Influence of segmentation margin on machine learning-based high-dimensional quantitative CT texture analysis: a reproducibility study on renal clear cell carcinomas.

Abstract:

OBJECTIVE:To determine the possible influence of segmentation margin on each step (feature reproducibility, selection, and classification) of the machine learning (ML)-based high-dimensional quantitative computed tomography (CT) texture analysis (qCT-TA) of renal clear cell carcinomas (RcCCs). MATERIALS AND METHODS:For this retrospective study, 47 patients with RcCC were included from a public database. Two segmentations were obtained by two radiologists for each tumour: (i) contour-focused and (ii) margin shrinkage of 2 mm. Texture features were extracted from original, filtered, and transformed CT images. Feature selection was done using a correlation-based algorithm. The ML classifier was k-nearest neighbours. Classifications were performed with and without using synthetic minority over-sampling technique. Reference standard was nuclear grade (low versus high). Intraclass correlation coefficient (ICC), Pearson's correlation coefficient, Wilcoxon signed-ranks test, and McNemar's test were used in the analysis. RESULTS:The segmentation with margin shrinkage of 2 mm (772 of 828; 93.2%) yielded more texture features with excellent reproducibility (ICC ≥ 0.9) than contour-focused segmentation (714 of 828; 86.2%), p < 0.0001. The feature selection algorithms resulted in different feature subsets for two segmentation datasets with only one common feature. All ML-based models based on contour-focused segmentation (area under the curve [AUC] range, 0.865-0.984) performed better than those with margin shrinkage of 2 mm (AUC range, 0.745-0.887), p < 0.05. CONCLUSIONS:Each step of the ML-based high-dimensional qCT-TA was susceptible to a slight change of 2 mm in segmentation margin. Despite yielding fewer features with excellent reproducibility, use of the contour-focused segmentation provided better classification performance for distinguishing nuclear grade. KEY POINTS:• Each step of a machine learning (ML)-based high-dimensional quantitative computed tomography texture analysis (qCT-TA) is sensitive to even a slight change of 2 mm in segmentation margin. • Despite yielding fewer texture features with excellent reproducibility, performing the segmentation focusing on the outermost boundary of the tumours provides better classification performance in ML-based qCT-TA of renal clear cell carcinomas for distinguishing nuclear grade. • Findings of an ML-based high-dimensional qCT-TA may not be reproducible in clinical practice even using the same feature selection algorithm and ML classifier unless the possible influence of the segmentation margin is considered.

journal_name

Eur Radiol

journal_title

European radiology

authors

Kocak B,Ates E,Durmaz ES,Ulusan MB,Kilickesmez O

doi

10.1007/s00330-019-6003-8

subject

Has Abstract

pub_date

2019-09-01 00:00:00

pages

4765-4775

issue

9

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-019-6003-8

journal_volume

29

pub_type

杂志文章
  • Quantitative CT texture and shape analysis: can it differentiate benign and malignant mediastinal lymph nodes in patients with primary lung cancer?

    abstract:OBJECTIVE:To assess the accuracy of CT texture and shape analysis in the differentiation of benign and malignant mediastinal nodes in lung cancer. METHODS:Forty-three patients with biopsy-proven primary lung malignancy with pathological mediastinal nodal staging and unenhanced CT of the thorax were studied retrospecti...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3420-6

    authors: Bayanati H,E Thornhill R,Souza CA,Sethi-Virmani V,Gupta A,Maziak D,Amjadi K,Dennie C

    更新日期:2015-02-01 00:00:00

  • Perfusion CT in patients with advanced bronchial carcinomas: a novel chance for characterization and treatment monitoring?

    abstract::Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed tab...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2288-2

    authors: Kiessling F,Boese J,Corvinus C,Ederle JR,Zuna I,Schoenberg SO,Brix G,Schmähl A,Tuengerthal S,Herth F,Kauczor HU,Essig M

    更新日期:2004-07-01 00:00:00

  • Comparison between software volumetric breast density estimates in breast tomosynthesis and digital mammography images in a large public screening cohort.

    abstract:OBJECTIVES:To compare software estimates of volumetric breast density (VBD) based on breast tomosynthesis (BT) projections to those based on digital mammography (DM) images in a large screening cohort, the Malmö Breast Tomosynthesis Screening Trial (MBTST). METHODS:DM and BT images of 9909 women (enrolled 2010-2015) w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5582-0

    authors: Förnvik D,Förnvik H,Fieselmann A,Lång K,Sartor H

    更新日期:2019-01-01 00:00:00

  • Effective dose in Albanian direct chest fluoroscopy.

