Neck-bridge device for endovascular treatment of wide-neck bifurcation aneurysms: initial experience.

Abstract:

PURPOSE:To report the authors' initial experience in treating patients with wide-neck aneurysms with assistance from a recently developed neck-bridge device (TriSpan; Target Therapeutics/Boston Scientific, Fremont, Calif). MATERIALS AND METHODS:Twenty-five patients were examined. Aneurysms were most frequently at the basilar bifurcation (n = 19). Sixteen aneurysms were treated electively: six aneurysms that recurred after coil-only embolization and 10 nontreated aneurysms (including four that had failed coil-only embolization). Nine aneurysms were treated acutely following subarachnoid hemorrhage. All lesions except one had a wide neck. A dual-catheter technique was used in 23 patients. Immediate angiographic results, technical incidents, and complications were recorded. Follow-up angiography was performed in 16 patients. Clinical follow-up ranged from 1 to 12 months. RESULTS:Neck-bridge device-assisted coil packing was successfully performed in 23 lesions, with complete obliteration in three, residual necks in 13, and a minimal residual sac in seven patients. Parent vessel protection failed, with coil protrusion and arterial occlusion, in one of these patients. Other complications that were not directly related to use of the neck-bridge device included retroperitoneal hematoma, rebleeding, coil perforation, and transient embolic arterial occlusion. One patient died of vasospasm and heart failure. Follow-up angiography revealed complete obliteration in four, a residual neck in one, a persistent residual sac in four, and recurrent aneurysm in seven patients. One patient had a small occipital infarction 5 weeks after treatment. CONCLUSION:The described neck-bridge device is useful for assisting coil embolization of wide-neck bifurcation aneurysms.

journal_name

Radiology

journal_title

Radiology

authors

Raymond J,Guilbert F,Roy D

doi

10.1148/radiol.2212010474

subject

Has Abstract

pub_date

2001-11-01 00:00:00

pages

318-26

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

221

pub_type

杂志文章
  • In vivo functional and anatomic imaging for assessment of in vivo gene transfer.

    abstract:PURPOSE:To assess whether a combination of in vivo anatomic and functional imaging can help quantify expression of somatostatin receptor type 2 (SSTR2)-based reporters after in vivo gene transfer. MATERIALS AND METHODS:All animal experiments were approved by an institutional animal care and use committee. Six nude mic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2531081825

    authors: Singh SP,Yang D,Ravoori M,Han L,Kundra V

    更新日期:2009-09-01 00:00:00

  • Diagnostic Algorithm to Differentiate Benign Atypical Leiomyomas from Malignant Uterine Sarcomas with Diffusion-weighted MRI.

    abstract::Background Improving the differentiation of uterine sarcomas from atypical leiomyomas remains a clinical challenge and is needed to avoid inappropriate surgery. Purpose To develop a diagnostic algorithm including diffusion-weighted MRI criteria to differentiate malignant uterine sarcomas from benign atypical leiomyoma...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020191658

    authors: Abdel Wahab C,Jannot AS,Bonaffini PA,Bourillon C,Cornou C,Lefrère-Belda MA,Bats AS,Thomassin-Naggara I,Bellucci A,Reinhold C,Fournier LS

    更新日期:2020-11-01 00:00:00

  • Skin reactions with iocetamic acid.

    abstract::Four cases of severe skin reactions to the use of iocetamic acid as a contrast medium are reported. Although the incidence of this type of reaction was relatively small (1.8%), its severity induced the authors to discontinue the use of this medium. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.2.301

    authors: Janower ML,Hannon MA

    更新日期:1976-02-01 00:00:00

  • Focal liver tumors: characterization with 3D perflubutane microbubble contrast agent-enhanced US versus 3D contrast-enhanced multidetector CT.

    abstract:PURPOSE:To investigate the potential application of contrast material-enhanced three-dimensional (3D) ultrasonography (US), as compared with contrast-enhanced 3D computed tomography (CT), for characterization of focal liver tumors. MATERIALS AND METHODS:Institutional review board approval and informed patient consent ...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2511081324

    authors: Luo W,Numata K,Morimoto M,Kondo M,Takebayashi S,Okada M,Morita S,Tanaka K

    更新日期:2009-04-01 00:00:00

  • Maximum Standardized Uptake Value of (99m)Tc Hydroxymethylene Diphosphonate SPECT/CT for the Evaluation of Temporomandibular Joint Disorder.

    abstract::Purpose To evaluate the diagnostic accuracy of the quantitative parameter standardized uptake value (SUV) at single photon emission computed tomography (SPECT)/computed tomography (CT) for the evaluation of temporomandibular joint (TMJ) disorder (TMD). Materials and Methods This study was approved by the institutional...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016152294

    authors: Suh MS,Lee WW,Kim YK,Yun PY,Kim SE

    更新日期:2016-09-01 00:00:00

  • Prostate cancer: arterial infusion chemotherapy and alteration of intrapelvic blood flow.

