MR-guided transcranial brain HIFU in small animal models.

Abstract:

:Recent studies have demonstrated the feasibility of transcranial high-intensity focused ultrasound (HIFU) therapy in the brain using adaptive focusing techniques. However, the complexity of the procedures imposes provision of accurate targeting, monitoring and control of this emerging therapeutic modality in order to ensure the safety of the treatment and avoid potential damaging effects of ultrasound on healthy tissues. For these purposes, a complete workflow and setup for HIFU treatment under magnetic resonance (MR) guidance is proposed and implemented in rats. For the first time, tissue displacements induced by the acoustic radiation force are detected in vivo in brain tissues and measured quantitatively using motion-sensitive MR sequences. Such a valuable target control prior to treatment assesses the quality of the focusing pattern in situ and enables us to estimate the acoustic intensity at focus. This MR-acoustic radiation force imaging is then correlated with conventional MR-thermometry sequences which are used to follow the temperature changes during the HIFU therapeutic session. Last, pre- and post-treatment magnetic resonance elastography (MRE) datasets are acquired and evaluated as a new potential way to non-invasively control the stiffness changes due to the presence of thermal necrosis. As a proof of concept, MR-guided HIFU is performed in vitro in turkey breast samples and in vivo in transcranial rat brain experiments. The experiments are conducted using a dedicated MR-compatible HIFU setup in a high-field MRI scanner (7 T). Results obtained on rats confirmed that both the MR localization of the US focal point and the pre- and post-HIFU measurement of the tissue stiffness, together with temperature control during HIFU are feasible and valuable techniques for efficient monitoring of HIFU in the brain. Brain elasticity appears to be more sensitive to the presence of oedema than to tissue necrosis.

journal_name

Phys Med Biol

authors

Larrat B,Pernot M,Aubry JF,Dervishi E,Sinkus R,Seilhean D,Marie Y,Boch AL,Fink M,Tanter M

doi

10.1088/0031-9155/55/2/003

subject

Has Abstract

pub_date

2010-01-21 00:00:00

pages

365-88

issue

2

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(10)23122-6

journal_volume

55

pub_type

杂志文章
  • The observation and analysis of cancer deaths among classified radiation workers.

    abstract::The extent to which occupational radiation exposure contributes to cancer mortality is an influence on future world energy policy. It is also a factor in deciding the level of expenditure to reduce radiation levels experienced by workers. Here we discuss some of the difficulties in analysing the situation and presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/6/001

    authors: Reissland JA,Kay P,Dolphin GW

    更新日期:1976-11-01 00:00:00

  • A search for improved technique factors in paediatric fluoroscopy.

    abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/018

    authors: Tapiovaara MJ,Sandborg M,Dance DR

    更新日期:1999-02-01 00:00:00

  • Calculation of water equivalent ratios for various materials at proton energies ranging 10-500 MeV using MCNP, FLUKA, and GEANT4 Monte Carlo codes.

    abstract::Dosimetry of proton beams is generally evaluated in liquid water, or alternatively in solid phantoms via water equivalent ratios (WER). WER is defined as the ratio of proton range in liquid water to that in a phantom of certain material. Presently, WER is not available in the literature neither for a wide range of ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad0bd

    authors: Safigholi H,Song WY

    更新日期:2018-07-27 00:00:00

  • Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model.

    abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4364

    authors: Šarolić A,Živković Z,Reilly JP

    更新日期:2016-06-21 00:00:00

  • Mechanical analysis of an axially symmetric cylindrical phantom with a spherical heterogeneity for MR elastography.

    abstract::Cylindrical homogenous phantoms for magnetic resonance (MR) elastography in biomedical research provide one way to validate an imaging systems performance, but the simplified geometry and boundary conditions can cloak complexity arising at tissue interfaces. In an effort to develop a more realistic gel tissue phantom ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6821

    authors: Schwartz BL,Yin Z,Magin RL

    更新日期:2016-09-21 00:00:00

  • Dosimetric characterization of a new miniature multileaf collimator.

    abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/12/402

    authors: Hartmann GH,Föhlisch F

    更新日期:2002-06-21 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • The MLC tongue-and-groove effect on IMRT dose distributions.

