Osteoid osteoma: CT-guided percutaneous excision confirmed with immediate follow-up scintigraphy in 16 outpatients.

Abstract:

PURPOSE:To evaluate treatment of osteoid osteoma with computed tomography (CT)-guided percutaneous excision and immediate follow-up scintigraphy. MATERIALS AND METHODS:Sixteen consecutive adolescent and adult patients underwent CT-guided percutaneous excision of a nidus with 14-gauge biopsy cutting needles, with local anesthesia. After the presence of nidus was confirmed at immediate follow-up scintigraphy, curettage of the bored cavity was performed to remove any residual fragments of the nidus. Scintigraphic and histologic findings were correlated. RESULTS:The nidus was removed successfully in 14 of the 16 patients, with no complications (mean follow-up, 15 months; range, 3-25 months). In five of the 14 patients, immediate follow-up scintigraphy showed incomplete resection of the nidus and immediate second resection was successful. Surgical resection was necessary in two of the 16 patients. CONCLUSION:CT-guided percutaneous excision with immediate follow-up scintigraphy was safe and effective for localization and removal of osteoid osteoma in outpatients.

journal_name

Radiology

journal_title

Radiology

authors

Roger B,Bellin MF,Wioland M,Grenier P

doi

10.1148/radiology.201.1.8816550

subject

Has Abstract

pub_date

1996-10-01 00:00:00

pages

239-42

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

201

pub_type

杂志文章
  • Switched surface coil system for bilateral MR imaging.

    abstract::A method is presented for acquiring magnetic resonance (MR) images in parallel from both members of a pair of organs, such as the temporomandibular joint (TMJ), with use of two surface coil receivers. Interleaved sagittal sections are broken into two groups, one on each side of the head, and the MR receiver is toggled...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.3.3363150

    authors: Hardy CJ,Katzberg RW,Frey RL,Szumowski J,Totterman S,Mueller OM

    更新日期:1988-06-01 00:00:00

  • Hepatic helical CT: effect of reduction of iodine dose of intravenous contrast material on hepatic contrast enhancement.

    abstract:PURPOSE:To evaluate the effect of a reduction in iodine dose by altering volume and/or concentration of contrast material on hepatic contrast enhancement (HCE) values during hepatic helical computed tomography (CT). MATERIALS AND METHODS:One hundred eleven patients were randomized into four contrast material protocols...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.197.1.7568860

    authors: Freeny PC,Gardner JC,vonIngersleben G,Heyano S,Nghiem HV,Winter TC

    更新日期:1995-10-01 00:00:00

  • Relationship of Trochlear Morphology and Patellofemoral Joint Alignment to Superolateral Hoffa Fat Pad Edema on MR Images in Individuals with or at Risk for Osteoarthritis of the Knee: The MOST Study.

    abstract::Purpose To determine the relationship of patellofemoral joint alignment and trochlear morphology to superolateral Hoffa fat pad (SHFP) edema on magnetic resonance (MR) images in older adults with or at risk for osteoarthritis of the knee. Materials and Methods Institutional review board approval and written informed c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162342

    authors: Widjajahakim R,Roux M,Jarraya M,Roemer FW,Neogi T,Lynch JA,Lewis CE,Torner JC,Felson DT,Guermazi A,Stefanik JJ

    更新日期:2017-09-01 00:00:00

  • Intravoxel incoherent motion diffusion-weighted MR imaging for characterization of focal pancreatic lesions.

    abstract:PURPOSE:To evaluate the diagnostic potential of apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM)-derived parameters for differentiation of common pancreatic tumors, chronic pancreatitis, and normal pancreas and for characterization of the malignancy potential of intraductal papillary mucinou...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13122712

    authors: Kang KM,Lee JM,Yoon JH,Kiefer B,Han JK,Choi BI

    更新日期:2014-02-01 00:00:00

  • Combined FDG and [F-18]fluoride whole-body PET: a feasible two-in-one approach to cancer imaging?

    abstract:PURPOSE:To evaluate the diagnostic usefulness of the combined application of 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG; for the evaluation of soft tissue) and [F-18]fluoride (for the evaluation of the skeleton) in positron emission tomography (PET) of cancer. MATERIALS AND METHODS:Sixty consecutive patients (23 wom...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.209.1.9769840

    authors: Hoegerle S,Juengling F,Otte A,Altehoefer C,Moser EA,Nitzsche EU

    更新日期:1998-10-01 00:00:00

  • A new catheter design for percutaneous cholecystostomy.

