Benzodiazepine misuse by drug addicts.

Abstract:

:Using a high-performance liquid chromatography method, we measured seven commonly prescribed benzodiazepines (chlordiazepoxide, nitrazepam, nordiazepam, oxazepam, lorazepam, temazepam and diazepam) in 100 urine samples obtained from patients attending the Leeds Addiction Unit. All of the urines selected for investigation were positive for benzodiazepines using an EMIT (Enzyme Immunoassay) screen. Forty-four of the urines contained a range of benzodiazepines, none of which had been prescribed. Nitrazepam was detected most frequently (61 urine samples), but had not been prescribed to any of the patients in this study. Chlordiazepoxide was detected in 49 urine samples, although it had been prescribed to only five patients. Temazepam was detected in 28 urine samples. Fourteen patients providing 21 urine samples had been prescribed temazepam for treatment. However, temazepam was detected in only 14 of these samples. Multiple benzodiazepine abuse was evident from the high rate of detection of unrelated benzodiazepines.

journal_name

Ann Clin Biochem

authors

Garretty DJ,Wolff K,Hay AW,Raistrick D

doi

10.1177/000456329703400110

subject

Has Abstract

pub_date

1997-01-01 00:00:00

pages

68-73

eissn

0004-5632

issn

1758-1001

journal_volume

34 ( Pt 1)

pub_type

杂志文章
  • A rapid HPLC method for monitoring plasma levels of caffeine and theophylline using solid phase extraction columns.

    abstract::A simple HPLC method for the determination of caffeine and theophylline in plasma is described. Separation of theobromine, paraxanthine, theophylline, beta-hydroxyethyltheophylline and caffeine is obtained using a mobile phase of 1% acetic acid/methanol (83:17, v/v) and a Waters Associates NOVA-PAK C18 column protecte...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328602300410

    authors: Pickard CE,Stewart AD,Hartley R,Lucock MD

    更新日期:1986-07-01 00:00:00

  • Effects of bilirubin and its photoisomers on direct bilirubin measurement using bilirubin oxidase.

    abstract::We examined the reactivity of human serum albumin-bound bilirubin and its photoisomers as substrates for a direct bilirubin assay using bilirubin oxidase. The reduction of (EZ)-cyclobilirubin reached 100% 5 min after addition of the enzyme at any pH tested (3.5-7.4) in 0.1 mol/L phosphate buffer, whereas the reduction...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456320003700404

    authors: Itoh S,Kusaka T,Imai T,Isobe K,Onishi S

    更新日期:2000-07-01 00:00:00

  • Comparison of the diagnostic utility of timed serial (slope) creatine kinase measurements with conventional serum tests in the early diagnosis of myocardial infarction.

    abstract::We compared the diagnostic utility of recently proposed slope assays for serum creatine kinase and creatine kinase-2 with the optimized decision threshold assays. The former approach has been claimed to be superior to any other single diagnostic technique. We show, by ROC curve and likelihood ratio analyses, that the ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800113

    authors: Leung FY,Griffith AP,Jablonsky G,Henderson AR

    更新日期:1991-01-01 00:00:00

  • Interference by haemoglobin with the cresolphthalein complexone method for serum calcium measurement.

    abstract::The spectral interference caused by haemoglobin in the calcium-cresolphthalein complexone reaction was investigated. The results show that the nature of the haemoglobin derivative in the reaction mixture influences the degree of interference; in turn, the derivative formed depends on the order in which the sample and ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329002700212

    authors: Corns CM

    更新日期:1990-03-01 00:00:00

  • The cardiovascular risk marker asymmetric dimethylarginine is elevated in asymptomatic, untreated HIV-1 infection and correlates with markers of immune activation and disease progression.

    abstract:BACKGROUND:As lifespan in HIV infection increases, cardiovascular disease has emerged as a cause of morbidity and mortality. Asymmetric dimethylarginine is an established marker of endothelial dysfunction and predicts cardiovascular events. The role of asymmetric dimethylarginine in HIV-related cardiovascular disease h...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563213505848

    authors: Hudson CL,Zemlin AE,Ipp H

    更新日期:2014-09-01 00:00:00

  • Evaluation of the diagnostic value of serum bile acid in the detection and functional assessment of liver diseases.