    abstract::We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/310

    authors: Deng J,Pawlicki T,Chen Y,Li J,Jiang SB,Ma CM

    更新日期:2001-04-01 00:00:00

  • Radiation binary targeted therapy for HER-2 positive breast cancers: assumptions, theoretical assessment and future directions.

    abstract::A novel radiation targeted therapy is investigated for HER-2 positive breast cancers. The proposed concept combines two known approaches, but never used together for the treatment of advanced, relapsed or metastasized HER-2 positive breast cancers. The proposed radiation binary targeted concept is based on the anti HE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/001

    authors: Mundy DW,Harb W,Jevremovic T

    更新日期:2006-03-21 00:00:00

  • The dosimetric impact of dental implants on head-and-neck volumetric modulated arc therapy.

    abstract::This work aims to investigate the dosimetric impact of dental implants on volumetric modulated arc therapy (VMAT) for head-and-neck patients and to evaluate the effectiveness of using the material's electron-density ratio for the correction. An in-house Monte Carlo (MC) code was utilized for the dose calculation to ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1027

    authors: Lin MH,Li J,Price RA Jr,Wang L,Lee CC,Ma CM

    更新日期:2013-02-21 00:00:00

  • Modified sector-integration method for predicting the output factors of electron beams including extended source to surface distance.

    abstract::A modified sector-integration method is presented that can predict the output factors of irregular shaped electron fields even in the case of extended source to surface distance (SSD). The model takes as input measured output factors for circular inserts of various radii. These circular fields were measured at SSDs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/318

    authors: Choi DR,Wolters J,Mason D,Baillie A

    更新日期:2000-11-01 00:00:00

  • Reassessing the clinical efficacy of two MR quantitative DSC PWI CBF algorithms following cross-calibration with PET images.

    abstract::Clinical cerebral blood flow (CBF) maps generated through dynamic- susceptibility contrast (DSC) magnetic resonance (MR) perfusion imaging are currently cross-calibrated with PET studies. The cross-calibration is achieved by rescaling the MR CBF values so that normal white matter CBF corresponds to 22 ml/100 g/min. Ex...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/6/014

    authors: Chen JJ,Frayne R,Smith MR

    更新日期:2005-03-21 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • A new approach to develop computer-aided detection schemes of digital mammograms.

    abstract::The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/11/4413

    authors: Tan M,Qian W,Pu J,Liu H,Zheng B

    更新日期:2015-06-07 00:00:00

  • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    abstract::A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/014

    authors: Lee SC,Kim HK,Chun IK,Cho MH,Lee SY,Cho MH

    更新日期:2003-12-21 00:00:00

  • Organ and effective doses in newborn patients during helical multislice computed tomography examination.

    abstract::In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/005

    authors: Staton RJ,Lee C,Lee C,Williams MD,Hintenlang DE,Arreola MM,Williams JL,Bolch WE

    更新日期:2006-10-21 00:00:00

  • Estimation of prenatal aorta intima-media thickness from ultrasound examination.

    abstract::Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and child...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0022-3727/59/21/6355

    authors: Veronese E,Tarroni G,Visentin S,Cosmi E,Linguraru MG,Grisan E

    更新日期:2014-11-07 00:00:00

  • Fast and exact Hessian computation for a class of nonlinear functions used in radiation therapy treatment planning.

    abstract::In nonlinear optimisation, using exact Hessian computations (full-Newton) hold superior convergence properties over quasi-Newton methods or gradient-based methods. However, for medium-scale problems, computing the Hessian can be computationally expensive and thus time-consuming. For solvers dedicated to a specific pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1e17

    authors: van Haveren R,Breedveld S

    更新日期:2019-08-14 00:00:00

  • Motion correction of respiratory-gated PET images using deep learning based image registration framework.

    abstract::Artifacts caused by patient breathing and movement during PET data acquisition affect image quality. Respiratory gating is commonly used to gate the list-mode PET data into multiple bins over a respiratory cycle. Non-rigid registration of respiratory-gated PET images can reduce motion artifacts and preserve count stat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8688

    authors: Li T,Zhang M,Qi W,Asma E,Qi J

    更新日期:2020-07-30 00:00:00

  • 4D image reconstruction for emission tomography.

