"Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy.

Abstract:

PURPOSE:Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the "dose of the day". The purpose of this study is to investigate the "dose of the day" calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. METHODS:A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re-planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT-based and rCT-based accumulated doses was evaluated using the Bland-Altman analysis. RESULTS:Mean differences in dose-volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of ± 5% for the target volume, lung, esophagus, and heart. For spinal cord Dmax , a large mean difference of -5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). CONCLUSION:This study demonstrated a reasonable agreement in dose-volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the "dose of the day", and thus facilitating the process of ART for lung cancer.

journal_name

J Appl Clin Med Phys

authors

Yuan Z,Rong Y,Benedict SH,Daly ME,Qiu J,Yamamoto T

doi

10.1002/acm2.12793

subject

Has Abstract

pub_date

2020-01-01 00:00:00

pages

88-94

issue

1

issn

1526-9914

journal_volume

21

pub_type

杂志文章
  • Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy.

    abstract::We have developed a treatment planning protocol for intensity-modulated radiation therapy of the prostate using commercially available inverse planning software. Treatment plans were developed for ten patients using the Corvus version 3.8 planning system, testing various prescription options, including tissue types, d...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v2i2.2614

    authors: Ezzell GA,Schild SE,Wong WW

    更新日期:2001-04-01 00:00:00

  • Dosimetric benefits of respiratory gating: a preliminary study.

    abstract::In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (C...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.26.146

    authors: Butler LE,Forster KM,Stevens CW,Bloch C,Liu HH,Tucker SL,Komaki R,Liao Z,Starkschall G

    更新日期:2004-01-01 00:00:00

  • Comparative analysis for renal stereotactic body radiotherapy using Cyberknife, VMAT and proton therapy based treatment planning.

    abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12308

    authors: Baydoun A,Vapiwala N,Ponsky LE,Awan M,Kassaee A,Sutton D,Podder TK,Zhang Y,Dobbins D,Muzic RF Jr,Traughber B,Machtay M,Ellis R

    更新日期:2018-03-14 00:00:00

  • Free-breathing conformal irradiation of pancreatic cancer.

    abstract::The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncert...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i4.4152

    authors: Solla I,Zucca S,Possanzini M,Piras S,Pusceddu C,Porru S,Meleddu G,Farace P

    更新日期:2013-07-08 00:00:00

  • Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

    abstract::Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phant...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6148

    authors: Eyadeh MM,Weston MA,Juhasz J,Diamond KR

    更新日期:2016-09-08 00:00:00

  • Anatomy-based, patient-specific VMAT QA using EPID or MLC log files.

    abstract::In this project, we investigated the use of an electronic portal imaging device (EPID), together with the treatment planning system (TPS) and MLC log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. The QA analysis results...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.5283

    authors: Defoor DL,Vazquez-Quino LA,Mavroidis P,Papanikolaou N,Stathakis S

    更新日期:2015-05-08 00:00:00

  • Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system.

    abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v5i2.1947

    authors: Wang L,Jacob R,Chen L,Ma C,Movsas B,Feigenberg S,Konski A

    更新日期:2004-04-01 00:00:00

  • Calculating the peak skin dose resulting from fluoroscopically-guided interventions. Part II: case studies.

    abstract::Part II of this review article presents four case studies for which peak skin doses are calculated following the methods outlined in Part I of this review. The data available in the cases ranges from proprietary dose reports to fluoroscopy time and number of digital acquisition frames only. Flowcharts are provided for...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i1.3693

    authors: Jones AK,Pasciak AS

    更新日期:2012-01-05 00:00:00

  • Using C-Arm X-ray images from marker insertion to confirm the gold fiducial marker identification in an MRI-only prostate radiotherapy workflow.

    abstract::Prostate cancer radiotherapy workflows, solely based on magnetic resonance imaging (MRI), are now in clinical use. In these workflows, intraprostatic gold fiducial markers (GFM) show similar signal behavior as calcifications and bleeding in T2-weighted MRI-images. Accurate GFM identification in MRI-only radiotherapy w...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12478

    authors: Gustafsson C,Persson E,Gunnlaugsson A,Olsson LE

    更新日期:2018-11-01 00:00:00

  • Investigation of optimal display size for viewing T1-weighted MR images of the brain using a digital contrast-detail phantom.