    abstract::A catheter specifically designed for percutaneous cholecystostomy was inserted into the gallbladders of 17 hospitalized patients who were thought to have acute cholecystitis. Cholecystostomies were performed in all patients without complications, and catheters were inserted in the intensive care unit with use of porta...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.1.3275970

    authors: McGahan JP

    更新日期:1988-01-01 00:00:00

  • Releif of severe fecal impactions with water-soluble contrast enemas.

    abstract::High fecal impaction resulted in complete bowel obstruction in 2 children following renal transplantation and in one adult on chemotherapy and narcotics. The usual methods of relief failed, and water-soluble contrast enemas with a high osmolality were employed. Fluoroscopic control assured placement of the enema fluid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.9

    authors: Culp WC

    更新日期:1975-04-01 00:00:00

  • Deep Learning-based Automatic Detection Algorithm for Reducing Overlooked Lung Cancers on Chest Radiographs.

    abstract::Background It is uncertain whether a deep learning-based automatic detection algorithm (DLAD) for identifying malignant nodules on chest radiographs will help diagnose lung cancers. Purpose To evaluate the efficacy of using a DLAD in observer performance for the detection of lung cancers on chest radiographs. Material...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020200165

    authors: Jang S,Song H,Shin YJ,Kim J,Kim J,Lee KW,Lee SS,Lee W,Lee S,Lee KH

    更新日期:2020-09-01 00:00:00

  • Improved patency of transjugular intrahepatic portosystemic shunts in humans: creation and revision with PTFE stent-grafts.

    abstract:PURPOSE:To determine whether polytetrafluoroethylene (PTFE) stent-grafts yield longer patency for creation or revision of transjugular intrahepatic portosystemic shunts (TIPS). MATERIALS AND METHODS:Fourteen PTFE-covered Wallstents were placed in 13 patients with TIPS: seven at shunt creation and seven during revision...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.3.r99dc28759

    authors: Haskal ZJ

    更新日期:1999-12-01 00:00:00

  • Asymptomatic and neurologically symptomatic HIV-seropositive subjects: results of long-term MR imaging and clinical follow-up.

    abstract::Cranial magnetic resonance (MR) images were prospectively obtained in 74 human immunodeficiency virus (HIV)-seropositive subjects, all of whom had undergone MR imaging 24-42 months earlier. The images were interpreted by neuroradiologists blinded to the subject's clinical status and were compared with the initial MR i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351340

    authors: Post MJ,Berger JR,Duncan R,Quencer RM,Pall L,Winfield D

    更新日期:1993-09-01 00:00:00

  • Portal-systemic encephalopathy: presence of basal ganglia lesions with high signal intensity on MR images.

    abstract::Sixteen patients with cirrhosis of the liver underwent cranial magnetic resonance (MR) imaging and transarterial portography to evaluate the relationship between basal ganglia lesions and portal-systemic collateral vessels. No neuropsychiatric disturbance was observed in any of the patients at the time of the MR exami...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014310

    authors: Inoue E,Hori S,Narumi Y,Fujita M,Kuriyama K,Kadota T,Kuroda C

    更新日期:1991-05-01 00:00:00

  • Base-of-tongue cancer treated with external beam irradiation plus brachytherapy: oncologic and functional outcome.

    abstract::Between January 1981 and June 1990, 36 previously untreated patients with squamous cancer of the base of the tongue were treated with radiation therapy. This therapy consisted of a 5,000-5,400-cGy external beam plus a 2,000-3,000-cGy boost to the base of the tongue with an iridium-192 implant. Necks with negative node...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.184.1.1609090

    authors: Harrison LB,Zelefsky MJ,Sessions RB,Fass DE,Armstrong JG,Pfister DG,Strong EW

    更新日期:1992-07-01 00:00:00

  • Pneumatosis coli secondary to acute appendicitis. Case report.

    abstract::An unusual case of pneumatosis coli is presented. The patient had acute inflammatory disease with gangrene of the appendix associated with air within the wall of the contiguous right colon. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.1.90

    authors: DiDonato LR

    更新日期:1976-07-01 00:00:00

  • Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.

