Computer-aided detection in digital mammography: comparison of craniocaudal, mediolateral oblique, and mediolateral views.

Abstract:

PURPOSE:To retrospectively compare the sensitivity of a computer-aided detection (CAD) system for depicting breast cancer in three digital mammographic views. MATERIALS AND METHODS:This study was conducted with institutional review board approval; informed consent was waived. A commercially available CAD system was applied to the craniocaudal, mediolateral oblique, and mediolateral digital mammographic views of 83 women (mean age, 48 years; range, 30-66 years) with 83 histologically proved breast cancers. Findings were 59 masses and 41 microcalcifications (17 lesions showed both findings; 42 lesions, mass only; and 24 lesions, microcalcification only). The paired t test was used to analyze sensitivity of the CAD system for the detection of cancer in these three mammographic views and in combinations of the views. RESULTS:The sensitivities of the CAD system were 92% (76 of 83) in the craniocaudal view, 83% (69 of 83) in the mediolateral oblique view, and 86% (71 of 83) in the mediolateral view; the differences were not significant (P = .07-.62). Sensitivity increased to 96% (80 of 83) in the craniocaudal plus mediolateral oblique views and to 99% (82 of 83) in the craniocaudal plus mediolateral oblique plus mediolateral views. For masses, the sensitivity of the CAD system was 76% (45 of 59) in the craniocaudal view and 75% (44 of 59) in the mediolateral oblique view and increased to 93% (55 of 59) when mediolateral oblique and craniocaudal views were combined (P < .001). For microcalcifications, sensitivity was 98% (40 of 41) in the craniocaudal view and 95% (39 of 41) in the mediolateral oblique view, and this increased to 100% (41 of 41) when the mediolateral oblique and craniocaudal views were combined (P = .31). CONCLUSION:The sensitivities of the CAD system were not significantly different among these three digital mammographic views. Sensitivity for depicting masses was significantly increased (P < .001) when the craniocaudal view was added to the mediolateral oblique view.

journal_name

Radiology

journal_title

Radiology

authors

Kim SJ,Moon WK,Cho N,Cha JH,Kim SM,Im JG

doi

10.1148/radiol.2413051145

subject

Has Abstract

pub_date

2006-12-01 00:00:00

pages

695-701

issue

3

eissn

0033-8419

issn

1527-1315

pii

241/3/695

journal_volume

241

pub_type

杂志文章
  • Locally advanced squamous cell carcinoma of the head and neck: CT texture and histogram analysis allow independent prediction of overall survival in patients treated with induction chemotherapy.

    abstract:PURPOSE:To determine if computed tomographic (CT) texture and histogram analysis measurements of the primary mass are independently associated with overall survival in patients with locally advanced squamous cell carcinoma of the head and neck who were previously treated with cisplatin, 5-fluorouracil, and docetaxel (T...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13130110

    authors: Zhang H,Graham CM,Elci O,Griswold ME,Zhang X,Khan MA,Pitman K,Caudell JJ,Hamilton RD,Ganeshan B,Smith AD

    更新日期:2013-12-01 00:00:00

  • Gastric polyps on routine double-contrast examination of the stomach.

    abstract::Gastric polyps were found in 38 patients in a series of 2,420 consecutive double-contrast studies of the upper gastrointestinal tract. The resulting incidence of 1.6% is four times the highest figure previously reported. Single polyps were usually located in the antrum, multiple polyps in the body of fundus. Two-third...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.1.7350630

    authors: Gordon R,Laufer I,Kressel HY

    更新日期:1980-01-01 00:00:00

  • The Kimray-Greenfield filter: evaluation by duplex real-time/pulsed Doppler ultrasound.

    abstract::The Kimray-Greenfield filter is a wire cage which is inserted into the inferior vena cava (IVC) to prevent thrombi originating in pelvic and leg veins from embolizing to the lungs. Duplex real-time/pulsed Doppler ultrasound was used to evaluate placement and function in 38 patients (46 examinations). Real-time examina...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.1.6856840

    authors: Pasto ME,Kurtz AB,Jarrell BE,Dubbins PA,Rifkin MD,Cole-Beuglet C,Baltarowich O,Goldberg BB

    更新日期:1983-07-01 00:00:00

  • Assessment of multiple sclerosis lesions with spherical harmonics: comparison of MR imaging and pathologic findings.

    abstract::Spherical harmonics (SH) were used to approximate the volume and three-dimensional geometry of multiple sclerosis (MS) lesions in deceased patients. The institutional ethical committee does not require its approval for studies involving pathologic specimens. Pathologic findings were used as the reference standard. In ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2353032071

    authors: Goldberg-Zimring D,Shalmon B,Zou KH,Azhari H,Nass D,Achiron A

    更新日期:2005-06-01 00:00:00

  • Cranial bone marrow in children: assessment of normal development with MR imaging.

