CT colonography: multiobserver diagnostic performance.

Abstract:

PURPOSE:To prospectively evaluate multiobserver diagnostic performance and reader agreement for colorectal polyp detection in a well-characterized cohort of patients with increased number of polyps, compared with an average-risk patient, with colonoscopy as the reference standard. MATERIALS AND METHODS:A cohort of 70 patients suspected of having polyps was examined with spiral computed tomographic (CT) colonography, with colonoscopy performed the same day. After air insufflation per rectum, supine and prone images were obtained with single-detector row CT (5-mm collimation, 8-mm table increment, 2-mm reconstruction interval). Images were analyzed independently by four experienced abdominal radiologists using two-dimensional multiplanar reformation followed by selective use of three-dimensional endoscopic volume-rendered images. Data were analyzed both per polyp and per patient. RESULTS:Analysis per polyp demonstrated a pooled sensitivity of 0.68 for lesions 10 mm or larger (n = 40), with 75% agreement among the four readers. Analysis per patient demonstrated improved detection and agreement, with a pooled sensitivity of 0.88 for patients with polyps or cancers 10 mm or larger (n = 28), with 94% agreement. When sensitivity and receiver operating characteristic analyses were analyzed per polyp size threshold, results among readers converged and peaked at polyp diameters of approximately 10 mm. CONCLUSION:In this patient cohort, diagnostic performance and interobserver agreement with single-detector row CT colonography was sufficient for detection of patients with lesions 10 mm or larger, with more variable results for smaller polyps.

journal_name

Radiology

journal_title

Radiology

authors

McFarland EG,Pilgram TK,Brink JA,McDermott RA,Santillan CV,Brady PW,Heiken JP,Balfe DM,Weinstock LB,Thyssen EP,Littenberg B

doi

10.1148/radiol.2252011625

subject

Has Abstract

pub_date

2002-11-01 00:00:00

pages

380-90

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

225

pub_type

杂志文章
  • Hemochromatosis of the pituitary gland: MR imaging.

    abstract::Magnetic resonance imaging of the pituitary gland in a patient with secondary hemochromatosis is described. On T1-weighted images, the anterior lobe had almost no signal intensity, and only the high-signal posterior lobe was seen. These findings are compatible with the distribution of iron deposition and clinical symp...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380960

    authors: Fujisawa I,Morikawa M,Nakano Y,Konishi J

    更新日期:1988-07-01 00:00:00

  • Renal arterial rupture complicating transluminal angioplasty: successful conservative management.

    abstract::Vessel rupture complicating transluminal angioplasty is an uncommon event, especially in the renal artery. The authors report such a case, which was treated with immediate balloon tamponade and did not require surgical intervention. Possible causes and appropriate management are discussed, as well as the need for repo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.174-3-983

    authors: Ashenburg RJ,Blair RJ,Rivera FJ,Weigele JB

    更新日期:1990-03-01 00:00:00

  • Effects of a program to train radiologic technologists to identify abnormalities on mammograms.

    abstract:PURPOSE:To assess whether radiologic technologists could be successfully trained to identify abnormalities on mammograms. MATERIALS AND METHODS:Eight radiologic technologists from two different institutions took a pretest, underwent an 8-hour training course followed by a period of preceptorship, and then took a postt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.1.7997550

    authors: Bassett LW,Hollatz-Brown AJ,Bastani R,Pearce JG,Hirji K,Chen L

    更新日期:1995-01-01 00:00:00

  • Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT.

    abstract:PURPOSE:To investigate the effect of different iodine concentrations of contrast material on aortic and hepatic enhancement and the detectability of hypervascular hepatocellular carcinoma (HCC) with multi-detector row computed tomography (CT) and a uniphasic contrast material injection technique. MATERIALS AND METHODS...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiol.2243011188

    authors: Awai K,Takada K,Onishi H,Hori S

    更新日期:2002-09-01 00:00:00

  • Posttraumatic arterial priapism in children: management with embolization.

    abstract:PURPOSE:To evaluate selective embolization for management of posttraumatic priapism in preadolescent boys and color Doppler sonography for diagnosis of the causative lesion and for planning embolization. MATERIALS AND METHODS:Five preadolescent boys with posttraumatic priapism underwent selective angiography and embol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784590

    authors: Miller SF,Chait PG,Burrows PE,Steckler RE,Khoury AE,McLorie GA,Connolly BL,Pereira JK

    更新日期:1995-07-01 00:00:00

  • Diverticular disease: imaging with post-double-contrast sigmoid flush.

