Do telephone call interruptions have an impact on radiology resident diagnostic accuracy?

Abstract:

RATIONALE AND OBJECTIVES:The purpose of this study was to measure the effect of distractions, in the form of telephone call interruptions, on radiology resident diagnostic accuracy. MATERIALS AND METHODS:Radiology resident discrepancy reports and reading room telephone logs at an academic tertiary care pediatric hospital were collected over a 13-month period. Phone call times and durations were recorded. Major discrepancy shifts (defined as a call shift where at least one major discrepancy was discovered the following morning by the attending radiologist between the resident preliminary and attending final reports), and dictation time stamps for each discrepant preliminary dictation were also recorded. Telephone call volume and preliminary report time stamps were compared between "discrepancy shifts" and "no discrepancy shifts." RESULTS:Each call shift spanned 14 hours, during which one radiology resident was responsible for the generation of preliminary interpretations. Review of the discrepancy log data revealed 51 major discrepancies in 41 shifts, of which 39 discrepancies had documented error details and resident preliminary report time stamps. The average number of telephone calls for the "discrepancy shifts" was slightly greater than the "no discrepancy shifts" (48.59 vs. 44.02) but was not statistically significant (P = .0575). However, there was a statistically significant increase in the average number of phone calls in the 1 hour preceding the generation of a discrepant preliminary report versus the "no discrepancy shifts" (4.23 vs. 3.24 calls, P = .027). One additional phone call during the hour preceding the generation of a discrepant preliminary report resulted in a 12% increased likelihood of a resident error (P = .017). CONCLUSIONS:Distractions in the form of telephone call interruptions may negatively impact on-call radiology resident diagnostic accuracy. Efforts should be made to limit distractions in the reading room.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Balint BJ,Steenburg SD,Lin H,Shen C,Steele JL,Gunderman RB

doi

10.1016/j.acra.2014.08.001

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

1623-8

issue

12

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(14)00307-9

journal_volume

21

pub_type

杂志文章
  • Suspicious axillary lymph nodes identified on clinical breast MRI in patients newly diagnosed with breast cancer: can quantitative features improve discrimination of malignant from benign?

    abstract:RATIONALE AND OBJECTIVES:To determine whether quantitative dynamic contrast-enhanced (DCE) and diffusion-weighted (DW) magnetic resonance imaging (MRI) features can discriminate malignant from benign axillary lymph nodes (ALNs) identified as suspicious on clinical breast MRI in patients newly diagnosed with breast canc...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.10.010

    authors: Rahbar H,Conlin JL,Parsian S,DeMartini WB,Peacock S,Lehman CD,Partridge SC

    更新日期:2015-04-01 00:00:00

  • Inflammatory breast carcinoma in magnetic resonance imaging: a comparison with locally advanced breast cancer.

    abstract:RATIONALE AND OBJECTIVES:Although inflammatory breast carcinoma (IBC) accounts for 1%-4% of all breast cancer cases, the appearance of this highly malignant tumor in magnetic resonance imaging (MRI) is still not well characterized. The aim of this study was to identify typical imaging features of IBC in comparison with...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.09.011

    authors: Renz DM,Baltzer PA,Böttcher J,Thaher F,Gajda M,Camara O,Runnebaum IB,Kaiser WA

    更新日期:2008-02-01 00:00:00

  • In vivo proton magnetic resonance spectroscopy of hepatic ischemia/reperfusion injury in an experimental model.

    abstract:RATIONALE AND OBJECTIVES:Hepatic ischemia/reperfusion injury (IRI) occurs during certain hepatobiliary surgeries, hemorrhagic shock, and veno-occlusive disease. Biochemical changes caused by hepatic IRI lead to hepatocellular remodeling, including cellular regeneration or irreversible apoptosis. This study aims to char...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.09.019

    authors: Chow AM,Chan KW,Fan SJ,Yang J,Cheung JS,Khong PL,Wu EX

    更新日期:2011-02-01 00:00:00

  • Optimizing image contrast display improves quantitative stenosis measurement in heavily calcified coronary arterial segments on coronary CT angiography: A proof-of-concept and comparison to quantitative invasive coronary angiography.

    abstract:RATIONALE AND OBJECTIVES:Blooming artifact from calcified plaques often renders measurement of stenosis impossible on coronary computed tomographic angiography (CTA). We sought to evaluate the impact of modifying window level on reducing blooming artifact, and its impact on stenosis quantification. MATERIALS AND METHO...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.02.016

    authors: Shmilovich H,Cheng VY,Dey D,Rajani R,Nakazato R,Otaki Y,Nakanishi R,Vashistha V,Min JK,Berman DS

    更新日期:2014-06-01 00:00:00

  • How Well Does Dual-energy CT with Fast Kilovoltage Switching Quantify CT Number and Iodine and Calcium Concentrations?