    abstract::Magnetic resonance images of cranial bone marrow in 238 patients (246 examinations) less than 25 years old were reviewed to establish normal age-related standards. Bone marrow in the clivus and calvaria had uniformly low signal intensity (grade 1) on T1-weighted images in most infants less than 1 year old. The number ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.1.2928520

    authors: Okada Y,Aoki S,Barkovich AJ,Nishimura K,Norman D,Kjos BO,Brasch RC

    更新日期:1989-04-01 00:00:00

  • Computed tomography in the evaluation of musculoskeletal neoplasms.

    abstract::In a study of 62 musculoskeletal neoplasms, computed tomography contributed little to establishing tissue diagnosis. Its primary value lay in the assessment of intraosseous and/or extraosseous extent of disease. CT also established the presence or absence of disease in a small number of cases with clinically questiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.1.89

    authors: deSantos LA,Goldstein HM,Murray JA,Wallace S

    更新日期:1978-07-01 00:00:00

  • Manipulation of vena cava filters. Locked-catheter technique.

    abstract::A method is described for the rapid and easy manipulation of a Kimray-Greenfield vena cava filter beyond an obstructing eustachian valve. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.1.6689770

    authors: Glass TA,D'Souza VJ,Velasquez G,Formanek AG,Meredith J,Albertson D

    更新日期:1984-01-01 00:00:00

  • BI-RADS lexicon for US and mammography: interobserver variability and positive predictive value.

    abstract:PURPOSE:To retrospectively evaluate interobserver variability between breast radiologists by using terminology of the fourth edition of the Breast Imaging Reporting and Data System (BI-RADS) to categorize lesions on mammograms and sonograms and to retrospectively determine the positive predictive value (PPV) of BI-RADS...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2392042127

    authors: Lazarus E,Mainiero MB,Schepps B,Koelliker SL,Livingston LS

    更新日期:2006-05-01 00:00:00

  • Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconst

    abstract::Purpose To determine the effect of radiation dose and iterative reconstruction (IR) on noise, contrast, resolution, and observer-based detectability of subtle hypoattenuating liver lesions and to estimate the dose reduction potential of the IR algorithm in question. Materials and Methods This prospective, single-cente...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161736

    authors: Solomon J,Marin D,Roy Choudhury K,Patel B,Samei E

    更新日期:2017-09-01 00:00:00

  • Orthotopic pleural mesothelioma in mice: SPECT/CT and MR imaging with HER1- and HER2-targeted radiolabeled antibodies.

    abstract:PURPOSE:To evaluate the potential of anti-human epidermal growth factor receptor (HER)1- and anti-HER2-targeted radiolabeled antibodies and magnetic resonance (MR) imaging for imaging of orthotopic malignant pleural mesothelioma (MPM) in mouse models. MATERIALS AND METHODS:Animal studies with 165 mice were performed i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12121021

    authors: Nayak TK,Bernardo M,Milenic DE,Choyke PL,Brechbiel MW

    更新日期:2013-04-01 00:00:00

  • Angioplasty from the contralateral approach: use of a guiding catheter and coaxial angioplasty balloons.

    abstract::An 8-F guiding catheter has been developed for use with coaxial angioplasty balloon catheters in angioplasty of the femoral artery from the contralateral approach when antegrade puncture of the ipsilateral femoral artery is not possible. The catheter may be used for angioplasty of the femoral artery bifurcation and th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.2.2145610

    authors: Kaufman SL

    更新日期:1990-11-01 00:00:00

  • Acute pulmonary embolism: sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study.

    abstract:PURPOSE:To use Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) II data to retrospectively determine sensitivity and specificity of ventilation-perfusion (V/Q) scintigraphic studies categorized as pulmonary embolism (PE) present or PE absent and the proportion of patients for whom these categories app...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2463070270

    authors: Sostman HD,Stein PD,Gottschalk A,Matta F,Hull R,Goodman L

    更新日期:2008-03-01 00:00:00

  • Retrosomatic clefts: computed tomographic appearance.

    abstract::A case of bilateral clefts in the pedicles of the L1 vertebra, diagnosed by computed tomography, is presented. The differentiation from other clefts located laterally in the neural arch is briefly summarized, and the possible origin of this entity is discussed. It is improbable that the clefts represent persistent neu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6867340

    authors: Johansen JG,McCarty DJ,Haughton VM

    更新日期:1983-08-01 00:00:00

  • Bedside chest radiography: diagnostic efficacy.