    abstract::Twenty-one patients with prostate cancer underwent intermittent arterial infusion chemotherapy with an implanted reservoir and alteration of the intrapelvic blood flow. One internal iliac artery was embolized with steel coils so that the drugs would perfuse throughout the tumor through a single tube. Angiography perfo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.3.1438780

    authors: Nakamura K,Takashima S,Nakatsuka H,Onoyama Y

    更新日期:1992-12-01 00:00:00

  • Liver metabolite concentrations measured with 1H MR spectroscopy.

    abstract:PURPOSE:To determine the feasibility of measuring choline and glycogen concentrations in normal human liver in vivo with proton (hydrogen 1 [1H]) magnetic resonance (MR) spectroscopy. MATERIALS AND METHODS:Signed consent to participate in an institutional review board-approved and HIPAA-compliant study was obtained fr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12112344

    authors: Ouwerkerk R,Pettigrew RI,Gharib AM

    更新日期:2012-11-01 00:00:00

  • Radiographic features of gastrointestinal graft-vs.-host disease.

    abstract::Five patients underwent bone-marrow transplantation, and graft-vs.-host disease (GVHD) developed. Radiographic features are described. Three patients showed an abrupt transition at the jejuno-ileal junction from normal small bowel to ileal loops which were narrowed, tubular, separated, edematous, and, generally, witho...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.138.2.7005940

    authors: Rosenberg HK,Serota FT,Koch P,Borden S 4th,August CS

    更新日期:1981-02-01 00:00:00

  • Evaluation of Quantitative PET/MR Enterography Biomarkers for Discrimination of Inflammatory Strictures from Fibrotic Strictures in Crohn Disease.

    abstract:PURPOSE:To retrospectively evaluate positron emission tomography (PET)/magnetic resonance (MR) enterography for the differentiation of fibrotic strictures from inflammatory strictures in patients with Crohn disease. MATERIALS AND METHODS:This HIPAA-compliant retrospective study was approved by the institutional review...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150566

    authors: Catalano OA,Gee MS,Nicolai E,Selvaggi F,Pellino G,Cuocolo A,Luongo A,Catalano M,Rosen BR,Gervais D,Vangel MG,Soricelli A,Salvatore M

    更新日期:2016-03-01 00:00:00

  • Fetal cerebral ventriculomegaly: misidentification of the true medial boundary of the ventricle at US.

    abstract:PURPOSE:To investigate the implications of mistaking the medial surface of the cerebral hemisphere for the medial wall of the lateral ventricle at antenatal ultrasonography (US) and to identify US clues that might help avoid this interpretive error. MATERIALS AND METHODS:In 50 second- and third-trimester fetuses, a di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.3.9393540

    authors: Hertzberg BS,Kliewer MA,Bowie JD

    更新日期:1997-12-01 00:00:00

  • A helpful technique for difficult urethral catheterizations in boys for voiding cystourethrography.

    abstract::A simple technique used to catheterize boys for voiding cystourethrography, using a feeding catheter while the urethra is distended by a saline solution is described. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.2.7367650

    authors: Lorenzo RL,Bradford BF

    更新日期:1980-05-01 00:00:00

  • Computerized bone densitometric analysis: operator-dependent errors.

    abstract:PURPOSE:To determine the nature and relative frequency of operator-dependent data analysis errors in dual x-ray absorptiometry. MATERIALS AND METHODS:Over 40 months, 2,528 dual x-ray absorptiometric examinations of the forearm, femoral neck, and lumbar spine were performed by 11 technologists by using standard techniq...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.211.2.r99ma55467

    authors: Staron RB,Greenspan R,Miller TT,Bilezikian JP,Shane E,Haramati N

    更新日期:1999-05-01 00:00:00

  • Pheochromocytoma and the normal adrenal medulla: improved visualization with I-123 MIBG scintigraphy.

    abstract::The radiopharmaceutical iodine 131 metaiodobenzylguanidine (I-131 MIBG) has been shown to locate pheochromocytomas scintigraphically with a false-negative rate of approximately 13%. To improve image quality and reduce the false-negative rate, I-123 was examined as a radioactive label for MIBG, as it has many advantage...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001380

    authors: Lynn MD,Shapiro B,Sisson JC,Beierwaltes WH,Meyers LJ,Ackerman R,Mangner TJ

    更新日期:1985-06-01 00:00:00

  • Mesenteric circulation: three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique.