    abstract::We clarified the relationship between the display size of MRI images and observer performance using a digital contrast-detail (d-CD) phantom. The d-CD phantom was developed using Microsoft Visual Basic 2010 Express. It had a 512 × 512 matrix in size and a total of 100 holes, whose diameter increased stepwise from 4 to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5876

    authors: Fujita H,Kuwahata N,Hattori H,Kinoshita H,Fukuda H

    更新日期:2016-01-08 00:00:00

  • The dose penumbra of a custom-made shield used in hemibody skin electron irradiation.

    abstract::We report our technique for hemibody skin electron irradiation with a custom-made plywood shield. The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a ply...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6367

    authors: Rivers CI,AlDahlawi I,Wang IZ,Singh AK,Podgorsak MB

    更新日期:2016-11-08 00:00:00

  • MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

    abstract::This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3877

    authors: Natanasabapathi G,Subbiah V,Kale SS,Rath GK,Senthilkumaran S,Thulkar S,Subramani V,Laviraj MA,Bisht RK,Mahapatra AK

    更新日期:2012-11-08 00:00:00

  • SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

    abstract::A custom-made computer program, SWIMRT, to construct "multileaf collimator (MLC) machine" file for intensity-modulated radiotherapy (IMRT) fluence maps was developed using MATLAB and the sliding window algorithm. The user can either import a fluence map with a graphical file format created by an external treatment-pla...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i2.2231

    authors: Chow JC,Grigorov GN,Yazdani N

    更新日期:2006-05-25 00:00:00

  • Frameless stereotactic body radiation therapy for multiple lung metastases.

    abstract::Two patients with multiple lung metastases (≥ 5) were treated using frameless stereotactic body radiation therapy (SBRT) on an Elekta Axesse linear accelerator equipped with an interdigitation-capable multileaf collimator and four-dimensional cone-beam CT (4D CBCT). The technique and the early clinical outcomes were e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4737

    authors: Li Q,Mu J,Gu W,Chen Y,Ning Z,Jin J,Pei H

    更新日期:2014-07-08 00:00:00

  • Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma.

    abstract::We investigate the role of adaptive radiation therapy in pediatric patients with diffuse pontine glioma and the impact of steroid-related weight gain on treatment parameters utilizing cone-beam CT. Fifteen patients with diffuse pontine glioma were treated with three-dimensional conformal radiation therapy and enrolled...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:

    authors: Beltran C,Sharma S,Merchant TE

    更新日期:2011-01-30 00:00:00

  • Use of a radioactive check device for redundancy check of ionization chambers.

    abstract::The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The io...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v1i4.2636

    authors: Sidhu NP,Rouvas A,Cadman P

    更新日期:2000-10-01 00:00:00

  • Electron energy constancy verification using a double-wedge phantom.

    abstract::Routine constancy checks of electron energy are often time consuming because of the necessity to measure a dose at two depths. A technique is described that uses a double-wedge shaped phantom positioned on a Profiler diode array for measuring an electron energy constancy metric similar to R(50). The double-wedge elect...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i3.2516

    authors: Wells DM,Picco PJ,Ansbacher W

    更新日期:2003-07-01 00:00:00

  • Bleeding detection in wireless capsule endoscopy videos - Color versus texture features.

    abstract::Wireless capsule endoscopy (WCE) is an effective technology that can be used to make a gastrointestinal (GI) tract diagnosis of various lesions and abnormalities. Due to a long time required to pass through the GI tract, the resulting WCE data stream contains a large number of frames which leads to a tedious job for c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12662

    authors: Pogorelov K,Suman S,Azmadi Hussin F,Saeed Malik A,Ostroukhova O,Riegler M,Halvorsen P,Hooi Ho S,Goh KL

    更新日期:2019-08-01 00:00:00

  • Small field electron beam dosimetry using MOSFET detector.

    abstract::The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small fi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i1.3267

    authors: Amin MN,Heaton R,Norrlinger B,Islam MK

    更新日期:2010-10-04 00:00:00

  • Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study.

    abstract:PURPOSE:Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed "distributively" on any of the matched linacs. The degree to which machines are matched and how this translate...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12567

    authors: Rijken J,Schachenmayr H,Crowe S,Kairn T,Trapp J

    更新日期:2019-04-01 00:00:00

  • Comparison of two algorithms for determining beam weights and wedge filters.

    abstract::This article compares two algorithms for determining beam weights and wedge filters for conformal treatment planning. One algorithm, which is based on dose-gradient analysis, provides analytic formulas for determining beam weights, wedge angles, and collimator angles (i.e., wedge orientations) so that the dose distrib...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i3.2562

    authors: Dai J,Zhu Y

    更新日期:2002-07-01 00:00:00

  • Feasibility of the new copper pipe method for evaluating half-value layer in computed tomography: A measurement and Monte Carlo simulation study.