    abstract::In order to evaluate the efficacy of bedside chest radiography, a prospective study was completed of 140 patients admitted to the surgical and medical intensive care units over a two-month period. A total of 1132 consecutive bedside radiographs was analyzed for malposition of tubes and lines and interval changes in th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6611930

    authors: Henschke CI,Pasternack GS,Schroeder S,Hart KK,Herman PG

    更新日期:1983-10-01 00:00:00

  • Cerebral microhemorrhage and iron deposition in mild cognitive impairment: susceptibility-weighted MR imaging assessment.

    abstract:PURPOSE:To test whether susceptibility-weighted magnetic resonance imaging at baseline may help predict cognitive decline. MATERIALS AND METHODS:This prospective study was approved by the institutional review board, and written informed consent was obtained from all participants. Thirty-five healthy control subjects a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100612

    authors: Haller S,Bartsch A,Nguyen D,Rodriguez C,Emch J,Gold G,Lovblad KO,Giannakopoulos P

    更新日期:2010-12-01 00:00:00

  • False-Positive Measurement at 2-Hydroxyglutarate MR Spectroscopy in Isocitrate Dehydrogenase Wild-Type Glioblastoma: A Multifactorial Analysis.

    abstract::Background Isocitrate dehydrogenase (IDH) mutation has become one of the most important prognostic biomarkers in glioma management. Measurement of 2-hydroxyglutarate (2HG) with MR spectroscopy has shown high pooled sensitivity, although false-positive results with MR spectroscopy have been reported. Purpose To investi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019182200

    authors: Suh CH,Kim HS,Paik W,Choi C,Ryu KH,Kim D,Woo DC,Park JE,Jung SC,Choi CG,Kim SJ

    更新日期:2019-06-01 00:00:00

  • Prospective comparison of epidural venography and iophendylate myelography in the diagnosis of herniated lumbar disks.

    abstract::Fifty consecutive patients with suspected herniated nucleus pulposus at L4-5 or L5-S1 were evaluated prospectively with both epidural venography and iophendylate myelography. The two procedures were compared with respect to diagnostic accuracy, ease of performance, and complications. Evaluation of both the L4-5 and L5...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.1.7350590

    authors: Lotz PR,Seeger JF,Gabrielsen TO

    更新日期:1980-01-01 00:00:00

  • Radiomic Features at Contrast-enhanced CT Predict Recurrence in Early Stage Hepatocellular Carcinoma: A Multi-Institutional Study.

    abstract::Background Early stage hepatocellular carcinoma (HCC) is the ideal candidate for resection in patients with preserved liver function; however, cancer will recur in half of these patients and no reliable prognostic tool has been established. Purpose To investigate the effectiveness of radiomic features in predicting tu...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2020191470

    authors: Ji GW,Zhu FP,Xu Q,Wang K,Wu MY,Tang WW,Li XC,Wang XH

    更新日期:2020-03-01 00:00:00

  • Clinical Intravoxel Incoherent Motion and Diffusion MR Imaging: Past, Present, and Future.

    abstract::The concept of diffusion magnetic resonance (MR) imaging emerged in the mid-1980s, together with the first images of water diffusion in the human brain, as a way to probe tissue structure at a microscopic scale, although the images were acquired at a millimetric scale. Since then, diffusion MR imaging has become a pil...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015150244

    authors: Iima M,Le Bihan D

    更新日期:2016-01-01 00:00:00

  • Diagnosis of osteomyelitis in children by combined blood pool and bone imaging.

    abstract::Differentiation of osteomyelitis from cellulitis or septic arthritis can be difficult. The radiological examination often does not have the characteristic features. Seventy of 71 children with osteomyelitis had focal areas of increased radioactivity at the site of the infection. The addition of "blood pool" images aid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.2.331

    authors: Gilday DL,Paul DJ,Paterson J

    更新日期:1975-11-01 00:00:00

  • Eosinophilic lung diseases: diagnostic accuracy of thin-section CT in 111 patients.

    abstract:PURPOSE:To determine whether various eosinophilic lung diseases can be differentiated by means of thin-section computed tomography (CT). MATERIALS AND METHODS:Thin-section CT scans in 111 patients with eosinophilic lung diseases-40 with chronic eosinophilic pneumonia, 16 with Churg-Strauss syndrome, 16 with allergic b...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.3.r00se01773

    authors: Johkoh T,Müller NL,Akira M,Ichikado K,Suga M,Ando M,Yoshinaga T,Kiyama T,Mihara N,Honda O,Tomiyama N,Nakamura H

    更新日期:2000-09-01 00:00:00

  • Congenital hepatic artery aneurysm simulating pancreatic carcinoma.

