Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

Abstract:

:To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV.

journal_name

J Appl Clin Med Phys

authors

Ono T,Nakamura M,Hirose Y,Kitsuda K,Ono Y,Ishigaki T,Hiraoka M

doi

10.1002/acm2.12121

subject

Has Abstract

pub_date

2017-09-01 00:00:00

pages

36-42

issue

5

issn

1526-9914

journal_volume

18

pub_type

杂志文章
  • Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.

    abstract::An inverse treatment planning (ITP) module on a commercial treatment planning system (TPS) (Helax AB, Uppsala, Sweden) is being used for an in-house clinical trial for treatment of nasopharyngeal cancer with contralateral parotid sparing. Intensity modulated radiation therapy (IMRT) fields are delivered by step and sh...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i2.2580

    authors: MacKenzie MA,Lachaine M,Murray B,Fallone BG,Robinson D,Field GC

    更新日期:2002-04-01 00:00:00

  • Utilization of cone beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup.

    abstract::The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired onc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i3.4203

    authors: Paluska P,Hanus J,Sefrova J,Rouskova L,Grepl J,Jansa J,Kasaova L,Hodek M,Zouhar M,Vosmik M,Petera J

    更新日期:2013-05-06 00:00:00

  • Evaluation of three APBI techniques under NSABP B-39 guidelines.

    abstract::This work compares two accelerated partial breast irradiation modalities, MammoSite brachytherapy and three dimensional conformal radiotherapy (3D-CRT), to a new method, SAVI brachytherapy, following NSABP B-39 guidelines. A total of 21 patients treated at UC San Diego with the SAVI device were evaluated in this compa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i1.3021

    authors: Scanderbeg D,Yashar C,White G,Rice R,Pawlicki T

    更新日期:2009-12-03 00:00:00

  • Image texture and radiation dose properties in CT.

    abstract::The aim of this study was to compare image noise properties of GE Discovery HD 750 and Toshiba Aquilion ONE. The uniformity section of a Catphan 600 image quality assurance phantom was scanned with both scanners, at different dose levels and with extension rings simulating patients of different sizes. 36 datasets were...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.5900

    authors: Mozejko D,Andersen HK,Pedersen M,Waaler D,Martinsen AC

    更新日期:2016-05-08 00:00:00

  • The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.

    abstract:PURPOSE:To assess the impact of isocenter shifts due to linac gantry and table rotation during cranial stereotactic radiosurgery on D98 , target volume coverage (TVC), conformity (CI), and gradient index (GI). METHODS:Winston-Lutz (WL) checks were performed on two Elekta Synergy linacs. A stereotactic quality assuranc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12854

    authors: Wack LJ,Exner F,Wegener S,Sauer OA

    更新日期:2020-05-01 00:00:00

  • Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification.

    abstract::Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i2.4111

    authors: Casanova Borca V,Pasquino M,Russo G,Grosso P,Cante D,Sciacero P,Girelli G,La Porta MR,Tofani S

    更新日期:2013-03-04 00:00:00

  • Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning.

    abstract::The purpose of this study is to evaluate the accuracy of the electron Monte Carlo (eMC) dose calculation algorithm included in a commercial treatment planning system and compare its performance against an electron pencil beam algorithm. Several tests were performed to explore the system's behavior in simple geometries...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.4636

    authors: Chamberland E,Beaulieu L,Lachance B

    更新日期:2015-05-08 00:00:00

  • An accurate algorithm to match imperfectly matched images for lung tumor detection without markers.

    abstract::In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, gl...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5200

    authors: Rozario T,Bereg S,Yan Y,Chiu T,Liu H,Kearney V,Jiang L,Mao W

    更新日期:2015-05-08 00:00:00

  • Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.

    abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3447

    authors: McMahon R,Zhuang T,Steffey BA,Song H,Craciunescu OI

    更新日期:2011-11-15 00:00:00

  • Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy.

    abstract::Beam quality correction kQQo (r), which reflects the absorbed energy dependence of the detector, is calculated for solid state detector materials diamond, LiF, Li2B4O7 and Al2O3 for the 137Cs RTR brachytherapy source using the Monte Carlo-based EGSnrc code system. The study also includes calculation of detector-specif...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4445

    authors: Selvam TP,Mishra S,Vishwakarma RS

    更新日期:2014-01-06 00:00:00

  • Investigation of optimal display size for viewing T1-weighted MR images of the brain using a digital contrast-detail phantom.

