Clinical validation of ring-mounted halcyon linac for lung SBRT: comparison to SBRT-dedicated C-arm linac treatments.

Abstract:

:Stereotactic body radiotherapy (SBRT) of lung tumors via the ring-mounted Halcyon Linac, a fast kilovoltage cone beam CT-guided treatment with coplanar geometry, a single energy 6MV flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a fast, safe, and feasible treatment modality for selected lung cancer patients. Four-dimensional (4D) CT-based treatment plans were generated using advanced AcurosXB algorithm with heterogeneity corrections using an SBRT board and Halcyon couch insert. Halcyon VMAT-SBRT plans with stacked and staggered multileaf collimators produced highly conformal radiosurgical dose distribution to the target, lower intermediate dose spillage, and similar dose to adjacent organs at risks (OARs) compared to SBRT-dedicated highly conformal clinical noncoplanar Truebeam VMAT plans following the RTOG-0813 requirements. Due to low monitor units per fraction and less multileaf collimator (MLC) modulation, the Halcyon VMAT plan can deliver lung SBRT fractions with an overall treatment time of less than 15 min (for 50 Gy in five fractions), significantly improving patient comfort and clinic workflow. Higher pass rates of quality assurance results demonstrate a more accurate treatment delivery on Halcyon. We have implemented Halcyon for lung SBRT treatment in our clinic. We suggest others use Halcyon for lung SBRT treatments using abdominal compression or 4D CT-based treatment planning, thus expanding the access of curative ultra-hypofractionated treatments to other centers with only a Halcyon Linac. Clinical follow-up results for patients treated on Halcyon Linac with lung SBRT is ongoing.

journal_name

J Appl Clin Med Phys

authors

Pokhrel D,Visak J,Critchfield LC,Stephen J,Bernard ME,Randall M,Kudrimoti M

doi

10.1002/acm2.13146

subject

Has Abstract

pub_date

2020-12-20 00:00:00

issn

1526-9914

pub_type

杂志文章
  • Automated phantom analysis for gamma cameras and SPECT: A methodology for use in a clinical setting.

    abstract:PURPOSE:We introduce an automated, quantitative image analysis package for gamma camera and single photon emission computed tomography quality control. Our focus was to produce consistent methods that are feasible in clinical settings and use standard phantoms. METHODS:Four gamma cameras were used to acquire planar im...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13057

    authors: Tazegul TE,Polemi AM,Snyder A,Snyder C,Collins PG

    更新日期:2020-11-03 00:00:00

  • Electrometer offset current due to scattered radiation.

    abstract::Relative dose measurements with small ionization chambers in combination with an electrometer placed in the treatment room ("internal electrometer") show a large dependence on the polarity used. While this was observed previously for percent depth dose curves (PDDs), the effect has not been understood or preventable. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12458

    authors: Wegener S,Sauer OA

    更新日期:2018-11-01 00:00:00

  • Measurement of the interplay effect in lung IMRT treatment using EDR2 films.

    abstract::Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due to the interplay effect between tumor motion and multi-leaf collimator (MLC) leaf motion. In the past, this has been investigated through theoretical analysis,...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i4.2222

    authors: Berbeco RI,Pope CJ,Jiang SB

    更新日期:2006-11-28 00:00:00

  • Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy.

    abstract::Independent treatment planning system (TPS) check with Mobius3D software, log files based quality assurance (QA) with MobiusFX, and phantom measurement-based QA with ArcCHECK were performed and cross verified for head-and-neck (17 patients), chest (16 patients), and abdominal (19 patients) cancer patients who underwen...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13036

    authors: Han C,Yi J,Zhu K,Zhou Y,Ai Y,Zheng X,Xie C,Jin X

    更新日期:2020-10-01 00:00:00

  • Applying three different methods of measuring CTDIfree air to the extended CTDI formalism for wide-beam scanners (IEC 60601-2-44): A comparative study.

    abstract:PURPOSE:The weighted CT dose index (CTDIw ) has been extended for a nominal total collimation width (nT) greater than 40 mm and relies on measurements of CTDIfreeair. The purpose of this work was to compare three methods of measuring CTDIfreeair and subsequent calculations of CTDIw to investigate their clinical appropr...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12363

    authors: Bujila R,Kull L,Danielsson M,Andersson J

    更新日期:2018-07-01 00:00:00

  • Detector system dose verification comparisons for arc therapy: couch vs. gantry mount.

    abstract::The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4495

    authors: Manikandan A,Sarkar B,Nandy M,Sureka CS,Gossman MS,Sujatha N,Rajendran VT

    更新日期:2014-05-08 00:00:00

  • Impact of incorporating visual biofeedback in 4D MRI.

    abstract::Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4D CT. 4D MRI offers improved con-trast although long scan times and irregular breathing patterns can be limiting. To address this, visual biofeedback (VBF) was introduced into 4D MRI. Ten v...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.6017

    authors: To DT,Kim JP,Price RG,Chetty IJ,Glide-Hurst CK

    更新日期:2016-05-08 00:00:00

  • A review of patient questions from physicist-patient consults.

