Abstract:
:The consequences of a diagnosis of occupational contact dermatitis (OCD) were investigated using cases available from the voluntary surveillance scheme, EPIDERM. Cases of OCD reported from November 1994 to September 1995 were identified and sampled to give at least 100 cases of allergic, irritant and mixed OCD reported by consultant dermatologists (344 cases) and occupational physicians (377 cases). A questionnaire was sent to the reporting physician to elicit further information. 512 completed questionnaires were returned, of which 510 were eligible for analysis. Among cases reported by dermatologists (n = 286) and occupational physicians (n = 224), 7% (6.3%) had been unemployed and 16.8% (20.1%) had taken sick leave. 3 factors independently predicted time off work in a logistic regression analysis: age OR = 1.25 (95% CI, 1.05-1.49), allergic dermatitis OR = 1.77 (95% CI, 1.13-2.79) and medicolegal assessment OR = 4.42 (95% CI, 2.20-8.89). Overall, 15.7% did not improve clinically between the first and last visit. Those who did not improve had been exposed to the agent for longer (mean 7.6 years) than those who did (5.3 years) (p = 0.09). In patients journal_name journal_title authors doi keywords: subject pub_date pages issue eissn issn pii journal_volume pub_type
abstract::Methods for investigating contact eczematous patients and for measuring the sensitizing potential of various substances are well known and in general, sufficiently effective. This is not true for irritant dermatitis, or for possible (skin) irritant substances; moreover, cosmetics commonly do not contain acutely harmfu...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1975.tb05305.x
更新日期:1975-01-01 00:00:00
abstract::Risk factors for cement eczema were studied among workers employed in the Danish construction industry. 2 cohorts exposed to cement containing different concentrations of water-soluble chromate were examined. A statistically significant decrease in the number of workers with allergic cement eczema was found in the coh...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1991.tb01793.x
更新日期:1991-08-01 00:00:00
abstract::A sugar refinery worker developed allergic contact dermatitis of his feet secondary to rubber accelerators in his work boots. The dermatitis resolved when polyvinyl chloride work boots were substituted. The importance of controlling hyperhidrosis in the management of foot dermatitis in workers is discussed. ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1979.tb04860.x
更新日期:1979-07-01 00:00:00
abstract::The clinical and patch test (PT) features of patients with positive PT reactions to fragrance mix (FM) were studied. 378 consecutive eczema outpatients patch tested with a modified European standard series were analysed. 60 patients (15.9%) reacted to FM. No significant differences could be found between the ages of F...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.0105-1873.2005.00516.x
更新日期:2005-04-01 00:00:00
abstract::Allergic contact dermatitis caused by medical devices for diabetes patients has been increasingly described in the literature in the last few years. This article reviews the cases of allergic contact dermatitis caused by insulin pumps and glucose sensors reported since the 1970s, the culprit allergen(s), the results o...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/cod.13120
更新日期:2018-12-01 00:00:00
abstract::A patient was found to have a delayed positive patch test to hydrocortisone on multiple testing. This proved to be due to a photoallergy with an action spectrum in the UV-A range. The patient coincidently had a polymorphous light eruption in the UV-B range. ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1978.tb03845.x
更新日期:1978-12-01 00:00:00
abstract::Predictive guinea pig sensitization studies have been performed with commercial and purified 1H-benzotriazole. In only 3 animals, induced and challenged according to the maximization protocol with more than 100 times the normal use concentration, were slight erythemas elicited with the commercial grade of benzotriazol...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1984.tb00024.x
更新日期:1984-03-01 00:00:00
abstract::3-Iodo-2-propynyl-butylcarbamate (IPBC) is a fungicide used in both industrial products and cosmetics. We report the first case of allergic contact dermatitis from airborne exposure to this preservative. A 34-year-old female production worker at a paint factory developed dermatitis on air-exposed skin areas. Patch tes...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1034/j.1600-0536.2003.00079.x
更新日期:2003-03-01 00:00:00