    abstract::In a prospective study, the effect of infusion of a low-density contrast material was evaluated as an adjunct to high-density, double-contrast imaging of the sigmoid colon. After double-contrast barium enema (DCBE) study, 52 consecutive patients with sigmoid diverticulosis received an additional 500-750-mL enema eithe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380980

    authors: Lappas JC,Maglinte DD,Kopecky KK,Cockerill EM,Lehman GA

    更新日期:1988-07-01 00:00:00

  • Hepatic hemangiomas and malignant tumors: improved differentiation with heavily T2-weighted conventional spin-echo MR imaging.

    abstract:PURPOSE:To determine whether hemangiomas and malignant tumors can be better differentiated at 1.5-T magnetic resonance imaging with use of more heavily T2-weighted conventional spin-echo sequences. MATERIALS AND METHODS:Eighty-three patients with focal liver lesions (50 malignant tumors, 24 hemangiomas, nine cysts) la...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.1.8090920

    authors: McFarland EG,Mayo-Smith WW,Saini S,Hahn PF,Goldberg MA,Lee MJ

    更新日期:1994-10-01 00:00:00

  • Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing.

    abstract:PURPOSE:To evaluate a percutaneous pulmonary embolism (PE) thrombectomy catheter that aspirates, macerates, and removes thrombus. MATERIALS AND METHODS:Nine in vitro tests were performed by using porcine thrombi at a PE test station that provides continuous fluid output of 2 L/min at a pressure of 50 mmHg. Macroemboli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041287

    authors: Kucher N,Windecker S,Banz Y,Schmitz-Rode T,Mettler D,Meier B,Hess OM

    更新日期:2005-09-01 00:00:00

  • Clinically isolated syndrome suggestive of multiple sclerosis: voxelwise regional investigation of white and gray matter.

    abstract:PURPOSE:To quantify white matter (WM) and gray matter (GM) damage in patients who presented with clinically isolated syndrome (CIS), which is suggestive of multiple sclerosis (MS), by combining volume-based morphometry (VBM) and tract-based spatial statistics (TBSS). MATERIALS AND METHODS:This prospective HIPAA-compli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2541090817

    authors: Raz E,Cercignani M,Sbardella E,Totaro P,Pozzilli C,Bozzali M,Pantano P

    更新日期:2010-01-01 00:00:00

  • Clostridium-produced gas gangrene of the colon.

    abstract::A case of radiologically demonstrable gas gangrene of the colon was proved pathologically to be caused by C. perfringens. The case was radiologically indistinguishable from that of bowel infarction. When intramural gas is seen in patients with the symptoms of toxemia but without the bloody diarrhea associated with bow...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.1.26

    authors: Rudikoff JC

    更新日期:1977-07-01 00:00:00

  • Absolute speeds of screen-film systems and their absorbed-energy constants.

    abstract::Absolute speeds (mR-1) of screen-film systems were determined accurately and precisely from ten independent measurements over a six month period at several beam qualities that included both scatter and scatter-free conditions. The absorbed x-ray energies in the screens that yielded a net film density of 1.0 were obtai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.1.6701320

    authors: Kodera Y,Doi K,Chan HP

    更新日期:1984-04-01 00:00:00

  • Choledocholithiasis: treatment with extracorporeal shock wave lithotripsy.

    abstract::In a patient with choledocholithiasis, a duodenal diverticulum precluded endoscopic retrograde bile duct cannulation. A transhepatic catheter was used to opacify the bile ducts and to guide the endoscopic sphincterotome into the major duodenal papilla. Because limited sphincterotomy did not allow extraction or spontan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.2.3116600

    authors: Becker CD,Fache JS,Gibney RG,Scudamore CH,Burhenne HJ

    更新日期:1987-11-01 00:00:00

  • Cartilage quality assessment by using glycosaminoglycan chemical exchange saturation transfer and (23)Na MR imaging at 7 T.

    abstract:PURPOSE:To compare a glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging method, which enables sampling of the water signal as a function of the presaturation offset (z-spectrum) at 13 points in clinically feasible imaging times, with sodium 23 ((23)Na) magnetic resonance (MR) imaging in patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101841

    authors: Schmitt B,Zbýn S,Stelzeneder D,Jellus V,Paul D,Lauer L,Bachert P,Trattnig S

    更新日期:2011-07-01 00:00:00

  • Nonpalpable breast lesions: accuracy of prebiopsy mammographic diagnosis.

