Pancreatic acinar cell carcinoma with subcutaneous and intraosseous fat necrosis.

Abstract:

:On rare occasions, excessive lipase production by functioning pancreatic acinar cell carcinoma results in subcutaneous and intraosseous fat necrosis. A patient with subcutaneous nodules and osteolytic lesions from metastatic fat necrosis associated with this malignancy is reported. Prompt recognition of the syndrome led to complete resection of the otherwise asymptomatic neoplasm of the exocrine pancreas.

journal_name

Radiology

journal_title

Radiology

authors

Radin DR,Colletti PM,Forrester DM,Tang WW

doi

10.1148/radiology.158.1.3940400

subject

Has Abstract

pub_date

1986-01-01 00:00:00

pages

67-8

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

158

pub_type

杂志文章
  • Comparison of nonenhanced MR angiographic subtraction techniques for infragenual arteries at 1.5 T: a preliminary study.

    abstract:PURPOSE:To evaluate diagnostic performance of three nonenhanced methods: variable-refocusing-flip angle (FA) fast spin-echo (SE)-based magnetic resonance (MR) angiography (variable FA MR) and constant-refocusing-FA fast SE-based MR angiography (constant-FA MR) and flow-sensitive dephasing (FSD)-prepared steady-state fr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12120859

    authors: Lim RP,Fan Z,Chatterji M,Baadh A,Atanasova IP,Storey P,Kim DC,Kim S,Hodnett PA,Ahmad A,Stoffel DR,Babb JS,Adelman MA,Xu J,Li D,Lee VS

    更新日期:2013-04-01 00:00:00

  • Lymphographic Demonstration of a Retroperitoneal Lymphangioma.

    abstract::Lymphangiomas are rare, benign tumors which may become opacified during lymphography and may be confused with malignant lymph node disease. A case is reported in which lymphography showed focal collections of contrast material retained for several days in dilated lymphatic spaces which initially simulated metastatic d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.2.355

    authors: Castellino RA,Finkelstein S

    更新日期:1975-05-01 00:00:00

  • Proton imaging for medical applications.

    abstract::In order to demonstrate the potential advantages of proton imaging for medical use, a 205-MeV proton beam was developed using the Argonne National Laboratory Booster I synchrotron. Data were taken using a narrow scanning beam and an electronic detector system. The dose reduction and an improved mass resulution over th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.2.6245430

    authors: Kramer SL,Moffett DR,Martin RL,Colton EP,Steward VW

    更新日期:1980-05-01 00:00:00

  • Duplex ultrasound imaging: vascular applications.

    abstract::A recently developed duplex ultrasonic imaging system that combines high-resolution real-time imaging with simultaneous Doppler analysis provides accurate evaluation of hemodynamically significant occlusive vascular lesions. This system was used in the evaluation of the extracranial carotid arteries, iliofemoral arter...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.2.6691110

    authors: Wetzner SM,Kiser LC,Bezreh JS

    更新日期:1984-02-01 00:00:00

  • Detection of choledocholithiasis: comparison of unenhanced helical CT and endoscopic retrograde cholangiopancreatography.

    abstract:PURPOSE:To compare unenhanced helical computed tomography (CT) and endoscopic retrograde cholangiopancreatography (ERCP) in the detection of common bile duct calculi. MATERIALS AND METHODS:Within 13 months, 51 patients (aged 18-94 years) with clinically suspected choledocholithiasis underwent unenhanced helical CT imm...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.3.9169700

    authors: Neitlich JD,Topazian M,Smith RC,Gupta A,Burrell MI,Rosenfield AT

    更新日期:1997-06-01 00:00:00

  • Transcatheter fiberoptic laser coagulation of blood vessels.

    abstract::In ten rabbit ears the central auricular artery was percutaneously catheterized and subjected to doses of laser energy transmitted through a flexible optical fiber within the artery. Arterial occlusion was not produced in the initial three ears using energy levels less than 600 mW. Higher levels of laser energy, in th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.142.3.7199750

    authors: O'Reilly GV,Colucci VM,Astorian DG,Schoene WC,Clarke RH,Hammerschlag SB

    更新日期:1982-03-01 00:00:00

  • A technique for the estimation of fractional moving blood volume by using three-dimensional power Doppler US.

