Glass-Fiber-based MR-safe Guidewire for MR Imaging-guided Endovascular Interventions: In Vitro and Preclinical in Vivo Feasibility Study.

Abstract:

:Purpose To evaluate glass-fiber-based guidewires that are safe for magnetic resonance (MR) imaging-guided endovascular interventions by using a phantom and an in vivo swine model. Materials and Methods MR imaging-safe guidewires were made from micropultruded glass and/or aramid fibers and epoxy resin with diameters of 0.89 mm (0.035 inch) for standard and stiff guidewires and 0.36 mm (0.014 inch) for micro guidewires. MR imaging visibility and mechanical properties were assessed in a pulsatile flow model. After approval was obtained from the institutional animal care and use committee, MR imaging guidewires were evaluated for standard endovascular procedures in nine pigs. Real-time steady-state free-precession sequences were used for MR imaging-guided catheterization, balloon dilation, and stent implantation into aorto-iliac/visceral arteries and the vena cava (temporal resolution, five images per second; and spatial resolution, 150-mm field of view, and 128 × 128 matrix) with a 1.5-T clinical imager. Visualization with the guidewires was rated on a four-point scale, handling was rated on a three-point scale, and catheterization times for different vessel regions were determined by two interventional radiologists. Afterward, handling ratings and catheterization times were obtained for standard nitinol guidewires during x-ray-based fluoroscopy. Cannulation times, signal intensity in each vessel region, and visualization and handling ratings were measured for the MR imaging guidewires. Bland-Altman analysis was performed for inter- and intraobserver variability of cannulation time. Spearman rank correlation was used to compare handling of MR imaging guidewires and standard nitinol guidewires. Results MR imaging guidewires were characterized by good to excellent visibility, with a continuous artifact of 2 mm in diameter and 4 × 8-mm ball-shaped tip marker. Stiffness, flexibility, and guidance reflected comparable times for all in vitro and in vivo procedures with both the MR imaging and standard nitinol guidewires. Standard and micro MR imaging guidewires were most suitable for the iliac crossover maneuver. Phantom visceral artery cannulation was easier with standard and micro MR imaging guidewires. The stiff MR imaging guidewire provided the best support for cannulation of the swine aorta and vena cava. All interventional procedures were performed successfully without complications. Conclusion Preliminary results showed that the use of glass-fiber-based guidewires for evaluation of MR imaging-guided endovascular interventions is technically feasible and safe in a swine model, and potentially, in humans. © RSNA, 2017 Online supplemental material is available for this article.

journal_name

Radiology

journal_title

Radiology

authors

Massmann A,Buecker A,Schneider GK

doi

10.1148/radiol.2017152742

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

541-551

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

284

pub_type

杂志文章
  • Hepatic perfusion disorder associated with focal liver lesions: contrast-enhanced US patterns--correlation study with contrast-enhanced CT.

    abstract:PURPOSE:To retrospectively compare the detection and characterization of hepatic perfusion disorder (HPD) associated with focal liver lesions (FLLs) at contrast material-enhanced ultrasonography (US) by using contrast-enhanced computed tomography (CT) as the reference standard. MATERIALS AND METHODS:The study was appr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101454

    authors: Zhou X,Luo Y,Peng YL,Cai W,Lu Q,Lin L,Sha XX,Li YZ,Zhu M

    更新日期:2011-07-01 00:00:00

  • Inflammatory fibroid polyp of the colon simulating malignancy.

    abstract::The authors report an inflammatory fibroid polyp of the colon which simulated a tumor on the air-contrast barium-enema examination. Histological evaluation revealed the inflammatory nature of the polyp. These rare lesions can be radiographically indistinguishable from primary colon carcinoma. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6611950

    authors: Ferin P,Skucas J

    更新日期:1983-10-01 00:00:00

  • The choice of sedation for computed tomography in children: a prospective evaluation.

    abstract::A prospective study of 582 pediatric cranial computed tomographic (CT) examinations was made in order to determine the efficacy and safety of two sedation regimens and general anesthesia. Two hundred seventy-nine outpatients were randomly given oral chloral hydrate (80 mg/kg) or an intramuscular preparation composed o...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.143.2.7071350

    authors: Thompson JR,Schneider S,Ashwal S,Holden BS,Hinshaw DB Jr,Hasso AN

    更新日期:1982-05-01 00:00:00

  • Barium enema examination using a remote controlled positive and negative contrast media inflator.

