Wall effects in plane-parallel ionization chambers.

Abstract:

:All dosimetry protocols recommend the use of plane-parallel chambers for dose determination in electron beams with energies below 10-15 MeV. The protocols have assumed chamber perturbation effects to be negligible. The new AAPM Protocol (TG39) includes a cavity replacement factor prepl that differs from unity for some chambers, but assumes that the wall perturbation factor, pwall, may be taken as unity. In this paper the perturbation of the wall has been determined, using a large plane-parallel ionization chamber with exchangeable front and back walls. The results show that in many commercial chambers there is an energy dependent pwall factor, mainly due to differences in backscatter from the often thick chamber body as compared to the phantom material. Backscatter in common phantom and chamber materials may differ by as much as 2% at low electron energies (Plastic Water as compared to polystyrene). The front walls are often thin, resulting in negligible perturbation, but the 0.5 mm front wall of graphite in the NACP chamber was found to increase the response by 0.7% in a PMMA phantom. The experimental results have been compared with EGS4 Monte Carlo calculations using the DOSRZ code. There is an agreement within statistical and experimental uncertainties (0.5%) indicating that it is possible to use Monte Carlo calculations to calculate perturbation factors with good accuracy.

journal_name

Phys Med Biol

authors

Nilsson B,Montelius A,Andreo P

doi

10.1088/0031-9155/41/4/003

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

609-23

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

41

pub_type

杂志文章
  • Online prediction of respiratory motion: multidimensional processing with low-dimensional feature learning.

    abstract::Accurate real-time prediction of respiratory motion is desirable for effective motion management in radiotherapy for lung tumor targets. Recently, nonparametric methods have been developed and their efficacy in predicting one-dimensional respiratory-type motion has been demonstrated. To exploit the correlation among v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/11/002

    authors: Ruan D,Keall P

    更新日期:2010-06-07 00:00:00

  • A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S-values.

    abstract::The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/5/N90

    authors: Tajik-Mansoury MA,Rajabi H,Mozdarani H

    更新日期:2017-03-07 00:00:00

  • Analysis of RF exposure in the head tissues of children and adults.

    abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/019

    authors: Wiart J,Hadjem A,Wong MF,Bloch I

    更新日期:2008-07-07 00:00:00

  • Three-dimensional optical tomography of the premature infant brain.

    abstract::For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/303

    authors: Hebden JC,Gibson A,Yusof RM,Everdell N,Hillman EM,Delpy DT,Arridge SR,Austin T,Meek JH,Wyatt JS

    更新日期:2002-12-07 00:00:00

  • Dielectric studies on the reaction of the intracellular matter of fish red blood cells to detergent toxicity.

    abstract::Results from dielectric studies on the freshwater fish Cyprinus carpio exposed to a sublethal concentration of sodium alkyl benzene sulphonate were compared with those from untreated control fish; recovery from the test solution was also checked. The influence of the anionic detergent on the intracellular matter of fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/005

    authors: Bielinska I,Terlecki J

    更新日期:1984-05-01 00:00:00

  • List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

    abstract::Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this wor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/17/006

    authors: Lamare F,Ledesma Carbayo MJ,Cresson T,Kontaxakis G,Santos A,Le Rest CC,Reader AJ,Visvikis D

    更新日期:2007-09-07 00:00:00

  • Experimental validation of beam quality correction factors for proton beams.

    abstract::This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3207

    authors: Gomà C,Hofstetter-Boillat B,Safai S,Vörös S

    更新日期:2015-04-21 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • Optimization of the accuracy of retention and washout measurements of 99mTc-Sestamibi from breast tumours using an anthropomorphic phantom.

    abstract::Quantifying the retention or washout of (99m)Tc-Sestamibi (MIBI) in breast tumours in vivo may provide a basis for predicting the chemotherapy response. The aim of this study is to investigate the variations and limitations of the different methods used to quantify these parameters. A phantom was developed that allowe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/9/013

    authors: Marshall C,Griffiths PA

    更新日期:2005-05-07 00:00:00

  • Exact analytic reconstruction in x-ray fluorescence CT and approximated versions.

    abstract::X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Rivière (2004 Phys. Med. Biol. 49 2391-405) presented an appr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/007

    authors: Miqueles EX,De Pierro AR

    更新日期:2010-02-21 00:00:00

  • Including robustness in multi-criteria optimization for intensity-modulated proton therapy.

    abstract::We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/3/591

    authors: Chen W,Unkelbach J,Trofimov A,Madden T,Kooy H,Bortfeld T,Craft D

    更新日期:2012-02-07 00:00:00

  • Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator.

    abstract::Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient's breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/11/4300

    authors: O'Brien RT,Stankovic U,Sonke JJ,Keall PJ

    更新日期:2017-06-07 00:00:00

  • Automatic extraction of pectoral muscle in the MLO view of mammograms.

    abstract::A mammogram is the standard modality used for breast cancer screening. Computer-aided detection (CAD) approaches are helpful for improving breast cancer detection rates when applied to mammograms. However, automated analysis of a mammogram often leads to inaccurate results in the presence of the pectoral muscle. There...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/23/8493

    authors: Feudjio CK,Klein J,Tiedeu A,Colot O

    更新日期:2013-12-07 00:00:00

  • Dosimetric accuracy of planning and delivering small proton therapy fields.

