Abstract:
PURPOSE:In both structural and functional MRI, there is a need for accurate and reliable automatic segmentation of brain regions. Inconsistent segmentation reduces sensitivity and may bias results in clinical studies. The current study compares the performance of publicly available segmentation tools and their impact on diffusion quantification, emphasizing the importance of using recently developed segmentation algorithms and imaging techniques. METHODS:Four publicly available, automatic segmentation methods (volBrain, FSL, FreeSurfer and SPM) are compared to manual segmentation of the thalamus and hippocampus imaged with a recently proposed T1-weighted MRI sequence (MP2RAGE). We evaluate morphometric accuracy on 22 healthy subjects and impact on diffusivity measurements obtained from aligned diffusion-weighted images on a subset of 10 subjects. RESULTS:Compared to manual segmentation, the highest Dice similarity index of the thalamus is obtained with volBrain using a local library ([Formula: see text], [Formula: see text]) followed by volBrain using an external library ([Formula: see text], [Formula: see text]), FSL ([Formula: see text], [Formula: see text]), FreeSurfer ([Formula: see text], [Formula: see text]) and SPM ([Formula: see text], [Formula: see text]). The same order is found for hippocampus with volBrain local ([Formula: see text], [Formula: see text]), volBrain external ([Formula: see text], [Formula: see text]), FSL ([Formula: see text], [Formula: see text]), FreeSurfer ([Formula: see text], [Formula: see text]) and SPM ([Formula: see text], [Formula: see text]). For diffusivity measurements, volBrain provides values closest to those obtained from manual segmentations. volBrain is the only method where FA values do not differ significantly from manual segmentation of the thalamus. CONCLUSIONS:Overall we find that volBrain is superior in thalamus and hippocampus segmentation compared to FSL, FreeSurfer and SPM. Furthermore, the choice of segmentation technique and training library affects quantitative results from diffusivity measures in thalamus and hippocampus.
journal_name
Int J Comput Assist Radiol Surgauthors
Næss-Schmidt E,Tietze A,Blicher JU,Petersen M,Mikkelsen IK,Coupé P,Manjón JV,Eskildsen SFdoi
10.1007/s11548-016-1433-0subject
Has Abstractpub_date
2016-11-01 00:00:00pages
1979-1991issue
11eissn
1861-6410issn
1861-6429pii
10.1007/s11548-016-1433-0journal_volume
11pub_type
杂志文章abstract:PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpo...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0534-4
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:Sharing of medical data is crucial for the proper treatment of patients as it could reduce the risk of duplicated medical tests and speed up the care process if all documents are readily available. Despite great technical progress, sharing patient data while maintaining full control over the process in an inter...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1819-2
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:Computer-aided detection (CAD) systems are developed to help radiologists detect colonic polyps over CT scans. It is possible to reduce the detection time and increase the detection accuracy rates by using CAD systems. In this paper, we aimed to develop a fully integrated CAD system for automated detection of p...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1521-9
更新日期:2017-04-01 00:00:00
abstract:PURPOSE:This paper presents new quantitative data on a signal-to-noise ratio (SNR) study, distortion study, and targeting accuracy phantom study for our patient-mounted robot (called Arthrobot). Arthrobot was developed as an MRI-guided needle placement device for diagnostic and interventional procedures such as arthrog...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1839-y
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:This article investigates the current state of the art of the use of auditory display in image-guided medical interventions. Auditory display is a means of conveying information using sound, and we review the use of this approach to support navigated interventions. We discuss the benefits and drawbacks of publi...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章,评审
doi:10.1007/s11548-017-1547-z
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:Accurate target delineation is a critical step in radiotherapy. In this study, a robust contour propagation method is proposed to help physicians delineate lung tumors in four-dimensional computer tomography (4D-CT) images efficiently and accurately. METHODS:The proposed method starts with manually delineated ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1457-5
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:Image-guided surgery systems are limited by registration error, so practical and effective methods to improve accuracy are necessary. A projection point-based method for reducing the surface registration error in image-guided surgery was developed and tested. METHODS:Checkerboard patterns are projected on visi...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1075-z
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:In surgical navigation, pre-operative organ models are presented to surgeons during the intervention to help them in efficiently finding their target. In the case of soft tissue, these models need to be deformed and adapted to the current situation by using intra-operative sensor data. A promising method to rea...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01965-7
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:Periacetabular osteotomies are a family of surgical procedures used to treat hip dysplasia. In a periacetabular osteotomy, the operating surgeon aims to increase acetabular coverage of the femoral head. The surgical correction has mechanical goals of increasing the stability of the joint and to improving the pr...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-011-0641-x
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVE:The identification of the interhemispheric fissure (IF) is important in clinical applications for brain landmark identification, registration, symmetry assessment, and pathology detection. The IF is usually approximated by the midsagittal plane (MSP) separating the brain into two hemispheres. We present a fas...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0366-2
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Despite great advances in medical image segmentation, the accurate and automatic segmentation of endoscopic scenes remains a challenging problem. Two important aspects have to be considered in segmenting an endoscopic scene: (1) noise and clutter due to light reflection and smoke from cutting tissue, and (2) st...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1331-x
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:The remote medical diagnosis system (RMDS) is for providing medical diagnosis to the patients located in remote sites. To apply to RMDS and medical automation, many master-slave type ultrasound scanning robots are being developed and researched. One of the important research issue of the master-slave type ultra...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01915-3
