Measurement of the interplay effect in lung IMRT treatment using EDR2 films.

Abstract:

:Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due to the interplay effect between tumor motion and multi-leaf collimator (MLC) leaf motion. In the past, this has been investigated through theoretical analysis, computer simulation, and experimental measurement using an ionization chamber dosimeter. In the work presented here, the interplay effect was studied experimentally in 2D, using Kodak EDR2 films. A five-field lung IMRT plan was delivered to a solid water phantom with embedded film. The phantom was placed on a motor-driven platform with a sinusoidal motion to simulate the respiration induced tumor motion. The delivery of each field began at one of eight equally spaced initial breathing phases. The dose distribution for each treatment fraction was estimated by combining the dose distributions for all fields with randomly sampled initial breathing phases. The dose variation caused by the interplay effect was estimated by looking at the dose values from 1000 trials of 30 fractions. It was found that, on a day-to-day basis, the standard deviation of the dose to a given pixel in the high dose region could be as high as 2-3% due to the motion interplay effect. After thirty fractions, the standard deviation in the dose to each pixel is reduced to about 0.3-0.5%. However, compared to the static delivery, the dose distribution from a thirty-fraction case in the presence of motion shows some under-dosing in the region of interest. Our results indicate that the interplay effect is of no significant consequence to tumor dose coverage in lung IMRT delivery over the entire course of a thirty-fraction treatment.

journal_name

J Appl Clin Med Phys

authors

Berbeco RI,Pope CJ,Jiang SB

doi

10.1120/jacmp.v7i4.2222

subject

Has Abstract

pub_date

2006-11-28 00:00:00

pages

33-42

issue

4

issn

1526-9914

journal_volume

7

pub_type

杂志文章
  • The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.

    abstract:PURPOSE:To assess the impact of isocenter shifts due to linac gantry and table rotation during cranial stereotactic radiosurgery on D98 , target volume coverage (TVC), conformity (CI), and gradient index (GI). METHODS:Winston-Lutz (WL) checks were performed on two Elekta Synergy linacs. A stereotactic quality assuranc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12854

    authors: Wack LJ,Exner F,Wegener S,Sauer OA

    更新日期:2020-05-01 00:00:00

  • A new frontier of image guidance: Organs at risk avoidance with MRI-guided respiratory-gated intensity modulated radiotherapy: Technical note and report of a case.

    abstract::The case of a 50-year-old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri-60-Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery a...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12575

    authors: Massaccesi M,Cusumano D,Boldrini L,Dinapoli N,Fionda B,Teodoli S,Azario L,Mattiucci GC,Balducci M,Cellini F,Valentini V

    更新日期:2019-06-01 00:00:00

  • Linac-based stereotactic radiosurgery (SRS) in the treatment of refractory trigeminal neuralgia: Detailed description of SRS procedure and reported clinical outcomes.

    abstract:PURPOSE/OBJECTIVES:To present our linac-based SRS procedural technique for medically and/or surgically refractory trigeminal neuralgia (TN) treatment and simultaneously report our clinical outcomes. MATERIALS AND METHODS:Twenty-seven refractory TN patients who were treated with a single fraction of 80 Gy to TN. Treatm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12057

    authors: Pokhrel D,Sood S,McClinton C,Saleh H,Badkul R,Jiang H,Stepp T,Camarata P,Wang F

    更新日期:2017-03-01 00:00:00

  • Validation of the preconfigured Varian Ethos Acuros XB Beam Model for treatment planning dose calculations: A dosimetric study.

    abstract::Varian (Palo Alto, California, United States) recently released an online adaptation treatment platform, Ethos, which has introduced a new Dose Preview and Automated Plan Generation module despite sharing identical beam data with the existing Halcyon linac. The module incorporates a preconfigured beam model and the Ac...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13056

    authors: Hu Y,Byrne M,Archibald-Heeren B,Collett N,Liu G,Aland T

    更新日期:2020-12-01 00:00:00

  • Gamma Knife® icon CBCT offers improved localization workflow for frame-based treatment.

    abstract:OBJECT:The purpose of this study was to compare two methods of stereotactic localization in Gamma Knife treatment planning: cone beam computed tomography (CBCT) or fiducial. While the fiducial method is the traditional method of localization, CBCT is now available for use with the Gamma Knife Icon. This study seeks to ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12745

    authors: Duggar WN,Morris B,Fatemi A,Bonds J,He R,Kanakamedala M,Rey-Dios R,Vijayakumar S,Yang C

    更新日期:2019-11-01 00:00:00

  • Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy.

    abstract::Independent treatment planning system (TPS) check with Mobius3D software, log files based quality assurance (QA) with MobiusFX, and phantom measurement-based QA with ArcCHECK were performed and cross verified for head-and-neck (17 patients), chest (16 patients), and abdominal (19 patients) cancer patients who underwen...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13036

    authors: Han C,Yi J,Zhu K,Zhou Y,Ai Y,Zheng X,Xie C,Jin X

    更新日期:2020-10-01 00:00:00

  • An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images.

