Choledocholithiasis: treatment with extracorporeal shock wave lithotripsy.

Abstract:

:In a patient with choledocholithiasis, a duodenal diverticulum precluded endoscopic retrograde bile duct cannulation. A transhepatic catheter was used to opacify the bile ducts and to guide the endoscopic sphincterotome into the major duodenal papilla. Because limited sphincterotomy did not allow extraction or spontaneous passage of the common duct stones, extracorporeal lithotripsy was performed. Following fragmentation, the stones passed spontaneously and without complications.

journal_name

Radiology

journal_title

Radiology

authors

Becker CD,Fache JS,Gibney RG,Scudamore CH,Burhenne HJ

doi

10.1148/radiology.165.2.3116600

subject

Has Abstract

pub_date

1987-11-01 00:00:00

pages

407-8

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

165

pub_type

杂志文章
  • Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing.

    abstract:PURPOSE:To evaluate a percutaneous pulmonary embolism (PE) thrombectomy catheter that aspirates, macerates, and removes thrombus. MATERIALS AND METHODS:Nine in vitro tests were performed by using porcine thrombi at a PE test station that provides continuous fluid output of 2 L/min at a pressure of 50 mmHg. Macroemboli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041287

    authors: Kucher N,Windecker S,Banz Y,Schmitz-Rode T,Mettler D,Meier B,Hess OM

    更新日期:2005-09-01 00:00:00

  • Nasopharyngeal angiofibromas: hazards of embolization.

    abstract::A systematic approach to the diagnosis and treatment of angiofibromas is presented. The distinction between true and false internal carotid supply to these tumors as well as identification of vascular anatomical variants that may represent potential hazards of embolization are emphasized. Areterial supply to the crani...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.1.6247740

    authors: Lasjaunias P

    更新日期:1980-07-01 00:00:00

  • Negative-mode soft-tissue xeroradiography.

    abstract::Positive-mode xeroradiography is an excellent method of visualizing soft-tissue structures in mammography and other procedures; however, toner deletions over a large area may preclude adequate delineation of the soft tissues near high-density structures such as bone. Use of the negative mode in the development cycle p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.689

    authors: Osterman FA Jr,Zeman GH,Rao GU,Gayler B,Kirk BG,James AE Jr

    更新日期:1977-09-01 00:00:00

  • Carotid artery hemodynamics: observing patient-specific changes with amlodipine and lisinopril by using MR imaging computation fluid dynamics.

    abstract:PURPOSE:To assess whether using magnetic resonance (MR) imaging combined with computational fluid dynamics (CFD) could reveal changes in common carotid artery (CCA) flow and wall shear stress (WSS) that might contribute to differences in CCA remodeling between amlodipine, a calcium channel blocker, and lisinopril, an a...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.10100788

    authors: Ariff BB,Glor FP,Crowe L,Xu XY,Vennart W,Firmin DN,Thom SM,Hughes AD

    更新日期:2010-12-01 00:00:00

  • Noninvasive breast cancer.

    abstract::Noninvasive breast cancer comprises two distinct entities, lobular carcinoma in situ (LCIS) and ductal carcinoma in situ (DCIS). The increased use of screening mammography has caused more cases of noninvasive breast cancer to be discovered. However, the increased detection of LCIS and DCIS has posed problems in patien...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.190.3.8115600

    authors: Rebner M,Raju U

    更新日期:1994-03-01 00:00:00

  • Cytotoxic and radiosensitizing effects of 5-thio-D-glucose on hypoxic cells.

    abstract::The effect of 5-thio-D-glucose on the viability and radiosensitivity of P815-X2 mouse mastocytoma cells was studied in vitro. By itself, this compound is specifically cytotoxic toward hypoxic cells; moreover, it sensitizes hypoxic cells to irradiation while it protects aerobic cells from radiation damage. These featur...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.1.201

    authors: Song CW,Clement JJ,Levitt SH

    更新日期:1977-04-01 00:00:00

  • Recombinant human tissue-type plasminogen activator for thrombolysis in peripheral arteries and bypass grafts.

