Expanding analytical possibilities concerning the detection of stanozolol misuse by means of high resolution/high accuracy mass spectrometric detection of stanozolol glucuronides in human sports drug testing.

Abstract:

:Anabolic-androgenic steroids (AAS) represent one of the most frequently detected classes of prohibited substances in doping controls. Due to their long-lasting beneficial effects on athletic performance, utmost retrospectivity via urine analysis is desirable and accomplished by targeting long-term metabolites of the respective drugs. In case of stanozolol, a substantial variety of metabolites has enabled the identification of numerous adverse analytical findings in the past, and recent studies concerning complementary phase-I and phase-II metabolites has further expanded the windows of opportunity for detecting the abuse of stanozolol. In this study, the utility of liquid chromatography-high resolution/high accuracy (tandem) mass spectrometry (LC-MS/MS) for the detection of 3'-OH-stanozolol glucuronide in sports drug testing is presented and the identification of two additional and so far unreported metabolites is shown. The structures of the complementary glucuronic acid conjugates were attributed to stanozolol-N-glucuronide and 17-epistanozolol-N-glucuronide. By means of chemical synthesis, stanozolol-N-glucuronide was prepared and used to corroborate the suggested structures. The 3'-OH-stanozolol glucuronide and the newly identified target compounds were implemented into routine sports drug test assays consisting of direct injection LC-MS/MS or solid-phase extraction (SPE) followed by LC-MS/MS. A considerably expanded detection window for stanozolol abuse was demonstrated compared to the use of conventional phase-I metabolites and methodologies based on, for example, low resolution LC-MS/MS or gas chromatography-tandem mass spectrometry (GC-MS/MS). The commercial availability of 3'-OH-stanozolol glucuronide has been of great value for confirmatory purposes, and 17-epistanozolol-N-glucuronide was found to be a favourable long-term metabolite for doping controls as it was observed up to 28 days post-administration of the drug. Applying the established methodology over a period of six months to 659 routine sports drug testing samples, a total of 85 adverse analytical findings was uncovered, 72 of which would have remained undetected using earlier employed GC-MS/MS approaches.

journal_name

Drug Test Anal

authors

Schänzer W,Guddat S,Thomas A,Opfermann G,Geyer H,Thevis M

doi

10.1002/dta.1516

subject

Has Abstract

pub_date

2013-11-01 00:00:00

pages

810-8

issue

11-12

eissn

1942-7603

issn

1942-7611

journal_volume

5

pub_type

杂志文章
  • Chemiluminescence detectors for liquid chromatography.

    abstract::In this tutorial we describe the construction of chemiluminescence detectors for high performance liquid chromatography (HPLC), comprising the components required to deliver the chemiluminescence reagent, a coiled-tubing flow cell, photomultiplier tube and detector housing, and various options for data acquisition. We...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.132

    authors: Adcock JL,Terry JM,Barrow CJ,Barnett NW,Olson DC,Francis PS

    更新日期:2011-03-01 00:00:00

  • Pharmacokinetics of betamethasone in plasma, urine, and synovial fluid following intra-articular administration to exercised thoroughbred horses.

    abstract::The use of corticosteroids, such as betamethasone, in performance horses is tightly regulated. The objective of the current study was to describe the plasma pharmacokinetics of betamethasone as well as time-related urine and synovial fluid concentrations following intra-articular administration to horses. Twelve racin...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2170

    authors: Knych HK,Stanley SD,Harrison LM,Mckemie DS

    更新日期:2017-09-01 00:00:00

  • Detection of formestane abuse by mass spectrometric techniques.

    abstract::Formestane (4-hydroxy-androstenedione) is an aromatase inhibitor prohibited in sports and included, since 2004, in the list of prohibited substances updated yearly by the World Anti-Doping Agency (WADA). Since the endogenous production of formestane has been described, it is mandatory for the anti-doping laboratories ...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.1759

    authors: de la Torre X,Colamonici C,Curcio D,Jardines D,Molaioni F,Parr MK,Botrè F

    更新日期:2014-11-01 00:00:00

  • Analysis of tretoquinol and its metabolites in human urine by liquid chromatography-tandem mass spectrometry.

    abstract::Tretoquinol (trimetoquinol), a β2-agonist, has been explicitly listed on the World Anti-Doping Agency Prohibited List 2019 since January 2019; however, it has been distributed as an antiasthmatic on the medical market. This study aimed to develop a liquid chromatography-tandem mass spectrometric method for the quantif...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2714

    authors: Okano M,Miyamoto A,Sato M,Kageyama S

    更新日期:2019-11-01 00:00:00

  • Effect of single doses of methoxypolyethylene glycol-epoetin beta (CERA, Mircera™) and epoetin delta (Dynepo™) on isoelectric erythropoietin profiles and haematological parameters.