    abstract::In a series of 30 patients, barium enema examination of the colon was performed via a remote controlled air and contrast media inflator. With this apparatus, introduction and elimination of air and barium into the colon can be accomplished at a freely adjustable rate of injection by remote control. Fluoroscopy time is...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.2.533

    authors: Hisamichi S,Masuda Y,Shirane A,Sugawara N,Gomi T,Oshiba S

    更新日期:1977-11-01 00:00:00

  • Type II endoleak after endoaortic graft implantation: diagnosis with helical CT arteriography.

    abstract:PURPOSE:To retrospectively assess endoleak shapes and locations within aneurysms to differentiate type II from type I and type III endoleaks. MATERIALS AND METHODS:The institutional review board granted an exemption for this HIPAA-compliant study; patient informed consent was not required. A retrospective review of ar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2403051013

    authors: Chernyak V,Rozenblit AM,Patlas M,Cynamon J,Ricci ZJ,Laks MP,Veith FJ

    更新日期:2006-09-01 00:00:00

  • The relationship of patient waiting time to capacity and utilization in emergency room radiology.

    abstract::The relationship between patient waiting time and capacity and utilization is quantified. By deciding upon the average acceptable and maximum allowable waiting times, the required capacity and resulting utilization rate are fixed. The data needed for analysis include waiting time, patient volume, time required for spe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/130.3.637

    authors: Rhea JT,St Germain RP

    更新日期:1979-03-01 00:00:00

  • Epinephrine enhanced renal angiography in the diagnosis of hamartoma (angiomyolipoma): a reevaluation.

    abstract::The vlue of epinephrine enhanced angiography in the preoperative distinction of isolated hamartoma (angiomyolipoma without stigma of tuberous sclerosis) from hypernephroma has been largely discounted in the past. The authors performed this procedure in 6 patients (4 with isolated hamartoma and 2 with tuberous sclerosi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.1.61

    authors: Jander HP,Tonkin IL

    更新日期:1979-07-01 00:00:00

  • Recurrent symptoms after shoulder instability repair: direct MR arthrographic assessment--correlation with second-look surgical evaluation.

    abstract:PURPOSE:To retrospectively determine the accuracy of direct magnetic resonance (MR) arthrography of the shoulder in patients with recurrent or residual signs and/or symptoms of instability after prior instability repair, with surgical findings as the reference standard. MATERIALS AND METHODS:After institutional ethics...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2453061329

    authors: Probyn LJ,White LM,Salonen DC,Tomlinson G,Boynton EL

    更新日期:2007-12-01 00:00:00

  • Volume and planar gated cardiac magnetic resonance imaging: a correlative study of normal anatomy with thallium-201 SPECT and cadaver sections.

    abstract::Magnetic resonance (MR) gated cardiac imaging was performed in ten subjects using a prototype 0.15-T resistive magnet imaging system. Volume and planar imaging techniques utilizing saturation recovery, proton Tl-weighted relaxation time pulse sequences produced images of the heart and great vessels with exquisite anat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.1.6606190

    authors: Go RT,MacIntyre WJ,Yeung HN,Kramer DM,Geisinger M,Chilcote W,George C,O'Donnell JK,Moodie DS,Meaney TF

    更新日期:1984-01-01 00:00:00

  • Acute pancreatitis: imaging utilization practices in an urban teaching hospital--analysis of trends with assessment of independent predictors in correlation with patient outcomes.

    abstract:PURPOSE:To evaluate imaging utilization trends in patients with acute pancreatitis (AP) and to assess independent predictors of radiology usage in relation to patient outcomes. MATERIALS AND METHODS:Institutional review board approval was obtained for this HIPAA-compliant study; written informed consent was waived. AP...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100320

    authors: Mortele KJ,Ip IK,Wu BU,Conwell DL,Banks PA,Khorasani R

    更新日期:2011-01-01 00:00:00

  • Echotexture of peripheral nerves: correlation between US and histologic findings and criteria to differentiate tendons.

    abstract:PURPOSE:To correlate the histologic structure and echotexture of peripheral nerves and verify if ultrasound (US) findings can be used to differentiate nerve from tendon. MATERIALS AND METHODS:In an in vitro study, the echotexture of normal peripheral nerves was correlated with the histologic findings. In an in vivo st...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.1.7568840

    authors: Silvestri E,Martinoli C,Derchi LE,Bertolotto M,Chiaramondia M,Rosenberg I

    更新日期:1995-10-01 00:00:00

  • Perivascular color artifact: pathologic significance and appearance on color Doppler US images.

    abstract::A distinctive type of artifactual extravascular assignment of color was identified in 49 color Doppler ultrasound (US) examinations in 43 patients. This artifact appeared as a random localized mixture of red and blue assigned to perivascular soft tissues; the artifact varied with the cardiac cycle, being most prominen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.3.2655000

    authors: Middleton WD,Erickson S,Melson GL

    更新日期:1989-06-01 00:00:00

  • Adnexal masses: transvaginal US and gadolinium-enhanced MR imaging assessment of intratumoral structure.