    abstract::In the absence of reliable supplies of X-ray film, direct fluoroscopy is still extensively used in Albania, with chest radiology a particularly common application. This paper aims to quantify both patient skin dose and the risk-related quantity effective dose for direct fluoroscopy units based in seven different Alban...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000462

    authors: Marshall NW,Shehu G,Marsh D,Faulkner K,Malone J,Dewhurst K

    更新日期:2001-01-01 00:00:00

  • Volume of high-risk intratumoral subregions at multi-parametric MR imaging predicts overall survival and complements molecular analysis of glioblastoma.

    abstract:OBJECTIVE:To develop and validate a volume-based, quantitative imaging marker by integrating multi-parametric MR images for predicting glioblastoma survival, and to investigate its relationship and synergy with molecular characteristics. METHODS:We retrospectively analysed 108 patients with primary glioblastoma. The d...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4751-x

    authors: Cui Y,Ren S,Tha KK,Wu J,Shirato H,Li R

    更新日期:2017-09-01 00:00:00

  • Percutaneous vertebroplasty immediately relieves pain of osteoporotic vertebral compression fractures and prevents prolonged immobilization of patients.

    abstract::To assess the immediate efficacy of percutaneous vertebroplasty (PVP) in relief of pain and improving mobility of patients with vertebral compression fractures (VCF) secondary to osteoporosis, 205 cases (175 patients) underwent 250 percutaneous injections of polymethylmethacrylate (PMMA; unilateral, 247 levels; bilate...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2549-0

    authors: Kobayashi K,Shimoyama K,Nakamura K,Murata K

    更新日期:2005-02-01 00:00:00

  • Intravoxel incoherent motion (IVIM) 3 T MRI for orbital lesion characterization.

    abstract:OBJECTIVES:To determine the diagnostic accuracy of MRI intravoxel incoherent motion (IVIM) when characterizing orbital lesions, which is challenging due to a wide range of locations and histologic types. METHODS:This IRB-approved prospective single-center study enrolled participants presenting with an orbital lesion u...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07103-1

    authors: Lecler A,Duron L,Zmuda M,Zuber K,Bergès O,Putterman M,Savatovsky J,Fournier L

    更新日期:2021-01-01 00:00:00

  • Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla.

    abstract::The purpose was to provide a diffusion-weighted whole-body magnetic resonance (MR) imaging sequence with background body signal suppression (DWIBS) at 3.0 Tesla. A diffusion-weighted spin-echo echo-planar imaging sequence was combined with the following methods of fat suppression: short TI inversion recovery (STIR), s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0717-8

    authors: Mürtz P,Krautmacher C,Träber F,Gieseke J,Schild HH,Willinek WA

    更新日期:2007-12-01 00:00:00

  • Radioembolisation with (90)Y-labelled resin microspheres in the treatment of liver metastasis from breast cancer.

    abstract:OBJECTIVES:Metastatic breast cancer is a heterogeneous disease, commonly affecting the liver. We report our experience with (90)Y radioembolisation (RE) and its effects on the survival of patients with treatment-refractory breast cancer liver metastases. METHODS:A total of 77 female patients affected by breast cancer ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2556-5

    authors: Cianni R,Pelle G,Notarianni E,Saltarelli A,Rabuffi P,Bagni O,Filippi L,Cortesi E

    更新日期:2013-01-01 00:00:00

  • Impact of 64-slice coronary CT on the management of patients presenting with acute chest pain: results of a prospective two-centre study.

    abstract:OBJECTIVE:Our two-centre prospective study evaluates the usefulness of 64-slice coronary computed tomography (CCT) to rule out significant coronary artery stenosis in patients admitted in emergency departments (ED) for acute coronary syndromes (ACS) with low-to-intermediate risk score. METHODS:Patients (175) admitted ...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-011-2354-5

    authors: Christiaens L,Duchat F,Boudiaf M,Tasu JP,Fargeaudou Y,Ledref O,Soyer P,Sirol M

    更新日期:2012-05-01 00:00:00

  • Radiological features of healing in newborn clavicular fractures.

    abstract:OBJECTIVES:Given the frequency of abusive fractures among infants, and the lack of research and or evidence for the phases of fracture healing seen in this age group, this study aims to describe a timetable of radiological features of fracture healing among infants in the first months of life. METHODS:We completed a r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4569-y

    authors: Fadell M,Miller A,Trefan L,Weinman J,Stewart J,Hayes K,Maguire S

    更新日期:2017-05-01 00:00:00

  • Quantitative assessment of tumour associated neovascularisation in patients with liver cirrhosis and hepatocellular carcinoma: role of dynamic-CT perfusion imaging.