    abstract::The diagnostic usefulness of fasting total serum bile acids (SBA/F) in the detection of liver diseases and assessment of different aspects of hepatic function alteration was evaluated in 61 healthy subjects and 186 patients with liver disease. The value of SBA/F was compared with other routine tests. In 49 healthy sub...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328502200608

    authors: Cravetto C,Molino G,Biondi AM,Cavanna A,Avagnina P,Frediani S

    更新日期:1985-11-01 00:00:00

  • Urinary free catecholamines--diagnostic application of an HPLC technique to the investigation of neural crest tumours.

    abstract::Experience in the use of an in-house urinary free catecholamine assay for the investigation of possible neural crest tumours in a District General Hospital laboratory is described. Elevated excretion of catecholamines and vanillylmandelic acid was found in a number of cases including phaeochromocytoma and neuroblastom...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328702400512

    authors: Davidson DF

    更新日期:1987-09-01 00:00:00

  • Acidification and urine calcium: is it a preanalytical necessity?

    abstract:BACKGROUND:It has been suggested that for the accurate measurement of calcium in urine, samples must be collected into bottles containing acid. Acidification poses risks to both patients and laboratory staff. Here we reappraise whether acidification is a preanalytical necessity. METHODS:Twenty-four-hour urine samples ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2009.009027

    authors: Sodi R,Bailey LB,Glaysher J,Allars L,Roberts NB,Marks EM,Fraser WD

    更新日期:2009-11-01 00:00:00

  • Screening of bacteria in urine using luciferin-luciferase assay of microbial ATP: a comparative study.

    abstract::A total of 3227 urine specimens were analysed to investigate the applicability of a firefly luciferase assay of microbial adenosine triphosphate (ATP) for the rapid screening of bacteriuria in clinical specimens. Urine sediment, dipslide culture, and three plate cultures were also investigated in the majority of the u...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328201900605

    authors: Ruokonen A,Koskinen M,Leinonen M,Tiilikainen A,Vihko R

    更新日期:1982-11-01 00:00:00

  • A modified method for the estimation of galactose-1-phosphate.

    abstract::The measurement of galactose-1-phosphate has been advocated for monitoring galactosaemia. A radioenzymatic method is described in which red-cell haemolysates are incubated with radiolabelled uridine diphospho-glucose and exogenous galactose-1-phosphate uridyl transferase. Labelled glucose-1-phosphate is formed in prop...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328602300313

    authors: Dobbie JA,Holton JB

    更新日期:1986-05-01 00:00:00

  • Atypicality revisited: further data on the effectiveness of the Mahalanobis distance in Down's syndrome screening.

    abstract::Further data suggesting that assessment of atypicality may be a valuable addition to Down's syndrome screening is presented, based on results from 1521 unaffected pregnancies and 190 chromosomally abnormal pregnancies. For a 1% increase in false positive rates (over the Down's screening-related false positives), it is...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329703400314

    authors: Reynolds TM

    更新日期:1997-05-01 00:00:00

  • Assays for prolactin: guidelines for the provision of a clinical biochemistry service.

    abstract::This paper summarises the views of the authors on the provision of a prolactin assay service. We discuss the pathophysiology of prolactin secretion and the clinical indications that arise from that. We cover the rather complex issue of the definition of normal and elevated prolactin levels. From these considerations, ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/000456328602300603

    authors: Jeffcoate SL,Bacon RR,Beastall GH,Diver MJ,Franks S,Seth J

    更新日期:1986-11-01 00:00:00

  • Comparison of Amerlex, NML, and Ames total thyroxine and triiodothyronine radioimmunoassay kits.

    abstract::An evaluation of the Amerlex system for determination of total thyroxine (T4) and total triiodothyronine (T3) is described. The within- and between-batch precisions were acceptable, and analyses of quality control material and linearity studies demonstrated good accuracy at the clinical decision levels. The correlatio...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328201900208

    authors: Wilke TJ,Turnbull PA

    更新日期:1982-03-01 00:00:00

  • Correction and reporting of potassium results in haemolysed samples.

    abstract:BACKGROUND:Potassium is usually the most important analyte affected by in vitro haemolysis and the result obtained may falsely indicate or disguise a life-threatening abnormality and so give rise to inappropriate treatment. The purpose of the study was to provide a solution to the problem of reporting potassium on haem...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563053492739

    authors: Dimeski G,Clague AE,Hickman PE

    更新日期:2005-03-01 00:00:00

  • Radioimmunoassay of trypsin. A new aid in the assessment of pancreatic function.

