Abstract:
:The aim of the study was to compare experimentally conduction velocity (CV) estimates obtained with different estimation methods based on surface electromyogram (EMG) signals detected using five spatial filters. The filters investigated were the longitudinal single and double differential, transverse single and double differential, and normal double differential. The same surface EMG signals detected as described in Part 1 were used in this work. CV was estimated with four commonly used delay estimation techniques, i.e. from the distance between the peak values of two waveforms (with and without polynomial interpolation around the peak), and by the maximum likelihood estimate (MLE) based on two or more surface EMG channels. The average standard deviation of CV estimation (for all the MUs and the two muscles together) was 0.61 m s(-1) and 0.79 m s(-1) for the peak method, with and without interpolation, respectively, and 0.50 m s(-1) and 0.31 m s(-1) for the MLE method, from two and more surface EMG channels, respectively. Moreover, the mean of CV estimates varied by as much as 1 m s(-1) depending on the spatial filter used and the method adopted for CV estimation. Considering the dependence on the spatial filter only, the average (over all estimation methods) CV estimates obtained with the five spatial filters were 4.32 m s(-1) (normal double differential), 4.23 m s(-1) (longitudinal double differential), 4.61 m s(-1) (transverse double differential), 4.64 m s(-1) (transverse single differential) and 4.03 m s(-1) (longitudinal single differential). It was concluded that the comparison of single MU CV values obtained in different studies is critical if different spatial filters and processing techniques are used for their estimation. Higher estimates of CV were attributed to a smaller reduction in non-travelling signal components and thus were assumed to be positively biased.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Schulte E,Farina D,Rau G,Merletti R,Disselhorst-Klug Cdoi
10.1007/BF02348440keywords:
subject
Has Abstractpub_date
2003-05-01 00:00:00pages
338-45issue
3eissn
0140-0118issn
1741-0444journal_volume
41pub_type
杂志文章abstract::One challenge in the current research of brain-computer interfaces (BCIs) is how to classify time-varying electroencephalographic (EEG) signals as accurately as possible. In this paper, we address this problem from the aspect of updating feature extractors and propose an adaptive feature extractor, namely adaptive com...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0107-4
更新日期:2006-10-01 00:00:00
abstract::A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectroni...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0224-8
更新日期:2007-10-01 00:00:00
abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351008
更新日期:2004-01-01 00:00:00
abstract::The aim of the study is to establish the validity of the use of the electrical impedance technique for estimating local oedema in extremities through comparison with computed-tomography (CT) analysis. Eight healthy women (group 1) and nine women with unilateral leg oedema following chronic lymphatic obstruction (group...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522859
更新日期:1998-01-01 00:00:00
abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02277-8
更新日期:2021-01-01 00:00:00
abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446654
更新日期:1993-07-01 00:00:00
abstract::OKAS-3D is a further development of the single floating circle target tracker. This tracker consists of a cathode ray tube display, a lens in front of the display and a circular light-sensitive photocell placed in the image field of the lens. A small circular trace generated on the screen is focused around the photoce...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510786
更新日期:1995-09-01 00:00:00
abstract::Determination of the adequacy of dialysis is a routine but crucial procedure in patient evaluation. The total dialysis dose, expressed as Kt/V, has been widely recognised to be a major determinant of morbidity and mortality in haemodialysed patients. Many different factors influence the correct determination of Kt/V, ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348080
更新日期:2003-07-01 00:00:00
abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1374-8
更新日期:2016-05-01 00:00:00
abstract::A three-layer Newtonian model is investigated using a combined Eulerian-Lagrangian computational method to describe the dynamic behaviour of leukocytes. The model, composed of a cell membrane (outer layer), cytoplasm (middle layer) and nucleus (inner layer), can better describe the recovery characteristics because lar...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510753
更新日期:1998-03-01 00:00:00
abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441486
更新日期:1989-05-01 00:00:00
abstract::Protein glycosylation is one of the most important and complex post-translational modification that provides greater proteomic diversity than any other post-translational modification. Fast and reliable computational methods to identify glycosylation sites are in great demand. Two key issues, feature encoding and feat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1268-9
更新日期:2015-06-01 00:00:00
abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345312
更新日期:2003-09-01 00:00:00
abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-007-0264-0
更新日期:2007-12-01 00:00:00
abstract::The effectiveness of electrochemotherapy, a local treatment using electric pulses to increase the uptake of chemotherapeutic drug, includes several antitumor mechanisms. In addition to the cytotoxic action of chemotherapeutic drug, treatment outcome also depends on antitumor immune response. In order to assess the con...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1562-1
更新日期:2017-07-01 00:00:00
abstract::In this study, we propose an integrated tooth segmentation and gingival tissue deformation simulation framework used to design and evaluate the orthodontic treatment plan especially with invisible aligners. Firstly, the bio-characteristics information of the digital impression is analyzed quantitatively and demonstrat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02230-9
更新日期:2020-10-01 00:00:00
abstract::An algorithm for determining the frequency and propagation time of the gastric slow wave has been designed for integration into a demand gastric pacing system. The algorithm analyses the serosal activity in both the time and frequency domains, and the results are compared to produce a conclusion only when the values a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344688
更新日期:2000-01-01 00:00:00
abstract::Performance evaluations of ion-selective field-effect transistors (ISFETs) have been carried out using both quality-control materials and whole arterial blood samples. Comparison of the results from these evaluations suggests that the whole blood evaluation may be more useful when assessing the value of particular sen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442678
更新日期:1990-05-01 00:00:00
abstract::The starting point of this paper is the analysis of the reference problem in intra-cerebral electroencephalographic (iEEG) recordings. It is well accepted that both surface and depth EEG signals are always recorded with respect to some unknown time-varying signal called reference. This article discusses different meth...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0946-0
更新日期:2012-10-01 00:00:00
abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441487
更新日期:1989-05-01 00:00:00
abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0716-9
更新日期:2011-01-01 00:00:00
abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02262-1
更新日期:2020-11-01 00:00:00
abstract::Dynamic methods in the spectral domain are necessary to analyse biological signals because of the frequently nonstationary character of the signals. The paper presents an adaptive procedure of fitting time-dependent ARMA models to nonstationary signals, which is suitable for on-line calculations. The properties of the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510536
更新日期:1995-05-01 00:00:00
abstract::Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02088-6
更新日期:2020-02-01 00:00:00
abstract::This article presents a novel approach of edged and edgeless object-shape recognition and 3D reconstruction from gradient-based analysis of tactile images. We recognize an object's shape by visualizing a surface topology in our mind while grasping the object in our palm and also taking help from our past experience of...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1142-1
更新日期:2014-04-01 00:00:00
abstract::The clinical efficacy of a microwave (MW) hyperthermia system using an electric-field converging (lens) applicator is evaluated for 42 malignant tumours with a maximum tumour depth of less than 7 cm. The mean of the maximum, average and minimum tumour temperature of the 42 tumours are 44.5, 42.5 and 40.7 C, respective...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02522944
更新日期:1995-01-01 00:00:00
abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02518872
更新日期:1998-11-01 00:00:00
abstract::The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMG(MIC)) and an accelerometer (MMG(ACC)) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/s11517-006-0036-2
更新日期:2006-04-01 00:00:00
abstract::Stiffness of the arterial wall and atherosclerotic plaque components is a determinant of the stress field within plaques, which has been suggested to be an indicator of plaque vulnerability. The diversity and inhomogeneous structure of atherosclerotic lesions complicate the characterization of plaque components. In th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1910-4
更新日期:2019-03-01 00:00:00
abstract::The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0552-y
更新日期:2010-01-01 00:00:00