Microinjection manipulation decreases the expression of GABA-A receptor signaling pathway genes in mouse embryos derived using intracytoplasmic sperm injection.

Abstract:

BACKGROUND:The GABA-A receptor signaling pathway regulates proliferation, differentiation, apoptosis, and responses to overt DNA damage during embryonic development. METHODS:To analyze the gene expression after intracytoplasmic sperm injection (ICSI) and in in vivo mouse embryos, the global pattern of gene expression dataset, GSE23009, was obtained from the Gene Expression Omnibus database. Genes with differential expression were identified using the R software package, and RT-qPCR was performed to confirm the microarray results. RESULTS:Mouse blastocysts derived from ICSI fertilization had decreased expression of GABA-A receptor signaling pathway genes. However, the mechanisms underlying these changes were not elucidated. The gene expression of the GABA-A pathway was not significantly different between blastocysts obtained from IVF and in vivo fertilization. However, microinjection after IVF significantly reduced the expression of the GABA-A pathway gene to levels similar to those in the ICSI group. CONCLUSION:Based on our results, decreased gene expression is a result of the microinjection manipulation performed during ICSI.

journal_name

J Clin Lab Anal

authors

Zhang Z,Wang T,Huang J,Huang Y,Zhang Q

doi

10.1002/jcla.23584

subject

Has Abstract

pub_date

2020-09-20 00:00:00

pages

e23584

eissn

0887-8013

issn

1098-2825

pub_type

杂志文章
  • Platelet antibody analysis by three different tests.

    abstract:BACKGROUND:Platelet-reactive antibodies lead to thrombocytopenia and bleeding disorders, and diverse assays are used for their detection. In this retrospective analysis, the applicability of three different test systems was compared and antibody specificities were assessed. METHODS:Sera of 1,234 patients were tested w...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21750

    authors: Sareban N,Macher S,Drexler C,Posch U,Lanzer G,Schallmoser K

    更新日期:2015-05-01 00:00:00

  • Evaluation of the poly(ADP-ribose) polymerase-1 gene variants in Alzheimer's disease.

    abstract::Amyloid peptide is thought to play a critical role in neuronal death in Alzheimer's disease (AD), most likely through oxidative stress. Free radical-related injury leads to DNA breaks, which subsequently activates the repair enzyme poly(ADP-ribose) polymerase-1 (PARP-1). In this study, the relationship between genetic...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20379

    authors: Liu HP,Lin WY,Wu BT,Liu SH,Wang WF,Tsai CH,Lee CC,Tsai FJ

    更新日期:2010-01-01 00:00:00

  • Impaired interleukin-2 production by T-lymphocytes in polycythemia vera.

    abstract::T-lymphocyte function was investigated in a group of eight patients with polycythemia vera (PV) and 13 normals. Responsiveness of T-cells to stimulation by mitogen was significantly impaired in the PV patients (p = .02). Analysis of immune cell subpopulation composition by assessment of cell surface phenotype did not ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860030204

    authors: Paul CC,Baumann MA

    更新日期:1989-01-01 00:00:00

  • Reference distributions for complement proteins C3 and C4: a practical, simple and clinically relevant approach in a large cohort.

    abstract::The two serum proteins of the complement cascade in the highest concentrations, C3 and C4, respond to various conditions in much the same manner as do other positive acute-phase proteins. A major difference is that they are relatively sluggish in response to cytokine drive, requiring several days rather than hours to ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10100

    authors: Ritchie RF,Palomaki GE,Neveux LM,Navolotskaia O,Ledue TB,Craig WY

    更新日期:2004-01-01 00:00:00

  • Assessment of urinary total testosterone production by a highly sensitive time-resolved fluorescence immunoassay.

    abstract::Radioimmunoassay (RIA) that involves purification of the analyte by organic solvent extraction is widely used. Although the extraction RIA is reliable when properly validated, it is time consuming and radioactive, we measure urinary total testosterone with a highly sensitive rapid and accurate time-resolved fluorescen...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20283

    authors: Bao S,Peng Y,Sheng S,Lin Q

    更新日期:2008-01-01 00:00:00

  • Alterations of the hematologic cells in synthetic cannabinoid users.

    abstract:BACKGROUND:Functions, morphology, distributions, and index of the circulating cells are the most useful parameters that indicate various inflammatory and toxic conditions. The aim of this study was to investigate the clinical significance of these parameters in patients diagnosed with (synthetic) cannabis use disorder....