    abstract::To evaluate the mesenteric circulation with magnetic resonance (MR) angiography, the authors examined 16 individuals (12 patients, four volunteers) with a gadolinium-enhanced, breath-hold, fat-saturated, multiecho, three-dimensional, gradient-echo sequence. Twenty examinations were performed. Grades of 3 or 4 (on a fi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.1.8988220

    authors: Shirkhoda A,Konez O,Shetty AN,Bis KG,Ellwood RA,Kirsch MJ

    更新日期:1997-01-01 00:00:00

  • Mesial temporal sclerosis: diagnosis with fluid-attenuated inversion-recovery versus spin-echo MR imaging.

    abstract:PURPOSE:To compare the accuracy of a fluid-attenuated inversion-recovery (FLAIR) sequence with that of a conventional double spin-echo (SE) sequence in the identification of increased signal intensity of the hippocampus in mesial temporal sclerosis (MTS). MATERIALS AND METHODS:Three blinded reviewers independently gra...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668780

    authors: Jack CR Jr,Rydberg CH,Krecke KN,Trenerry MR,Parisi JE,Rydberg JN,Cascino GD,Riederer SJ

    更新日期:1996-05-01 00:00:00

  • Mucocele of the cystic duct remnant in eight liver transplant recipients: findings at cholangiography, CT, and US.

    abstract::The case histories and radiologic studies of eight liver transplant recipients who developed a mucocele of the allograft cystic duct remnant were retrospectively evaluated. All patients had clinical and/or laboratory evidence of biliary obstruction or cholangitis from 2 weeks to 3.3 years following transplantation. Ch...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.3.2243970

    authors: Zajko AB,Bennett MJ,Campbell WL,Koneru B

    更新日期:1990-12-01 00:00:00

  • Assessment of incontinence with intraurethral US: preliminary results.

    abstract::To explore the usefulness of intraluminal ultrasound (US) for diagnostic imaging of the female urethra, 22 female patients with different degrees of urinary incontinence and 10 female patients with normal continence underwent examination by means of a 20-MHz intravascular US system. Contiguous sections were used for t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.187.1.8451400

    authors: Klein HM,Kirschner-Hermanns R,Lagunilla J,Günther RW

    更新日期:1993-04-01 00:00:00

  • An analog patient model derived from computed tomograms for three-dimensional radiotherapy planning.

    abstract::An analog model of the part of a patient's body containing a tumor is constructed by drawing anatomical contours obtained from computed tomograms on a set of transparent plastic sheets. The coverage of radiotherapy fields in the patient is visualized in three dimensions using the model and the light beam from the radi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.1.7384510

    authors: Tatcher M,Elgrabli S,Kuten A,Kleinhaus U

    更新日期:1980-07-01 00:00:00

  • Depiction of transplant renal vascular anatomy and complications: unenhanced MR angiography by using spatial labeling with multiple inversion pulses.

    abstract:PURPOSE:To evaluate the ability to depict anatomy and complications of renal vascular transplant with unenhanced magnetic resonance (MR) angiography with spatial labeling with multiple inversion pulses (SLEEK) and to compare the results with color Doppler (CD) ultrasonography (US), digital subtraction angiography (DSA)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14131800

    authors: Tang H,Wang Z,Wang L,Hu X,Wang Q,Li Z,Li J,Meng X,Wang Y,Hu D

    更新日期:2014-06-01 00:00:00

  • Tunneled central venous access catheter placement in the pediatric population: comparison of radiologic and surgical results.

    abstract:PURPOSE:To compare the success and infection rates of radiologic placement with those of surgical placement of tunneled central venous access catheters (TCVACs) in infants and small children. MATERIALS AND METHODS:In 17 pediatric patients, TCVACs were placed with vascular access under ultrasound or fluoroscopic guidan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.1.8208950

    authors: Nosher JL,Shami MM,Siegel RL,DeCandia M,Bodner LJ

    更新日期:1994-07-01 00:00:00

  • Aortic dissection: magnetic resonance imaging.

    abstract::Fifteen patients with suspected or known aortic dissection were imaged with magnetic resonance (MR). Thirteen of these patients were eventually shown to have dissection. In most instances the diagnosis was established by aortography and/or computed tomography (CT) prior to the MR study. Surgical proof (6/13) and/or ao...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.2.3983390

    authors: Amparo EG,Higgins CB,Hricak H,Sollitto R

    更新日期:1985-05-01 00:00:00

  • Pulmonary embolism: interobserver agreement in the interpretation of conventional angiographic and DSA images in patients with nondiagnostic lung scan results.

    abstract:PURPOSE:To assess interobserver agreement in the interpretation of digital subtraction angiographic (DSA) images and conventional angiograms in patients with nondiagnostic lung scans. MATERIALS AND METHODS:One hundred thirty of 397 consecutive patients (65 men, 65 women; mean age, 57 years; age range, 18-92 years) in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.3.8628860

    authors: van Beek EJ,Bakker AJ,Reekers JA

    更新日期:1996-03-01 00:00:00

  • Improved MR venography: use of fast short inversion time inversion-recovery technique in evaluation of venous angiomas.