abstract::Allergic contact dermatitis affects a worrying proportion of the general population. The mechanisms underlying this chemical-triggered delayed-type hypersensitivity are still not fully understood. In recent years, basic research has shown that the immune system reacts to contact allergens by activation of signalling p...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/cod.12311
更新日期:2015-01-01 00:00:00
abstract::A 45-year-old woman developed dermatitis of the face after she applied a cosmetic package comprising day and night creams. Patch tests were performed with the British Contact Dermatitis Society (BCDS) standard, bases + preservatives, and cosmetic series in addition to samples of both creams and the individual constitu...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2007.00972.x
更新日期:2007-04-01 00:00:00
abstract::In cases of conjunctivitis associated with the use of soft lenses, delayed hypersensitivity to disinfecting components of the used soft lens liquids has to be considered. In 7/15 patients, positive patch test reactions to merthiolate, chlorhexidine or the soaking solutions were observed. The significance of these find...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1980.tb04956.x
更新日期:1980-08-01 00:00:00
abstract:BACKGROUND:Foot eczema often occurs in combination with hand eczema. However, in contrast to the situation with hand eczema, knowledge about foot eczema is scarce, especially in occupational settings. OBJECTIVE:To evaluate the prevalence of foot eczema and associated factors in patients with hand eczema taking part in...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.12370
更新日期:2015-08-01 00:00:00
abstract::Rubber chemicals are among the most common occupational contact sensitizers. The most common rubber sensitizers are thiurams, thiazoles, carbamates and paraphenylenediamine derivatives. Here we present data on a less-well-known rubber chemical, N-(cyclohexylthio)phthalimide (CTP; CAS 17796-82-6). This chemical is curr...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1996.tb02106.x
更新日期:1996-01-01 00:00:00
abstract:BACKGROUND:Allergic contact dermatitis is known to occur in children with and without atopic dermatitis, but more data are needed on contact sensitization profiles in these two groups. OBJECTIVES:To identify frequent allergens in children with and without atopic dermatitis suspected of having allergic contact dermatit...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.12711
更新日期:2017-03-01 00:00:00
abstract:BACKGROUND:There is a lack of prospective studies investigating contact sensitization in patients with chronic leg ulcers. OBJECTIVES:To determine the frequency of contact sensitization in patients with chronic leg ulcers using a special series of patch tests and to determine whether the number of sensitizations was c...
journal_title:Contact dermatitis
pub_type: 杂志文章,多中心研究
doi:10.1111/j.1600-0536.2009.01541.x
更新日期:2009-05-01 00:00:00
abstract::The occurrence of occupational contact dermatitis among workers in a rubber factory from 1976 to 1980 was studied. Insurance compensation was paid to 50 workers with dermatitis. 21 of the cases were allergic and 27 toxic contact dermatitis, giving a contact dermatitis frequency of 5.6/1000 workers. Paraphenylenediamin...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1982.tb04259.x
更新日期:1982-11-01 00:00:00
abstract::Commercial dental restorative materials were analysed in order to obtain information about the occurrence of sensitizing acrylates. Acetone-soluble methacrylates of 7 bonding materials, 8 composite resins and 2 glass ionomers were identified by gas chromatography with mass-selective detection and quantified by liquid ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.0105-1873.2004.00336.x
更新日期:2004-04-01 00:00:00
abstract::We describe the use of gas chromatography with mass spectrometry (GC-MS) in the investigation of a case of allergic contact dermatitis of the lip margins caused by a lip liner. Patch testing identified sensitization to para-tertiary-butylphenol-formaldehyde resin (PTBP-FR), a resin glue frequently used in leather work...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1993.tb03375.x
更新日期:1993-03-01 00:00:00
abstract:BACKGROUND:The proper reading of patch test (PT) reactions, based on morphological criteria, is of utmost importance. Digital images are increasingly used for medical training. OBJECTIVES:To assess the diagnostic validity of readings of 20 digital images of various PT reaction grades by congress attendants. METHODS:1...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2007.01236.x
更新日期:2007-11-01 00:00:00
