW,Dharaiya E

    更新日期:2008-03-01 00:00:00

  • Does biopsy, aspiration or six-month follow-up of a false-positive mammogram reduce future screening or have large psychosocial effects?

    abstract:RATIONALE AND OBJECTIVES:To determine the differences in the psychosocial effects and future mammography screening behavior between women who had an abnormal mammogram followed either by percutaneous or open surgical breast biopsy or cyst aspiration, or by short-term follow-up mammography to provide insight to radiolog...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)00382-9

    authors: Currence BV,Pisano ED,Earp JA,Moore A,Chiu YF,Brown ME,Kurgat KL

    更新日期:2003-11-01 00:00:00

  • Attenuation of contrast material-induced renal artery vasoconstriction by nitric oxide donors.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the role of the endothelium and associated endothelial pathways in contrast material-induced renal vasoconstriction. MATERIALS AND METHODS:Isometric contractions in human and rabbit renal artery rings with intact and denuded endothelium were stimulated with phenylephrine an...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(97)80254-1

    authors: Drescher P,Madsen PO

    更新日期:1997-12-01 00:00:00

  • High-resolution magnetic resonance imaging and conventional magnetic resonance imaging on a standard field-strength magnetic resonance system compared to arthroscopy in patients with suspected meniscal tears.

    abstract:RATIONALE AND OBJECTIVES:We sought to evaluate the diagnostic performance of high-resolution magnetic resonance imaging (MRI) and conventional MRI of the knee on a standard-field-strength MRI system compared to arthroscopic findings in patients with suspected meniscal tears. MATERIALS AND METHODS:Forty-two patients (2...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.02.007

    authors: Nemec SF,Marlovits S,Trattnig S,Matzek W,Mayerhoefer ME,Krestan CR

    更新日期:2008-07-01 00:00:00

  • Longitudinal changes in airway remodeling and air trapping in severe asthma.

    abstract:RATIONALE AND OBJECTIVES:Previous cross-sectional studies have demonstrated that airway wall thickness and air trapping are greater in subjects with severe asthma than in those with mild-to-moderate asthma. However, a better understanding of how airway remodeling and lung density change over time is needed. This study ...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.acra.2014.05.001

    authors: Witt CA,Sheshadri A,Carlstrom L,Tarsi J,Kozlowski J,Wilson B,Gierada DS,Hoffman E,Fain SB,Cook-Granroth J,Sajol G,Sierra O,Giri T,O'Neill M,Zheng J,Schechtman KB,Bacharier LB,Jarjour N,Busse W,Castro M,NHLBI Sever

    更新日期:2014-08-01 00:00:00

  • Role of intracellular calcium stores in contrast medium-induced renal vasoconstriction.

    abstract:RATIONALE AND OBJECTIVES:Renovascular smooth muscle contractility, an important factor in contrast media-induced nephrotoxicity, depends on intracellular Ca2+ concentration, which is composed of extracellular Ca2+ influx and intracellular Ca2+ release. These factors were investigated in contrast media-induced renal vas...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(96)80298-4

    authors: Drescher P,Rauch D,Madsen PO

    更新日期:1996-11-01 00:00:00

  • Characterization of texture features of bladder carcinoma and the bladder wall on MRI: initial experience.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine textural features that show a significant difference between carcinomatous tissue and the bladder wall on magnetic resonance imaging (MRI) and explore the feasibility of using them to differentiate malignancy from the normal bladder wall as an initial ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2013.03.011

    authors: Shi Z,Yang Z,Zhang G,Cui G,Xiong X,Liang Z,Lu H

    更新日期:2013-08-01 00:00:00

  • Computer-assisted detection of subcutaneous melanomas: feasibility assessment.

    abstract:RATIONALE AND OBJECTIVES:Subcutaneous melanomas may be missed on computed tomography because of their peripheral location or perceived unimportance, yet they can have clinical significance. The use of a novel computer-assisted detection scheme to locate subcutaneous melanoma lesions in body CT images was investigated. ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.01.005

    authors: Solomon J,Mavinkurve S,Cox D,Summers RM

    更新日期:2004-06-01 00:00:00

  • Ultrasound monitoring of experimental ethanol injection into pig liver.

    abstract:RATIONALE AND OBJECTIVES:In percutaneous ethanol injection therapy, uncontrolled spread of ethanol sometimes causes complications. This study tested the accuracy of ultrasonography in showing the spread of ethanol during injection in normal postmortem pig livers. METHODS:Methylene blue-stained 96% (vol) ethanol (0.5-2...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80778-0

    authors: Tapani E,Vehmas T,Taavitsainen M

    更新日期:1994-09-01 00:00:00

  • CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). MATERIALS AND METHODS:A total of 480 pati...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.07.018

    authors: Zhao YX,Zuo ZW,Suo HN,Wang JN,Chang J

    更新日期:2016-12-01 00:00:00

  • Radiology residency eCurriculum developed in-house: evaluation of benefits and weaknesses.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to evaluate residents' use of a radiology curriculum CD-ROM designed to provide ready access to the department's curricula, study materials, and Internet resources. MATERIALS AND METHODS:A survey questionnaire eliciting feedback about the usability and value of th...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80085-5

    authors: Bartlett ES,Maley JE,Fajardo LL

    更新日期:2003-06-01 00:00:00

  • Clinical Decision Support at the Point-of-Order Entry: An Education Simulation Pilot with Medical Students.