    abstract:RATIONALE AND OBJECTIVES:Because it is imperative for understanding the performance of dual-energy computed tomography scanner to determine clinical diagnosis, we aimed to assess the accuracy of quantitative measurements using dual-energy computed tomography with fast kilovoltage switching. MATERIALS AND METHODS:Quant...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.11.002

    authors: Ohira S,Karino T,Ueda Y,Nitta Y,Kanayama N,Miyazaki M,Koizumi M,Teshima T

    更新日期:2018-04-01 00:00:00

  • Corona Virus International Public Health Emergencies: Implications for Radiology Management.

    abstract::The outbreak of 2019 novel coronavirus (2019-nCoV) pneumonia was reported in Wuhan, Hubei Province, China in December 2019 and has spread internationally. This article discusses how radiology departments can most effectively respond to this public health emergency. ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.02.003

    authors: Zhang HW,Yu J,Xu HJ,Lei Y,Pu ZH,Dai WC,Lin F,Wang YL,Wu XL,Liu LH,Li M,Mo YQ,Zhang H,Luo SP,Chen H,Lyu GW,Zhou ZG,Liu WM,Liu XL,Song HY,Chen FZ,Zeng L,Zhong H,Guo TT,Hu YQ,Yang XX,Liu PN,Li DF

    更新日期:2020-04-01 00:00:00

  • View box luminance measurements and their effect on reader performance.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to investigate the importance of view box luminance and viewing conditions on low-contrast detection by readers. MATERIALS AND METHODS:Radiographs of a mammographic contrast-detail phantom were examined on 632 view box panels. The luminance of these panels was obt...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(99)80429-2

    authors: Rill LN,Huda W,Gkanatsios NA

    更新日期:1999-09-01 00:00:00

  • Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses.

    abstract:RATIONALE AND OBJECTIVES:To assess the performance of dual-energy computed tomography (DECT) equipped with the new tin filter technology to classify phantom renal lesions as cysts or enhancing masses. MATERIALS AND METHODS:Forty spherical lesion proxies ranging in diameter from 6 to 27 mm were filled with either disti...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.11.007

    authors: Leschka S,Stolzmann P,Baumüller S,Scheffel H,Desbiolles L,Schmid B,Marincek B,Alkadhi H

    更新日期:2010-04-01 00:00:00

  • Ex Vivo Study of Artifacts Caused by Breast Tissue Markers with Different 1.5 Tesla and 3 Tesla MRI Scanners - A Bicentric Study.

    abstract:RATIONALE AND OBJECTIVES:The purpose of our study was to evaluate magnetic resonance (MR) artifacts related to breast tissue markers in breast imaging procedures. MATERIALS AND METHODS:In this bicentric prospective ex vivo study 10 different commercially available markers were measured in self-made breast phantoms. Br...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.12.006

    authors: Puesken M,Unterberg-Buchwald C,Rhiem K,Große Hokamp N,Maintz D,Lotz J,Wienbeck S

    更新日期:2021-01-01 00:00:00

  • Pitfalls in RECIST Data Extraction for Clinical Trials: Beyond the Basics.

    abstract::Response Evaluation Criteria in Solid Tumors (RECIST) is a standardized methodology for determining therapeutic response to anticancer therapy using changes in lesion appearance on imaging studies. Many radiologists are now using RECIST in their routine clinical workflow, as part of consultative arrangements, or withi...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2015.01.015

    authors: Abramson RG,McGhee CR,Lakomkin N,Arteaga CL

    更新日期:2015-06-01 00:00:00

  • Intrathoracic tracheal volume and collapsibility on inspiratory and end-expiratory ct scans correlations with lung volume and pulmonary function in 85 smokers.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the correlations of tracheal volume and collapsibility on inspiratory and end-expiratory computed tomography (CT) with lung volume and with lung function in smokers. MATERIALS AND METHODS:The institutional review board approved this study at each institution. 85 smokers (mean age 6...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.11.005

    authors: Yamashiro T,San José Estépar R,Matsuoka S,Bartholmai BJ,Ross JC,Diaz A,Murayama S,Silverman EK,Hatabu H,Washko GR

    更新日期:2011-03-01 00:00:00

  • Evaluation of the quality of radiology requisitions for intensive care unit patients.

    abstract:RATIONALE AND OBJECTIVES:The study aim is to evaluate the quality of radiology requisitions for plain film radiographs on intensive care unit (ICU) patients. MATERIALS AND METHODS:Radiology requisitions for 58 patients in ICU units at our children's hospital and the corresponding original orders for the study, written...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.10.017

    authors: Cohen MD,Curtin S,Lee R

    更新日期:2006-02-01 00:00:00

  • Preoperative Prediction of Axillary Lymph Node Metastasis in Breast Carcinoma Using Radiomics Features Based on the Fat-Suppressed T2 Sequence.