    abstract::Erythropoietin (EPO) has been misused in sports for many years due to its performance-enhancing effect. In the last decade, detection of abuse has been possible with isoelectric focusing (IEF) based on the different isoform profiles of endogenous and recombinant EPO. The release of new EPOs on the market, such as the ...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.270

    authors: Dehnes Y,Hemmersbach P

    更新日期:2011-05-01 00:00:00

  • Simultaneous quantification of digoxin, digitoxin, and their metabolites in serum using high performance liquid chromatography-tandem mass spectrometry.

    abstract::The study describes an LC-MS/MS method for simultaneous quantification of the cardiac glycosidic drugs digoxin and digitoxin and several of their metabolites. The assay represents a useful reference method for immunoassay-based tests, which are easily biased by the presence of metabolites of the target analytes or str...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.1781

    authors: Bylda C,Thiele R,Kobold U,Volmer DA

    更新日期:2015-10-01 00:00:00

  • Prediction of polar surface area of drug molecules: a QSPR approach.

    abstract::A quantitative structure-property relationship (QSPR) study based on an artificial neural network (ANN) was carried out for the prediction of the microemulsion liquid chromatography polar surface area (PSA) of a set of 32 drug compounds. The genetic algorithm-kernel partial least squares (GA-KPLS) method was used as a...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.288

    authors: Noorizadeh H,Farmany A,Noorizadeh M,Kohzadi M

    更新日期:2013-04-01 00:00:00

  • Doping control analysis of anabolic steroids in equine urine by gas chromatography-tandem mass spectrometry.

    abstract::Anabolic steroids are banned substances in equine sports. Gas chromatography-mass spectrometry (GC-MS) has been the traditional technique for doping control analysis of anabolic steroids in biological samples. Although liquid chromatography-mass spectrometry (LC/MS) has become an important technique in doping control,...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2090

    authors: Wong ASY,Leung GNW,Leung DKK,Wan TSM

    更新日期:2017-09-01 00:00:00

  • Nanoparticle technology: amplifying the effective sensitivity of biomarker detection to create a urine test for hGH.

    abstract::Several clinical-grade immunoassays exist for the specific measurement of hGH or its isoforms in blood but there is an urgent need to apply these same reliable assays to the measurement of hGH in urine as a preferred 'non-invasive' biofluid. Unfortunately, conventional hGH immunoassays cannot attain the sensitivity re...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章,评审

    doi:10.1002/dta.96

    authors: Fredolini C,Tamburro D,Gambara G,Lepene BS,Espina V,Petricoin EF 3rd,Liotta LA,Luchini A

    更新日期:2009-09-01 00:00:00

  • PVC membrane sensor for potentiometric determination of iron (II) in some pharmaceutical formulations based on a new neutral ionophore.

    abstract::A novel poly (vinyl chloride) PVC membrane sensor for Fe(2+) ions is described. The sensor is based on the use of newly synthesized chiral 2,6-bis-(carboxamide methyl ester)pyridine derivative as neutral ionophore in plasticized PVC membrane. The sensor display a fast, stable and near-Nernstian response over a relativ...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.231

    authors: Abounassif MA,Al-Omar MA,Amr AG,Mostafa GA

    更新日期:2011-06-01 00:00:00

  • In vivo metabolism of the designer anabolic steroid hemapolin in the thoroughbred horse.

    abstract::Hemapolin (2α,3α-epithio-17α-methyl-5α-androstan-17β-ol) is a designer steroid that is an ingredient in several "dietary" and "nutritional" supplements available online. As an unusual chemical modification to the steroid A-ring could allow this compound to pass through antidoping screens undetected, the metabolism of ...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2769

    authors: Waller CC,Weththasinghe SA,McClure L,Cawley AT,Suann C,Suann E,Sutherland E,Cooper E,Heather A,McLeod MD

    更新日期:2020-06-01 00:00:00

  • Separation of positional isomers of nine 2-phenethylamine-derived designer drugs by liquid chromatography-tandem mass spectrometry.

    abstract::The synthesis of positional isomers of designer drugs is a common way of bypassing legal restrictions. For forensic case work, and especially for the legal assessment of cases, there is a need for screening methods capable of the unequivocal identification of positional isomers. The presented liquid chromatography-ele...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2371

    authors: Grumann C,Auwärter V

    更新日期:2018-02-18 00:00:00

  • A further insight into the metabolic profile of the nuclear receptor Rev-erb agonist, SR9009.