    abstract::We clarified the relationship between the display size of MRI images and observer performance using a digital contrast-detail (d-CD) phantom. The d-CD phantom was developed using Microsoft Visual Basic 2010 Express. It had a 512 × 512 matrix in size and a total of 100 holes, whose diameter increased stepwise from 4 to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5876

    authors: Fujita H,Kuwahata N,Hattori H,Kinoshita H,Fukuda H

    更新日期:2016-01-08 00:00:00

  • The overshoot phenomenon in step-and-shoot IMRT delivery.

    abstract::The control loop in the Varian DMLC system (V4.8) requires approximately 65 msec to monitor and halt the irradiation of a segment, causing an "overshoot" effect: the segment ends on a fractional monitor unit larger than that planned. As a result, the actual MU delivered may differ from that planned. In general, for st...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v2i3.2607

    authors: Ezzell GA,Chungbin S

    更新日期:2001-07-01 00:00:00

  • Automated phantom analysis for gamma cameras and SPECT: A methodology for use in a clinical setting.

    abstract:PURPOSE:We introduce an automated, quantitative image analysis package for gamma camera and single photon emission computed tomography quality control. Our focus was to produce consistent methods that are feasible in clinical settings and use standard phantoms. METHODS:Four gamma cameras were used to acquire planar im...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13057

    authors: Tazegul TE,Polemi AM,Snyder A,Snyder C,Collins PG

    更新日期:2020-11-03 00:00:00

  • Determination of the photon beam attenuation by the Brainlab imaging couch: angular and field size dependence.

    abstract::Highly attenuating radiation treatment couches are no longer useful in the present era of radiotherapy utilizing IMRT and IGRT. Carbon fibers couch tops with its high tensile strength and low density present a useful alternative. The objective of the current study was to quantify the attenuation of megavoltage photons...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i3.2979

    authors: Njeh CF,Raines TW,Saunders MW

    更新日期:2009-06-02 00:00:00

  • Experience in implementing continuous arterial spin labeling on a commercial MR scanner.

    abstract::Continuous arterial spin labeling (CASL) is a technique for performing quantitative perfusion measurements without the need for exogenous contrast agent administration. This technique has seen limited use in the clinic due to problems of poor sensitivity and the potential for artifacts. In addition, CASL requires the ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v6i1.2068

    authors: Steger TR,Jackson EF

    更新日期:2005-01-01 00:00:00

  • Assessment of error in the MV radiation isocenter position calculated with the Elekta XVI software.

    abstract::The assessment of the coincidence of imaging and radiation isocenters is an important task of regular quality assurance of medical linear accelerators (linacs) as recommended in national and international quality assurance guidelines. A previously reported investigation of the accuracy of the Elekta XVI software to lo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12861

    authors: Chojnowski JM,Warr GB,Sykes JR,Thwaites DI

    更新日期:2020-05-01 00:00:00

  • Electrometer offset current due to scattered radiation.

    abstract::Relative dose measurements with small ionization chambers in combination with an electrometer placed in the treatment room ("internal electrometer") show a large dependence on the polarity used. While this was observed previously for percent depth dose curves (PDDs), the effect has not been understood or preventable. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12458

    authors: Wegener S,Sauer OA

    更新日期:2018-11-01 00:00:00

  • Measurement of the interplay effect in lung IMRT treatment using EDR2 films.

    abstract::Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due to the interplay effect between tumor motion and multi-leaf collimator (MLC) leaf motion. In the past, this has been investigated through theoretical analysis,...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i4.2222

    authors: Berbeco RI,Pope CJ,Jiang SB

    更新日期:2006-11-28 00:00:00

  • Mathematical modeling of the optimum pulse structure for safe and effective photo epilation using broadband pulsed light.

    abstract::The objective of this work is the investigation of intense pulsed light (IPL) photoepilation using Monte Carlo simulation to model the effect of the output dosimetry with millisecond exposure used by typical commercial IPL systems. The temporal pulse shape is an important parameter, which may affect the biological tis...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3702

    authors: Ash C,Donne K,Daniel G,Town G,Clement M,Valentine R

    更新日期:2012-09-06 00:00:00

  • Photon and electron backscatter dose and energy spectrum analysis around Lipiodol using flattened and unflattened beams.

