Preventative maintenance and unscheduled downtime from an economic perspective.

Abstract:

:A spreadsheet-based model for economically characterizing the operation of a radiation treatment program has been used to perform a quantitative financial analysis of scheduled and unscheduled downtime. The incremental cost of downtime is broken down into three categories: remuneration of in-house or third party service technologists, decreased patient capacity, and local operating procedures for dealing with downtime. Different service arrangements and operating procedures are simulated to demonstrate the financial cost of treatment machine unavailability due to either preventative maintenance or unexpected breakdown. Depending on the service arrangement and operating policies for accommodating downtime, the combined cost of scheduled and unscheduled downtime (at 5%) can exceed 10% of the total cost of the radiation treatment program. It has also been demonstrated that the greatest cost component of downtime is decreased patient capacity, which can exceed $400,000 (CAN) when unscheduled downtime reaches 5%. The interpretation of this cost depends on the funding environment. Although the emphasis of this study has been the financial consequences of downtime, there are other factors which must be considered when developing policies and procedures for accommodating downtime such as effects on treatment, patient convenience and quality of life for staff. Even though the numerical results are strictly valid only within the context of the simulations performed, they do provide a broad framework within which medical physicists can make recommendations regarding service support and downtime.

journal_name

J Appl Clin Med Phys

authors

Dunscombe P,Roberts G,Valiquette L

doi

10.1120/jacmp.v1i2.2647

keywords:

subject

Has Abstract

pub_date

2000-04-01 00:00:00

pages

68-75

issue

2

issn

1526-9914

journal_volume

1

pub_type

杂志文章
  • Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy.

    abstract::MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5057

    authors: Dhanesar SK,Lim TY,Du W,Bruno TL,Frank SJ,Kudchadker RJ

    更新日期:2015-09-08 00:00:00

  • 100 days with scans of the same Catphan phantom on the same CT scanner.

    abstract::Quality control (QC) of CT scanners is important to evaluate image quality and radiation dose. Different QC phantoms for testing image quality parameters on CT are commercially available, and Catphan phantoms are widely used for this purpose. More data from measured image quality parameters on CT are necessary to asse...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12186

    authors: Husby E,Svendsen ED,Andersen HK,Martinsen ACT

    更新日期:2017-11-01 00:00:00

  • Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.

    abstract::For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dos...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5514

    authors: Liu H,Zhuang T,Stephans K,Videtic G,Raithel S,Djemil T,Xia P

    更新日期:2015-11-08 00:00:00

  • Surface and build-up dose comparison between Elekta 6 MV flattening filter and flattening-filter-free beams using an advanced Markus ionization chamber and a solid water-equivalent phantom.

    abstract::Using a plane-parallel advanced Markus ionization chamber and a stack of water-equivalent solid phantom blocks, percentage surface and build-up doses of Elekta 6 MV flattening filter (FF) and flattening-filter-free (FFF) beams were measured as a function of the phantom depth for field sizes ranging from 2 × 2 to 10 × ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13094

    authors: Imae T,Takenaka S,Watanabe Y,Aoki A,Matsuda K,Sasaki K,Saegusa S,Nawa K,Nakagawa K,Abe O

    更新日期:2020-12-01 00:00:00

  • Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators.

    abstract::Flattening filter-free (FFF) beams are becoming the preferred beam type for stereotactic radiosurgery (SRS) and stereotactic ablative radiation therapy (SABR), as they enable an increase in dose rate and a decrease in treatment time. This work assesses the effects of the flattening filter on small field output factors...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.6059

    authors: Tyler MK,Liu PZ,Lee C,McKenzie DR,Suchowerska N

    更新日期:2016-05-08 00:00:00

  • FDG PET/CT for rectal carcinoma radiotherapy treatment planning: comparison of functional volume delineation algorithms and clinical challenges.

    abstract::PET/CT imaging could improve delineation of rectal carcinoma gross tumor volume (GTV) and reduce interobserver variability. The objective of this work was to compare various functional volume delineation algorithms. We enrolled 31 consecutive patients with locally advanced rectal carcinoma. The FDG PET/CT and the high...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i5.4696

    authors: Withofs N,Bernard C,Van der Rest C,Martinive P,Hatt M,Jodogne S,Visvikis D,Lee JA,Coucke PA,Hustinx R