    abstract:PURPOSE:To evaluate the accuracy of transvaginal ultrasound (US) and gadolinium-enhanced magnetic resonance (MR) imaging in the assessment of the intratumoral structure of an adnexal mass. MATERIALS AND METHODS:The population comprised 82 patients with an adnexal mass who underwent both transvaginal US and gadolinium-...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.1.8539360

    authors: Komatsu T,Konishi I,Mandai M,Togashi K,Kawakami S,Konishi J,Mori T

    更新日期:1996-01-01 00:00:00

  • Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

    abstract:PURPOSE:To determine conversion factors for the new International Commission on Radiological Protection (ICRP) publication 103 recommendations for adult and pediatric patients and to compare the effective doses derived from Monte Carlo calculations with those derived from dose-length product (DLP) for different body re...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100047

    authors: Deak PD,Smal Y,Kalender WA

    更新日期:2010-10-01 00:00:00

  • Application of image-guided surface coil P-31 MR spectroscopy to human liver, heart, and kidney.

    abstract::Localized phosphorus-31 magnetic resonance (MR) spectroscopy in humans has previously been accomplished with surface coils by means of depth-resolved surface coil spectroscopy or rotating frame experiments, in which the extent of tissue sampled critically depends on surface coil placement. The authors' goal was to mod...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.2.3051120

    authors: Matson GB,Twieg DB,Karczmar GS,Lawry TJ,Gober JR,Valenza M,Boska MD,Weiner MW

    更新日期:1988-11-01 00:00:00

  • Skull-base tumors: ethanol embolization of the cavernous carotid artery.

    abstract::Tumors of the skull base frequently have some blood supply from cavernous branches of the internal carotid artery (ICA). Preoperative embolization of such pedicles can expedite the subsequently performed surgery. Sometimes, however, the tumor vessels are multiple and very small so selective catheterizations are not po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.181.3.1947090

    authors: Jungreis CA

    更新日期:1991-12-01 00:00:00

  • Endovascular Interventions for Acute and Chronic Lower Extremity Deep Venous Disease: State of the Art.

    abstract::The societal and individual burden caused by acute and chronic lower extremity venous disease is considerable. In the past several decades, minimally invasive endovascular interventions have been developed to reduce thrombus burden in the setting of acute deep venous thrombosis to prevent both short- and long-term mor...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015132603

    authors: Sista AK,Vedantham S,Kaufman JA,Madoff DC

    更新日期:2015-07-01 00:00:00

  • Amiodarone pulmonary toxicity: CT findings in symptomatic patients.

    abstract::The computed tomographic (CT) chest scans of 11 patients who developed respiratory or constitutional symptoms while receiving amiodarone therapy were reviewed. CT findings indicative of significant amiodarone exposure included (a) high-attenuation parenchymal-pleural lesions in eight of the 11 patients (73%), and (b) ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.1.2399310

    authors: Kuhlman JE,Teigen C,Ren H,Hruban RH,Hutchins GM,Fishman EK

    更新日期:1990-10-01 00:00:00

  • Nonpalpable breast lesion localization: limited efficacy of sonography.

    abstract::We attempted to use hand-held, high-resolution breast sonography to localize for biopsy 11 solid, nonpalpable lesions detected by mammography. Using sonography, we identified and localized only one of four lesions presenting as poorly defined masses and only one of seven lesions presenting as clusters of tiny calcific...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.3890010

    authors: Weber WN,Sickles EA,Callen PW,Filly RA

    更新日期:1985-06-01 00:00:00

  • Linearity of exposure with indicated time and current for diagnostic radiography units.

    abstract::Quality control in diagnostic radiography begins with production of predictable exposures. The authors describe a technique which permits determination of the variation of mR/mAs for the entire diagnostic range of times and currents in only about 1 hour. The mR/mAs in newly installed units has been shown to vary by as...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.2.489

    authors: Starchman DE,Johnson RG,Howland WJ

    更新日期:1977-02-01 00:00:00

  • Complications of arthrography.

    abstract::Arthrography is considered extremely safe since reactions to intraarticular contrast media are rare. We have only seen one severe complication in the performance of more than 2,000 arthrographic procedures. To determine the incidence of complications, a questionnaire was sent to 84 radiologists experienced in arthrogr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001360

    authors: Newberg AH,Munn CS,Robbins AH

    更新日期:1985-06-01 00:00:00

  • Photographic method of recording radiation fields using the localizer light for illumination.