    abstract:OBJECTIVE:To determine the value of perfusion computed tomography (CT-p) in the quantitative assessment of tumour-related neoangiogenesis processes in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Fifty-two biopsy proven HCC lesions were examined with dynamic CT investigations during injection of...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2307-z

    authors: Ippolito D,Capraro C,Casiraghi A,Cestari C,Sironi S

    更新日期:2012-04-01 00:00:00

  • Gadoxetic acid disodium-enhanced MR imaging of cholangiolocellular carcinoma of the liver: imaging characteristics and histopathological correlations.

    abstract:OBJECTIVES:To review the gadoxetic acid disodium (EOB)-enhanced magnetic resonance (MR) imaging features of cholangiolocellular carcinoma (CoCC) of the liver and compare them with those of hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC). METHODS:EOB-enhanced MR images of 19 patients with CoCC,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4811-2

    authors: Haradome H,Unno T,Morisaka H,Toda Y,Kwee TC,Kondo H,Sano K,Ichikawa T,Kondo F,Sugitani M,Takayama T

    更新日期:2017-11-01 00:00:00

  • Increased epicardial fat is independently associated with the presence and chronicity of atrial fibrillation and radiofrequency ablation outcome.

    abstract:OBJECTIVE:To determine whether intrathoracic fat volumes are associated with presence and chronicity of atrial fibrillation (AF) and radiofrequency ablation (RFA) treatment outcome. METHODS:IRB approval was obtained and patient consent was waived for this HIPAA-compliant retrospective study. 169 patients with AF (75 n...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3643-1

    authors: Stojanovska J,Kazerooni EA,Sinno M,Gross BH,Watcharotone K,Patel S,Jacobson JA,Oral H

    更新日期:2015-08-01 00:00:00

  • Standardizing percutaneous Microwave Ablation in the treatment of Lung Tumors: a prospective multicenter trial (MALT study).

    abstract:OBJECTIVES:To prospectively assess reproducibility, safety, and efficacy of microwave ablation (MWA) in the treatment of unresectable primary and secondary pulmonary tumors. METHODS:Patients with unresectable primary and metastatic lung tumors up to 4 cm were enrolled in a multicenter prospective clinical trial and un...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07299-2

    authors: Iezzi R,Cioni R,Basile D,Tosoratti N,Posa A,Busso M,Cappelli C,Margaritora S,Ambrogi MC,Cassano A,Scandiffio R,Calandri M,Crocetti L,Valentini V,Manfredi R,Veltri A

    更新日期:2020-09-30 00:00:00

  • Future prospects for SonoVue and CPS.

    abstract::Though long considered unlikely because of the resonance pattern of agents such as SonoVue, high frequency applications for small parts and intracavitary applications now seem very promising. Excellent non-linear signals can be obtained at 7 MHz and higher using recently developed CPS software, and preliminary results...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s10406-004-0084-3

    authors: Cosgrove D

    更新日期:2004-10-01 00:00:00

  • Post-imaging pulmonary nodule mathematical prediction models: are they clinically relevant?

    abstract:OBJECTIVES:Post-imaging mathematical prediction models (MPMs) provide guidance for the management of solid pulmonary nodules by providing a lung cancer risk score from demographic and radiologists-indicated imaging characteristics. We hypothesized calibrating the MPM risk score threshold to a local study cohort would r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06168-x

    authors: Uthoff J,Koehn N,Larson J,Dilger SKN,Hammond E,Schwartz A,Mullan B,Sanchez R,Hoffman RM,Sieren JC,COPDGene Investigators.

    更新日期:2019-10-01 00:00:00

  • Automated computer-based CT stratification as a predictor of outcome in hypersensitivity pneumonitis.

    abstract:BACKGROUND:Hypersensitivity pneumonitis (HP) has a variable clinical course. Modelling of quantitative CALIPER-derived CT data can identify distinct disease phenotypes. Mortality prediction using CALIPER analysis was compared to the interstitial lung disease gender, age, physiology (ILD-GAP) outcome model. METHODS:CAL...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4697-4

    authors: Jacob J,Bartholmai BJ,Rajagopalan S,Karwoski R,Mak SM,Mok W,Della Casa G,Sugino K,Walsh SLF,Wells AU,Hansell DM

    更新日期:2017-09-01 00:00:00

  • Ultrasound appearances of the testicular appendages: pictorial review.

    abstract::Five testicular appendages are formed during development of the male genito-urinary tract, which are the remnants of the degenerating mesonephric and paramesonephric ducts. The testicular and epididymal appendages, found at the upper pole of the testis and at the head of the epididymis respectively, are the most commo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1387-1

    authors: Sellars ME,Sidhu PS

    更新日期:2003-01-01 00:00:00

  • The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

    abstract:OBJECTIVES:In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5622-9

    authors: Jeon JY,Lee SW,Jeong YM,Baek HJ

    更新日期:2019-03-01 00:00:00

  • Preoperative T staging of gastric carcinoma obtained by MDCT vessel probe reconstructions and correlations with histological findings.