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:Many diagnostic or treatment planning applications critically depend on the successful localization of bony structures in CT images. Manual or semiautomatic bone segmentation is tedious, however, and often not practical in clinical routine. In this paper, we present a reliable and fully automatic bone segmentat...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1883-7
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS:The algorithm splits original frame seq...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01926-0
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:This paper presents a method to use the Smart Trocars-our new surgical instrument recognition system-or any accurate localization system of surgical instrument for acquiring intraoperative surface data. Complex laparoscopic surgeries need a proper guidance system which requires registering the preoperative data...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1655-9
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:Surgical phase recognition using sensor data is challenging due to high variation in patient anatomy and surgeon-specific operating styles. Segmenting surgical procedures into constituent phases is of significant utility for resident training, education, self-review, and context-aware operating room technologie...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1409-0
更新日期:2016-06-01 00:00:00
abstract:PURPOSE: Most of the current Bonebridge surgeries undergo preoperative simulation planning in a computer. However, surgeons usually use the landmarks on the bone surface to determine the location where to implant the device, using the simulation image in the computer only as a reference (conventional method). We deve...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0973-9
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:Segmentation of the liver from abdominal computed tomography (CT) images is an essential step in some computer-assisted clinical interventions, such as surgery planning for living donor liver transplant, radiotherapy and volume measurement. In this work, we develop a deep learning algorithm with graph cut refin...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1467-3
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:Laparoscopic ultrasound (LUS) enhances the safety of laparoscopic liver resection by enabling real-time imaging of internal structures such as vessels. However, LUS probes can be difficult to use, and many tumours are iso-echoic and hence are not visible. Registration of LUS to a pre-operative CT or MR scan has...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1799-2
更新日期:2018-08-01 00:00:00
abstract:PURPOSE:The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most tech...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02021-0
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To assess retrospectively the clinical accuracy of an magnetic resonance imaging-guided robotic prostate biopsy system that has been used in the US National Cancer Institute for over 6 years. METHODS:Series of 2D transverse volumetric MR image slices of the prostate both pre (high-resolution T2-weighted)- and ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0831-9
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:Facet joint insertion is a common treatment of chronic pain in the back and spine. This procedure is often performed under fluoroscopic guidance, where the staff's repetitive radiation exposure remains an unsolved problem. Robotic ultrasound (rUS) has the potential to reduce or even eliminate the use of radiati...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1759-x
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Minimally invasive aortic valve replacement (MIAVR) procedures remain more complex and technically challenging compared to conventional full sternotomy surgery. This technique involves a restricted surgical field and a limited workspace, which is, at present, strictly reserved for the most experienced surgeons....
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1725-7
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:Quantitative assessment of surgical skills is an important aspect of surgical training; however, the proposed metrics are sometimes difficult to interpret and may not capture the stylistic characteristics that define expertise. This study proposes a methodology for evaluating the surgical skill, based on metr...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1738-2
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:In image-guided surgery for glioma removal, neurosurgeons usually plan the resection on images acquired before surgery and use them for guidance during the subsequent intervention. However, after the surgical procedure has begun, the preplanning images become unreliable due to the brain shift phenomenon, caused...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02045-6
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:Interventions at the otobasis operate in the narrow region of the temporal bone where several highly sensitive organs define obstacles with minimal clearance for surgical instruments. Nonlinear trajectories for potential minimally invasive interventions can provide larger distances to risk structures and optimi...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1712-z
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. METHOD:A convenient and efficient calibration phantom is designed by combining...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1347-2
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:The interaction with interventional imaging systems within a sterile environment is a challenging task for physicians. Direct physician-machine interaction during an intervention is rather limited because of sterility and workspace restrictions. METHODS:We present a gesture-controlled projection display that e...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1215-0
更新日期:2016-01-01 00:00:00
abstract:OBJECTIVE:For planning surgical interventions at the spine affected by osteoporosis, accurate information about the local bone quality in terms of anchorage strength for implants is very important. Based on previous work on automated bone quality assessment on the proximal femur with a completely automated model-based ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0287-0
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:The favored treatment for many hip fractures is a sliding hip screw, and its usage is expected to increase in the future. Failures can be reduced, and complications detected earlier by semi-automated CT image analysis. The most frequent failure is due to the screw cut-out from the femoral head. METHODS:An imag...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0498-4
更新日期:2010-09-01 00:00:00