    abstract::Mammograms of 220 patients who underwent spot localization for removal of nonpalpable breast lesions were reviewed for accuracy of interpretation. Results of subsequent biopsy indicated malignancy in 77 cases. The interpretations of mammograms obtained before biopsy were incorrect in 71 cases (27 false-negative and 44...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.2.3659350

    authors: Hermann G,Janus C,Schwartz IS,Krivisky B,Bier S,Rabinowitz JG

    更新日期:1987-11-01 00:00:00

  • Percutaneous abscess drainage in Crohn disease: technical success and short- and long-term outcomes during 14 years.

    abstract:PURPOSE:To determine technical success with percutaneous abscess drainage (PAD) in patients with Crohn disease during 14 years. MATERIALS AND METHODS:Medical records of 32 patients with Crohn disease who underwent PAD from 1985 to 1999 were reviewed. Results of abscess drainage and nature of subsequent surgical proced...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2223010554

    authors: Gervais DA,Hahn PF,O'Neill MJ,Mueller PR

    更新日期:2002-03-01 00:00:00

  • Therapeutic blockade of arteries using compressed Ivalon.

    abstract::A new technique for embolization with compressed Ivalon plugs is described. Fourteen arteries--six renal, three splenic, two pulmonary, one left gastric, and two abdominal aortas--were occluded in six dogs. In one case of renal artery embolization, three plugs were used, and in one case of abdominal aorta embolization...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.3.7403540

    authors: Zollikofer C,Castaneda-Zuniga WR,Galliani C,Rysavy JA,Formanek A,Amplatz K

    更新日期:1980-09-01 00:00:00

  • Focal Liver Lesions: Computer-aided Diagnosis by Using Contrast-enhanced US Cine Recordings.

    abstract::Purpose To assess the performance of computer-aided diagnosis (CAD) systems and to determine the dominant ultrasonographic (US) features when classifying benign versus malignant focal liver lesions (FLLs) by using contrast material-enhanced US cine clips. Materials and Methods One hundred six US data sets in all subje...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017170365

    authors: Ta CN,Kono Y,Eghtedari M,Oh YT,Robbin ML,Barr RG,Kummel AC,Mattrey RF

    更新日期:2018-03-01 00:00:00

  • Step-wedge sensitometry.

    abstract::An aluminum step-wedge filter placed far from the film cassette provides the constant variation of subject contrast required for quantitative sensitometry while virtually eliminating scatter radiations. Attenuation curves made with this configuration are almost exponentially linear. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.3.820

    authors: Hale J,Bloch P

    更新日期:1978-09-01 00:00:00

  • Glioblastoma Multiforme Recurrence: An Exploratory Study of (18)F FPPRGD2 PET/CT.

    abstract:PURPOSE:To prospectively evaluate fluorine 18 ((18)F) 2-fluoropropionyl-labeled PEGylated dimeric arginine-glycine-aspartic acid (RGD) peptide (PEG3-E[c{RGDyk}]2) (FPPRGD2) positron emission tomography (PET) in patients with glioblastoma multiforme (GBM). MATERIALS AND METHODS:The institutional review board approved t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141550

    authors: Iagaru A,Mosci C,Mittra E,Zaharchuk G,Fischbein N,Harsh G,Li G,Nagpal S,Recht L,Gambhir SS

    更新日期:2015-11-01 00:00:00

  • Superior mesenteric artery embolization: an angiographic emergency.

    abstract::Eleven cases of superior mesenteric artery embolization are presented. The extent of bowel necrosis was found to be related to two major factors: the site of occlusion and the elapsed time between the onset of symptoms and definitive therapy. Angiography, available on an emergency basis, provides a definitive diagnosi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.625

    authors: Kaufman SL,Harrington DP,Siegelman SS

    更新日期:1977-09-01 00:00:00

  • Calcifications in breast biopsy specimens: discrepancies in radiologic-pathologic identification.

    abstract::To analyze the effectiveness and accuracy of the diagnostic process from screening mammography to final diagnosis at pathologic examination, the authors conducted a prospective study of 277 consecutive patients who underwent 291 mammographically directed biopsies of nonpalpable lesions. Of the 170 lesions that demonst...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.1.2006260

    authors: Stein MA,Karlan MS

    更新日期:1991-04-01 00:00:00

  • An assessment of RBE of Californium-252 for C57-Black/6 mouse fibrosarcoma by a precise afterloading technique.