    abstract::The reactions involved in the metabolic pathways of SR9009 were characterized by liquid chromatography-mass spectrometry (LC-MS) to identify the most appropriate marker(s) of use. The effects of gender, genetic polymorphism, and drug-drug interaction on the metabolic profile of SR9009 were also evaluated. In vitro app...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2538

    authors: Mazzarino M,Rizzato N,Stacchini C,de la Torre X,Botrè F

    更新日期:2018-11-01 00:00:00

  • Characterization of in vitro generated metabolites of the selective androgen receptor modulators S-22 and S-23 and in vivo comparison to post-administration canine urine specimens.

    abstract::Selective androgen receptor modulators (SARMs) have great therapeutic potential in various diseases including cancer cachexia, sarcopenia, and osteoporosis, and the number of drug candidates has been growing over the last decade. The SARM drug candidates S-22 and S-23 belong to one of the most advanced groups of andro...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.211

    authors: Thevis M,Gerace E,Thomas A,Beuck S,Geyer H,Schlörer N,Kearbey JD,Dalton JT,Schänzer W

    更新日期:2010-11-01 00:00:00

  • Identification of porcine relaxin in plasma by liquid chromatography-high resolution mass spectrometry.

    abstract::Relaxin (RLX) has demonstrated diverse pharmacological effects in various scientific and clinical studies. The emergence of porcine relaxin (pRLX) has raised concerns on the doping potential of pRLX. There have also been speculations in the horseracing industry on its covert use. To control the abuse of pRLX in equine...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2143

    authors: Wong ASY,Ho ENM,Kwok WH,Leung GNW,Shen Y,Qi RZ,Yue SK,Wan TSM

    更新日期:2017-09-01 00:00:00

  • Updated protocols for the detection of Sotatercept and Luspatercept in human serum.

    abstract::We recently published two protocols for the detection of Sotatercept (ACE-011, ACVR2A-Fc) and Luspatercept (ACE-536, ACVR2B-Fc) in human serum. Both methods used covalently immobilized antibodies on agarose beads for immunoprecipitation and SAR-PAGE/Western blotting for detection. Disadvantages were the relatively hig...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2500

    authors: Reichel C,Gmeiner G,Walpurgis K,Thevis M

    更新日期:2018-11-01 00:00:00

  • An overview of gamma-hydroxybutyric acid: pharmacodynamics, pharmacokinetics, toxic effects, addiction, analytical methods, and interpretation of results.

    abstract::Abuse of gamma-hydroxybutyric acid (GHB) has been known since the early 1990's, but is not as widespread as the consumption of other illegal drugs. However, the number of severe intoxications with fatal outcomes is comparatively high; not the least of which is brought about by the consumption of the currently legal pr...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章,评审

    doi:10.1002/dta.254

    authors: Andresen H,Aydin BE,Mueller A,Iwersen-Bergmann S

    更新日期:2011-09-01 00:00:00

  • Strategy for identification and characterization of small quantities of drug degradation products using LC and LC-MS: application to valsartan, a model drug.

    abstract::The present study demonstrates the applicability of a strategy involving use of liquid chromatography (LC) and liquid chromatography-mass spectrometry (LC-MS) techniques for the identification and characterization of minute quantities of degradation products, without their isolation from the reaction matrix in pure fo...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.116

    authors: Mehta S,Shah RP,Singh S

    更新日期:2010-02-01 00:00:00

  • Cannabinoid disposition in oral fluid after controlled smoked, vaporized, and oral cannabis administration.

    abstract::Oral fluid (OF) is an important matrix for monitoring drugs. Smoking cannabis is common, but vaporization and edible consumption also are popular. OF pharmacokinetics are available for controlled smoked cannabis, but few data exist for vaporized and oral routes. Frequent and occasional cannabis smokers were recruited ...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2092

    authors: Swortwood MJ,Newmeyer MN,Andersson M,Abulseoud OA,Scheidweiler KB,Huestis MA

    更新日期:2017-06-01 00:00:00

  • Altitude training causes haematological fluctuations with relevance for the Athlete Biological Passport.

    abstract::The impact of altitude training on haematological parameters and the Athlete Biological Passport (ABP) was evaluated in international-level elite athletes. One group of swimmers lived high and trained high (LHTH, n = 10) for three to four weeks at 2130 m or higher whereas a control group (n = 10) completed a three-wee...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.1757

    authors: Bonne TC,Lundby C,Lundby AK,Sander M,Bejder J,Nordsborg NB

    更新日期:2015-08-01 00:00:00

  • Metabolic and isotopic signature of short-term DHEA administration in women: Comparison with findings in men.

    abstract::The impact of dehydroepiandrosterone (DHEA) administration has been widely studied for anti-doping purposes in men, whereas only a few studies have been performed in women. In the present study, the impact of DHEA on the steroid profile parameters and their carbon isotopic ratios was explored. Eleven healthy young wom...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2519

    authors: Buisson C,Frelat C,Privat K,Martinat N,Audran M,Collomp K

    更新日期:2018-11-01 00:00:00

  • Assessement of the pharmacokinetics, tissue distribution and excretion studies of a novel antiplatelet agent S007-867, following administration to rats.