    更新日期:2014-09-08 00:00:00

  • Dose deviations induced by respiratory motion for radiotherapy of lung tumors: Impact of CT reconstruction, plan complexity, and fraction size.

    abstract::A thorax phantom was used to assess radiotherapy dose deviations induced by respiratory motion of the target volume. Both intensity modulated and static, non-modulated treatment plans were planned on CT scans of the phantom. The plans were optimized using various CT reconstructions, to investigate whether they had an ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12847

    authors: Sande EPS,Acosta Roa AM,Hellebust TP

    更新日期:2020-04-01 00:00:00

  • The dose penumbra of a custom-made shield used in hemibody skin electron irradiation.

    abstract::We report our technique for hemibody skin electron irradiation with a custom-made plywood shield. The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a ply...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6367

    authors: Rivers CI,AlDahlawi I,Wang IZ,Singh AK,Podgorsak MB

    更新日期:2016-11-08 00:00:00

  • Comparisons of multiple automated anatomy-based image-guidance methods for patient setup before head/neck external beam radiotherapy.

    abstract::The purpose was to assess the variability in automated translational head/neck setup corrections computed from several different imaging modalities and rigid registration methods using patient anatomy. Shifts were calculated using three commercial and one in-house automated rigid registration methods for nine head/nec...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i1.3337

    authors: Dogan N,Song S,Saleh H,Wu J,Murphy MJ

    更新日期:2010-10-13 00:00:00

  • Comparing gamma knife and cyberknife in patients with brain metastases.

    abstract::The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4095

    authors: Sio TT,Jang S,Lee SW,Curran B,Pyakuryal AP,Sternick ES

    更新日期:2014-01-06 00:00:00

  • Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy.

    abstract::Monte Carlo (MC)-based dose calculations are generally superior to analytical dose calculations (ADC) in modeling the dose distribution for proton pencil beam scanning (PBS) treatments. The purpose of this paper is to present a methodology for commissioning and validating an accurate MC code for PBS utilizing a parame...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12420

    authors: Huang S,Kang M,Souris K,Ainsley C,Solberg TD,McDonough JE,Simone CB 2nd,Lin L

    更新日期:2018-09-01 00:00:00

  • Understanding the impact of RapidArc therapy delivery errors for prostate cancer.

    abstract::The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3409

    authors: Oliver M,Bush K,Zavgorodni S,Ansbacher W,Beckham WA

    更新日期:2011-05-20 00:00:00

  • Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT.

    abstract::The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5126

    authors: Yoo S,Blitzblau R,Yin FF,Horton JK

    更新日期:2015-01-08 00:00:00

  • Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors.

    abstract::The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i5.4931

    authors: Sio TT,Jensen AR,Miller RC,Fong de los Santos LE,Hallemeier CL,Foster NR,Park SS,Bauer HJ,Chang K,Garces YI,Olivier KR

    更新日期:2014-09-08 00:00:00

  • Clinical validation of ring-mounted halcyon linac for lung SBRT: comparison to SBRT-dedicated C-arm linac treatments.

    abstract::Stereotactic body radiotherapy (SBRT) of lung tumors via the ring-mounted Halcyon Linac, a fast kilovoltage cone beam CT-guided treatment with coplanar geometry, a single energy 6MV flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a fast, safe, and feasible treatment modality for select...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13146

    authors: Pokhrel D,Visak J,Critchfield LC,Stephen J,Bernard ME,Randall M,Kudrimoti M

    更新日期:2020-12-20 00:00:00

  • "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy.

    abstract:PURPOSE:Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the "dose of the day". The purpose of this study is to investigate the "dose of the day" calculation accuracy...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12793

    authors: Yuan Z,Rong Y,Benedict SH,Daly ME,Qiu J,Yamamoto T

    更新日期:2020-01-01 00:00:00

  • Retrospective analysis of linear accelerator output constancy checks using process control techniques.

