Determination of elemental tissue composition following proton treatment using positron emission tomography.

Abstract:

:Positron emission tomography (PET) has been suggested as an imaging technique for in vivo proton dose and range verification after proton induced-tissue activation. During proton treatment, irradiated tissue is activated and decays while emitting positrons. In this paper, we assessed the feasibility of using PET imaging after proton treatment to determine tissue elemental composition by evaluating the resultant composite decay curve of activated tissue. A phantom consisting of sections composed of different combinations of (1)H, (12)C, (14)N, and (16)O was irradiated using a pristine Bragg peak and a 6 cm spread-out Bragg-peak (SOBP) proton beam. The beam ranges defined at 90% distal dose were 10 cm; the delivered dose was 1.6 Gy for the near monoenergetic beam and 2 Gy for the SOBP beam. After irradiation, activated phantom decay was measured using an in-room PET scanner for 30 min in list mode. Decay curves from the activated (12)C and (16)O sections were first decomposed into multiple simple exponential decay curves, each curve corresponding to a constituent radioisotope, using a least-squares method. The relative radioisotope fractions from each section were determined. These fractions were used to guide the decay curve decomposition from the section consisting mainly of (12)C + (16)O and calculate the relative elemental composition of (12)C and (16)O. A Monte Carlo simulation was also used to determine the elemental composition of the (12)C + (16)O section. The calculated compositions of the (12)C + (16)O section using both approaches (PET and Monte Carlo) were compared with the true known phantom composition. Finally, two patients were imaged using an in-room PET scanner after proton therapy of the head. Their PET data and the technique described above were used to construct elemental composition ((12)C and (16)O) maps that corresponded to the proton-activated regions. We compared the (12)C and (16)O compositions of seven ROIs that corresponded to the vitreous humor, adipose/face mask, adipose tissue, and brain tissue with ICRU 46 elemental composition data. The (12)C and (16)O compositions of the (12)C + (16)O phantom section were estimated to within a maximum difference of 3.6% for the near monoenergetic and SOBP beams over an 8 cm depth range. On the other hand, the Monte Carlo simulation estimated the corresponding (12)C and (16)O compositions in the (12)C + (16)O section to within a maximum difference of 3.4%. For the patients, the (12)C and (16)O compositions in the seven ROIs agreed with the ICRU elemental composition data, with a mean (maximum) difference of 9.4% (15.2%). The (12)C and (16)O compositions of the phantom and patients were estimated with relatively small differences. PET imaging may be useful for determining the tissue elemental composition and thereby improving proton treatment planning and verification.

journal_name

Phys Med Biol

authors

Cho J,Ibbott G,Gillin M,Gonzalez-Lepera C,Min CH,Zhu X,El Fakhri G,Paganetti H,Mawlawi O

doi

10.1088/0031-9155/58/11/3815

subject

Has Abstract

pub_date

2013-06-07 00:00:00

pages

3815-35

issue

11

eissn

0031-9155

issn

1361-6560

journal_volume

58

pub_type

杂志文章
  • Physical modelling of electroporation in close cell-to-cell proximity environments.

    abstract::Many applications of electroporation, especially those utilizing electrofusion and in-vivo electroporation, involve cell environments that include close cell-to-cell proximity and a wide range of target cell size. It is important to understand how this kind of environment may alter optimum electroporation electrical p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/012

    authors: Gaynor PT,Bodger PS

    更新日期:2006-06-21 00:00:00

  • Applicators for generating ultrasound-induced hyperthermia in neoplastic tumours and for use in ultrasound physiotherapy.

    abstract::Ultrasound in the low megahertz frequency range is used by physiotherapists to treat a variety of conditions. The treatments reduce swelling, reduce pain and increase movement at joints. Ultrasound is now also beginning to be used to treat malignant tumours. The tumours are heated to temperatures between 42 degrees an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/11/019

    authors: Quan KM,Shiran M,Watmough DJ

    更新日期:1989-11-01 00:00:00

  • Automated sonographic evaluation of testicular perfusion.

    abstract::Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly deter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/14/010

    authors: Thierman JS,Clement GT,Kalish LA,O'Kane PL,Frauscher F,Paltiel HJ

    更新日期:2006-07-21 00:00:00

  • Comments on 'Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation'.

    abstract::We comment on a previous article by Zhang and Newhauser (2009 Phys. Med. Biol. 54 1383-95) which presents several approximate ways of computing the water equivalent of an arbitrary degrader. First, we present a simple exact method which depends only on the range-energy relation of water and of the degrader material. S...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/55/9/L01

    authors: Gottschalk B

    更新日期:2010-05-07 00:00:00

  • Proton-counting radiography for proton therapy: a proof of principle using CMOS APS technology.