    abstract:PURPOSE:To provide insight into the types of questions asked to medical physicists by patients during one-on-one physicist-patient consults at one institution. MATERIALS AND METHODS:Medical physicists trained in patient communication techniques met with patients to provide an overview of the treatment planning and del...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12942

    authors: Atwood TF,Brown DW,Juang T,Moore KL,McConnell KA,Steers JM,Murphy JD,Mundt AJ,Pawlicki T

    更新日期:2020-08-01 00:00:00

  • Electrocardiogram-gated coronary CT angiography dose estimates using ImPACT.

    abstract::The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.6218

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Koshida K,Matsunaga Y,Haba T,Kawaguchi A,Toyama H,Kato R

    更新日期:2016-07-08 00:00:00

  • Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT.

    abstract::The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5126

    authors: Yoo S,Blitzblau R,Yin FF,Horton JK

    更新日期:2015-01-08 00:00:00

  • A novel method for radiotherapy patient identification using surface imaging.

    abstract::Performing a procedure on the wrong patient or site is one of the greatest errors that can occur in medicine. The addition of automation has been shown to reduce errors in many processes. In this work we explore the use of an automated patient identification process using optical surface imaging for radiotherapy treat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.6066

    authors: Wiant DB,Verchick Q,Gates P,Vanderstraeten CL,Maurer JM,Hayes TL,Liu H,Sintay BJ

    更新日期:2016-03-08 00:00:00

  • Geometric accuracy of the MR imaging techniques in the presence of motion.

    abstract::Magnetic Resonance Imaging (MRI) is increasingly being used for improving tumor delineation and tumor tracking in the presence of respiratory motion. The purpose of this work is to design and build an MR compatible motion platform and to use it for evaluating the geometric accuracy of MR imaging techniques during resp...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12274

    authors: Torfeh T,Hammoud R,El Kaissi T,McGarry M,Aouadi S,Fayad H,Al-Hammadi N

    更新日期:2018-03-01 00:00:00

  • A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator.

    abstract::A quality assurance (QA) procedure was developed to evaluate the congruence between the cone-beam computed tomography (CBCT) image center and the radiation isocenter on a Varian Trilogy linac. In contrast to the published QA procedures, this method did not require a ball bearing (BB) phantom to be placed exactly at th...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i4.3297

    authors: Du W,Yang JN,Chang EL,Luo D,McAleer MF,Shiu A,Martel MK

    更新日期:2010-07-02 00:00:00

  • A fast, independent dose check of HDR plans.

    abstract::High dose rate (HDR) brachytherapy often involves optimization routines to calculate the dwell times and positions of a radioactive source along specified applicator paths. These routines optimize the dwells in such a way as to deliver the prescribed dose at one or more points while satisfying various constraints. The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i2.2530

    authors: Lachaine ME,Gorman JC,Palisca MG

    更新日期:2003-04-01 00:00:00

  • Evaluation and verification of the QFix EncompassTM couch insert for intracranial stereotactic radiosurgery.

    abstract::The QFix EncompassTM stereotactic radiosurgery (SRS) immobilization system consists of a thermoplastic mask that attaches to the couch insert to immobilize patients treated with intracranial SRS. This study evaluates the dosimetric impact and verifies a vendor provided treatment planning system (TPS) model in the Ecli...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12387

    authors: Snyder KC,Xhaferllari I,Huang Y,Siddiqui MS,Chetty IJ,Wen N

    更新日期:2018-07-01 00:00:00

  • Quality assurance for a six degrees-of-freedom table using a 3D printed phantom.

    abstract:PURPOSE:To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS:A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step o...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12227

    authors: Woods K,Ayan AS,Woollard J,Gupta N

    更新日期:2018-01-01 00:00:00

  • Long term stability of a 50 kV X-ray unit for stereotactic irradiation.

    abstract::A low-energy (50 kV) X-ray tube used for the stereotactic irradiation of intracranial lesions has been in use since 1999. The unit is calibrated prior to every procedure and during periodic quality assurance (QA) tests. The unit uses an internal and an external scintillation detector to monitor dose as well as a conve...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i3.2238

    authors: Biggs PJ

    更新日期:2006-08-24 00:00:00

  • Generation of wedge-shaped dose distributions through dynamic multileaf collimator dose delivery.

    abstract::A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to th...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v6i3.2060

    authors: Zhu J

    更新日期:2005-07-01 00:00:00

  • Commissioning and validation of BrainLAB cones for 6X FFF and 10X FFF beams on a Varian TrueBeam STx.

    abstract::Small field dosimetry is a challenging task. The difficulties of small field measurements, particularly stereotactic field size measurements, are highlighted by the large interinstitution variability that can be observed for circular cone collimator commissioning measurements. We believe the best way to improve the co...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4493

    authors: Wiant DB,Terrell JA,Maurer JM,Yount CL,Sintay BJ

    更新日期:2013-11-04 00:00:00

  • Dose variations in tumor volumes and organs at risk during IMRT for head-and-neck cancer.