    abstract::Shewhart control charts have previously been suggested as a process control tool for use in routine linear accelerator (linac) output verifications. However, a comprehensive approach to process control has not been investigated for linac output verifications. The purpose of this work is to investigate a comprehensive ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i1.4032

    authors: Sanghangthum T,Suriyapee S,Srisatit S,Pawlicki T

    更新日期:2013-01-07 00:00:00

  • Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

    abstract::In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i3.3105

    authors: Yeboah C,Karotki A,Hunt D,Holly R

    更新日期:2010-06-15 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00

  • Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy.

    abstract::Beam quality correction kQQo (r), which reflects the absorbed energy dependence of the detector, is calculated for solid state detector materials diamond, LiF, Li2B4O7 and Al2O3 for the 137Cs RTR brachytherapy source using the Monte Carlo-based EGSnrc code system. The study also includes calculation of detector-specif...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4445

    authors: Selvam TP,Mishra S,Vishwakarma RS

    更新日期:2014-01-06 00:00:00

  • A routine quality assurance test for CT automatic exposure control systems.

    abstract::The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.6165

    authors: Iball GR,Moore AC,Crawford EJ

    更新日期:2016-07-08 00:00:00

  • Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system.

    abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v5i2.1947

    authors: Wang L,Jacob R,Chen L,Ma C,Movsas B,Feigenberg S,Konski A

    更新日期:2004-04-01 00:00:00

  • Evaluation of cumulative dose for cone-beam computed tomography (CBCT) scans within phantoms made from different compositions using Monte Carlo simulations.

    abstract::Measurement of cumulative dose ƒ(0,150) with a small ionization chamber within standard polymethyl methacrylate (PMMA) CT head and body phantoms, 150 mm in length, is a possible practical method for cone-beam computed tomography (CBCT) dosimetry. This differs from evaluating cumulative dose under scatter equilibrium c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5793

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Oomen K,Gentle DJ

    更新日期:2015-11-08 00:00:00

  • Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.

    abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12618

    authors: Lu KM,Yeh DM,Cao BH,Lin CY,Liang CY,Zhou YB,Tsai CJ

    更新日期:2019-06-01 00:00:00

  • A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.

    abstract:PURPOSE:Volumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery uncertainties associated with small-field dosimetry error and interplay effects...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12878

    authors: Pokhrel D,Visak J,Sanford L

    更新日期:2020-07-01 00:00:00

  • Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy.

    abstract::Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4239

    authors: Davis SD,Parker W,Evans MD

    更新日期:2013-11-04 00:00:00

  • A novel method for radiotherapy patient identification using surface imaging.

    abstract::Performing a procedure on the wrong patient or site is one of the greatest errors that can occur in medicine. The addition of automation has been shown to reduce errors in many processes. In this work we explore the use of an automated patient identification process using optical surface imaging for radiotherapy treat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.6066

    authors: Wiant DB,Verchick Q,Gates P,Vanderstraeten CL,Maurer JM,Hayes TL,Liu H,Sintay BJ

    更新日期:2016-03-08 00:00:00

  • Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions.

    abstract:PURPOSE:The GammaPod is a dedicated prone breast stereotactic radiosurgery (SRS) machine composed of 25 cobalt-60 sources which rotate around the breast to create highly conformal dose distributions for boosts, partial-breast irradiation, or neo-adjuvant SRS. We describe the development and validation of a patient-spec...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12778

    authors: Becker SJ,Niu Y,Mutaf Y,Chen S,Poirier Y,Nichols EM,Yi B

    更新日期:2019-12-01 00:00:00

  • Development of system using beam's eye view images to measure respiratory motion tracking errors in image-guided robotic radiosurgery system.

    abstract::The accuracy of the CyberKnife Synchrony Respiratory Tracking System (SRTS) is considered to be patient-dependent because the SRTS relies on an individual correlation between the internal tumor position (ITP) and the external marker position (EMP), as well as a prediction method to compensate for the delay incurred to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5049

    authors: Inoue M,Shiomi H,Iwata H,Taguchi J,Okawa K,Kikuchi C,Inada K,Iwabuchi M,Murai T,Koike I,Tatewaki K,Ohta S,Inoue T

    更新日期:2015-01-08 00:00:00

  • Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

    abstract::To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherap...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12121

    authors: Ono T,Nakamura M,Hirose Y,Kitsuda K,Ono Y,Ishigaki T,Hiraoka M

    更新日期:2017-09-01 00:00:00