    abstract::Recombinant human tissue-type plasminogen activator (rt-PA) was infused intraarterially at 0.1 mg/kg/h for 1-6 1/2 hours in 25 patients with lower extremity thromboembolic occlusions (13 thrombosed arteries, 12 thrombosed bypass grafts). Occlusion duration ranged from 1 hour to 21 days. Thrombolysis occurred in 23 of ...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.160.1.3086930

    authors: Risius B,Graor RA,Geisinger MA,Zelch MG,Lucas FV,Young JR,Grossbard EB

    更新日期:1986-07-01 00:00:00

  • Peripheral cholangiocarcinoma and clonorchiasis: CT findings.

    abstract::Sixteen patients with peripheral cholangiocarcinoma of the liver were examined with computed tomography (CT). None of the 16 patients presented with jaundice or had documented cirrhosis. On scans obtained both before and after the injection of contrast material, the tumors were depicted as low-attenuation masses in al...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.1.2843940

    authors: Choi BI,Park JH,Kim YI,Yu ES,Kim SH,Kim WH,Kim CY,Han MC

    更新日期:1988-10-01 00:00:00

  • Delineation of optic nerves and chiasm in close proximity to large suprasellar tumors with contrast-enhanced FIESTA MR imaging.

    abstract:PURPOSE:To evaluate whether contrast material-enhanced (CE) fast imaging employing steady-state acquisition (FIESTA) can depict the anterior optic pathways in patients with large suprasellar tumors. MATERIALS AND METHODS:Institutional review board approval was obtained. Twenty-eight patients with large suprasellar tum...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12111363

    authors: Watanabe K,Kakeda S,Yamamoto J,Watanabe R,Nishimura J,Ohnari N,Nishizawa S,Korogi Y

    更新日期:2012-09-01 00:00:00

  • Adrenal glands in patients with congenital renal anomalies: CT appearance.

    abstract::The CT appearance of the adrenal glands was investigated in 30 patients with congenital renal anomalies (17 cases of unilateral renal agenesis, 11 of inferior ectopy, and 2 of crossed fused ectopy). The ipsilateral adrenal was clearly identified in 83% of these patients; in all of them, the adrenal was a paraspinal di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.1.3975400

    authors: Kenney PJ,Robbins GL,Ellis DA,Spirt BA

    更新日期:1985-04-01 00:00:00

  • Use of Public Data to Target Variation in Providers' Use of CT and MR Imaging among Medicare Beneficiaries.

    abstract:PURPOSE:To examine geographic variation in providers' use of diagnostic imaging to identify potential targets for quality improvement initiatives after adjusting for imaging referral across hospital referral regions (HRRs). MATERIALS AND METHODS:Using two Centers for Medicare and Medicaid Services datasets, the author...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.15141964

    authors: Ip IK,Raja AS,Seltzer SE,Gawande AA,Joynt KE,Khorasani R

    更新日期:2015-06-01 00:00:00

  • Acute peripheral arterial occlusion: predictors of success in catheter-directed thrombolytic therapy.

    abstract:PURPOSE:To determine predictors of clot dissolution in patients undergoing catheter-directed urokinase thrombolysis for peripheral arterial occlusion (PAO). MATERIALS AND METHODS:The study included 103 patients with limb-threatening symptoms of embolism lasting 14 days or less and resulting from embolism (n = 20) or t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.2.7972780

    authors: Ouriel K,Shortell CK,Azodo MV,Guiterrez OH,Marder VJ

    更新日期:1994-11-01 00:00:00

  • Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality.

    abstract:PURPOSE:To determine the computed tomographic (CT) detector configuration, patient size, and image noise limitations that will result in acceptable image quality of 80-kV images obtained at abdominal dual-energy CT. MATERIALS AND METHODS:The Institutional Review Board approved this HIPAA-compliant retrospective study ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10092016

    authors: Guimarães LS,Fletcher JG,Harmsen WS,Yu L,Siddiki H,Melton Z,Huprich JE,Hough D,Hartman R,McCollough CH

    更新日期:2010-12-01 00:00:00

  • Fibroid-related menorrhagia: treatment with superselective embolization of the uterine arteries and midterm follow-up.

    abstract:PURPOSE:To prospectively evaluate the effectiveness and safety of selective embolization of the uterine arteries in the management of symptomatic uterine leiomyoma. MATERIALS AND METHODS:Eighty consecutive women (mean age, 44.7 years) with symptomatic uterine leiomyoma, none of whom desired future pregnancy, underwent...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.2.r00ma11428

    authors: Pelage JP,Le Dref O,Soyer P,Kardache M,Dahan H,Abitbol M,Merland JJ,Ravina JH,Rymer R