    abstract::This review describes the development and application of a novel test to determine levels of human immunoreactive trypsin, an enzyme produced solely by the pancreas, in biological fluids. Being organ-specific, the assay of immunoreactive trypsin should be an ideal marker of pancreatic function, and this is supported b...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327901600131

    authors: Stagg BH,Wood TP

    更新日期:1979-05-01 00:00:00

  • Measurement of plasma lysophosphatidic acid concentration in healthy subjects: strong correlation with lysophospholipase D activity.

    abstract:BACKGROUND:Lysophosphatidic acid (LPA) plays important roles in a variety of biological responses, especially in the area of vascular biology, and the determination of its plasma concentration is believed to be important. Several mechanisms are known to be involved in the metabolism of LPA. METHODS:To identify factors...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2008.007242

    authors: Hosogaya S,Yatomi Y,Nakamura K,Ohkawa R,Okubo S,Yokota H,Ohta M,Yamazaki H,Koike T,Ozaki Y

    更新日期:2008-07-01 00:00:00

  • Serum binding of steroid tracers and its possible effects on direct steroid immunoassay.

    abstract::We studied the serum protein binding of 3H-labelled progesterone, oestradiol and testosterone, and five 125I-labelled analogues of these steroids. All tracers investigated appeared to be bound by proteins in every serum sample tested. The addition of blocking agents caused a substantial reduction in serum protein bind...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329503200609

    authors: Micallef JV,Hayes MM,Latif A,Ahsan R,Sufi SB

    更新日期:1995-11-01 00:00:00

  • The effect of potassium EDTA on the stability of parathyroid hormone in whole blood.

    abstract:BACKGROUND:The stability of parathyroid hormone (PTH) in whole blood has not been well characterized. Previous studies show EDTA plasma samples to be more stable than serum samples. METHODS:Blood from 17 haemodialysis patients and five healthy volunteers was collected into serum separator tubes (SSTs) and potassium ED...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456307780480927

    authors: English E,McFarlane I,Taylor KP,Halsall DJ

    更新日期:2007-05-01 00:00:00

  • Differential response of serum alkaline phosphatase and serum osteocalcin in Paget's osteosarcoma.

    abstract::Serum osteocalcin did not show any response to the onset of osteosarcoma in Paget's disease of bone whereas serum alkaline phosphatase increased rapidly. This suggests that osteocalcin is not useful in the diagnosis and management of Paget's osteosarcoma and does not reflect the same osteoblastic processes in bone as ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800216

    authors: Davie MW,Worsfold M,Sharp CA

    更新日期:1991-03-01 00:00:00

  • Measurement of plasma 1,25 dihydroxyvitamin D using a novel immunoextraction technique and immunoassay with iodine labelled vitamin D tracer.

    abstract::We evaluated a novel assay for the measurement of 1,25 dihydroxyvitamin D (1,25 (OH)2D). Immunoextraction of 1,25(OH)2D is performed using a mini column containing a solid-phase monoclonal antibody followed by radioimmunoassay (RIA) using an 125I-labelled 1,25(OH)2D derivative tracer and Sac-cell separation. The mean ...

    journal_title:Annals of clinical biochemistry

    pub_type: 临床试验,杂志文章

    doi:10.1177/000456329703400606

    authors: Fraser WD,Durham BH,Berry JL,Mawer EB

    更新日期:1997-11-01 00:00:00

  • A method for the determination of sex hormone binding globulin using Concanavalin A-sepharose.

    abstract::A binding assay for sex hormone binding globulin (SHBG) has been developed in which SHBG is saturated with tritiated dihydrotestosterone (DHT). Separation of bound and free DHT is achieved by using Concanavalin A-Sepharose as a solid phase matrix. The method is described and its performance, including linearity, impre...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329202900208

    authors: Whittaker JA,Cawood ML,Oakey RE

    更新日期:1992-03-01 00:00:00

  • Rapidly rule out acute myocardial infarction by combining copeptin and heart-type fatty acid-binding protein with cardiac troponin.

    abstract:BACKGROUND:The rapid exclusion of acute myocardial infarction in patients with chest pain can reduce the length of hospital admission, prevent unnecessary diagnostic work-up and reduce the burden on our health-care systems. The combined use of biomarkers that are associated with different pathophysiological aspects of ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215578189

    authors: Jacobs LH,van Borren M,Gemen E,van Eck M,van Son B,Glatz JF,Daniels M,Kusters R

    更新日期:2015-09-01 00:00:00

  • Antiphospholipid and antioangiogenic activity in females with recurrent miscarriage and antiphospholipid syndrome.