    abstract::Many head-and-neck cancer (HNC) patients treated with radiotherapy suffer significant anatomical changes due to tumor shrinkage or weight loss. The purpose of this study was to assess dose changes over target volumes and organs at risk during intensity-modulated radiotherapy for HNC patients. Sixteen HNC IMRT patients...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3723

    authors: Beltran M,Ramos M,Rovira JJ,Perez-Hoyos S,Sancho M,Puertas E,Benavente S,Ginjaume M,Giralt J

    更新日期:2012-11-08 00:00:00

  • Independent review of 4DCT scans used for SABR treatment planning.

    abstract::Four-dimensional computerized tomography (4DCT) is required for stereotactic ablative body radiotherapy (SABR) of mobile targets to account for tumor motion during treatment planning and delivery. In this study, we report on the impact of an image review quality assurance process performed prior to treatment planning ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12825

    authors: Antony R,Lonski P,Ungureanu E,Hardcastle N,Yeo A,Siva S,Kron T

    更新日期:2020-03-01 00:00:00

  • Generation and verification of QFix kVue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams.

    abstract::This study details the generation, verification, and implementation of a treatment planning system (TPS) couch top model for patient support system used in conjunction with a dedicated stereotactic linear accelerator. Couch top model was created within the TPS using CT simulation images of the kVue Calpyso-compatible ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.5441

    authors: Gardner SJ,Gulam M,Song K,Li H,Huang Y,Zhao B,Qin Y,Snyder K,Kim J,Gordon J,Chetty IJ,Wen N

    更新日期:2015-07-08 00:00:00

  • Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.

    abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3447

    authors: McMahon R,Zhuang T,Steffey BA,Song H,Craciunescu OI

    更新日期:2011-11-15 00:00:00

  • Frameless stereotactic body radiation therapy for multiple lung metastases.

    abstract::Two patients with multiple lung metastases (≥ 5) were treated using frameless stereotactic body radiation therapy (SBRT) on an Elekta Axesse linear accelerator equipped with an interdigitation-capable multileaf collimator and four-dimensional cone-beam CT (4D CBCT). The technique and the early clinical outcomes were e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4737

    authors: Li Q,Mu J,Gu W,Chen Y,Ning Z,Jin J,Pei H

    更新日期:2014-07-08 00:00:00

  • SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

    abstract::A custom-made computer program, SWIMRT, to construct "multileaf collimator (MLC) machine" file for intensity-modulated radiotherapy (IMRT) fluence maps was developed using MATLAB and the sliding window algorithm. The user can either import a fluence map with a graphical file format created by an external treatment-pla...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i2.2231

    authors: Chow JC,Grigorov GN,Yazdani N

    更新日期:2006-05-25 00:00:00

  • Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy.

    abstract::We have developed a treatment planning protocol for intensity-modulated radiation therapy of the prostate using commercially available inverse planning software. Treatment plans were developed for ten patients using the Corvus version 3.8 planning system, testing various prescription options, including tissue types, d...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v2i2.2614

    authors: Ezzell GA,Schild SE,Wong WW

    更新日期:2001-04-01 00:00:00

  • A feasibility study of multislice X-ray CT imaging of gel dosimeters using the "zero scan" method.

    abstract::This study extends the 'zero scan' method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results demonstrate that zero scan...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4360

    authors: Kakakhel MB,Kairn T,Charles P,Trapp JV

    更新日期:2014-07-08 00:00:00

  • The impact of spectral filtration on image quality in micro-CT system.

    abstract::This paper aims to evaluate the impact of spectral filtration on image quality in a microcomputed tomography (micro-CT) system. A mouse phantom comprising 11rods for modeling lung, muscle, adipose, and bones was scanned with 17 s and 2min, respectively. The current (μA) for each scan was adjusted to achieve identical ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5714

    authors: Ren L,Ghani MU,Wu D,Zheng B,Chen Y,Yang K,Wu X,Liu H

    更新日期:2016-01-08 00:00:00

  • Assessment and management of radiotherapy beam intersections with the treatment couch.

    abstract::The impact of the treatment couch on a radiotherapy plan is rarely fully assessed during the treatment planning process. Incorporating a couch model into the treatment planning system (TPS) enables the planner to avoid or dosimetrically evaluate beam-couch intersections. In this work, we demonstrate how existing TPS t...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i2.3171

    authors: Van Prooijen M,Kanesalingam T,Islam MK,Heaton RK

    更新日期:2010-04-19 00:00:00

  • Statistical process control and verifying positional accuracy of a cobra motion couch using step-wedge quality assurance tool.

    abstract::This study utilizes process control techniques to identify action limits for TomoTherapy couch positioning quality assurance tests. A test was introduced to monitor accuracy of the applied couch offset detection in the TomoTherapy Hi-Art treatment system using the TQA "Step-Wedge Helical" module and MVCT detector. Ind...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12136

    authors: Binny D,Lancaster CM,Trapp JV,Crowe SB

    更新日期:2017-09-01 00:00:00