    abstract::This study aims to evaluate the diagnostic accuracy of 16-row multidetector CT (MDCT) and vessel probe reconstructions in the T staging of gastric carcinoma. Fifty-three patients (39 men, 14 women, mean age 57.5) with an endoscopic diagnosis of gastric adenocarcinoma underwent CT examination. A hypotonic drug was admi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1482-7

    authors: Moschetta M,Stabile Ianora AA,Anglani A,Marzullo A,Scardapane A,Angelelli G

    更新日期:2010-01-01 00:00:00

  • Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation.

    abstract:OBJECTIVES:To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. METHODS:Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered b...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4686-7

    authors: Notohamiprodjo S,Stahl R,Braunagel M,Kazmierczak PM,Thierfelder KM,Treitl KM,Wirth S,Notohamiprodjo M

    更新日期:2017-08-01 00:00:00

  • Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications.

    abstract::Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2236-1

    authors: Reimer P,Schneider G,Schima W

    更新日期:2004-04-01 00:00:00

  • Citations in scientific articles: possibly biased reflections on the field of diagnostic imaging.

    abstract::This Editorial Comment refers to the article "Citation Bias in Imaging Research: Are studies with higher diagnostic accuracy estimates cited more often?" by Frank RA, Sharifabadi AD, Salameh JP et al, Eur Radiol. 2018 Nov 15. https://doi.org/10.1007/s00330-018-5801-8 [1]. ...

    journal_title:European radiology

    pub_type: 评论,社论

    doi:10.1007/s00330-018-5974-1

    authors: Sundermann B

    更新日期:2019-04-01 00:00:00

  • Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with ¹⁵O-H₂O PET.

    abstract:OBJECTIVES:This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery d...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-014-3164-3

    authors: Kikuchi Y,Oyama-Manabe N,Naya M,Manabe O,Tomiyama Y,Sasaki T,Katoh C,Kudo K,Tamaki N,Shirato H

    更新日期:2014-07-01 00:00:00

  • Management of patient dose and image noise in routine pediatric CT abdominal examinations.

    abstract::The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2206-z

    authors: Verdun FR,Lepori D,Monnin P,Valley JF,Schnyder P,Gudinchet F

    更新日期:2004-05-01 00:00:00

  • Meningeal hemangiopericytoma in childhood.

    abstract::Meningeal hemangiopericytoma (MHP) is extremely rare in childhood. Mean age at diagnosis is between 38 and 43 years. We present an 8-year-old boy with MHP of the middle cranial fossa. Imaging findings were indistinguishable from an aggressive bone tumor such as Ewing's sarcoma. Imaging findings are presented and discu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003309900222

    authors: Huisman TA,Brandner S,Niggli F,Kacl G,Willi UV,Martin E

    更新日期:2000-01-01 00:00:00

  • Traumatic injuries: organization and ergonomics of imaging in the emergency environment.

    abstract::Management of trauma patients relies on a simple but obvious concept: Time is life! This is a challenge to the emergency radiologist in his evaluation of the radiological admission survey of severe trauma patients, since the latter need a quick and thorough survey of craniocerebral, cervical, thoracic, abdominal, and ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1385-3

    authors: Wintermark M,Poletti PA,Becker CD,Schnyder P

    更新日期:2002-05-01 00:00:00

  • Correlation of patient survival with clinical tumor measurements in malignant pleural mesothelioma.

    abstract:OBJECTIVES:To evaluate differences in the tumor response classifications that result from clinical measurements and to compare these response classifications with overall survival for patients with malignant pleural mesothelioma (MPM). METHODS:One hundred thirty-one computed tomography (CT) scans were collected from 4...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-018-5887-z

    authors: Li F,Ahmad M,Qayyum F,Straus CM,MacMahon H,Kindler H,Armato SG 3rd

    更新日期:2019-06-01 00:00:00

  • Magnetisation transfer MR imaging of the kidney: evaluation at 3.0 T in association with renal function.

    abstract:OBJECTIVE:To evaluate the feasibility of using magnetisation transfer (MT) MRI of the kidney at 3.0 T to assess renal function. METHODS:Forty-four patients who underwent abdominal MRI on a 3.0-T system including gradient-echo (GRE) sequences with and without MT pulse were included. In each patient, MT ratio (MTR) of t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2841-y

    authors: Ito K,Hayashida M,Izumitani S,Fujimine T,Onishi T,Genba K

    更新日期:2013-08-01 00:00:00