    abstract::By interposing a camera with a fish-eye lens between the collimator and the illuminated field, radiotherapy ports can be recorded using the localizer light for illumination. An acrylic mold of the camera was used to maintain alignment and immobilization during the necessarily long exposures. The authors consider this ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.3.801

    authors: Pantoja E,Frede T,Leininger V

    更新日期:1977-06-01 00:00:00

  • Cervical spine screening with CT in trauma patients: a cost-effectiveness analysis.

    abstract:PURPOSE:To investigate the cost-effectiveness of computed tomography (CT) relative to radiography for cervical spine screening in trauma patients. MATERIALS AND METHODS:A decision analysis model was constructed to compare the incremental cost-effectiveness of radiography and CT as primary cervical spine screening moda...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.212.1.r99jl08117

    authors: Blackmore CC,Ramsey SD,Mann FA,Deyo RA

    更新日期:1999-07-01 00:00:00

  • MR imaging-guided focused US ablation of breast cancer: histopathologic assessment of effectiveness-- initial experience.

    abstract:PURPOSE:To evaluate the effectiveness of noninvasive magnetic resonance (MR) imaging-guided focused ultrasonographic (US) ablation of breast carcinomas. MATERIALS AND METHODS:Before undergoing tumor resection, 12 patients with invasive breast carcinomas were treated with MR imaging-guided focused US ablation consistin...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2281012163

    authors: Gianfelice D,Khiat A,Amara M,Belblidia A,Boulanger Y

    更新日期:2003-06-01 00:00:00

  • Three-dimensional Deep Convolutional Neural Networks for Automated Myocardial Scar Quantification in Hypertrophic Cardiomyopathy: A Multicenter Multivendor Study.

    abstract::Background Cardiac MRI late gadolinium enhancement (LGE) scar volume is an important marker for outcome prediction in patients with hypertrophic cardiomyopathy (HCM); however, its clinical application is hindered by a lack of measurement standardization. Purpose To develop and evaluate a three-dimensional (3D) convolu...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2019190737

    authors: Fahmy AS,Neisius U,Chan RH,Rowin EJ,Manning WJ,Maron MS,Nezafat R

    更新日期:2020-01-01 00:00:00

  • Primary advanced and local recurrent head and neck tumors: effective management with interstitial thermal radiation therapy.

    abstract::Thirty-seven patients with 18 primary advanced or persistent, 16 local recurrent, and three local metastatic tumors of the head and neck were treated with a combination of interstitial low-dose iridium-192 radiation therapy and interstitial 915-MHz microwave hyperthermia supplemented by external radiation therapy. Twe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.1.2353100

    authors: Seegenschmiedt MH,Sauer R,Fietkau R,Karlsson UL,Brady LW

    更新日期:1990-07-01 00:00:00

  • Clinical significance of 99mtechnetium sulfur colloid accumulation in renal transplant patients.

    abstract::The accumulation of 99mtechnetium sulfur colloid (99mTcSC) was evaluated in 47 studies performed on 19 renal transplant patients by comparing its transplant activity to its bone marrow accumulation. There was a diagnosis of rejection of 21 of 22 studies (96.5%) in which marked transplant accumulation was noted. In 11 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.745

    authors: Kim YC,Massari PU,Brown ML,Thrall JH,Chang B,Keyes JW Jr

    更新日期:1977-09-01 00:00:00

  • Interactive real-time multiplanar CT imaging.

    abstract::A new software program provides the real-time display of high-resolution computed tomographic reformation in the axial, coronal, sagittal, or oblique views. The advantages of this new technique over the standard multiplanar format include (a) larger image display format, (b) reconstruction of entire dataset for each o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.1.2909110

    authors: Ney DR,Fishman EK,Magid D,Kuhlman JE

    更新日期:1989-01-01 00:00:00

  • Introducing the "golden oldies" of radiology.

    abstract::Online supplemental material is available for this article. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14142264

    authors: Kressel HY,Levine D

    更新日期:2015-01-01 00:00:00

  • Technical cost of radiologic examinations: analysis across imaging modalities.

    abstract:PURPOSE:To determine the individual technical costs of general diagnostic radiographic, ultrasonographic (US), computed tomographic (CT), magnetic resonance (MR) imaging, and scintigraphic examinations and interventional radiology. MATERIALS AND METHODS:The Radiology Cost and Productivity Benchmarking Study method of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.1.r00jl18269

    authors: Saini S,Seltzer SE,Bramson RT,Levine LA,Kelly P,Jordan PF,Chiango BF,Thrall JH

    更新日期:2000-07-01 00:00:00