    abstract::An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/22/R371

    authors: Reader AJ,Verhaeghe J

    更新日期:2014-11-21 00:00:00

  • UWB pulse propagation into human tissues.

    abstract::In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and he...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/24/8689

    authors: Cavagnaro M,Pittella E,Pisa S

    更新日期:2013-12-21 00:00:00

  • An alternative to gamma histograms for ROI-based quantitative dose comparisons.

    abstract::An alternative to gamma (gamma) histograms for ROI-based quantitative comparisons of dose distributions using the gamma concept is proposed. The method provides minimum values of dose difference and distance-to-agreement such that a pre-set fraction of the region of interest passes the gamma test. Compared to standard...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N03

    authors: Dvorak P

    更新日期:2009-06-21 00:00:00

  • Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions.

    abstract::Short- and long-term side effects following the treatment of cancer with radiation are strongly related to the amount of dose deposited to the healthy tissue surrounding the tumor. The characterization of the radiation field outside the planned target volume is the first step for estimating health risks, such as devel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/8/2111

    authors: Tessa CL,Berger T,Kaderka R,Schardt D,Burmeister S,Labrenz J,Reitz G,Durante M

    更新日期:2014-04-21 00:00:00

  • The validation of tomotherapy dose calculations in low-density lung media.

    abstract::The dose-calculation accuracy of the tomotherapy Hi-Art II(R) (Tomotherapy, Inc., Madison, WI) treatment planning system (TPS) in the presence of low-density lung media was investigated. In this evaluation, a custom-designed heterogeneous phantom mimicking the mediastinum geometry was used. Gammex LN300 and balsa wood...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/004

    authors: Chaudhari SR,Pechenaya OL,Goddu SM,Mutic S,Rangaraj D,Bradley JD,Low D

    更新日期:2009-04-21 00:00:00

  • On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

    abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/001

    authors: Kissick MW,Flynn RT,Westerly DC,Hoban PW,Mo X,Soisson ET,McCall KC,Mackie TR,Jeraj R

    更新日期:2008-09-21 00:00:00

  • Dielectric characteristics of packed human erythrocytes with haemoglobins F, AA, AS and SS.

    abstract::The radiofrequency dielectric behaviour of packed human erythrocytes has been investigated in normal haemoglobins F and AA and also abnormal haemoglobins homozygous SS and heterozygous AS. Dielectric measurements were made in tightly packed blood cells at an average room temperature of 26.5 +/- 0.5 degrees C in the fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/4/002

    authors: Laogun AA,Ajayi NO,Okafor LO,Osamo NO

    更新日期:1983-04-01 00:00:00

  • Effect of endorectal balloon positioning errors on target deformation and dosimetric quality during prostate SBRT.

    abstract::An inflatable endorectal balloon (ERB) is often used during stereotactic body radiation therapy (SBRT) for treatment of prostate cancer in order to reduce both intrafraction motion of the target and risk of rectal toxicity. However, the ERB can exert significant force on the prostate, and this work assessed the impact...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7995

    authors: Jones BL,Gan G,Kavanagh B,Miften M

    更新日期:2013-11-21 00:00:00

  • Design, construction and use of a large-sample field-cycled PEDRI imager.

    abstract::The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/7/008

    authors: Lurie DJ,Foster MA,Yeung D,Hutchison JM

    更新日期:1998-07-01 00:00:00

  • Staging of cervical cancer based on tumor heterogeneity characterized by texture features on (18)F-FDG PET images.

    abstract::The aim of the study is to assess the staging value of the tumor heterogeneity characterized by texture features and other commonly used semi-quantitative indices extracted from (18)F-FDG PET images of cervical cancer (CC) patients. Forty-two patients suffering CC at different stages were enrolled in this study. First...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5123

    authors: Mu W,Chen Z,Liang Y,Shen W,Yang F,Dai R,Wu N,Tian J

    更新日期:2015-07-07 00:00:00

  • PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.

    abstract::We study the spatial distributions of beta(+)-activity produced by therapeutic beams of (3)He and (12)C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positron-emitting nuclei with T(1/2...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/24/007

    authors: Pshenichnov I,Larionov A,Mishustin I,Greiner W

    更新日期:2007-12-21 00:00:00