    abstract:PURPOSE:The aim of the current study was to evaluate the backscatter dose and energy spectrum from the Lipiodol with flattening filter (FF) and flattening filter-free (FFF) beams. Moreover, the backscatter range, that was defined as the backscatter distance (BD) are revealed. METHODS:6 MVX FF and FFF beams were delive...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12560

    authors: Kawahara D,Ozawa S,Kimura T,Saito A,Nakashima T,Ohno Y,Murakami Y,Nagata Y,Shiinoki T

    更新日期:2019-06-01 00:00:00

  • The investigation on the location effect of external markers in respiratory-gated radiotherapy.

    abstract:PURPOSE:To investigate the effect of the marker placement on the correlation relationship between the motions of external markers and the internal target under different breathing patterns for several lung cancer patients. METHOD AND MATERIAL:To monitor and record simultaneous motions of internal target and associated...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i2.2758

    authors: Yan H,Zhu G,Yang J,Lu M,Ajlouni M,Kim JH,Yin FF

    更新日期:2008-04-16 00:00:00

  • Quality assurance for a six degrees-of-freedom table using a 3D printed phantom.

    abstract:PURPOSE:To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS:A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step o...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12227

    authors: Woods K,Ayan AS,Woollard J,Gupta N

    更新日期:2018-01-01 00:00:00

  • Anatomy-based, patient-specific VMAT QA using EPID or MLC log files.

    abstract::In this project, we investigated the use of an electronic portal imaging device (EPID), together with the treatment planning system (TPS) and MLC log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. The QA analysis results...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5283

    authors: Defoor DL,Vazquez-Quino LA,Mavroidis P,Papanikolaou N,Stathakis S

    更新日期:2015-05-08 00:00:00

  • Radiation therapy plan checks in a paperless clinic.

    abstract::Traditional quality assurance checks of a patient's radiation therapy plan involve printing out treatment parameters from the treatment planning system and the "record and verify" (R&V) system and visually checking the information for one-to-one correspondence. In a paperless environment, one can automate this process...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2905

    authors: Siochi RA,Pennington EC,Waldron TJ,Bayouth JE

    更新日期:2009-01-27 00:00:00

  • SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

    abstract::A custom-made computer program, SWIMRT, to construct "multileaf collimator (MLC) machine" file for intensity-modulated radiotherapy (IMRT) fluence maps was developed using MATLAB and the sliding window algorithm. The user can either import a fluence map with a graphical file format created by an external treatment-pla...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i2.2231

    authors: Chow JC,Grigorov GN,Yazdani N

    更新日期:2006-05-25 00:00:00

  • Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.

    abstract::Stereotactic body radiation therapy (SBRT) has been increasingly used as an efficacious treatment modality for early-stage non-small cell lung cancer. The accuracy of dose calculations is compromised due to the presence of inhomogeneity. For the purpose of a consistent prescription, radiation doses were calculated wit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i2.4011

    authors: Zhuang T,Djemil T,Qi P,Magnelli A,Stephans K,Videtic G,Xia P

    更新日期:2013-03-04 00:00:00

  • Patient-specific 17-segment myocardial modeling on a bull's eye map.

    abstract::The purpose of this study was to develop and validate cardiac computed tomog-raphy (CT) quantitative analysis software with a patient-specific, 17-segment myocardial model that uses electrocardiogram (ECG)-gated cardiac CT images to differentiate between normal controls and severe aortic stenosis (AS) patients. ECG-ga...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6237

    authors: Jung J,Kim YH,Kim N,Yang DH

    更新日期:2016-09-08 00:00:00

  • Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.

    abstract:PURPOSE:Elekta XVI 5.0 allows for four-dimensional cone beam computed tomography (4D CBCT) image acquisition during treatment delivery to monitor intrafraction motion. These images can have poorer image quality due to undersampling of kV projections and treatment beam MV scatter effects. We determine if a universal int...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12755

    authors: Liang J,Lack D,Zhou J,Liu Q,Grills I,Yan D

    更新日期:2019-12-01 00:00:00

  • Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.

    abstract::The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (P...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/acm2.12709

    authors: Zhang Y,Le AH,Tian Z,Iqbal Z,Chiu T,Gu X,Pugachev A,Reynolds R,Park YK,Lin MH,Stojadinovic S

    更新日期:2019-10-01 00:00:00

  • Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6294

    authors: Goodenough D,Levy J,Kristinsson S,Fredriksson J,Olafsdottir H,Healy A

    更新日期:2016-09-08 00:00:00