    abstract::Afterloading techniques were developed for the in vivo assessment of the RBE of californium-252 with respect of radium-226 using a fibrosarcoma in mice. The afterloading holder positions sources so that the tumor is uniformly irradiated. Using the end points of tumor volumetric studies up to 150 days after irradiation...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.1.205

    authors: Moser FL,Lanzi LH,Mewissen DJ,Furedi EM,Rozenfeld M

    更新日期:1975-10-01 00:00:00

  • Gallium scanning as a screening test for inflammatory lesions.

    abstract::Of the 67-Ga scans obtained in 42 patients with fever and suspected inflammatory lesions, 17 were positive. In 9 patients the scans yielded information about localized inflammation not provided by previous studies. Four patients did not have an inflammatory lesion at the positive site. Ten of 13 abscesses or inflamed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.2.383

    authors: Teates CD,Hunter JG Jr

    更新日期:1975-08-01 00:00:00

  • Intracranial hemorrhage in asymptomatic neonates: prevalence on MR images and relationship to obstetric and neonatal risk factors.

    abstract:PURPOSE:To retrospectively evaluate the prevalence of neonatal intracranial hemorrhage (ICH) and its relationship to obstetric and neonatal risk factors. MATERIALS AND METHODS:Pregnant women were recruited for a prospective study of neonatal brain development; the study was approved by the institutional review board a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2422060133

    authors: Looney CB,Smith JK,Merck LH,Wolfe HM,Chescheir NC,Hamer RM,Gilmore JH

    更新日期:2007-02-01 00:00:00

  • The RSNA Pediatric Bone Age Machine Learning Challenge.

    abstract::Purpose The Radiological Society of North America (RSNA) Pediatric Bone Age Machine Learning Challenge was created to show an application of machine learning (ML) and artificial intelligence (AI) in medical imaging, promote collaboration to catalyze AI model creation, and identify innovators in medical imaging. Materi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018180736

    authors: Halabi SS,Prevedello LM,Kalpathy-Cramer J,Mamonov AB,Bilbily A,Cicero M,Pan I,Pereira LA,Sousa RT,Abdala N,Kitamura FC,Thodberg HH,Chen L,Shih G,Andriole K,Kohli MD,Erickson BJ,Flanders AE

    更新日期:2019-02-01 00:00:00

  • Gray-scale ultrasound detection of carotid body tumors. Report of 2 cases.

    abstract::Ultrasonography may be useful as a screening test for carotid body tumors before arteriography. Such tumors are seen as solid, well-circumscribed, weakly echogenic masses located at the carotid bifurcation. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.409

    authors: Gooding GA

    更新日期:1979-08-01 00:00:00

  • Carbon-fiber electrodes and leads for electrocardiography during MR imaging.

    abstract::In an effort to minimize distortion and artifacts on magnetic resonance images obtained with electrocardiographic (ECG) gating, the authors tested the use of ECG electrodes and leads made of carbon fiber. These materials caused no image degradation and, because the leads were reinforced with plastic, were less vulnera...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.3.2717770

    authors: van Genderingen HR,Sprenger M,de Ridder JW,van Rossum AC

    更新日期:1989-06-01 00:00:00

  • Duplication of the müllerian ducts and genitourinary malformations. Part II: analysis of malformations.

    abstract::Forty-seven females with duplication of the uterus and cervix were retrospectively studied to obtain a better understanding of the reasons for failure of fusion of the müllerian ducts by analyzing the associated genitourinary malformations. Thirty-one of the 47 patients had major genitourinary malformations that corre...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.4.6213980

    authors: Gilsanz V,Cleveland RH,Reid BS

    更新日期:1982-09-01 00:00:00

  • Shoulder arthrography: comparison of morbidity after use of various contrast media.

    abstract::This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.2.3966120

    authors: Hall FM,Goldberg RP,Wyshak G,Kilcoyne RF

    更新日期:1985-02-01 00:00:00

  • Preoperative staging of endometrial carcinoma: diagnostic effect of T2-weighted fast spin-echo MR imaging.

    abstract:PURPOSE:To evaluate the usefulness of T2-weighted fast spin-echo magnetic resonance (MR) imaging with a 512 x 256 matrix for assessment of the preoperative stage of endometrial carcinoma. MATERIALS AND METHODS:Twenty-eight women with histopathologically proved endometrial carcinoma underwent preoperative T2-weighted f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.2.9457210

    authors: Takahashi S,Murakami T,Narumi Y,Kurachi H,Tsuda K,Kim T,Enomoto T,Tomoda K,Miyake A,Murata Y,Nakamura H

    更新日期:1998-02-01 00:00:00