    abstract::Background Antiphospholipid syndrome is an autoimmune disease characterized by thrombosis, fetal losses and thrombocytopenia associated to antiphospholipid antibodies. They are directed to phospholipids, such as cardiolipins (anticardiolipin) and lupus anticoagulant or to complexes formed by phospholipids and protein ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563216672248

    authors: Pelusa HF,Pezzarini E,Basiglio CL,Musuruana J,Bearzotti M,Svetaz MJ,Daniele SM,Bottai H,Arriaga SM

    更新日期:2017-09-01 00:00:00

  • The implementation of a system for managing analytical quality in networked laboratories.

    abstract:BACKGROUND:In a network of laboratories analytical variability between instruments, even of the same type, may exist for reasons beyond the control of laboratory staff. Controlling variability is a prerequisite for the application of shared reference ranges and for ensuring the transferability of patient test results. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.010005

    authors: Jassam N,Lindsay C,Harrison K,Thompson D,Bosomworth MP,Barth JH

    更新日期:2011-03-01 00:00:00

  • The costing of tests in a laboratory for clinical chemistry and haematology.

    abstract::The total cost of a haematology and clinical chemistry laboratory, including external and hospital costs, was studied in a district general hospital in The Netherlands. The main conclusion is that the number of samples analysed is the most important cost-setting factor, but that reduction in the number of requests doe...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328402100206

    authors: Leijten JF,van der Geer F,Scholten MN,Goldschmidt HM

    更新日期:1984-03-01 00:00:00

  • Enzyme activities of the mitochondrial energy generating system in skeletal muscle tissue of preterm and fullterm neonates.

    abstract::Quadriceps muscle specimens from autopsy of 28 neonates (gestational age 25-42 weeks) were investigated to determine pyruvate and malate oxidation rates and several enzymes of the mitochondrial oxidative process. In general, the levels of all mitochondrial parameters measured, including carnitine levels, were lower in...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329202900604

    authors: Sperl W,Sengers RC,Trijbels JM,Ruitenbeek W,Doesburg WH,Smeitink JA,Kollée LA,Boon JM

    更新日期:1992-11-01 00:00:00

  • Pushing the limits of chemistry point-of-care testing for the management of patients under investigation for Ebola virus disease.

    abstract:BACKGROUND:With the recent outbreak in West Africa, hospitals worldwide have been developing protocols for suspect of cases of Ebola virus disease. Patients with Ebola virus disease present with a severe gastroenteritis leading to dehydration and electrolyte abnormalities and as such, routine chemistry analysis is esse...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215581651

    authors: LeBlanc JJ,Heinstein C,MacDonald J,Gallant R,Roberts C,Jackson C,Lou A,Nassar BA,Hatchette TF

    更新日期:2016-03-01 00:00:00

  • Why the assay of serum cystine by protein precipitation and chromatography should be abandoned.

    abstract::The higher bias of serum cystine estimations by a HPLC method compared with those by ion exchange techniques is shown to be largely due to differences in the sample preparation procedures of the two techniques. The ion exchange methods utilised sulphosalicylic acid serum protein precipitation and post-column ninhydrin...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328802500516

    authors: Cooper JD,Turnell DC,Green B,Wright DJ,Coombes EJ

    更新日期:1988-09-01 00:00:00

  • The effect of eccentric exercise on serum creatine kinase activity in different ethnic groups.

    abstract::Eccentric exercise causes release of muscle creatine kinase (CK) 3-4 days after exercise. Racial variation in basal serum CK has been reported but the reasons for this are unknown. We studied 30 subjects of different ethnic origin (Caucasian, Afro-Caribbean, Asian) before and after eccentric exercise. Basal serum CK w...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329603300407

    authors: Sherwood RA,Lambert A,Newham DJ,Wassif WS,Peters TJ

    更新日期:1996-07-01 00:00:00

  • Comparison of sample types for N-terminal pro-B-type natriuretic peptide measured on the Siemens Immulite 2500 and Dimension Vista LOCI methods.

    abstract:BACKGROUND:Measurement of serum natriuretic peptides is recommended in patients with suspected heart failure. Assays for N-terminal pro-B-type natriuretic peptide (NT-proBNP) are available on several platforms and can be measured in serum or heparinized plasma. Siemens Healthcare Diagnostics do not recommend the use of...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2012.012053

    authors: Peake RW,Turner HE,Leaper W,Deans KA,Hannah A,Croal BL

    更新日期:2012-09-01 00:00:00