    abstract::Despite the early recognition of the potential of proton imaging to assist proton therapy (Cormack 1963 J. Appl. Phys. 34 2722), the modality is still removed from clinical practice, with various approaches in development. For proton-counting radiography applications such as computed tomography (CT), the water-equival...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2569

    authors: Poludniowski G,Allinson NM,Anaxagoras T,Esposito M,Green S,Manolopoulos S,Nieto-Camero J,Parker DJ,Price T,Evans PM

    更新日期:2014-06-07 00:00:00

  • Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers.

    abstract::Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/316

    authors: Spezi E,Lewis DG,Smith CW

    更新日期:2001-11-01 00:00:00

  • Carbon dioxide reactivity of computed tomography functional parameters in rabbit VX2 soft tissue tumour.

    abstract::Tumour blood flow is one of the important factors limiting the efficacy of radiation therapy (hypoxic radioresistance), chemotherapy (drug delivery) and thermal therapy (heat dissipation) in treating cancer. The modification of tumour blood flow has been an area of intense investigation. In the current study, the arte...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/7/303

    authors: Purdie TG,Lee TY

    更新日期:2003-04-07 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00

  • Calculation of radiation exposures from patients to whom radioactive materials have been administered.

    abstract::Spreadsheet templates which calculate cumulative exposures to other persons from patients to whom radioactive materials have been administered have been developed by the authors. Calculations can be based on any specified single-, bi- or tri-exponential whole-body clearance rate and a diurnal (or any other periodic) c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/3/003

    authors: Cormack J,Shearer J

    更新日期:1998-03-01 00:00:00

  • Wall effects in plane-parallel ionization chambers.

    abstract::All dosimetry protocols recommend the use of plane-parallel chambers for dose determination in electron beams with energies below 10-15 MeV. The protocols have assumed chamber perturbation effects to be negligible. The new AAPM Protocol (TG39) includes a cavity replacement factor prepl that differs from unity for some...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/4/003

    authors: Nilsson B,Montelius A,Andreo P

    更新日期:1996-04-01 00:00:00

  • Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

    abstract::We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization progra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/20/7300

    authors: Xia D,Langan DA,Solomon SB,Zhang Z,Chen B,Lai H,Sidky EY,Pan X

    更新日期:2016-10-21 00:00:00

  • Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications.

    abstract::The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/5/005

    authors: Zoetelief J,Broerse JJ

    更新日期:1983-05-01 00:00:00

  • Global point signature for shape analysis of carpal bones.

    abstract::We present a method based on spectral theory for the shape analysis of carpal bones of the human wrist. We represent the cortical surface of the carpal bone in a coordinate system based on the eigensystem of the two-dimensional Helmholtz equation. We employ a metric--global point signature (GPS)--that exploits the sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/4/961

    authors: Chaudhari AJ,Leahy RM,Wise BL,Lane NE,Badawi RD,Joshi AA

    更新日期:2014-02-21 00:00:00

  • Initial assessment of a simple system for frequency domain diffuse optical tomography.

    abstract::Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/10/011

    authors: Pogue BW,Patterson MS,Jiang H,Paulsen KD

    更新日期:1995-10-01 00:00:00

  • Is it necessary to plan with safety margins for actively scanned proton therapy?

    abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/011

    authors: Albertini F,Hug EB,Lomax AJ

    更新日期:2011-07-21 00:00:00

  • Comparison of temperature distributions in interstitial hyperthermia: experiments in bovine tongues versus generic simulations.

    abstract::Temperature distributions resulting from hyperthermia treatments on isolated perfused bovine tongues were compared with simulations by a treatment planning system. The aim was to test whether the discrete vessel model used for the treatment planning is able to predict correct generic temperature distributions. Tongues...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/011

    authors: Raaymakers BW,Crezee J,Lagendijk JJ

    更新日期:1998-05-01 00:00:00

  • High intensity focused ultrasound for the treatment of rat tumours.

    abstract::Discrete implanted liver tumours in the rat have been exposed to arrays of 1.7 MHz ultrasound lesions. Focal peak intensities in the range 1.4-3.5 k Wcm-2 were used for an exposure time of 10 s. It has been demonstrated that where the whole tumour volume was exposed to the focused ultrasound beam, no evidence of tumou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/11/009

    authors: ter Haar G,Rivens I,Chen L,Riddler S

    更新日期:1991-11-01 00:00:00

  • Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

    abstract::For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of det...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/002

    authors: Sykes JR,Lindsay R,Dean CJ,Brettle DS,Magee DR,Thwaites DI

    更新日期:2008-10-07 00:00:00

  • The induction of hyperthermia by ultrasound; its value and associated problems: II. Scanned-plane transducer.

    abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/12/006

    authors: ter Haar G,Hopewell JW

    更新日期:1985-12-01 00:00:00

  • An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators.

    abstract::A leaf-setting algorithm is developed for generating arbitrary beam intensity profiles in discrete levels using dynamic multileaf collimators (DMLCs). The algorithm starts with the algebraic expression for the area under the beam profile. It is shown that the coefficients in this expression can be transformed into the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/6/019

    authors: Ma L,Boyer AL,Xing L,Ma CM

    更新日期:1998-06-01 00:00:00

  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    abstract::The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling;...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9a2f

    authors: Simon JC,Sapozhnikov OA,Kreider W,Breshock M,Williams JC,Bailey MR

    更新日期:2018-01-09 00:00:00

  • Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system.

    abstract::In the real-time tumor-tracking radiotherapy system, fluoroscopy is used to determine the real-time position of internal fiducial markers. The pattern recognition score (PRS) ranging from 0 to 100 is computed by a template pattern matching technique in order to determine the marker position on the fluoroscopic image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/15/011

    authors: Miyamoto N,Ishikawa M,Bengua G,Sutherland K,Suzuki R,Kimura S,Shimizu S,Onimaru R,Shirato H

    更新日期:2011-08-07 00:00:00

  • Diaphragm correction factors for free-air chamber standards for air kerma in x-rays.

    abstract::At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/009

    authors: Burns DT,Kessler C

    更新日期:2009-05-07 00:00:00

  • Dark-field signal extraction in propagation-based phase-contrast imaging.

    abstract::A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed metho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abac9d

    authors: Gureyev TE,Paganin DM,Arhatari B,Taba ST,Lewis S,Brennan PC,Quiney HM

    更新日期:2020-11-17 00:00:00

  • Dose distribution to spinal structures from intrathecally administered yttrium-90.

    abstract::Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of (131)I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as (90)Y replaces (131)I. The purpose of this study is to compare and quantitatively e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/014

    authors: Mardirossian G,Hall M,Montebello J,Stevens P

    更新日期:2006-01-07 00:00:00

  • An efficient strategy based on an individualized selection of registration methods. Application to the coregistration of MR and SPECT images in neuro-oncology.

    abstract::An efficient registration strategy is described that aims to help solve delicate medical imaging registration problems. It consists of running several registration methods for each dataset and selecting the best one for each specific dataset, according to an evaluation criterion. Finally, the quality of the registrati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6997

    authors: Tacchella JM,Roullot E,Lefort M,Cohen ME,Guillevin R,Petrirena G,Delattre JY,Habert MO,Yeni N,Kas A,Frouin F

    更新日期:2014-11-21 00:00:00

  • Evaluation of quantitative planar 90Y bremsstrahlung whole-body imaging.

    abstract::With high-dose administration of (90)Y labeled antibodies, it is possible to image (90)Y without an admixture of (111)In. We have earlier shown that it is possible to perform quantitative (90)Y bremsstrahlung SPECT for dosimetry purposes with reasonable accuracy. However, whole-body (WB) activity quantification with t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/014

    authors: Minarik D,Ljungberg M,Segars P,Gleisner KS

    更新日期:2009-10-07 00:00:00

  • Changes in optical properties of ex vivo rat prostate due to heating.

    abstract::This study examines the effectiveness of a single, first-order Arrhenius process in accurately modelling the thermally induced changes in the optical properties, particularly the reduced scattering coefficient, mu(s)', and the absorption coefficient, mu(a), of ex vivo rat prostate. Recent work has shown that mu(s)' ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/319

    authors: Skinner MG,Everts S,Reid AD,Vitkin IA,Lilge L,Sherar MD

    更新日期:2000-05-01 00:00:00

  • 19F MRI oximetry: simulation of perfluorocarbon distribution impact.

    abstract::In (19)F MRI oximetry, a method used to image tumour hypoxia, perfluorocarbons serve as oxygenation markers. The goal of this study is to evaluate the impact of perfluorocarbon distribution and concentration in (19)F MRI oximetry through a computer simulation. The simulation studies the correspondence between (19)F me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/013

    authors: Baete SH,Vandecasteele J,De Deene Y

    更新日期:2011-04-21 00:00:00