Abstract:
:We attempted to use hand-held, high-resolution breast sonography to localize for biopsy 11 solid, nonpalpable lesions detected by mammography. Using sonography, we identified and localized only one of four lesions presenting as poorly defined masses and only one of seven lesions presenting as clusters of tiny calcifications. This 18% rate of success is too low to justify the use of sonography for all patients undergoing needle localization. Mammography remains the procedure of choice for localizing solid, nonpalpable breast masses and clustered calcifications.
journal_name
Radiologyjournal_title
Radiologyauthors
Weber WN,Sickles EA,Callen PW,Filly RAdoi
10.1148/radiology.155.3.3890010subject
Has Abstractpub_date
1985-06-01 00:00:00pages
783-4issue
3eissn
0033-8419issn
1527-1315journal_volume
155pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract:PURPOSE:To prospectively evaluate accuracy and predictive values of Doppler ultrasonographic (US) measurement of portal blood velocity (PBV) and splenic pulsatility index (SPI) in diagnosis of clinically relevant acute rejection in patients with clinicobiochemical hepatic dysfunction after orthotopic liver transplantat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2352040506
更新日期:2005-05-01 00:00:00
abstract:PURPOSE:To determine the radiation dose to radiologists who perform computed tomographic (CT) fluoroscopic interventional procedures by using a quick-check method and a low-milliampere technique. MATERIALS AND METHODS:Two hundred twenty CT fluoroscopy--guided interventional procedures were performed in 189 patients. P...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.220.1.r01jl29161
更新日期:2001-07-01 00:00:00
abstract::Lymphangiomas are rare, benign tumors which may become opacified during lymphography and may be confused with malignant lymph node disease. A case is reported in which lymphography showed focal collections of contrast material retained for several days in dilated lymphatic spaces which initially simulated metastatic d...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/115.2.355
更新日期:1975-05-01 00:00:00
abstract::The radiological features of absence of a pulmonary artery are often characteristic enough to allow a diagnosis based on the plain radiograph. They include a small hemithorax, ipsilateral displacement of the mediastinum, absence of the corresponding pulmonary artery, and reticular parenchymal densities, generally attr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/132.2.281
更新日期:1979-08-01 00:00:00
abstract::Steeple-shaped shadows adjacent to the diaphragm are common in upper lobe collapse due to a variety of causes. They call attention to upper lobe collapse and should not be considered indicative of intrinsic lower lobe abnormality. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.3.7355230
更新日期:1980-03-01 00:00:00
abstract::A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined wit...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.208.3.9722850
更新日期:1998-09-01 00:00:00
abstract::A new tray has been designed for use during procedures involving needles and other sharp objects. The tray includes a foam adhesive pad, marked into 10 sections, into which the sharp objects can be placed point first. After the procedure, the objects can be safely withdrawn by their handles and then discarded. The tra...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.173.1.2781020
更新日期:1989-10-01 00:00:00
abstract:PURPOSE:To evaluate multi- and single-detector row computed tomographic (CT) depiction of anatomic landmarks of temporal bone. MATERIALS AND METHODS:Institutional review board approval and written informed consent were obtained. In 50 temporal bones, transverse and coronal single-detector row CT images were compared w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2351020895
更新日期:2005-04-01 00:00:00
abstract:PURPOSE:To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies. MATERIALS AND METHODS:A search strategy in MEDLINE and citati...
journal_title:Radiology
pub_type: 杂志文章,meta分析
doi:10.1148/radiology.217.1.r00oc11105
更新日期:2000-10-01 00:00:00
abstract::The safety and long-term effectiveness of fluoroscopically guided balloon dilation for corrosive esophageal stricture was evaluated in 22 patients with a follow-up period of more than 1 year (range, 13-52 months). The average interval between corrosive agent ingestion and initial balloon dilation was 18 years (range, ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.184.2.1620830
更新日期:1992-08-01 00:00:00
abstract:PURPOSE:To determine if local application of L-arginine, r-hirudin, or molsidomine significantly reduces restenosis after balloon angioplasty in stenotic rabbit iliac arteries. MATERIALS AND METHODS:Thirty-one male cholesterol-fed New Zealand white rabbits underwent balloon dilation of both common iliac arteries to in...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.219.3.r01jn27716
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To test three-dimensional (3D), navigator-echo magnetic resonance (MR) coronary angiography in detecting stenoses of the coronary arteries. MATERIALS AND METHODS:Forty-two patients (age range, 50-79 years) underwent MR coronary angiography (1.5 T). A navigator-echo sequence was used. Two or three 15% overlappe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.214.3.r00mr01808
更新日期:2000-03-01 00:00:00
abstract::The authors retrospectively evaluated 12 patients with congenital (neonatal) neuroblastoma to assess the utility of newer imaging modalities. Findings at prenatal ultrasound (US), performed in four patients, were nonspecific (hydramnios and hydrops fetalis) in two and consistent with a suprarenal mass (one solid, one ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.175.2.2183280
更新日期:1990-05-01 00:00:00
abstract::Fifty-one pediatric patients (range, 1 mo. to 16 yr.), all of whom had normal clinical findings and laboratory data pertaining to the gallbladder and biliary tract, were examined by ultrasound. Scans showed a gradual increase in the size of the gallbladder with age; only one patient had a gallbladder diameter greater ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.4.7111740
更新日期:1982-09-01 00:00:00
abstract::The effect of 5-thio-D-glucose on the viability and radiosensitivity of P815-X2 mouse mastocytoma cells was studied in vitro. By itself, this compound is specifically cytotoxic toward hypoxic cells; moreover, it sensitizes hypoxic cells to irradiation while it protects aerobic cells from radiation damage. These featur...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/123.1.201