    abstract::A detailed Monte Carlo model of a proton therapy treatment head was commissioned to simulate the delivery of small field proton treatments. Small fields are challenging in the planning and quality assurance process because of aperture scattering and dosimetric disequilibrium. Four patients with small fields used in al...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/003

    authors: Bednarz B,Daartz J,Paganetti H

    更新日期:2010-12-21 00:00:00

  • A neural network regression model for relative dose computation.

    abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/307

    authors: Wu X,Zhu Y

    更新日期:2000-04-01 00:00:00

  • The photon calibration of a tissue-equivalent ionisation chamber for neutron dosimetry.

    abstract::The poor agreement in the photon calibrations of tissue-equivalent ionisation chambers between different participants in two major neutron dosimetry intercomparisons is noted. The methods of converting measurements made with a calibrated secondary standard exposure meter to the absorbed dose in the wall of a tissue-eq...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/2/002

    authors: Williams JR,Greening JR

    更新日期:1980-03-01 00:00:00

  • Experimental determination of the energy response of alanine pellets in the high dose rate 192Ir spectrum.

    abstract::An experimental determination of the energy correction factor for alanine/paraffin pellets in the 192Ir spectrum at varying distances from the source is presented. Alanine dosimeters were irradiated in water under full scatter conditions with a high dose rate (HDR) 192Ir source (Flexisource), using a dedicated holder....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/20/007

    authors: Schaeken B,Cuypers R,Goossens J,Van den Weyngaert D,Verellen D

    更新日期:2011-10-21 00:00:00

  • Measurement of the dielectric properties of the epidermis and dermis at frequencies from 0.5 GHz to 110 GHz.

    abstract::Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises sever...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4739

    authors: Sasaki K,Wake K,Watanabe S

    更新日期:2014-08-21 00:00:00

  • Initial assessment of a simple system for frequency domain diffuse optical tomography.

    abstract::Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/10/011

    authors: Pogue BW,Patterson MS,Jiang H,Paulsen KD

    更新日期:1995-10-01 00:00:00

  • The feasibility of using poroelastographic techniques for distinguishing between normal and lymphedematous tissues in vivo.

    abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/013

    authors: Righetti R,Garra BS,Mobbs LM,Kraemer-Chant CM,Ophir J,Krouskop TA

    更新日期:2007-11-07 00:00:00

  • Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    abstract::In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, notice...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/19/003

    authors: Karampatzakis A,Samaras T

    更新日期:2010-10-07 00:00:00

  • Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

    abstract::Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the card...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2813

    authors: Du Y,Bhattacharya M,Frey EC

    更新日期:2014-06-07 00:00:00

  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • The impact of morphology on light transport in cancellous bone.

    abstract::In recent years, optical techniques based on diffusion approximation have demonstrated their ability to gain rich spectral information about bone. However, these methods normally assume homogeneity, while cancellous bone and marrow form a highly heterogeneous two-phase medium. This paper studies the limitations of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/17/003

    authors: Margallo-Balbás E,Taroni P,Pifferi A,Koolstra JH,v Ruijven LJ,French PJ

    更新日期:2010-09-07 00:00:00

  • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

    abstract::We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/9/310

    authors: Ferreira NC,Trébossen R,Lartizien C,Brulon V,Merceron P,Bendriem B

    更新日期:2002-05-07 00:00:00

  • The Akaike information criterion in DCE-MRI: does it improve the haemodynamic parameter estimates?

    abstract::The Akaike information criterion and the associated Akaike weights (AW) rank pharmacokinetic models on the basis of goodness-of-fit and number of parameters. The usefulness of this information for improving the haemodynamic parameter estimates from DCE-MRI was investigated through two examples. In each of these, the e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3609

    authors: Luypaert R,Ingrisch M,Sourbron S,de Mey J

    更新日期:2012-06-07 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Applying a variable relative biological effectiveness (RBE) might affect the analysis of clinical trials comparing photon and proton therapy for prostate cancer.

    abstract::The purpose of this study was the evaluation of the impact of a variable relative biological effectiveness (RBE) compared to a constant RBE value of 1.1 in proton therapy prostate trials due to uncertainties in α/β ratio. Twenty patients receiving passive scattered proton therapy (PSPT) and fifteen patients receiving ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2144

    authors: Marteinsdottir M,Paganetti H

    更新日期:2019-06-05 00:00:00

  • 1D dynamic beam modulation: methods to counteract inertia effects.

    abstract::Dynamic modulation can be affected by inaccuracies when the required acceleration is larger than the highest allowed by the mechanical characteristics of the whole apparatus. In this study, inertia effects have been investigated with regard to the single absorber 1D modulation, analysing primarily how the acceleration...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/401

    authors: Corletto D,Broggi S,Fiorino C,Mangili P,Calandrino R,Lev A,Gennari D,Rudello F

    更新日期:1999-11-01 00:00:00

  • Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment.

    abstract::Fast heat extraction is critically important to obtain the maximal benefit of cryogen spray cooling (CSC) during laser therapy of shallow skin lesions, such as port wine stain birthmarks. However, a film of liquid cryogen can build up on the skin surface, impairing heat transfer due to the relatively low thermal condu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/301

    authors: Majaron B,Svaasand LO,Aguilar G,Nelson JS

    更新日期:2002-09-21 00:00:00