abstract::We have studied a group of 104 patients with pompholyx, to investigate the relationship between allergological factors and its etiopathogenesis. The following examinations were performed: blood sampling (routine tests and IgE levels), allergological tests (patch, prick, intradermal, and oral provovation tests with nic...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1992.tb00862.x
更新日期:1992-01-01 00:00:00
abstract::Numerous studies have focused attention on the influence of various biological and environmental factors on contact hypersensitivity. In order to evaluate the persistence and/or modification of allergic contact sensitivity to a number of common contact sensitizers, the same standardized patch tests were repeated on 17...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1996.tb02222.x
更新日期:1996-05-01 00:00:00
abstract::The occurrence and causes of occupational dermatoses at a film laboratory following modernization was studied. In 1983 the film laboratory moved to new premises built to reduce exposure to hazardous chemicals. The study was carried out during 1983-1986 with repeated interviews and dermatological examinations of all em...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1989.tb04656.x
更新日期:1989-03-01 00:00:00
abstract::Sixty-six patients who had to undergo total hip replacement by means of a metal-to-plastic Stanmore prosthesis, were patch-tested prior to and 6 to 12 months after surgery with the standard ICDRG all allergens series and with acrylic monomer 5% in acetone. In 62 patients the history of metal allergy as well as the pat...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1976.tb03044.x
更新日期:1976-10-01 00:00:00
abstract::16 children with atopic dermatitis and 4 nonatopics were skin tested with flavourings and perfumes. Immediate reactions to balsam of Peru and fragrance-mix were found in 9 atopics, and none among nonatopics. An irritant is more probable than an immunologic mechanism. Allergen solutions should probably be assayed at a ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1992.tb05196.x
更新日期:1992-07-01 00:00:00
abstract::In the present study, we have investigated 42 cosmetic products based on natural ingredients for content of 11 fragrance substances: geraniol, hydroxycitronellal, eugenol, isoeugenol, cinnamic aldehyde, cinnamic alcohol, alpha-amylcinnamic aldehyde, citral, coumarin, dihydrocoumarin and alpha-hexylcinnamic aldehyde. T...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1996.tb02246.x
更新日期:1996-06-01 00:00:00
abstract::Colour developers are widely used and contact dermatitis and lichen planus-like eruptions from them are well-known. As a result of automation, there have been few recent reports of contact dermatitis from colour developers. We describe here 4 cases of dermatoses from Kodak CD4 colour developer and study their cross se...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1984.tb00147.x
更新日期:1984-05-01 00:00:00
abstract::A dermatologic investigation of 202 construction painters included patch testing with the TRUE Test standard series and ingredients of water-based paints, glues and putties (painters' series). 32 painters had current eczema and 16 had a history of previous eczema. Of these, 16 and 9, respectively, had current and prev...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1995.tb00839.x
更新日期:1995-01-01 00:00:00
abstract::Risk assessment serves to ensure that dermal exposure to skin sensitizers does not result in the acquisition of allergic skin disease. Traditionally, the approach adopted was one of comparative analysis, involving benchmarking against other allergens of known potency. More recently, efforts have been made to embrace a...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0536.2006.01082.x
更新日期:2007-06-01 00:00:00
abstract::Many factors can influence the elicitation of hypersensitivity reactions in guinea pigs and humans. The effect which the vehicle might have on the test response in guinea pigs sensitized with various acrylic compounds, using the "guinea pig maximization test", has been investigated. A marked decrease in the number of ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1984.tb01008.x
更新日期:1984-11-01 00:00:00
abstract::We showed earlier that most patients with contact dermatitis due to corticosteroids show cross-reactions when patch tested with hydrocortisone-17-butyrate (H-17-B). To test whether H-17-B could be used for detecting topical corticosteroid allergy, we screened patients undergoing routine patch testing with H-17-B. Pati...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1989.tb04729.x
更新日期:1989-09-01 00:00:00