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22131

    authors: Guzel D,Yazici AB,Yazici E,Erol A

    更新日期:2017-11-01 00:00:00

  • Specificity of autoantibodies to SS-A/Ro on a transfected and overexpressed human 60 kDa Ro autoantigen substrate.

    abstract::The objective of this study was to analyze apparently discrepant results that arose during the use of an indirect immunofluorescence (IIF) assay using transfected HEp-2 cells to detect anti-SS-A/Ro autoantibodies in human sera. Fourteen sera that had SS-A/Ro antibodies as detected on this commercial substrate, but did...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10026

    authors: Fritzler MJ,Hanson C,Miller J,Eystathioy T

    更新日期:2002-01-01 00:00:00

  • Clinical evaluation of a multiparametric ELISA as a rapid tool for routinely diagnosing IgG-mediated autoimmune blistering dermatoses in ethnic Slavs.

    abstract:BACKGROUND:Technical innovation of autoimmune blistering dermatoses (ABDs) diagnosis aimed at multiplex approach. Two multiparametric ELISA tests are commercially available for ABDs serology. The aim was to compare diagnostic accuracy of multiparametric and monospecific ELISAs and to examine the diagnostic value/agreem...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22336

    authors: Gornowicz-Porowska J,Seraszek-Jaros A,Bowszyc-Dmochowska M,Bartkiewicz P,Kaczmarek E,Dmochowski M

    更新日期:2018-05-01 00:00:00

  • Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods.

    abstract:BACKGROUND:The study evaluated the impact of interferences on the analytical specificity of three commercial and commonly used creatinine methods (two Jaffe and one enzymatic). METHODS:Manufacturer creatinine methods plus modified methods were tested with the following interferences: spiking serum with bilirubin, albu...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20350

    authors: Srisawasdi P,Chaichanajarernkul U,Teerakanjana N,Vanavanan S,Kroll MH

    更新日期:2010-01-01 00:00:00

  • Comparison of three commonly used PCR-based techniques to analyze MSI status in sporadic colorectal cancer.

    abstract::Several retrospective studies have shown that a high level of microsatellite instability (MSI-H) is an important prognostic factor of a more favorable outcome in stage II and III colorectal cancer (CRC) patients. In this study, three commonly used polymerase chain reaction (PCR)-based MSI analysis techniques were comp...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20097

    authors: Deschoolmeester V,Baay M,Wuyts W,Van Marck E,Pelckmans P,Lardon F,Vermorken JB

    更新日期:2006-01-01 00:00:00

  • Quality specification and status of internal quality control of cardiac biomarkers in China from 2011 to 2016.

    abstract:BACKGROUND:This study aimed to investigate the status of internal quality control (IQC) for cardiac biomarkers from 2011 to 2016 so that we can have overall knowledge of the precision level of measurements in China and set appropriate precision specifications. METHODS:Internal quality control data of cardiac biomarker...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22324

    authors: Li T,Wang W,Zhao H,He F,Zhong K,Yuan S,Wang Z

    更新日期:2018-05-01 00:00:00

  • A new blood collection device minimizes cellular DNA release during sample storage and shipping when compared to a standard device.

    abstract:BACKGROUND:Cell-free DNA (cfDNA) circulating in blood is currently used for noninvasive diagnostic and prognostic tests. Minimizing background DNA is vital for detection of low abundance cfDNA. We investigated whether a new blood collection device could reduce background levels of genomic DNA (gDNA) in plasma compared ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21603

    authors: Norton SE,Luna KK,Lechner JM,Qin J,Fernando MR

    更新日期:2013-07-01 00:00:00

  • Immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 gp41 antigen using synthetic peptides as antigens.

    abstract::The immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 gp41 antigen was developed using two synthetic peptides. An aliquot (10 microl) of serum samples from HIV-1 seropositive subjects was incubated simultaneously with 2,4-dinitrophenyl-bovine serum albumin-synthetic HIV-1 gp41 peptide conjugates and...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Hashida S,Ishikawa S,Hashinaka K,Nishikata I,Oka S,Ishikawa E

    更新日期:1998-01-01 00:00:00

  • Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals.

    abstract:BACKGROUND:The prevalence of diabetes is increasing in China. Glucose control is very important in diabetic patients. The aim of this study was to compare the accuracy of five glucose meters used in Chinese hospitals with a reference method, in the absence and presence of various factors that may interfere with the met...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21611

    authors: Lv H,Zhang GJ,Kang XX,Yuan H,Lv YW,Wang WW,Randall R

    更新日期:2013-09-01 00:00:00

  • Identical IgM antibodies recognizing a glycine-alanine epitope are induced during acute infection with Epstein-Barr virus and cytomegalovirus.

    abstract::We studied antibody production in serial serum samples from patients with acute Epstein-Barr virus (EBV) and cytomegalovirus (CMV) infections. Sera were analyzed both by enzyme-linked immunosorbent assay (ELISA) using a synthetic peptide (P62) derived from the glycine-alanine repeating region of the Epstein-Barr nucle...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040613

    authors: Rhodes G,Smith RS,Rubin RE,Vaughan J,Horwitz CA

    更新日期:1990-01-01 00:00:00

  • Clinical significance of the serum IgM and IgG to SARS-CoV-2 in coronavirus disease-2019.