    abstract:PURPOSE:To (a) demonstrate an image-processing method that can automatically measure the power Doppler signal in a three-dimensional ( 3D three-dimensional ) ultrasonographic (US) volume by using the location of organs within the image and (b) compare 3D three-dimensional fractional moving blood volume ( FMBV fractiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132363

    authors: Stevenson GN,Collins SL,Welsh AW,Impey LW,Noble JA

    更新日期:2015-01-01 00:00:00

  • Multiphase CT Angiography Improves Prediction of Intracerebral Hemorrhage Expansion.

    abstract::Purpose To determine the prevalence of the spot sign and the accuracy of using the spot sign to predict intracerebral hemorrhage (ICH) expansion with standardized multiphase computed tomographic (CT) angiography. Materials and Methods This prospective observational cohort study included 123 consecutive patients with a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162839

    authors: Rodriguez-Luna D,Coscojuela P,Rodriguez-Villatoro N,Juega JM,Boned S,Muchada M,Pagola J,Rubiera M,Ribo M,Tomasello A,Demchuk AM,Goyal M,Molina CA

    更新日期:2017-12-01 00:00:00

  • Brain MR imaging at ultra-low radiofrequency power.

    abstract:PURPOSE:To explore the lower limits for radiofrequency (RF) power-induced specific absorption rate (SAR) achievable at 1.5 T for brain magnetic resonance (MR) imaging without loss of tissue signal or contrast present in high-SAR clinical imaging in order to create a potentially viable MR method at ultra-low RF power to...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11092445

    authors: Sarkar SN,Alsop DC,Madhuranthakam AJ,Busse RF,Robson PM,Rofsky NM,Hackney DB

    更新日期:2011-05-01 00:00:00

  • Fast short-tau inversion-recovery MR imaging.

    abstract::To enhance the versatility of the short-tau inversion-recovery (STIR) sequences, the authors determined a range of repetition time (TR) and inversion time (TI) combinations that suppress signal intensity from fat by study of both patient and phantom images. To make fast STIR images, variations in the following pulsing...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014300

    authors: Fleckenstein JL,Archer BT,Barker BA,Vaughan JT,Parkey RW,Peshock RM

    更新日期:1991-05-01 00:00:00

  • Glass-Fiber-based MR-safe Guidewire for MR Imaging-guided Endovascular Interventions: In Vitro and Preclinical in Vivo Feasibility Study.

    abstract::Purpose To evaluate glass-fiber-based guidewires that are safe for magnetic resonance (MR) imaging-guided endovascular interventions by using a phantom and an in vivo swine model. Materials and Methods MR imaging-safe guidewires were made from micropultruded glass and/or aramid fibers and epoxy resin with diameters of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017152742

    authors: Massmann A,Buecker A,Schneider GK

    更新日期:2017-08-01 00:00:00

  • A pattern recognition method for the removal of streaking artifact in computed tomography.

    abstract::A new method is presented for the removal of streaking artifact in computed tomography. The method uses a nearest-neighbor pattern recognition technique to redetermine ray sums that intersect the foreign object responsible for the streaking. When the method is applied to the removal of streaking artifact caused by lea...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.1.7291530

    authors: Morin RL,Raeside DE

    更新日期:1981-10-01 00:00:00

  • Advanced fibrosis: Correlation between pharmacokinetic parameters at dynamic gadoxetate-enhanced MR imaging and hepatocyte organic anion transporter expression in rat liver.

    abstract:PURPOSE:To compare the value of enhancement and pharmacokinetic parameters measured at dynamic gadoxetate-enhanced magnetic resonance (MR) imaging in determining hepatic organic anion transporter expression in control rats and rats with advanced liver fibrosis. MATERIALS AND METHODS:Institutional animal review board a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140313

    authors: Lagadec M,Doblas S,Giraudeau C,Ronot M,Lambert SA,Fasseu M,Paradis V,Moreau R,Pastor CM,Vilgrain V,Daire JL,Van Beers BE

    更新日期:2015-02-01 00:00:00

  • When does a radiologist's recommendation for follow-up result in high-cost imaging?