    abstract:RATIONALE AND OBJECTIVES:To investigate the value of radiomics method based on the fat-suppressed T2 sequence for preoperative predicting axillary lymph node (ALN) metastasis in breast carcinoma. MATERIALS AND METHODS:The data of 329 invasive breast cancer patients were divided into the primary cohort (n = 269) and va...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.11.004

    authors: Tan H,Gan F,Wu Y,Zhou J,Tian J,Lin Y,Wang M

    更新日期:2020-09-01 00:00:00

  • Pseudostenosis in vessels adjacent to intracranial aneurysms on volume-rendered 3D angiograms: a phantom study.

    abstract:RATIONALE AND OBJECTIVE:Among artifacts on three-dimensional (3D) angiograms, pseudostenosis in vessels adjacent to intracranial aneurysms has not been described. By using a phantom, artifacts seen in vessels adjacent to intracranial aneurysms on volume-rendered 3D angiograms were assessed. MATERIALS AND METHODS:Using...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.12.003

    authors: Yamura M,Hirai T,Korogi Y,Ikushima I,Yamashita Y,Oishi S

    更新日期:2005-03-01 00:00:00

  • Intraluminal air within an obstructed appendix: a CT sign of perforated or necrotic appendicitis.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to evaluate the predictive value of intraluminal air for appendiceal necrosis and/or perforation when not apparent on imaging. Additional factors of intraluminal appendicoliths, age, and gender were also assessed. MATERIALS AND METHODS:Patients with pathologically pro...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.04.018

    authors: Azok JT,Kim DH,Munoz Del Rio A,Sonavane SK,Bhalla S,Anaya-Baez V,Menias CO

    更新日期:2012-10-01 00:00:00

  • When and why might a computer-aided detection (CAD) system interfere with visual search? An eye-tracking study.

    abstract:RATIONAL AND OBJECTIVES:Computer-aided detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. METHODS:Forty-seven naive observers in two studies were asked to ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.05.013

    authors: Drew T,Cunningham C,Wolfe JM

    更新日期:2012-10-01 00:00:00

  • Local toxicity of hepatic arterial infusion of hexokinase II inhibitor, 3-bromopyruvate: In vivo investigation in normal rabbit model.

    abstract:RATIONALE AND OBJECTIVES:3-Bromopyruvate (3-BrPA), an hexokinase II inhibitor, is known to have high necrotic rate in hyperglycolytic liver tumor models without apparent damage to the normal liver parenchyma. The toxicity of intra-arterial delivery of 3-BrPA in various concentrations has not been specifically investiga...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.09.059

    authors: Chang JM,Chung JW,Jae HJ,Eh H,Son KR,Lee KC,Park JH

    更新日期:2007-01-01 00:00:00

  • Deep Learning in the Prediction of Ischaemic Stroke Thrombolysis Functional Outcomes: A Pilot Study.

    abstract:RATIONALE AND OBJECTIVES:Intravenous thrombolysis decision-making and obtaining of consent would be assisted by an individualized risk-benefit ratio. Deep learning (DL) models may be able to assist with this patient selection. MATERIALS AND METHODS:Clinical data regarding consecutive patients who received intravenous ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.03.015

    authors: Bacchi S,Zerner T,Oakden-Rayner L,Kleinig T,Patel S,Jannes J

    更新日期:2020-02-01 00:00:00

  • Sonographic evaluation of orthotopic bladder tumors in mice treated with TNP-470, an angiogenic inhibitor.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the feasibility of using transabdominal ultrasonography (US) to monitor tumor growth and response to therapy in a mouse model of orthotopic bladder carcinoma. MATERIALS AND METHODS:Human bladder carcinoma cell suspensions were injected into the bladde...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(01)90038-8

    authors: Rooks V,Beecken WD,Iordanescu I,Taylor GA

    更新日期:2001-02-01 00:00:00

  • A text-to-speech converter for radiology journal articles.

    abstract::Radiology articles are primarily designed to be read on paper or a screen. Audio versions let users hear this material during activities when reading is not practical. Currently, there are relatively few radiology materials in audio format. However, inexpensive text-to-speech software can easily produce spoken-word ve...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.06.020

    authors: Richardson ML

    更新日期:2010-12-01 00:00:00

  • New assistive devices for MR-guided microwave thermocoagulation of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to develop and test new assistive devices to aid in the performance of safe, easy, and accurate microwave thermocoagulation therapy guided by magnetic resonance (MR) imaging. MATERIALS AND METHODS:An open-configuration MR imager with an optical tracking system for...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80043-0

    authors: Morikawa S,Inubushi T,Kurumi Y,Naka S,Sato K,Tani T,Haque HA,Tokuda J,Hata N

    更新日期:2003-02-01 00:00:00

  • Magnetic resonance imaging using hyperpolarized 3He-Gas.