    abstract::This study aimed to verify the accuracy of half-value layer (HVL) measured using the new copper pipe method with the CT ionization chamber while the X-ray tube is rotating and to compare it with the conventional nonrotating method and Monte Carlo simulation method based on the actual measurement and geometry of the ne...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12780

    authors: Okubo R,Matsubara K,Chusin T,Hibino T,Ito Y

    更新日期:2019-12-01 00:00:00

  • Monte Carlo investigation of collapsed versus rotated IMRT plan verification.

    abstract::IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at t...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4681

    authors: Conneely E,Alexander A,Ruo R,Chung E,Seuntjens J,Foley MJ

    更新日期:2014-05-08 00:00:00

  • Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife.

    abstract::We have investigated the combined effect of tissue heterogeneity and its variation associated with geometric error in stereotactic body radiotherapy (SBRT) for lung cancer. The treatment plans for eight lung cancer patients were calculated using effective path length (EPL) correction and Monte Carlo (MC) algorithms, w...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5397

    authors: Kang KM,Jeong BK,Choi HS,Yoo SH,Hwang UJ,Lim YK,Jeong H

    更新日期:2015-09-08 00:00:00

  • Applying three different methods of measuring CTDIfree air to the extended CTDI formalism for wide-beam scanners (IEC 60601-2-44): A comparative study.

    abstract:PURPOSE:The weighted CT dose index (CTDIw ) has been extended for a nominal total collimation width (nT) greater than 40 mm and relies on measurements of CTDIfreeair. The purpose of this work was to compare three methods of measuring CTDIfreeair and subsequent calculations of CTDIw to investigate their clinical appropr...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12363

    authors: Bujila R,Kull L,Danielsson M,Andersson J

    更新日期:2018-07-01 00:00:00

  • Technical Note: Comparison of the internal target volume (ITV) contours and dose calculations on 4DCT, average CBCT, and 4DCBCT imaging for lung stereotactic body radiation therapy (SBRT).

    abstract:PURPOSE:To investigate the differences between internal target volumes (ITVs) contoured on the simulation 4DCT and daily 4DCBCT images for lung cancer patients treated with stereotactic body radiotherapy (SBRT) and determine the dose delivered on 4D planning technique. METHODS:For nine patients, 4DCBCTs were acquired ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13041

    authors: Dumas M,Laugeman E,Sevak P,Snyder KC,Mao W,Chetty IJ,Ajlouni M,Wen N

    更新日期:2020-10-12 00:00:00

  • AAPM Task Group 103 report on peer review in clinical radiation oncology physics.

    abstract::This report provides guidelines for a peer review process between two clinical radiation oncology physicists. While the Task Group's work was primarily focused on ensuring timely and productive independent reviews for physicists in solo practice, these guidelines may also be appropriate for physicists in a group setti...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章,实务指引

    doi:10.1120/jacmp.v6i4.2142

    authors: Halvorsen PH,Das IJ,Fraser M,Freedman DJ,Rice RE 3rd,Ibbott GS,Parsai EI,Robin TT Jr,Thomadsen BR,American Association of Physicists in Medicine.

    更新日期:2005-10-01 00:00:00

  • Effectiveness of a novel gas-release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy.

    abstract::Endorectal balloons (ERBs) are routinely used in prostate proton radiation therapy to immobilize the prostate and spare the rectal wall. Rectal gas can distend the rectum and displace the prostate even in the presence of ERBs. The purpose of this work was to quantify the effects an ERB with a passive gas release condu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3945

    authors: Wootton LS,Kudchadker RJ,Beddar AS,Lee AK

    更新日期:2012-09-06 00:00:00

  • Clinical validation of ring-mounted halcyon linac for lung SBRT: comparison to SBRT-dedicated C-arm linac treatments.

    abstract::Stereotactic body radiotherapy (SBRT) of lung tumors via the ring-mounted Halcyon Linac, a fast kilovoltage cone beam CT-guided treatment with coplanar geometry, a single energy 6MV flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a fast, safe, and feasible treatment modality for select...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13146

    authors: Pokhrel D,Visak J,Critchfield LC,Stephen J,Bernard ME,Randall M,Kudrimoti M

    更新日期:2020-12-20 00:00:00

  • Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy.

    abstract::MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5057

    authors: Dhanesar SK,Lim TY,Du W,Bruno TL,Frank SJ,Kudchadker RJ

    更新日期:2015-09-08 00:00:00