    abstract:PURPOSE:To measure the proportion of high-cost imaging generated by a radiologist's recommendation and to identify the imaging findings resulting in follow-up. MATERIALS AND METHODS:This retrospective HIPAA-compliant study had institutional review board approval, with waiver of informed consent. A recommended examinat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11111091

    authors: Lee SI,Krishnaraj A,Chatterji M,Dreyer KJ,Thrall JH,Hahn PF

    更新日期:2012-02-01 00:00:00

  • Timeliness of follow-up after abnormal screening mammogram: variability of facilities.

    abstract:PURPOSE:To describe the timeliness of follow-up care in community-based settings among women who receive a recommendation for immediate follow-up during the screening mammography process and how follow-up timeliness varies according to facility and facility-level characteristics. MATERIALS AND METHODS:This was an inst...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11102472

    authors: Rosenberg RD,Haneuse SJ,Geller BM,Buist DS,Miglioretti DL,Brenner RJ,Smith-Bindman R,Taplin SH,Breast Cancer Surveillance Consortium.

    更新日期:2011-11-01 00:00:00

  • Pilonidal sinus disease: MR imaging distinction from fistula in ano.

    abstract:PURPOSE:To describe magnetic resonance (MR) imaging features in patients with proved pilonidal sinus disease and to compare these features with those in a matched group of patients with proved fistula in ano to determine the accuracy with which MR imaging can be used to distinguish between the two diseases. MATERIALS ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2263011758

    authors: Taylor SA,Halligan S,Bartram CI

    更新日期:2003-03-01 00:00:00

  • Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.

    abstract::Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2333030826

    authors: Hofmann LK,Zou KH,Costello P,Schoepf UJ

    更新日期:2004-12-01 00:00:00

  • Computer-aided detection in screening mammography: variability in cues.

    abstract:PURPOSE:To evaluate the variability of true-positive and false-positive cues by using a commercially available computer-aided detection (CAD) system for analysis of 50 malignancies in a screening population. MATERIALS AND METHODS:Fifty breast cancers detected at screening were analyzed by using a commercially availabl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2332031200

    authors: Baker JA,Lo JY,Delong DM,Floyd CE

    更新日期:2004-11-01 00:00:00

  • Flexible tantalum stents for the treatment of iliac artery lesions: long-term patency, complications, and risk factors.

    abstract:PURPOSE:To evaluate the long-term success of tantalum stents implanted in iliac artery lesions and to determine potential predictive factors of early and late stent failure. MATERIALS AND METHODS:In 289 patients, flexible tantalum stents were implanted in iliac artery stenoses (n - 223) or occlusions (n - 66). Early a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.3.8637980

    authors: Strecker EP,Boos IB,Hagen B

    更新日期:1996-06-01 00:00:00

  • Development of the human cerebellum observed with high-field-strength MR imaging.

    abstract::A retrospective study of 160 pediatric subjects, aged 32-410 weeks after conception, was conducted to determine the normal developmental patterns of the human cerebellum by means of magnetic resonance (MR) imaging. On the basis of axial T2-weighted spin-echo images (repetition time, 3,000 msec; echo time, 120 msec), w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.2.2217780

    authors: Stricker T,Martin E,Boesch C

    更新日期:1990-11-01 00:00:00

  • Preparation of 52Fe and its use in a 52Fe/52mMn generator.

    abstract::Clinically useful quantities of 52Fe have been prepared at the Brookhaven Linac Isotope Producer (BLIP) by bombarding manganese or nickel targets with medium energy protons. After chemical separation, 52Fe is loaded onto a generator column from which carrier-free 52Mn is eluted. The 52mMn generator is potentially usef...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.475

    authors: Ku TH,Richards P,Stang LG Jr,Prach T

    更新日期:1979-08-01 00:00:00

  • Intracranial tuberculoma.

    abstract::Intracranial tuberculoma was studied by computed tomography (CT) in eight patients. Upon contrast enhancement, two patterns were seen: (a) a small enhancing ring with a central punctate lucent area, and (b) nodular enhancement. The various CT findings are correlated with the clinical features and with the appearance o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.138.1.7455100

    authors: Whelan MA,Stern J

    更新日期:1981-01-01 00:00:00

  • Lipid in renal clear cell carcinoma: detection on opposed-phase gradient-echo MR images.