    更新日期:2000-05-01 00:00:00

  • Neuropsychologic correlates of brain white matter lesions depicted on MR images: 1921 Aberdeen Birth Cohort.

    abstract:PURPOSE:To examine relationships between brain white matter hyperintensities depicted at magnetic resonance (MR) imaging and performance on neuropsychologic tests in community-dwelling elderly adults. MATERIALS AND METHODS:The 1921 Aberdeen Birth Cohort is a subsample of survivors of the Scottish Mental Survey of 1932...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2211010086

    authors: Leaper SA,Murray AD,Lemmon HA,Staff RT,Deary IJ,Crawford JR,Whalley LJ

    更新日期:2001-10-01 00:00:00

  • Pheochromocytomas: detection with 18F DOPA whole body PET--initial results..

    abstract:PURPOSE:To evaluate fluorine 18 ((18)F) dihydroxyphenylalanine (DOPA) whole-body positron emission tomography (PET) as a biochemical imaging approach for detection of pheochromocytomas. MATERIALS AND METHODS:(18)F DOPA PET and magnetic resonance (MR) imaging were performed in 14 consecutive patients suspected of havin...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2222010622

    authors: Hoegerle S,Nitzsche E,Altehoefer C,Ghanem N,Manz T,Brink I,Reincke M,Moser E,Neumann HP

    更新日期:2002-02-01 00:00:00

  • Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine.

    abstract:PURPOSE:To evaluate resonant circuits as markers for magnetic resonance (MR) imaging-guided placement of nitinol stents. MATERIALS AND METHODS:The study was approved by the institutional animal research committee and complied with National Institutes of Health guidelines for care and use of laboratory animals. Resonan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2333031710

    authors: Kuehne T,Weiss S,Brinkert F,Weil J,Yilmaz S,Schmitt B,Ewert P,Lange P,Gutberlet M

    更新日期:2004-12-01 00:00:00

  • Thalamic resting-state functional networks: disruption in patients with mild traumatic brain injury.

    abstract:PURPOSE:To explore the neural correlates of the thalamus by using resting-state functional magnetic resonance (MR) imaging and to investigate whether thalamic resting-state networks (RSNs) are disrupted in patients with mild traumatic brain injury (MTBI). MATERIALS AND METHODS:This HIPAA-compliant study was approved b...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11110014

    authors: Tang L,Ge Y,Sodickson DK,Miles L,Zhou Y,Reaume J,Grossman RI

    更新日期:2011-09-01 00:00:00

  • Introducing the "golden oldies" of radiology.

    abstract::Online supplemental material is available for this article. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14142264

    authors: Kressel HY,Levine D

    更新日期:2015-01-01 00:00:00

  • A simple traction device for use in the radiology department.

    abstract::Portable sustained graded traction for control of the displaced cervical spine particularly for patients undergoing tomography or gas myelography, is described. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.826

    authors: Deeb ZL,Drayer BP,Rosenbaum AE

    更新日期:1977-12-01 00:00:00

  • Recurrent breast cancer: stereotaxic localization for fine-needle aspiration biopsy. Work in progress.

    abstract::The efficacy of stereotaxic localization for fine-needle aspiration biopsy in the detection of recurrent cancer manifested as calcifications on mammograms was evaluated in 43 patients that had been treated with local resection and radiation therapy. Six patients had malignant aspirates and one had an atypical aspirate...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.182.1.1727270

    authors: Mitnick JS,Vazquez MF,Roses DF,Harris MN,Schechter S

    更新日期:1992-01-01 00:00:00

  • Percutaneous transperitoneal lymph-node biopsy as a means of improving lymphographic diagnosis.

    abstract::Percutaneous transperitoneal fine-needle lymph-node biopsy was performed in 52 patients to establish a diagnosis of metastatic disease in nodal defects detected during lymphography. The procedure was found to be highly accurate, with few false-negatives and no false-positives. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.3.647

    authors: Macintosh PK,Thomson KR,Barbaric ZL

    更新日期:1979-06-01 00:00:00

  • Intestinal perforation. An infrequent complication of ventriculo-peritoneal shunts.