    abstract:RATIONALE AND OBJECTIVES:We have been called to reform radiology undergraduate medical education (UME) curricula. Clinically available clinical decision support provides an opportunity to improve education regarding appropriate imaging utilization, patient safety, and cost-effective care. MATERIAL AND METHODS:We creat...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.01.020

    authors: Willis MH,Frigini LA,Lin J,Wynne DM,Sepulveda KA

    更新日期:2016-10-01 00:00:00

  • Acoustic noise transfer function in clinical MRI a multicenter analysis.

    abstract:RATIONALE AND OBJECTIVES:Acoustic noise both in terms of its magnitude and frequency during magnetic resonance imaging (MRI) scan is influenced by imaging parameters and pulse sequences. It varies because of many different factors such as structure, materials, and magnetic field strength. The purpose of our study is to...

    journal_title:Academic radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.acra.2010.09.009

    authors: Hamaguchi T,Miyati T,Ohno N,Hirano M,Hayashi N,Gabata T,Matsui O,Matsushita T,Yamamoto T,Fujiwara Y,Kimura H,Takeda H,Takehara Y

    更新日期:2011-01-01 00:00:00

  • Simulation of mammographic lesions.

    abstract:RATIONALE AND OBJECTIVES:This study presents a method for generating breast masses and microcalcifications in mammography via simulation. This simulation method allows for the creation of large image datasets with particular lesions, which may serve as a useful tool for perception studies measuring imaging system perfo...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.03.015

    authors: Saunders R,Samei E,Baker J,Delong D

    更新日期:2006-07-01 00:00:00

  • Subtraction CT angiography of the lower extremities: single volume subtraction versus multi-segmented volume subtraction.

    abstract:RATIONALE AND OBJECTIVES:To validate the hypothesis that a multisegmented approach during subtraction computed tomography (CT) angiography of the lower extremities can improve bone removal efficiency by suppressing regional motion. MATERIALS AND METHODS:The institutional review board of our hospital approved this retr...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.01.024

    authors: Lee IJ,Chung JW,Hong H,Yin YH,Kim S,Park EA,Lee W

    更新日期:2011-07-01 00:00:00

  • Estimation of volumes of distribution and intratumoral ethanol concentrations by computed tomography scanning after percutaneous ethanol injection.

    abstract:RATIONALE AND OBJECTIVES:We developed a technique for estimating the volumes of distribution and intratumoral ethanol concentrations using computed tomography (CT) scanning in patients undergoing percutaneous ethanol injection (PEI) treatment of malignant hepatic tumors. METHODS:A phantom containing anhydrous ethanol ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(96)80333-3

    authors: Alexander DG,Unger EC,Seeger SJ,Karmann S,Krupinski EA

    更新日期:1996-01-01 00:00:00

  • Impact of the Armed Forces Institute of Pathology Radiologic Pathology Course on radiology resident performance on the ACR In-Training and ABR written Examinations. American College of Radiology. American Board of Radiology.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to assess resident scores on the American College of Radiology (ACR) In-Training Examination and on the written American Board of Radiology (ABR) Examination relative to attendance at and timing of the Armed Forces Institute of Pathology (AFIP) Radiologic Pathology...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(00)80525-5

    authors: Wise SW,Mauger DT,Matthews AE,Hartman DS

    更新日期:2000-09-01 00:00:00

  • Healthy aging: an automatic analysis of global and regional morphological alterations of human brain.

    abstract:RATIONALE AND OBJECTIVES:Morphologic changes of the human brain during healthy aging provide useful reference knowledge for age-related brain disorders. The aim of this study was to explore age-related global and regional morphological changes of healthy adult brains. MATERIALS AND METHODS:T1-weighted magnetic resonan...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.03.006

    authors: Long X,Liao W,Jiang C,Liang D,Qiu B,Zhang L

    更新日期:2012-07-01 00:00:00

  • Use of 3D Printed Models to Create Molds for Shaping Implants for Surgical Repair of Orbital Fractures.