    abstract:OBJECTIVE:To explore the clinical value of serum IgM and IgG to SARS-CoV-2 in COVID-19. METHODS:105 COVID-19 patients were enrolled as the disease group. 197 non-COVID-19 patients served as the control group. Magnetic chemiluminescent immunoassay (MCLIA) was used to detect the IgM and IgG. RESULTS:The peak of positiv...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23649

    authors: Wu LX,Wang H,Gou D,Fu G,Wang J,Guo BQ

    更新日期:2020-11-13 00:00:00

  • An immunoenzymometric assay for a CA125-like antigen, CA602.

    abstract::An immunoenzymometric assay (IEMA) for a new CA125-like antigen, CA602, was developed. Five monoclonal antibodies raised against a human ovarian carcinoma cell line could detect their respective antigens in the sera of ovarian carcinoma patients. The antigen levels detected in serum by the various antibodies correlate...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860060204

    authors: Mochizuki H,Sato I,Nagoya K,Furusako S,Yamauchi T,Masuko H,Sato H,Morishita H,Yajima M,Sasaki H

    更新日期:1992-01-01 00:00:00

  • Role of TLR4 and miR-155 in peripheral blood mononuclear cell-mediated inflammatory reaction in coronary slow flow and coronary arteriosclerosis patients.

    abstract:BACKGROUND:To study the role of toll-like receptor 4 (TLR4) and MicroRNA-155 (miR-155) in the peripheral blood mononuclear cell (PBMC)-mediated inflammation in coronary slow flow (CSF) and coronary arteriosclerosis. METHODS:Patients were divided into acute coronary syndrome (ACS), stable angina pectoris (SAP), CSF, an...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22232

    authors: Huang J,Yang Q,He L,Huang J

    更新日期:2018-02-01 00:00:00

  • Circulating level of lipocalin 2 as a predictor of severity in patients with community-acquired pneumonia.

    abstract:BACKGROUND:The aim of this study was to investigate the differential plasma levels of lipocalin 2 (LCN2) and its complex with MMP-9 (where MMP is matrix metalloproteinase) before and after antibiotic treatment in hospitalized adult patients with community-acquired pneumonia (CAP). METHOD:Plasma LCN2 and LCN2/MMP-9 com...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21588

    authors: Yeh YH,Chang JL,Hsiao PC,Tsao SM,Lin CH,Kao SJ,Chou MC,Yang SF,Chien MH

    更新日期:2013-07-01 00:00:00

  • Multiplex assay for genetic testing of thrombophilia: a method for routine clinical care.

    abstract::There is an increasing demand for genetic testing of patients with hypercoagulability. We have developed a multiplex-polymerase chain reaction (PCR) technique that incorporates the state-of-the art of genetic testing for thrombosis mutations (Factor V Leiden [FVL] and G20210A F2 and C46T F12). The sequences are detect...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20183

    authors: López M,Giraldo P,Alvarez P,Cornudella R,Pocoví M,Martínez A,Fontcuberta J,Soria JM

    更新日期:2007-01-01 00:00:00

  • Colorimetric Detection by Gold Nanoparticle DNA Probes for Miltenberger Series (GP.Mur, GP.Hop, and GP.Bun) Identification.

    abstract:BACKGROUND:Miltenberger (Mi) series are the collective glycophorin hybrids in the MNS blood group system. Mi series are composed of several subtypes, for examples, GP.Mur, GP.Hop, and GP.Bun. The incompatibility of Mi series blood transfusion poses the risk of hemolysis. Due to the lack of standard antibodies for Mi se...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21951

    authors: Vongsakulyanon A,Pipatpanukul C,Kitpoka P,Kunakorn M,Srikhirin T

    更新日期:2016-11-01 00:00:00

  • Distribution characteristics of different human papillomavirus genotypes in women in Wuhan, China.

    abstract:BACKGROUND:Human papillomaviruses (HPVs) are strongly associated with the development of cervical carcinoma, and the distribution of HPV genotypes varies regionally. METHODS:To investigate the distribution characteristics of different genotypes of HPV infection in women in Wuhan, China, a total of 13 775 patients were...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22581

    authors: Xiang F,Guan Q,Liu X,Xiao H,Xia Q,Liu X,Sun H,Song X,Zhong Y,Yuan CH,Xiang Y

    更新日期:2018-10-01 00:00:00

  • Molecular detection of trisomy 21 by bicolor competitive fluorescent PCR.