    abstract::The authors report a case of a hepatic artery aneurysm that simulated a mass in the head of the pancreas. The correct diagnosis was made preoperatively based on several findings: curvilinear calcification within the mass on CT, a well-defined cystic collection on ultrasound, absence of biliary duct dilatation or jaund...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.3.6463240

    authors: Gavin PM,Matalon TA,Petasnick JP,Roseman DL

    更新日期:1984-09-01 00:00:00

  • Heterotopic bone formation after hip surgery: prevention with single-dose postoperative hip irradiation.

    abstract::From 1981 to 1986, 23 patients (24 hips) were treated with single-dose irradiation after hip surgery in an attempt to prevent heterotopic bone formation. All patients were at high risk for the development of heterotopic ossification because of the presence of heterotopic bone in either hip secondary to trauma or previ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.3.3136510

    authors: Lo TC,Healy WL,Covall DJ,Dotter WE,Pfeifer BA,Torgerson WR,Wasilewski SA

    更新日期:1988-09-01 00:00:00

  • Virtual autopsy: preliminary experience in high-velocity gunshot wound victims.

    abstract:PURPOSE:To retrospectively assess virtual autopsy performed with multidetector computed tomography (CT) for the forensic evaluation of gunshot wound victims. MATERIALS AND METHODS:The institutional review board approved this HIPAA-compliant study and did not require informed consent of the next of kin. Thirteen consec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2402050972

    authors: Levy AD,Abbott RM,Mallak CT,Getz JM,Harcke HT,Champion HR,Pearse LA

    更新日期:2006-08-01 00:00:00

  • Whole-body PET/CT scanning: estimation of radiation dose and cancer risk.

    abstract:PURPOSE:To estimate the radiation dose from whole-body fluorine 18 ((18)F)-fluorodeoxyglucose (FDG) positron emission tomographic (PET)/computed tomographic (CT) studies and to evaluate the induced cancer risk to U.S. and Hong Kong populations. MATERIALS AND METHODS:Fluorine 18-FDG PET/CT studies obtained by using a 6...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2511081300

    authors: Huang B,Law MW,Khong PL

    更新日期:2009-04-01 00:00:00

  • Osteoid osteoma: CT-guided percutaneous excision confirmed with immediate follow-up scintigraphy in 16 outpatients.

    abstract:PURPOSE:To evaluate treatment of osteoid osteoma with computed tomography (CT)-guided percutaneous excision and immediate follow-up scintigraphy. MATERIALS AND METHODS:Sixteen consecutive adolescent and adult patients underwent CT-guided percutaneous excision of a nidus with 14-gauge biopsy cutting needles, with local...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.1.8816550

    authors: Roger B,Bellin MF,Wioland M,Grenier P

    更新日期:1996-10-01 00:00:00

  • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose.

    abstract:PURPOSE:To show that prospective electrocardiographically (ECG)-triggered coronary computed tomographic (CT) angiography (hereafter, prospective CT angiography) is at least as effective as retrospective ECG-gated coronary CT angiography (hereafter, retrospective CT angiography). MATERIALS AND METHODS:Institutional rev...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2482071804

    authors: Hirai N,Horiguchi J,Fujioka C,Kiguchi M,Yamamoto H,Matsuura N,Kitagawa T,Teragawa H,Kohno N,Ito K

    更新日期:2008-08-01 00:00:00

  • Biplane stereoscopic magnification cerebral angiography.

    abstract::An angiographic system capable of simultaneous biplane stereoscopic magnification cerebral angiography was evaluated. Stereoscopic imaging improved the morphologic depiction of aneurysms and of arteriovenous malformations. In a series of 357 patients, procedure time was reduced because the initial biplane stereoscopic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.2.3659390

    authors: Kleefield J,O'Reilly GV,Barsotti JB,Brooks ML

    更新日期:1987-11-01 00:00:00

  • Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

    abstract:PURPOSE:To investigate the effect of duration and rate of contrast material injection on aortic peak time and peak enhancement in an injection protocol in which the contrast material dose is adjusted according to patient weight. MATERIALS AND METHODS:One hundred ninety-nine patients were randomly divided into three gr...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiol.2301021008

    authors: Awai K,Hiraishi K,Hori S

    更新日期:2004-01-01 00:00:00

  • Benign clear-cell tumor ("sugar" tumor) of the lung: a case report and review of the literature.

    abstract::Benign clear-cell tumor of the lung is a rare, distinctive, primary neoplasm with unique histologic and electron microscopic features which may resemble metastatic renal-cell carcinoma. This tumor typically presents as an asymptomatic, peripheral, sharply rounded mass in the lung. Clinical recognition can prevent an u...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.3.595

    authors: Harbin WP,Mark GJ,Greene RE

    更新日期:1978-12-01 00:00:00