    abstract:PURPOSE:To analyze the effect of a decrease in computed tomographic (CT) colonographic voltage, from 100 and 120 kVp to 80 kVp and reconstructed with filtered back projection ( FBP filtered back projection ), on radiation dose, image noise, and diagnostic performance in anthropomorphic phantoms and to assess the effect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140192

    authors: Shin CI,Kim SH,Lee ES,Lee DH,Hwang EJ,Chung SY,Lee JM,Han JK,Choi BI

    更新日期:2014-12-01 00:00:00

  • Characteristics and trends of radiology research: a survey of original articles published in AJR and Radiology between 2001 and 2010.

    abstract:PURPOSE:To determine the characteristics and trends of the original articles published in two major American radiology journals, AJR American Journal of Roentgenology (AJR) and Radiology, between 2001 and 2010. MATERIALS AND METHODS:This was a retrospective bibliometric analysis that did not involve human subjects and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12111976

    authors: Lim KJ,Yoon DY,Yun EJ,Seo YL,Baek S,Gu DH,Yoon SJ,Han A,Ku YJ,Kim SS

    更新日期:2012-09-01 00:00:00

  • Gallium scanning as a screening test for inflammatory lesions.

    abstract::Of the 67-Ga scans obtained in 42 patients with fever and suspected inflammatory lesions, 17 were positive. In 9 patients the scans yielded information about localized inflammation not provided by previous studies. Four patients did not have an inflammatory lesion at the positive site. Ten of 13 abscesses or inflamed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.2.383

    authors: Teates CD,Hunter JG Jr

    更新日期:1975-08-01 00:00:00

  • Gallbladder ablation through radiologic intervention: an experimental alternative to cholecystectomy.

    abstract::Twenty pigs underwent (a) cystic duct occlusion by means of fluoroscopically guided transcatheter endoluminal bipolar radio-frequency (RF) electrocoagulation and (b) gallbladder sclerotherapy with one of two different regimens of ethanol and sodium tetradecyl-sulfate (STS). Serum ethanol levels and hepatic enzyme test...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.1.2928530

    authors: Becker CD,Quenville NF,Burhenne HJ

    更新日期:1989-04-01 00:00:00

  • Delayed ischemic stroke after stent-assisted coil placement in cerebral aneurysm: characteristics and optimal duration of preventative dual antiplatelet therapy.

    abstract:PURPOSE:To evaluate characteristics of delayed ischemic stroke after stent-assisted coil placement in cerebral aneurysms and to determine the optimal duration of dual antiplatelet therapy for its prevention. MATERIALS AND METHODS:This retrospective study was approved by the institutional review board, and the requirem...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140070

    authors: Hwang G,Kim JG,Song KS,Lee YJ,Villavicencio JB,Suroto NS,Park NM,Park SJ,Jeong EA,Kwon OK

    更新日期:2014-10-01 00:00:00

  • Pilonidal sinus disease: MR imaging distinction from fistula in ano.

    abstract:PURPOSE:To describe magnetic resonance (MR) imaging features in patients with proved pilonidal sinus disease and to compare these features with those in a matched group of patients with proved fistula in ano to determine the accuracy with which MR imaging can be used to distinguish between the two diseases. MATERIALS ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2263011758

    authors: Taylor SA,Halligan S,Bartram CI

    更新日期:2003-03-01 00:00:00

  • Appendicitis caused by carcinoid tumor.

    abstract::A previously healthy man had a carcinoid tumor that caused obstruction and dilatation of the appendiceal lumen, with subsequent inflammation of the appendix. He had acute pain in the lower right abdomen, loss of appetite, constipation, pyrexia, and an increased erythrocyte sedimentation rate without leukocytosis. Alth...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.1.8511320

    authors: Hermans JJ,Hermans AL,Risseeuw GA,Verhaar JC,Meradji M

    更新日期:1993-07-01 00:00:00

  • Acalculous gallbladder disease: US evaluation after slow-infusion cholecystokinin stimulation in symptomatic and asymptomatic adults.

    abstract:PURPOSE:To evaluate the measurement with ultrasonography (US) of the gallbladder ejection fraction after slow-infusion cholecystokinin stimulation in patients with biliary symptoms and in individuals without symptoms. MATERIALS AND METHODS:Gallbladder volumes were calculated in 60 healthy volunteers after a 30-minute ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.1.9205230

    authors: Barr RG,Agnesi JN,Schaub CR

    更新日期:1997-07-01 00:00:00

  • Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession.

