The investigation on the location effect of external markers in respiratory-gated radiotherapy.

Abstract:

PURPOSE:To investigate the effect of the marker placement on the correlation relationship between the motions of external markers and the internal target under different breathing patterns for several lung cancer patients. METHOD AND MATERIAL:To monitor and record simultaneous motions of internal target and associated surrogate markers during respiratory gated radiotherapy, an infrared camera system synchronized with a medical simulator was installed in our institute. Multiple external markers were placed on the patients' chest wall with proper geometrical arrangement in closely monitoring the motion of skin near tumor. The motion signals of three breathing sessions (free breathing, breath-holding, and free breathing after breath-holding) were recorded and the quality of correlation between them was analyzed. For a single marker motion, its correlation with the internal target was analyzed using cross-covariance function. For the multiple markers, their correlation with the internal target was analyzed based on additive model. RESULT:Seven patients undergoing radiotherapy with right upper or middle lobe lesions were enrolled in this study. Statistic analysis based on the internal-external motion signals shows that the effect of marker location on the quality of its correlation with the internal target is varied from patient to patient. There was no specific marker location where consistently demonstrated superior quality of correlation with the internal target motion over three breathing sessions for all patients. As the composite surrogate signal which was generated from the motions of multiple external markers was used to correlate the internal target motion, significant improvement of the quality of correlation was achieved. CONCLUSION:The correlation of external marker to the internal target could be influenced by several factors such as patient population, marker locations, and breathing patterns, considerably. The quality of correlation and predictability to the internal target furnished by a single external marker is inferior to that of the composite signal generated from multiple external markers. The use of composite signal shows great potential in improving the predictability of internal target motion and presents an effective way to track tumor more accurately.

journal_name

J Appl Clin Med Phys

authors

Yan H,Zhu G,Yang J,Lu M,Ajlouni M,Kim JH,Yin FF

doi

10.1120/jacmp.v9i2.2758

subject

Has Abstract

pub_date

2008-04-16 00:00:00

pages

57-68

issue

2

issn

1526-9914

journal_volume

9

pub_type

杂志文章
  • A feasibility study of multislice X-ray CT imaging of gel dosimeters using the "zero scan" method.

    abstract::This study extends the 'zero scan' method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results demonstrate that zero scan...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4360

    authors: Kakakhel MB,Kairn T,Charles P,Trapp JV

    更新日期:2014-07-08 00:00:00

  • Optimization of motion management parameters in a synchrotron-based spot scanning system.

    abstract:PURPOSE:To quantify the effects of combining layer-based repainting and respiratory gating as a strategy to mitigate the dosimetric degradation caused by the interplay effect between a moving target and dynamic spot-scanning proton delivery. METHODS:An analytic routine modeled three-dimensional dose distributions of p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12702

    authors: Johnson JE,Herman MG,Kruse JJ

    更新日期:2019-09-01 00:00:00

  • Development and performance evaluation of a high-speed multileaf collimator.

    abstract::Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of 3-4 cm/s and a maxi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12026

    authors: Zhang X,Ye P,Zhang H

    更新日期:2017-01-01 00:00:00

  • TOPAS Simulation of the Mevion S250 compact proton therapy unit.

    abstract::As proton therapy becomes increasingly popular, so does the need for Monte Carlo simulation studies involving accurate beam line modeling of proton treatment units. In this study, the 24 beam configurations of the Mevion S250 proton therapy system installed recently at our institution were modeled using the TOolkit fo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12077

    authors: Prusator M,Ahmad S,Chen Y

    更新日期:2017-05-01 00:00:00

  • Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.

    abstract:PURPOSE:Elekta XVI 5.0 allows for four-dimensional cone beam computed tomography (4D CBCT) image acquisition during treatment delivery to monitor intrafraction motion. These images can have poorer image quality due to undersampling of kV projections and treatment beam MV scatter effects. We determine if a universal int...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12755

    authors: Liang J,Lack D,Zhou J,Liu Q,Grills I,Yan D

    更新日期:2019-12-01 00:00:00

  • Geometric accuracy of the MR imaging techniques in the presence of motion.

    abstract::Magnetic Resonance Imaging (MRI) is increasingly being used for improving tumor delineation and tumor tracking in the presence of respiratory motion. The purpose of this work is to design and build an MR compatible motion platform and to use it for evaluating the geometric accuracy of MR imaging techniques during resp...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12274

    authors: Torfeh T,Hammoud R,El Kaissi T,McGarry M,Aouadi S,Fayad H,Al-Hammadi N

    更新日期:2018-03-01 00:00:00

  • Technical Note: Comparison of the internal target volume (ITV) contours and dose calculations on 4DCT, average CBCT, and 4DCBCT imaging for lung stereotactic body radiation therapy (SBRT).