    abstract:PURPOSE:The purpose of this study was to introduce a new algorithm for automated measurement of the modulation transfer function (MTF) using an edge of a readily available phantom and to evaluate the effect of reconstruction filter and field of view (FOV) on the spatial resolution in the CT images. METHODS:Our automat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12476

    authors: Anam C,Fujibuchi T,Budi WS,Haryanto F,Dougherty G

    更新日期:2018-11-01 00:00:00

  • Optimization of motion management parameters in a synchrotron-based spot scanning system.

    abstract:PURPOSE:To quantify the effects of combining layer-based repainting and respiratory gating as a strategy to mitigate the dosimetric degradation caused by the interplay effect between a moving target and dynamic spot-scanning proton delivery. METHODS:An analytic routine modeled three-dimensional dose distributions of p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12702

    authors: Johnson JE,Herman MG,Kruse JJ

    更新日期:2019-09-01 00:00:00

  • Long term stability of a 50 kV X-ray unit for stereotactic irradiation.

    abstract::A low-energy (50 kV) X-ray tube used for the stereotactic irradiation of intracranial lesions has been in use since 1999. The unit is calibrated prior to every procedure and during periodic quality assurance (QA) tests. The unit uses an internal and an external scintillation detector to monitor dose as well as a conve...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i3.2238

    authors: Biggs PJ

    更新日期:2006-08-24 00:00:00

  • Independent review of 4DCT scans used for SABR treatment planning.

    abstract::Four-dimensional computerized tomography (4DCT) is required for stereotactic ablative body radiotherapy (SABR) of mobile targets to account for tumor motion during treatment planning and delivery. In this study, we report on the impact of an image review quality assurance process performed prior to treatment planning ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12825

    authors: Antony R,Lonski P,Ungureanu E,Hardcastle N,Yeo A,Siva S,Kron T

    更新日期:2020-03-01 00:00:00

  • Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device.

    abstract::A patient with a cardiac ventricular assist device (VAD) with computer-controlled driver presented to our department for radiation therapy. The treatment plan was 4500 cGy to the rectum over 25 fractions with 15MV photon beams. All beams avoided the pump and leads. The response to electromagnetic interference (EMI) wa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i4.2851

    authors: Lasher DE,Wojcicka JB,Malcom R,Shears LL

    更新日期:2008-10-29 00:00:00

  • Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat.

    abstract::We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i1.3146

    authors: Price MJ,Kry SF,Eifel PJ,Salehpour M,Mourtada F

    更新日期:2010-01-28 00:00:00

  • Dosimetric comparison of three intensity-modulated radiation therapies for left breast cancer after breast-conserving surgery.

    abstract:PURPOSE:This study aimed to evaluate dosimetric differences of intensity-modulated radiation therapy (IMRT) in target and normal tissues after breast-conserving surgery. METHODS:IMRT five-field plan I, IMRT six-field plan II, and field-in-field-direct machine parameter optimization-IMRT plan III were designed for each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12287

    authors: Zhang HW,Hu B,Xie C,Wang YL

    更新日期:2018-05-01 00:00:00

  • Improved dosimetric accuracy with semi-automatic contour propagation of organs-at-risk in glioblastoma patients undergoing chemoradiation.

    abstract:BACKGROUND:We study the changes in organs-at-risk (OARs) morphology as contoured on serial MRIs during chemoradiation therapy (CRT) of glioblastoma (GBM). The dosimetric implication of assuming non-deformable OAR changes and the accuracy and feasibility of semi-automatic OAR contour propagation are investigated. METHO...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12758

    authors: Lee S,Stewart J,Lee Y,Myrehaug S,Sahgal A,Ruschin M,Tseng CL

    更新日期:2019-12-01 00:00:00

  • Quality assurance for a six degrees-of-freedom table using a 3D printed phantom.

    abstract:PURPOSE:To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS:A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step o...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12227

    authors: Woods K,Ayan AS,Woollard J,Gupta N

    更新日期:2018-01-01 00:00:00

  • Impact of incorporating visual biofeedback in 4D MRI.

    abstract::Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4D CT. 4D MRI offers improved con-trast although long scan times and irregular breathing patterns can be limiting. To address this, visual biofeedback (VBF) was introduced into 4D MRI. Ten v...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.6017

    authors: To DT,Kim JP,Price RG,Chetty IJ,Glide-Hurst CK

    更新日期:2016-05-08 00:00:00

  • Maximum MLC opening effect in dynamic delivery of IMRT: leaf-positional analysis.

    abstract::The analysis of dynamic multileaf collimator (MLC) positions for the delivered intensity-modulated radiotherapy (IMRT) plans is crucial in that it may capture dose delivery problems otherwise difficult to observe and quantify in the conventional dosimetric measurements with film or with an ionization chamber. In some ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v6i2.2076

    authors: Zygmanski P,Hacker F,Friesen S,Rodenbush R,Lu HM,Chin L

    更新日期:2005-04-01 00:00:00

  • Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy.