    abstract:OBJECTIVE:To develop a reliable and specific method for rapid prenatal diagnosis of Trisomy 21 (Down syndrome). METHODS:We established a dual color competitive fluorescent Polymerase Chain Reaction (PCR) to measure the gene dosage of Down syndrome critical region (DSCR), a single copy sequence in chromosome 21. Anothe...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21593

    authors: Wang Y,Zhang X,Ling B,He C,Xia Q,Chen F,Miyamori I,Yang Z,Fan C

    更新日期:2013-05-01 00:00:00

  • Adrenal diffuse large B-cell lymphoma with high PD-L1 expression: Two case reports and literature review.

    abstract:BACKGROUND:Primary adrenal lymphoma (PAL) is an infrequent malignant disease and there is no consensus classification or specialized treatment for it. However, PAL has been observed to have worse prognosis compared with other extrarenal malignant lymphomas and diffuse large B-cell lymphoma presents as the most common s...

    journal_title:Journal of clinical laboratory analysis

    pub_type:

    doi:10.1002/jcla.23173

    authors: Chen Y,He HS,Hu QF,Wang G

    更新日期:2020-05-01 00:00:00

  • Reliability of low-avidity IgG and of IgA in the diagnosis of primary infection by rubella virus with adaptation of a commercial test.

    abstract::The detection of IgA and low-avidity IgG and antibodies in serum is a potentially useful marker of recent infection by a microorganism. We studied the reliability of IgG avidity and presence of IgA for the diagnosis of recent acute infection by rubella virus. Low-avidity IgG (Avy-EIA test) was determined with a modifi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Gutiérrez J,Rodríguez MJ,De Ory F,Piédrola G,Maroto MC

    更新日期:1999-01-01 00:00:00

  • Effect of pneumatic tube delivery system rate and distance on hemolysis of blood specimens.

    abstract:BACKGROUND:We evaluated the effects of pneumatic tube system (PTS) transport rates and distances on routine hematology and coagulation analysis. PTS effects on centrifuged blood samples were also examined. METHOD:The study was completed at Dicle University Hospital, which has the longest pneumatic tube system in Turke...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21484

    authors: Evliyaoğlu O,Toprak G,Tekin A,Başarali MK,Kilinç C,Colpan L

    更新日期:2012-02-01 00:00:00

  • Comparative study of total protein, and total and lipid-associated serum sialic acid levels in patients with type 2 diabetes mellitus.

    abstract::The aim of the present study was to investigate the serum total protein (TP), total sialic acid (TSA), lipid-associated sialic acid (LSA), LSA/TP, and LSA/TP values in type 2 diabetes mellitus (DM) patients. Two study groups (healthy controls and type 2 DM subjects) were examined. For the type 2 DM group, 120 patients...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10078

    authors: Ekin S,Meral I,Gunduz H,Mert N

    更新日期:2003-01-01 00:00:00

  • In situ hybridization for Helicobacter pylori in gastric mucosal biopsy specimens: quantitative evaluation of test performance in comparison with the CLOtest and thiazine stain.

    abstract::Numerous detection methods for Helicobacter Pylori (H. pylori) have been developed with varying degrees of purported diagnostic utility. We have developed a rapid nonradioactive in situ hybridization (ISH) method for H. pylori detection in paraffin-embedded tissue and assessed its relative diagnostic performance by re...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Barrett DM,Faigel DO,Metz DC,Montone K,Furth EE

    更新日期:1997-01-01 00:00:00

  • Serum 25-Hydroxyvitamin D Level and Aortic Intima-Media Thickness in Patients Without Clinical Manifestation of Atherosclerotic Cardiovascular Disease.

    abstract:OBJECTIVES:Existing evidence suggests that impaired vitamin D metabolism contribute to the development of atherosclerosis. Aortic intima-media thickness (IMT) is an earlier marker than carotid IMT of preclinical atherosclerosis. However, there is a lack of researches on direct investigation of relevance between serum 2...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21770

    authors: Kalkan GY,Gür M,Koyunsever NY,Şeker T,Gözükara MY,Uçar H,Kaypaklı O,Baykan AO,Akyol S,Türkoğlu C,Elbasan Z,Şahin DY,Çaylı M

    更新日期:2015-07-01 00:00:00

  • Modified salting-out method for DNA isolation from newborn cord blood nucleated cells.

    abstract::The present work describes modification of a widely used salting-out procedure to rapidly extract DNA suitable for PCR, using the ARMS method to amplify a target sequence in the beta-globin gene. The salting-out DNA extraction procedure did not completely remove or decrease the presence of inhibitors to PCR in a consi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Noguera NI,Tallano CE,Bragós IM,Milani AC

    更新日期:2000-01-01 00:00:00