    abstract::Bowel perforation by ventriculo-peritoneal shunts occurred in two children with no abdominal symptoms. The diagnosis in each instance was confirmed by opacification of the colon in one child and the small bowel in the other via contrast medium injection of the distal shunt tubing. "Shuntograms" are recommended for all...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.3.701

    authors: Azimi F,Dinn WM,Naumann RA

    更新日期:1976-12-01 00:00:00

  • Inflammatory fibroid polyp of the colon simulating malignancy.

    abstract::The authors report an inflammatory fibroid polyp of the colon which simulated a tumor on the air-contrast barium-enema examination. Histological evaluation revealed the inflammatory nature of the polyp. These rare lesions can be radiographically indistinguishable from primary colon carcinoma. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6611950

    authors: Ferin P,Skucas J

    更新日期:1983-10-01 00:00:00

  • Azotemia: gadopentetate dimeglumine as contrast agent at digital subtraction angiography.

    abstract::In an azotemic patient with suspected renal artery stenosis, undiluted gadopentetate dimeglumine was administered in an aortic bolus to provide contrast at digital subtraction angiography of the aorta and renal arteries. The contrast material (5 mmol/mL) was power injected (rate, 15 mL/sec; total dose, 30 mL). Selecti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.2.8888260

    authors: Matchett WJ,McFarland DR,Russell DK,Sailors DM,Moursi MM

    更新日期:1996-11-01 00:00:00

  • CT-guided aspirations for the body: comparison of hand guidance with stereotaxis.

    abstract::Forty computed tomography (CT)-assisted aspirations performed with only hand guidance were prospectively compared with 40 performed with a CT body-stereotaxic system. Although there was no statistically significant difference in lesion size and path length between the two groups, use of stereotaxis compared with hand ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.2.3275980

    authors: Onik G,Cosman ER,Wells TH Jr,Goldberg HI,Moss AA,Costello P,Kane RA,Hoddick WI,Demas B

    更新日期:1988-02-01 00:00:00

  • Recurrent hepatocellular carcinoma: percutaneous radiofrequency ablation after hepatectomy.

    abstract:PURPOSE:To evaluate the therapeutic efficacy and safety of percutaneous radiofrequency (RF) ablation for recurrent hepatocellular carcinoma (HCC) in the liver after hepatectomy. MATERIALS AND METHODS:Forty-five patients with 53 recurrent HCC tumors in the liver underwent percutaneous RF ablation with ultrasonographic ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2301021182

    authors: Choi D,Lim HK,Kim MJ,Lee SH,Kim SH,Lee WJ,Lim JH,Joh JW,Kim YI

    更新日期:2004-01-01 00:00:00

  • Hyperacute thermal lesions: MR imaging evaluation of development in the brain.

    abstract:PURPOSE:To determine the natural time course of development of hyperacute thermal lesions in the brain. MATERIALS AND METHODS:Ten interstitial lesions were created in five rabbit brains with a radio-frequency probe; an electrode-tip temperature of 80 degrees C was maintained for 60 seconds. Continuous fast spin-echo m...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617870

    authors: Farahani K,Mischel PS,Black KL,De Salles AA,Anzai Y,Lufkin RB

    更新日期:1995-08-01 00:00:00

  • Radiation protection requirements for a whole-body CT scanner.

    abstract::Exposure values for a whole-body CT scanner, obtained from a room protection survey covering one month (119 patients), are reported. It was found that weekly exposures could be expected to be in the range of 350-750 mR/week for a daily load of 12 patients. The h.v.l. of gypsum board, lead, and plate glass at this radi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.3.825

    authors: Gross GP,McCullough EC

    更新日期:1977-03-01 00:00:00

  • Evaluation of Low-Contrast Detectability of Iterative Reconstruction across Multiple Institutions, CT Scanner Manufacturers, and Radiation Exposure Levels.

    abstract:PURPOSE:To compare image resolution from iterative reconstruction with resolution from filtered back projection for low-contrast objects on phantom computed tomographic (CT) images across vendors and exposure levels. MATERIALS AND METHODS:Randomized repeat scans of an American College of Radiology CT accreditation pha...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141260

    authors: Saiprasad G,Filliben J,Peskin A,Siegel E,Chen J,Trimble C,Yang Z,Christianson O,Samei E,Krupinski E,Dima A

    更新日期:2015-10-01 00:00:00