更新日期:1977-04-01 00:00:00
abstract:PURPOSE:To investigate the diagnostic value of technetium 99m-labeled human serum albumin (HSA) scintigraphy in a group of patients suspected of having protein-losing enteropathy (PLE). MATERIALS AND METHODS:After intravenous injection of 740 MBq of freshly prepared (99m)Tc HSA, serial images of the abdomen were obtai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.219.1.r01ap2986
更新日期:2001-04-01 00:00:00
abstract:PURPOSE:To investigate how changes in kilovolt peak and milliampere second settings, and patient weight affect transmitted x-ray energy fluence and the image contrast-to-noise ratio (CNR) at abdominal computed tomography (CT). MATERIALS AND METHODS:Cylinders of water were used as patient models, and x-ray spectra, inc...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.217.2.r00nv35430
更新日期:2000-11-01 00:00:00
abstract::Radionuclide findings in a case of cavernous sinus occlusion by an intracavernous aneurysm are described. A brain image obtained 10 minutes after injection of 99Tc pertechnetate shows diminished activity in the area of the right cavernous sinus and increased activity in the area of the right sylvian veins; these are a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.1.113
更新日期:1976-01-01 00:00:00
abstract:PURPOSE:To examine relationships between brain white matter hyperintensities depicted at magnetic resonance (MR) imaging and performance on neuropsychologic tests in community-dwelling elderly adults. MATERIALS AND METHODS:The 1921 Aberdeen Birth Cohort is a subsample of survivors of the Scottish Mental Survey of 1932...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2211010086
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:To evaluate the incidence of postoperative complications in liver donors and the efficacy of interventional management for treating these complications. MATERIALS AND METHODS:The study included 386 consecutive donors: 219 donors underwent right lobectomy or segmentectomy and 167 donors underwent left lobectomy...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2302021318
更新日期:2004-02-01 00:00:00
abstract::Histories, physical examinations and 99mTc-pertechnetate imaging were used to evaluate 1,452 persons who had had x-ray therapy to the neck region for benign conditions 18 to 35 years previously. Thyroid abnormalities were found in 301 patients (21%) and thyroid malignancy was found in 29% of 193 patients with abnormal...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/15.3.653
更新日期:1975-06-01 00:00:00
abstract:PURPOSE:To evaluate the prognostic value of volumetric computed tomography (CT) for therapy control in patients treated with repeated transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Eighty-five patients with histologically proved HCC underwent 182 TACE procedures with 5...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.214.2.r00fe06349
更新日期:2000-02-01 00:00:00
abstract::Ten ureteral strictures that developed in nine patients after renal transplantation were managed with balloon catheter dilation and placement of a ureteral stent. Four strictures were successfully dilated (40%), with a follow-up of 15-42 months (mean, 29 months). Comparison of these cases with the six cases of unsucce...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.186.3.8430180
更新日期:1993-03-01 00:00:00
abstract:PURPOSE:To quantify inter- and intrascanner conformity in computed tomographic (CT) densitometry of the lungs. MATERIALS AND METHODS:With six scanners from four manufacturers, a lung densitometry protocol with several variations was applied for performance comparison. Phantoms included water, air, and a humanoid thora...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.3.7480750
更新日期:1995-12-01 00:00:00
abstract::Two patients with superior vena cava syndrome (SVCS) associated with massive thrombosis were treated by means of local thrombolytic therapy and placement of modified Gianturco expandable wire stents. Treatment resulted in complete resolution of the SVCS symptoms. The combination of local thrombolytic therapy and stent...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.167.3.3363130
更新日期:1988-06-01 00:00:00
abstract:PURPOSE:To retrospectively compare the kinetic and morphologic characteristics of pure ductal carcinoma in situ (DCIS) lesions depicted on dynamic contrast material-enhanced magnetic resonance (MR) images with the nuclear grade and conventional mammographic appearance of these lesions. MATERIALS AND METHODS:This HIPAA...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2453062061
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:To compare the diagnostic usefulness of three-dimensional (3D) stereotaxic surface projection (SSP) with that of standard transaxial display in brain positron emission tomography (PET) in Alzheimer disease (AD). MATERIALS AND METHODS:Standard transaxial section display and 3D-SSP PET image sets obtained after ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.198.3.8628880
更新日期:1996-03-01 00:00:00
abstract:PURPOSE:To determine the computed tomographic (CT) appearance of the normal modiolus and the pathologic alteration in patients with a large vestibular aqueduct and an otherwise normal-appearing cochlea. MATERIALS AND METHODS:Temporal bone CT studies obtained before and after a major upgrade of CT capability in 1992 we...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.204.1.9205250
更新日期:1997-07-01 00:00:00
abstract::When fast, nondynamic scanning techniques are used in combination with adequate intravenous injection of contrast material, good-quality images of the pulmonary artery (PA) can be obtained with routine computed tomography (CT). The purpose of this study was to evaluate PA filling defects detected on these CT scans. Tw...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.3.8351360
更新日期:1993-09-01 00:00:00
abstract::Multiphasic examinations of 153 gastric abnormalities observed radiologically and endoscopically were reviewed to determine the efficacy of four radiologic techniques and of several common combinations of these techniques for examining the stomach. There were 68 gastric ulcers, 12 ulcer scars, 44 cases of gastritis in...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.162.3.3809500
更新日期:1987-03-01 00:00:00