    abstract::Eleven patients (five female and six male, aged 6-67 years) with venous angiomas underwent axial and coronal T1-weighted and fast short inversion time inversion-recovery (STIR) magnetic resonance (MR) imaging to assess the full extent of the malformations. Images were assessed subjectively by the authors in a nonblind...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.3.7863000

    authors: Saks AM,Paterson FC,Irvine AT,Ayers BA,Burnand KG

    更新日期:1995-03-01 00:00:00

  • Nonsurgical treatment of arteriovenous malformations of the trunk and limb by transcatheter arterial embolization.

    abstract::Two patients with large arteriovenous malformations (AVM) were successfully treated by transcatheter selective arterial embolization with Gelfoam. An extensive lumbar retroperitoneal acquired AVM was markedly reduced, eliminating any clinical evidence of a persistent left-to-right shunt. A large localized congenital A...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.609

    authors: Stanley RJ,Cubillo E

    更新日期:1975-06-01 00:00:00

  • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose.

    abstract:PURPOSE:To show that prospective electrocardiographically (ECG)-triggered coronary computed tomographic (CT) angiography (hereafter, prospective CT angiography) is at least as effective as retrospective ECG-gated coronary CT angiography (hereafter, retrospective CT angiography). MATERIALS AND METHODS:Institutional rev...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2482071804

    authors: Hirai N,Horiguchi J,Fujioka C,Kiguchi M,Yamamoto H,Matsuura N,Kitagawa T,Teragawa H,Kohno N,Ito K

    更新日期:2008-08-01 00:00:00

  • Carotid artery invasion by head and neck masses: prediction with MR imaging.

    abstract:PURPOSE:To determine the value of magnetic resonance (MR) imaging in predicting resectability of head and neck neoplasms around the carotid arteries. MATERIALS AND METHODS:Forty-nine patients (28 male patients and 21 female patients aged 17-79 years; mean, 57.3 years) with head and neck masses and clinical evidence of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.3.7754000

    authors: Yousem DM,Hatabu H,Hurst RW,Seigerman HM,Montone KT,Weinstein GS,Hayden RE,Goldberg AN,Bigelow DC,Kotapka MJ

    更新日期:1995-06-01 00:00:00

  • Physical and clinical evaluation of new high-strip-density radiographic grids.

    abstract::The imaging performance of new high-strip-density (HSD) grids having 57 lines/cm was compared with that of conventional low-strip-density (LSD) grids having 33 or 40 lines/cm. The unique advantage of HSD grids is that, under most standard radiographic conditions, the grid lines are not noticeable on the final image, e...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.147.2.6340160

    authors: Doi K,Frank PH,Chan HP,Vyborny CJ,Makino S,Iida N,Carlin M

    更新日期:1983-05-01 00:00:00

  • Screening interval breast cancers: mammographic features and prognosis factors.

    abstract:PURPOSE:To review the mammographic features of screening interval breast cancers and to compare the tumor size, histologic grade, and lymph node involvement with those in screening-detected and unscreened symptomatic cancers. MATERIALS AND METHODS:Screening mammography was performed in 72,773 women aged 50-64 years. N...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.3.8638010

    authors: Burrell HC,Sibbering DM,Wilson AR,Pinder SE,Evans AJ,Yeoman LJ,Elston CW,Ellis IO,Blamey RW,Robertson JF

    更新日期:1996-06-01 00:00:00

  • Hepatocarcinogenesis: multistep changes of drainage vessels at CT during arterial portography and hepatic arteriography--radiologic-pathologic correlation.

    abstract:PURPOSE:To clarify the changes that occur in drainage vessels of dysplastic nodules and hepatocellular carcinoma (HCC) during hepatocarcinogenesis by using computed tomography (CT) during arterial portography (CTAP) and CT during hepatic arteriography (CTHA), with histologic findings as the reference standard. MATERIA...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2522081414

    authors: Kitao A,Zen Y,Matsui O,Gabata T,Nakanuma Y

    更新日期:2009-08-01 00:00:00

  • Primary advanced and local recurrent head and neck tumors: effective management with interstitial thermal radiation therapy.

    abstract::Thirty-seven patients with 18 primary advanced or persistent, 16 local recurrent, and three local metastatic tumors of the head and neck were treated with a combination of interstitial low-dose iridium-192 radiation therapy and interstitial 915-MHz microwave hyperthermia supplemented by external radiation therapy. Twe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.1.2353100

    authors: Seegenschmiedt MH,Sauer R,Fietkau R,Karlsson UL,Brady LW