    abstract::In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2223011156

    authors: Lee VS,Resnick D,Bundy JM,Simonetti OP,Lee P,Weinreb JC

    更新日期:2002-03-01 00:00:00

  • Renal hyperconcentration of 99mTc-HEDP in experimental acute tubular necrosis.

    abstract::The effect of transient renal ischemia on renal concentration and distribution of 99mTc-HEDP, 99mTc-DMSA, and 99mTc-DTPA was compared in rabbits with acute tubular necrosis. Scintigrams were obtained after injection in normal rabbits or ones with unilateral or bilateral ischemia. 99mTc-HEDP concentration in ischemic t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.2.491

    authors: Lavelle KJ,Park HM,Moseman AM,Lewis S

    更新日期:1979-05-01 00:00:00

  • A simple traction device for use in the radiology department.

    abstract::Portable sustained graded traction for control of the displaced cervical spine particularly for patients undergoing tomography or gas myelography, is described. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.826

    authors: Deeb ZL,Drayer BP,Rosenbaum AE

    更新日期:1977-12-01 00:00:00

  • Liposarcoma of the extremities: MR and CT findings in the histologic subtypes.

    abstract::The findings on images of liposarcomas of the extremities in 48 patients (26 men and 22 women aged 20-85 years) were reviewed to correlate the histologic subtypes with radiologic appearance. Computed tomographic scans were obtained in 36 patients; magnetic resonance (MR) images, in 27 patients. The study group had 19 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.2.8421750

    authors: Jelinek JS,Kransdorf MJ,Shmookler BM,Aboulafia AJ,Malawer MM

    更新日期:1993-02-01 00:00:00

  • Videodensitometric quantitation of stenosis: in vitro and in vivo validation.

    abstract::Percentage of stenosis of a vascular lumen was quantitated using a digital subtraction angiography system with videodensitometric analysis. To validate the algorithm and methods, we used precisely drilled Lucite rods of three inner diameters and various reduced diameters to give known luminal reduction. Both in vitro ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.3.3903860

    authors: Seibert JA,Link DP,Hines HH,Baltaxe HA

    更新日期:1985-12-01 00:00:00

  • Radionuclide bone imaging in the early detection of fractures of the proximal femur (hip): multifactorial analysis.

    abstract::The results of 179 radionuclide bone imaging examinations, 105 gathered retrospectively from the cases of 97 patients referred for assessment of possible occult fracture of the proximal femur (hip) and 74 performed prospectively on 63 patients referred with a diagnosis of obvious or suspected hip fracture, were analyz...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.2.2404320

    authors: Holder LE,Schwarz C,Wernicke PG,Michael RH

    更新日期:1990-02-01 00:00:00

  • Quantitative Shear-Wave US Elastography of the Supraspinatus Muscle: Reliability of the Method and Relation to Tendon Integrity and Muscle Quality.

    abstract:PURPOSE:To evaluate the reliability of ultrasonographic (US) elastography of the supraspinatus (SSP) muscle, define normal shear-wave velocity (SWV) values, and correlate findings with tendon integrity and muscle quality. MATERIALS AND METHODS:The study was approved by the local ethics committee, and written informed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150908

    authors: Rosskopf AB,Ehrmann C,Buck FM,Gerber C,Flück M,Pfirrmann CW

    更新日期:2016-02-01 00:00:00

  • Can sonographers reliably identify anatomic features associated with Down syndrome in fetuses?

    abstract::To standardize femur measurement for the identification of fetuses at risk for Down syndrome, sonographers of varying professional experience and background measured the femurs of 20 Down syndrome fetuses and 709 normal control fetuses. A regression analysis performed to compare biparietal diameter to femur length on ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.2.2529580

    authors: Benacerraf BR,Cnann A,Gelman R,Laboda LA,Frigoletto FD Jr

    更新日期:1989-11-01 00:00:00

  • Metabolic disorders of the brain in chronic hepatic encephalopathy detected with H-1 MR spectroscopy.

    abstract::Proton magnetic resonance (MR) spectroscopy of the brain was performed in 11 patients with chronic hepatic encephalopathy (CHE), and the results were compared with those of patients with liver disease but without CHE; clinical control subjects with diabetes, uremia, or cortical atrophy; and healthy subjects. The techn...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.182.1.1345760

    authors: Kreis R,Ross BD,Farrow NA,Ackerman Z

    更新日期:1992-01-01 00:00:00