    abstract::S007-867 is a promising novel antiplatelet agent with better efficacy and lesser bleeding risk than existing agents. The present study investigated the absorption, tissue distribution, and excretion of S007-867 in rat model for further advancement of the molecule. A simple and robust ultra fast liquid chromatography-t...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.1811

    authors: Chandasana H,Chhonker YS,Laxman TS,Prasad YD,K S AK,Dikshit DK,Bhatta RS

    更新日期:2016-07-01 00:00:00

  • Detection of mono-hydroxylated metabolites of stanozolol by HPLC-ESI (+) MS/MS in Indian sports persons.

    abstract::The abuse of stanozolol is quite widespread in Indian sport. Its analysis is challenging and this has led to the development of new methods to improve its detection. A method was developed and validated for the detection of the three main monohydroxylated metabolites of stanozolol. The excretion profile of these metab...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.76

    authors: Ahi S,Beotra A,Jain S

    更新日期:2009-11-01 00:00:00

  • Identification of ex vivo catabolites of peptides with doping potential in equine plasma by HILIC-HRMS.

    abstract::Bioactive peptides pose a great threat to sports integrity. The detection of these peptides is essential for enforcing their prohibition in sports. Identifying the catabolites of these peptides that are formed ex vivo in plasma may improve their detection. In the present study, the stability of 27 bioactive peptides w...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2781

    authors: Guan F,Fay S,Li X,You Y,Robinson MA

    更新日期:2020-06-01 00:00:00

  • Guidelines for European workplace drug and alcohol testing in hair.

    abstract::Drug and alcohol abuse is a concern for many European companies, especially those having safety-critical jobs. It is not uncommon for European companies to establish a drug policy with little or no provision for drug testing. The European Union (EU) has launched a number of initiatives in its fight against drugs. Ther...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.147

    authors: Agius R,Kintz P,European Workplace Drug Testing Society.

    更新日期:2010-08-01 00:00:00

  • Controlling the misuse of cobalt in horses.

    abstract::Cobalt is a well-established inducer of hypoxia-like responses, which can cause gene modulation at the hypoxia inducible factor pathway to induce erythropoietin transcription. Cobalt salts are orally active, inexpensive, and easily accessible. It is an attractive blood doping agent for enhancing aerobic performance. I...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.1719

    authors: Ho EN,Chan GH,Wan TS,Curl P,Riggs CM,Hurley MJ,Sykes D

    更新日期:2015-01-01 00:00:00

  • Detectability of designer benzodiazepines in CEDIA, EMIT II Plus, HEIA, and KIMS II immunochemical screening assays.

    abstract::The emerging new psychoactive substances made available for recreational drug use have recently started to include designer benzodiazepines. As a consequence, the routine immunoassay drug testing for benzodiazepines may become less effective, due to an increased occurrence of 'false negative' and 'false positive' resu...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.2003

    authors: Pettersson Bergstrand M,Helander A,Hansson T,Beck O

    更新日期:2017-04-01 00:00:00

  • The use of in vitro technologies and high-resolution/accurate-mass LC-MS to screen for metabolites of 'designer' steroids in the equine.

    abstract::Detection of androgenic-anabolic steroid abuse in equine sports requires knowledge of the drug's metabolism in order to target appropriate metabolites, especially where urine is the matrix of choice. Studying 'designer' steroid metabolism is problematic since it is difficult to obtain ethical approval for in vivo meta...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.250

    authors: Clarke A,Scarth J,Teale P,Pearce C,Hillyer L

    更新日期:2011-01-01 00:00:00

  • Seven years of workplace drug testing in Italy: A systematic review and meta-analysis.

    abstract::In Italy, Workplace Drug Testing (WDT) has been compulsory by law for specific categories of workers since 2008, offering the opportunity to compare studies conducted within a single regulatory framework. The aims of this paper are to estimate the overall prevalence of WDT positivity (at screening survey) among Italia...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章,meta分析,评审

    doi:10.1002/dta.2189

    authors: Rosso GL,Montomoli C,Morini L,Candura SM

    更新日期:2017-06-01 00:00:00

  • Drug concentrations in post-mortem femoral blood compared with therapeutic concentrations in plasma.

    abstract::Therapeutic drug concentrations measured in plasma are of limited value as reference intervals for interpretation in post-mortem (PM) toxicology. In this study, drug concentration distributions were studied in PM femoral venous blood from 57 903 Finnish autopsy cases representing all causes of death during an 11-year ...

    journal_title:Drug testing and analysis

    pub_type: 杂志文章

    doi:10.1002/dta.1507

    authors: Launiainen T,Ojanperä I

    更新日期:2014-04-01 00:00:00