    abstract:PURPOSE:To determine if comparison of in-phase and opposed-phase gradient-echo magnetic resonance (MR) images enables detection of lipid in renal clear cell carcinoma. MATERIALS AND METHODS:A retrospective search of MR and pathologic records identified 43 patients with biopsy-proved renal masses who underwent in-phase...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.1.9314970

    authors: Outwater EK,Bhatia M,Siegelman ES,Burke MA,Mitchell DG

    更新日期:1997-10-01 00:00:00

  • Percutaneous image-guided cutting-needle biopsy of the pleura in the presence of a suspected malignant effusion.

    abstract:PURPOSE:To evaluate the diagnostic accuracy of percutaneous image-guided cutting-needle biopsy of pleural thickening in the presence of a suspected malignant pleural effusion. MATERIALS AND METHODS:Thirty-three adult patients with diffuse or focal pleural thickening (median, 1.0 cm; range, 0.2-6.0 cm), pleural effusio...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.2.r01ma07510

    authors: Adams RF,Gleeson FV

    更新日期:2001-05-01 00:00:00

  • Sports-related muscle injuries: evaluation with MR imaging.

    abstract::Sports-related muscle pain is frequent in both trained and untrained persons; however, its severity and significance may be difficult to assess clinically. The authors used magnetic resonance (MR) imaging to evaluate acute strains and delayed-onset muscle soreness in sedentary subjects and postmarathon myalgia in trai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.3.2772190

    authors: Fleckenstein JL,Weatherall PT,Parkey RW,Payne JA,Peshock RM

    更新日期:1989-09-01 00:00:00

  • Rectal biopsy as a cause of rectal ulceration.

    abstract::We report three patients in whom the performance of a rectal biopsy produced an ulcer that was found during a subsequent examination (two at double-contrast barium enema examinations and one at colonoscopy). In each case, the iatrogenic ulcers presented an unusual appearance and resulted in the performance of inapprop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.1.4001420

    authors: Millward SF,Chapman A,Somers S,Stevenson GW

    更新日期:1985-07-01 00:00:00

  • Renal allograft accumulation of Tc-99m sulfur colloid: temporal quantitation and scintigraphic assessment.

    abstract::Renal allograft accumulation of Tc-99m sulfur colloid (TSC) was studied using visual assessment of scintigraphic displays and a quantitative temporal model in 210 examinations of 56 transplant recipients. The quantitative temporal model related the immediate pool of the radioagent in the transplant to the fixed allogr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6346390

    authors: George EA,Meyerovitz M,Codd JE,Fletcher JW,Donati RM

    更新日期:1983-08-01 00:00:00

  • Electromagnetic heating of breast tumors in interventional radiology: in vitro and in vivo studies in human cadavers and mice.

    abstract:PURPOSE:To assess relevant parameters for the minimally invasive elimination of breast tumors by using a selective application of magnetite and exposure of the breast to an alternating magnetic field. MATERIALS AND METHODS:The specific absorption rate (SAR) of different magnetite samples was determined calorimetricall...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.2.r01fe19570

    authors: Hilger I,Andrä W,Hergt R,Hiergeist R,Schubert H,Kaiser WA

    更新日期:2001-02-01 00:00:00

  • Positive predictive value of BI-RADS MR imaging.

    abstract:PURPOSE:To evaluate the positive predictive values (PPVs) of Breast Imaging and Reporting Data Systems (BI-RADS) assessment categories for breast magnetic resonance (MR) imaging and to identify the BI-RADS MR imaging lesion features most predictive of cancer. MATERIALS AND METHODS:This institutional review board-appro...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.12110619

    authors: Mahoney MC,Gatsonis C,Hanna L,DeMartini WB,Lehman C

    更新日期:2012-07-01 00:00:00

  • Usual interstitial pneumonia: correlation of CT with clinical, functional, and radiologic findings.

    abstract::Correlation between disease extent on computed tomographic (CT) scans and severity of clinical and functional impairment was obtained in 23 patients with usual interstitial pneumonia (UIP) by review of the clinical data, pulmonary function tests, chest radiographs, and CT scans. The CT scans and chest radiographs were...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.2.3797650

    authors: Staples CA,Müller NL,Vedal S,Abboud R,Ostrow D,Miller RR

    更新日期:1987-02-01 00:00:00