    abstract::The objectives of this project are to quantify the dose reduction effect provided by a lead shield for patients with cardiac implantable electronic devices (CIED) during a clinically realistic radiation treatment on phantom and to provide a simple model of dose estimation to predict dose received by CIED in a wide ran...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5317

    authors: Bourgouin A,Varfalvy N,Archambault L

    更新日期:2015-11-08 00:00:00

  • Quantitative variations in texture analysis features dependent on MRI scanning parameters: A phantom model.

    abstract:OBJECTIVES:To evaluate the influence of MRI scanning parameters on texture analysis features. METHODS:Publicly available data from the Reference Image Database to Evaluate Therapy Response (RIDER) project sponsored by The Cancer Imaging Archive included MRIs on a phantom comprised of 18 25-mm doped, gel-filled tubes, ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12482

    authors: Buch K,Kuno H,Qureshi MM,Li B,Sakai O

    更新日期:2018-11-01 00:00:00

  • Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system.

    abstract::We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patient's thorax, to synchronize radiation from a linear accelerator with the ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v2i4.2596

    authors: Mageras GS,Yorke E,Rosenzweig K,Braban L,Keatley E,Ford E,Leibel SA,Ling CC

    更新日期:2001-10-01 00:00:00

  • Using an onboard kilovoltage imager to measure setup deviation in intensity-modulated radiation therapy for head-and-neck patients.

    abstract::The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i4.2439

    authors: Mechalakos JG,Hunt MA,Lee NY,Hong LX,Ling CC,Amols HI

    更新日期:2007-09-24 00:00:00

  • Automated phantom analysis for gamma cameras and SPECT: A methodology for use in a clinical setting.

    abstract:PURPOSE:We introduce an automated, quantitative image analysis package for gamma camera and single photon emission computed tomography quality control. Our focus was to produce consistent methods that are feasible in clinical settings and use standard phantoms. METHODS:Four gamma cameras were used to acquire planar im...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13057

    authors: Tazegul TE,Polemi AM,Snyder A,Snyder C,Collins PG

    更新日期:2020-11-03 00:00:00

  • Mechanisms and prevention of thermal injury from gamma radiosurgery headframes during 3T MR imaging.

    abstract::Magnetic resonance imaging (MRI) is regularly used for stereotactic imaging of Gamma Knife (GK) radiosurgery patients for GK treatment planning. MRI-induced thermal injuries have occurred and been reported for GK patients with attached metallic headframes. Depending on the specific MR imaging and headframe conditions,...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i4.3613

    authors: Bennett MC,Wiant DB,Gersh JA,Dolesh W,Ding X,Best RC,Bourland JD

    更新日期:2012-07-05 00:00:00

  • On correlations in IMRT planning aims.

    abstract::The purpose was to study correlations amongst IMRT DVH evaluation points and how their relaxation impacts the overall plan. 100 head-and-neck cancer cases, using the Eclipse treatment planning system with the same protocol, are statisti-cally analyzed for PTV, brainstem, and spinal cord. To measure variations amongst ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6411

    authors: Roy A,Das IJ,Nohadani O

    更新日期:2016-11-08 00:00:00

  • Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

    abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3845

    authors: Arunachalam K,Craciunescu OI,Markewitz EJ,Maccarini PF,Schlorff JL,Stauffer PR

    更新日期:2012-09-06 00:00:00

  • Two-year experience with the commercial Gamma Knife Check software.

    abstract::The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 wa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.5547

    authors: Xu AY,Bhatnagar J,Bednarz G,Novotny J Jr,Flickinger J,Lunsford LD,Huq MS

    更新日期:2016-07-08 00:00:00

  • Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.

    abstract::For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dos...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5514

    authors: Liu H,Zhuang T,Stephans K,Videtic G,Raithel S,Djemil T,Xia P

    更新日期:2015-11-08 00:00:00

  • Dose variations in tumor volumes and organs at risk during IMRT for head-and-neck cancer.

    abstract::Many head-and-neck cancer (HNC) patients treated with radiotherapy suffer significant anatomical changes due to tumor shrinkage or weight loss. The purpose of this study was to assess dose changes over target volumes and organs at risk during intensity-modulated radiotherapy for HNC patients. Sixteen HNC IMRT patients...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3723

    authors: Beltran M,Ramos M,Rovira JJ,Perez-Hoyos S,Sancho M,Puertas E,Benavente S,Ginjaume M,Giralt J

    更新日期:2012-11-08 00:00:00

  • Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.

    abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3447

    authors: McMahon R,Zhuang T,Steffey BA,Song H,Craciunescu OI

    更新日期:2011-11-15 00:00:00

  • The investigation on the location effect of external markers in respiratory-gated radiotherapy.

    abstract:PURPOSE:To investigate the effect of the marker placement on the correlation relationship between the motions of external markers and the internal target under different breathing patterns for several lung cancer patients. METHOD AND MATERIAL:To monitor and record simultaneous motions of internal target and associated...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i2.2758

    authors: Yan H,Zhu G,Yang J,Lu M,Ajlouni M,Kim JH,Yin FF

    更新日期:2008-04-16 00:00:00