    abstract:RATIONALE AND OBJECTIVES:Current imaging procedures of the lung concentrate on visualization of morphology. Computed tomography is the imaging method of choice for the majority of pulmonary diseases. Functional data are commonly obtained from arterial blood gas analysis, spirometry, and body plethysmography, which all ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)00335-0

    authors: Gast KK,Eberle B,Schmiedeskamp J,Kauczor HU

    更新日期:2003-10-01 00:00:00

  • Discriminating Depth of Response to Therapy in Multiple Myeloma Using Whole-body Diffusion-weighted MRI with Apparent Diffusion Coefficient: Preliminary Results From a Single-center Study.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to measure apparent diffusion coefficient (ADC) in Chinese patients with newly diagnosed multiple myeloma by whole-body diffusion-weighted magnetic resonance imaging (WB-DWI MRI) and assess the diagnostic accuracy of ADC in the discrimination of deep response to induction chemo...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.008

    authors: Wu C,Huang J,Xu WB,Guan YJ,Ling HW,Mi JQ,Yan H

    更新日期:2018-07-01 00:00:00

  • Low-dose unenhanced CT for IV contrast bolus timing: is it reliable to assess hepatic steatosis?

    abstract:RATIONALE AND OBJECTIVES:To determine whether an unenhanced low-dose image acquired during automated contrast bolus timing can be used to assess hepatic steatosis. MATERIALS AND METHODS:Fifty subjects (29 male, 21 female; 26-92 years; mean body mass index (BMI; 26.9) with abdominal multiphasic computed tomography were...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.013

    authors: Husarik DB,Boll DT,Nelson RC,Merkle EM

    更新日期:2011-07-01 00:00:00

  • Comparison of three methods for estimating the standard error of the area under the curve in ROC analysis of quantitative data.

    abstract:RATIONALE AND OBJECTIVES:Several methods have been proposed for estimating the standard error (SE) of the area under the curve (AUC) in receiver operating characteristic analysis. The authors examined the validity of three methods--the LABROC procedure, exponential approximation, and the method of DeLong et al (purely ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80561-5

    authors: Hajian-Tilaki KO,Hanley JA

    更新日期:2002-11-01 00:00:00

  • Effect of radiologic contrast media on cell volume regulation in rabbit proximal renal tubules.

    abstract:RATIONALE AND OBJECTIVES:Most radiographic contrast media are hyperosmotic and able to shrink cells with which they are in contact. The authors studied cell volume control in rabbit proximal renal tubules after incubation with three contrast media: iohexol, ioxaglate, and iodixanol. MATERIALS AND METHODS:Proximal rena...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(03)80547-0

    authors: Galtung HK,Løken M,Sakariassen KS

    更新日期:2001-05-01 00:00:00

  • Computer-assisted detection of subcutaneous melanomas: feasibility assessment.

    abstract:RATIONALE AND OBJECTIVES:Subcutaneous melanomas may be missed on computed tomography because of their peripheral location or perceived unimportance, yet they can have clinical significance. The use of a novel computer-assisted detection scheme to locate subcutaneous melanoma lesions in body CT images was investigated. ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.01.005

    authors: Solomon J,Mavinkurve S,Cox D,Summers RM

    更新日期:2004-06-01 00:00:00

  • Reinventing the apprenticeship: the hot seat in the digital era.

    abstract:RATIONALE AND OBJECTIVES:Describe new interactive digital teaching methods for medical student education in radiology and evaluate student responses. MATERIALS AND METHODS:Third- and fourth-year medical students on radiology clerkship were taught using either film-based "hot seat" format, digital "hot seat," or didact...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.07.017

    authors: Su TJ,Shaffer K

    更新日期:2004-11-01 00:00:00

  • Is an ROC-type response truly always better than a binary response in observer performance studies?

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to assess similarities and differences between methods of performance comparisons under binary (yes or no) and receiver-operating characteristic (ROC)-type pseudocontinuous (0-100) rating data ascertained during an observer performance study of interpretation of full-f...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.12.012

    authors: Gur D,Bandos AI,Rockette HE,Zuley ML,Hakim CM,Chough DM,Ganott MA,Sumkin JH

    更新日期:2010-05-01 00:00:00

  • Multidisciplinary gastrointestinal cancer clinic: abdominal radiologist as active participant.

    abstract:RATIONALE AND OBJECTIVES:Abdominal radiologists actively participated and provided subspecialty radiologic expertise in a multidisciplinary gastrointestinal cancer clinic that served a tertiary referral center. The purpose of this study was to evaluate the feasibility and nonradiologists' opinions of this new approach ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(98)80564-3

    authors: Silverman SG,Khorasani R,Adams DF,Phillips MD,Sica GT,Mayer RJ

    更新日期:1998-10-01 00:00:00