    abstract:RATIONALE AND OBJECTIVES:Surgical repair of an isolated orbital fracture requires anatomically accurate implant shape and placement. We describe a three-dimensional (3D) printing technique to customize the shape of commercially available absorbable implants. MATERIALS AND METHODS:We reviewed our early experience with ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.06.023

    authors: Weadock WJ,Heisel CJ,Kahana A,Kim J

    更新日期:2020-04-01 00:00:00

  • Performance of Diffusion Kurtosis Imaging Versus Diffusion Tensor Imaging in Discriminating Between Benign Tissue, Low and High Gleason Grade Prostate Cancer.

    abstract:RATIONALE AND OBJECTIVES:To investigate the performance of diffusion kurtosis imaging (DKI) and diffusion tensor imaging (DTI) in discriminating benign tissue, low- and high-grade prostate adenocarcinoma (PCa). MATERIALS AND METHODS:Forty-eight patients with biopsy-proven PCa of different Gleason grade (GG), who provi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.11.015

    authors: Di Trani MG,Nezzo M,Caporale AS,De Feo R,Miano R,Mauriello A,Bove P,Manenti G,Capuani S

    更新日期:2019-10-01 00:00:00

  • Three-dimensional isotropic wavelets for post-acquisitional extraction of latent images of atherosclerotic plaque components from micro-computed tomography of human coronary arteries.

    abstract:RATIONALE AND OBJECTIVES:The capability of wavelet transforms to separate signals into frequency bands is the basis for its use in image compression and storage, data management and transmission, and, recently, extraction of latent images of tissue components from noisy medical images. Analysis of temporal variations o...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.06.018

    authors: Gertz SD,Bodmann BG,Vela D,Papadakis M,Aboshady I,Cherukuri P,Alexander S,Kouri DJ,Baid S,Gittens AA,Gladish GW,Conyers JL,Cody DD,Gavish L,Mazraeshahi RM,Wilner WT,Frazier L,Madjid M,Zarrabi A,Lukovenkov S,Ahmed

    更新日期:2007-12-01 00:00:00

  • Do telephone call interruptions have an impact on radiology resident diagnostic accuracy?

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to measure the effect of distractions, in the form of telephone call interruptions, on radiology resident diagnostic accuracy. MATERIALS AND METHODS:Radiology resident discrepancy reports and reading room telephone logs at an academic tertiary care pediatric hospi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.08.001

    authors: Balint BJ,Steenburg SD,Lin H,Shen C,Steele JL,Gunderman RB

    更新日期:2014-12-01 00:00:00

  • Correlation of HER-2/neu overexpression with mammography and age distribution in primary breast carcinomas.

    abstract:RATIONALE AND OBJECTIVES:HER-2/neu is a valuable prognostic and therapeutic marker in primary breast carcinoma. The objective of this study was to determine the mammographic and patient characteristics (age) that correlate with HER-2/neu overexpression in primary breast carcinoma. MATERIALS AND METHODS:HER-2/neu chara...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.06.015

    authors: Seo BK,Pisano ED,Kuzimak CM,Koomen M,Pavic D,Lee Y,Cole EB,Lee J

    更新日期:2006-10-01 00:00:00

  • Management of Splenic Trauma in Contemporary Clinical Practice: A National Trauma Data Bank Study.

    abstract:BACKGROUND:To evaluate the utilization and efficacy of various treatments for management of adult patients with splenic trauma, highlighting the evolving role of splenic artery embolization. MATERIALS AND METHODS:The National Trauma Data Bank (NTDB) was queried for patients who sustained splenic trauma between 2007 an...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.11.010

    authors: Chahine AH,Gilyard S,Hanna TN,Fan S,Risk B,Johnson JO,Duszak R Jr,Newsome J,Xing M,Kokabi N

    更新日期:2020-12-04 00:00:00

  • Comparison between acetazolamide challenge and 10% carbon dioxide challenge perfusion CT in rat C6 glioma.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to investigate the effect of perfusion computed tomography (PCT) with acetazolamide (ACZ) challenge and compare it to 10% carbon dioxide (CO(2)) challenge in rat C6 glioma. MATERIALS AND METHODS:PCT was performed on 32 rats, including 20 with orthotopically implanted ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.09.017

    authors: Lu N,Di Y,Feng XY,Qiang JW,Zhang JW,Wang YG,Guo QY

    更新日期:2012-02-01 00:00:00

  • Influence of Cardiovascular Risk Factors on the Prevalence of Coronary Atherosclerosis in Patients with Angiographically Normal Coronary Arteries.

    abstract:RATIONALE AND OBJECTIVES:Cardiovascular (CV) disease is predominately influenced by CV risk factors and coronary computed tomography angiography (CTA) is capable of detecting early-stage coronary artery disease. We sought to determine the influence of CV risk factors on the prevalence of nonobstructive atherosclerosis ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.005

    authors: Bittner DO,Klinghammer L,Marwan M,Schmid J,Layritz C,Hoffmann U,Achenbach S,Pflederer T

    更新日期:2017-05-01 00:00:00