    abstract:PURPOSE:To investigate the differences between internal target volumes (ITVs) contoured on the simulation 4DCT and daily 4DCBCT images for lung cancer patients treated with stereotactic body radiotherapy (SBRT) and determine the dose delivered on 4D planning technique. METHODS:For nine patients, 4DCBCTs were acquired ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13041

    authors: Dumas M,Laugeman E,Sevak P,Snyder KC,Mao W,Chetty IJ,Ajlouni M,Wen N

    更新日期:2020-10-12 00:00:00

  • Calibration coefficients of dosimeters used in mammography for various target/filter combinations.

    abstract::A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5604

    authors: Sekimoto M,Katoh Y,Katoh T

    更新日期:2015-11-08 00:00:00

  • A seed specific dose kernel method for low-energy brachytherapy dosimetry.

    abstract::We describe a method for independently verifying the dose distributions from pre- and post-implant brachytherapy source distributions. Monte Carlo calculations have been performed to characterize the three-dimensional dose distribution in water phantom from a low-energy brachytherapy source. The calculations are perfo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i1.2543

    authors: DeMarco JJ,Solberg TD,Agazaryan N

    更新日期:2003-01-01 00:00:00

  • AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations - Megavoltage Photon and Electron Beams.

    abstract::The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5768

    authors: Smilowitz JB,Das IJ,Feygelman V,Fraass BA,Kry SF,Marshall IR,Mihailidis DN,Ouhib Z,Ritter T,Snyder MG,Fairobent L,AAPM Medical Physics Practice Guideline Task Group.

    更新日期:2015-09-08 00:00:00

  • Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning.

    abstract::The purpose of this study is to evaluate the accuracy of the electron Monte Carlo (eMC) dose calculation algorithm included in a commercial treatment planning system and compare its performance against an electron pencil beam algorithm. Several tests were performed to explore the system's behavior in simple geometries...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.4636

    authors: Chamberland E,Beaulieu L,Lachance B

    更新日期:2015-05-08 00:00:00

  • Free-breathing conformal irradiation of pancreatic cancer.

    abstract::The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncert...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i4.4152

    authors: Solla I,Zucca S,Possanzini M,Piras S,Pusceddu C,Porru S,Meleddu G,Farace P

    更新日期:2013-07-08 00:00:00

  • Understanding the impact of RapidArc therapy delivery errors for prostate cancer.

    abstract::The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3409

    authors: Oliver M,Bush K,Zavgorodni S,Ansbacher W,Beckham WA

    更新日期:2011-05-20 00:00:00

  • Hepatic encephalopathy: a neurochemical, neuroanatomical, and neuropsychological study.

    abstract::Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in con...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i1.2151

    authors: Binesh N,Huda A,Thomas MA,Wyckoff N,Bugbee M,Han S,Rasgon N,Davanzo P,Sayre J,Guze B,Martin P,Fawzy F

    更新日期:2006-01-01 00:00:00

  • Generation of wedge-shaped dose distributions through dynamic multileaf collimator dose delivery.

    abstract::A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to th...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v6i3.2060

    authors: Zhu J

    更新日期:2005-07-01 00:00:00

  • Accelerated tomotherapy delivery with TomoEdge technique.

    abstract::TomoEDGE is an advanced delivery form of tomotherapy which uses a dynamic secondary collimator. This plan comparison study describes the new features, their clinical applicability, and their effect on plan quality and treatment speed. For the first 45 patients worldwide that were scheduled for a treatment with TomoEdg...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i2.4964

    authors: Katayama S,Haefner MF,Mohr A,Schubert K,Oetzel D,Debus J,Sterzing F

    更新日期:2015-03-08 00:00:00

  • Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer.

    abstract::The purpose of this work is to evaluate the volumetric-modulated arc therapy (VMAT) multicriteria optimization (MCO) algorithm clinically available in the RayStation treatment planning system (TPS) and its ability to reduce treatment planning time while providing high dosimetric plan quality. Nine patients with locali...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5410

    authors: Ghandour S,Matzinger O,Pachoud M

    更新日期:2015-05-08 00:00:00

  • An accurate algorithm to match imperfectly matched images for lung tumor detection without markers.

    abstract::In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, gl...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5200

    authors: Rozario T,Bereg S,Yan Y,Chiu T,Liu H,Kearney V,Jiang L,Mao W

    更新日期:2015-05-08 00:00:00

  • On the optimization of bone SPECT/CT in terms of image quality and radiation dose.

    abstract:INTRODUCTION:The purpose of this study was to present the optimization process of CT parameters to reduce patient exposure during bone SPECT/CT without affecting the quality of SPECT images with attenuation correction (AC). MATERIAL AND METHODS:A fillable phantom reflecting realistic bone scintigraphy conditions was d...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13069

    authors: Tulik M,Tulik P,Kowalska T

    更新日期:2020-10-27 00:00:00

  • "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy.

    abstract:PURPOSE:Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the "dose of the day". The purpose of this study is to investigate the "dose of the day" calculation accuracy...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12793

    authors: Yuan Z,Rong Y,Benedict SH,Daly ME,Qiu J,Yamamoto T

    更新日期:2020-01-01 00:00:00

  • Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

    abstract::Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phant...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6148

    authors: Eyadeh MM,Weston MA,Juhasz J,Diamond KR

    更新日期:2016-09-08 00:00:00

  • Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device.

    abstract::A patient with a cardiac ventricular assist device (VAD) with computer-controlled driver presented to our department for radiation therapy. The treatment plan was 4500 cGy to the rectum over 25 fractions with 15MV photon beams. All beams avoided the pump and leads. The response to electromagnetic interference (EMI) wa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i4.2851

    authors: Lasher DE,Wojcicka JB,Malcom R,Shears LL

    更新日期:2008-10-29 00:00:00

  • The overshoot phenomenon in step-and-shoot IMRT delivery.

    abstract::The control loop in the Varian DMLC system (V4.8) requires approximately 65 msec to monitor and halt the irradiation of a segment, causing an "overshoot" effect: the segment ends on a fractional monitor unit larger than that planned. As a result, the actual MU delivered may differ from that planned. In general, for st...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v2i3.2607

    authors: Ezzell GA,Chungbin S

    更新日期:2001-07-01 00:00:00

  • Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.

    abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12618

    authors: Lu KM,Yeh DM,Cao BH,Lin CY,Liang CY,Zhou YB,Tsai CJ

    更新日期:2019-06-01 00:00:00

  • Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.

    abstract:PURPOSE:To evaluate the quality of patient-specific complicated treatment plans, including commercialized treatment planning systems (TPS) and commissioned beam data, we developed a process of quality assurance (QA) using a Monte Carlo (MC) platform. Specifically, we constructed an interface system that automatically c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12718

    authors: Lee B,Jeong S,Chung K,Yoon M,Park HC,Han Y,Jung SH

    更新日期:2019-10-01 00:00:00

  • Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning.

    abstract::The monochromatic images acquired by Gemstone spectral imaging (GSI) mode on the GE CT750 HD theoretically determines the computed tomography (CT) number more accurately than that of conventional scanner. Using the former, the CT number is calculated from (synthesized) monoenergetic X-ray data. We reasoned that the mo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i5.4335

    authors: Yagi M,Ueguchi T,Koizumi M,Ogata T,Yamada S,Takahashi Y,Sumida I,Akino Y,Konishi K,Isohashi F,Tomiyama N,Yoshioka Y,Ogawa K

    更新日期:2013-09-06 00:00:00

  • Optimization of intra-voxel incoherent motion measurement in diffusion-weighted imaging of breast cancer.

    abstract:PURPOSE:The purpose of this study was to optimize intra-voxel incoherent motion (IVIM) measurement in diffusion-weighted imaging (DWI) of breast cancer by separating perfusion and diffusion effects through the determination of an optimal threshold b-value, thus benign and cancerous breast tissues can be accurately diff...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12065

    authors: Chen W,Zhang J,Long D,Wang Z,Zhu JM

    更新日期:2017-05-01 00:00:00

  • New adaptive statistical iterative reconstruction ASiR-V: Assessment of noise performance in comparison to ASiR.

    abstract:PURPOSE:To assess the noise characteristics of the new adaptive statistical iterative reconstruction (ASiR-V) in comparison to ASiR. METHODS:A water phantom was acquired with common clinical scanning parameters, at five different levels of CTDIvol . Images were reconstructed with different kernels (STD, SOFT, and BONE...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12253

    authors: De Marco P,Origgi D

    更新日期:2018-03-01 00:00:00

  • Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

    abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3845

    authors: Arunachalam K,Craciunescu OI,Markewitz EJ,Maccarini PF,Schlorff JL,Stauffer PR

    更新日期:2012-09-06 00:00:00

  • Remote dosimetric auditing of clinical trials: The need for vendor specific models to convert images to dose.

    abstract:INTRODUCTION:A previous pilot study has demonstrated the feasibility of a novel image-based approach for remote dosimetric auditing of clinical trials. The approach uses a model to convert in-air acquired intensity modulated radiotherapy (IMRT) images to delivered dose inside a virtual phantom. The model was developed ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12521

    authors: Miri N,Vial P,Greer PB

    更新日期:2019-01-01 00:00:00