Nonpalpable breast lesion localization: limited efficacy of sonography.

Abstract:

:We attempted to use hand-held, high-resolution breast sonography to localize for biopsy 11 solid, nonpalpable lesions detected by mammography. Using sonography, we identified and localized only one of four lesions presenting as poorly defined masses and only one of seven lesions presenting as clusters of tiny calcifications. This 18% rate of success is too low to justify the use of sonography for all patients undergoing needle localization. Mammography remains the procedure of choice for localizing solid, nonpalpable breast masses and clustered calcifications.

journal_name

Radiology

journal_title

Radiology

authors

Weber WN,Sickles EA,Callen PW,Filly RA

doi

10.1148/radiology.155.3.3890010

subject

Has Abstract

pub_date

1985-06-01 00:00:00

pages

783-4

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

155

pub_type

杂志文章
  • Acute liver rejection: accuracy and predictive values of doppler US measurements--initial experience.

    abstract:PURPOSE:To prospectively evaluate accuracy and predictive values of Doppler ultrasonographic (US) measurement of portal blood velocity (PBV) and splenic pulsatility index (SPI) in diagnosis of clinically relevant acute rejection in patients with clinicobiochemical hepatic dysfunction after orthotopic liver transplantat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2352040506

    authors: Bolognesi M,Sacerdoti D,Mescoli C,Nava V,Bombonato G,Merkel C,Merenda R,Angeli P,Rugge M,Gatta A

    更新日期:2005-05-01 00:00:00

  • CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.

    abstract:PURPOSE:To determine the radiation dose to radiologists who perform computed tomographic (CT) fluoroscopic interventional procedures by using a quick-check method and a low-milliampere technique. MATERIALS AND METHODS:Two hundred twenty CT fluoroscopy--guided interventional procedures were performed in 189 patients. P...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.220.1.r01jl29161

    authors: Paulson EK,Sheafor DH,Enterline DS,McAdams HP,Yoshizumi TT

    更新日期:2001-07-01 00:00:00

  • Lymphographic Demonstration of a Retroperitoneal Lymphangioma.

    abstract::Lymphangiomas are rare, benign tumors which may become opacified during lymphography and may be confused with malignant lymph node disease. A case is reported in which lymphography showed focal collections of contrast material retained for several days in dilated lymphatic spaces which initially simulated metastatic d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.2.355

    authors: Castellino RA,Finkelstein S

    更新日期:1975-05-01 00:00:00

  • Pleural telangiectasia and absence of a pulmonary artery.

    abstract::The radiological features of absence of a pulmonary artery are often characteristic enough to allow a diagnosis based on the plain radiograph. They include a small hemithorax, ipsilateral displacement of the mediastinum, absence of the corresponding pulmonary artery, and reticular parenchymal densities, generally attr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.281

    authors: Kleinman PK

    更新日期:1979-08-01 00:00:00

  • The juxtaphrenic peak in upper lobe collapse.

    abstract::Steeple-shaped shadows adjacent to the diaphragm are common in upper lobe collapse due to a variety of causes. They call attention to upper lobe collapse and should not be considered indicative of intrinsic lower lobe abnormality. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.3.7355230

    authors: Kattan KR,Eyler WR,Felson B

    更新日期:1980-03-01 00:00:00

  • Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector.

    abstract::A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined wit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.3.9722850

    authors: Arfelli F,Bonvicini V,Bravin A,Cantatore G,Castelli E,Dalla Palma L,Di Michiel M,Longo R,Olivo A,Pani S,Pontoni D,Poropat P,Prest M,Rashevsky A,Tromba G,Vacchi A

    更新日期:1998-09-01 00:00:00

  • New universal precaution aspiration tray.

    abstract::A new tray has been designed for use during procedures involving needles and other sharp objects. The tray includes a foam adhesive pad, marked into 10 sections, into which the sharp objects can be placed point first. After the procedure, the objects can be safely withdrawn by their handles and then discarded. The tra...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.1.2781020

    authors: Mueller PR,Silverman SG,Tung G,Brink JA,Cardenosa G,Saini S,Forman BH,Hahn PF

    更新日期:1989-10-01 00:00:00

  • CT of the normal temporal bone: comparison of multi- and single-detector row CT.

    abstract:PURPOSE:To evaluate multi- and single-detector row computed tomographic (CT) depiction of anatomic landmarks of temporal bone. MATERIALS AND METHODS:Institutional review board approval and written informed consent were obtained. In 50 temporal bones, transverse and coronal single-detector row CT images were compared w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2351020895

    authors: Jäger L,Bonell H,Liebl M,Srivastav S,Arbusow V,Hempel M,Reiser M

    更新日期:2005-04-01 00:00:00

  • Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography.

    abstract:PURPOSE:To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies. MATERIALS AND METHODS:A search strategy in MEDLINE and citati...

    journal_title:Radiology

    pub_type: 杂志文章,meta分析

    doi:10.1148/radiology.217.1.r00oc11105

    authors: Nelemans PJ,Leiner T,de Vet HC,van Engelshoven JM

    更新日期:2000-10-01 00:00:00

  • Corrosive esophageal stricture: safety and effectiveness of balloon dilation.

    abstract::The safety and long-term effectiveness of fluoroscopically guided balloon dilation for corrosive esophageal stricture was evaluated in 22 patients with a follow-up period of more than 1 year (range, 13-52 months). The average interval between corrosive agent ingestion and initial balloon dilation was 18 years (range, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.184.2.1620830

    authors: Song HY,Han YM,Kim HN,Kim CS,Choi KC

    更新日期:1992-08-01 00:00:00

  • Comparative trial of local pharmacotherapy with L-arginine, r-hirudin, and molsidomine to reduce restenosis after balloon angioplasty of stenotic rabbit iliac arteries.

    abstract:PURPOSE:To determine if local application of L-arginine, r-hirudin, or molsidomine significantly reduces restenosis after balloon angioplasty in stenotic rabbit iliac arteries. MATERIALS AND METHODS:Thirty-one male cholesterol-fed New Zealand white rabbits underwent balloon dilation of both common iliac arteries to in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.3.r01jn27716

    authors: Kalinowski M,Alfke H,Bergen S,Klose KJ,Barry JJ,Wagner HJ

    更新日期:2001-06-01 00:00:00

  • Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference.

    abstract:PURPOSE:To test three-dimensional (3D), navigator-echo magnetic resonance (MR) coronary angiography in detecting stenoses of the coronary arteries. MATERIALS AND METHODS:Forty-two patients (age range, 50-79 years) underwent MR coronary angiography (1.5 T). A navigator-echo sequence was used. Two or three 15% overlappe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.3.r00mr01808

    authors: Sardanelli F,Molinari G,Zandrino F,Balbi M

    更新日期:2000-03-01 00:00:00

  • Congenital neuroblastoma: evaluation with multimodality imaging.

    abstract::The authors retrospectively evaluated 12 patients with congenital (neonatal) neuroblastoma to assess the utility of newer imaging modalities. Findings at prenatal ultrasound (US), performed in four patients, were nonspecific (hydramnios and hydrops fetalis) in two and consistent with a suprarenal mass (one solid, one ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.2.2183280

    authors: Forman HP,Leonidas JC,Berdon WE,Slovis TL,Wood BP,Samudrala R

    更新日期:1990-05-01 00:00:00

  • Sonography of the normal pediatric gallbladder and biliary tract.

    abstract::Fifty-one pediatric patients (range, 1 mo. to 16 yr.), all of whom had normal clinical findings and laboratory data pertaining to the gallbladder and biliary tract, were examined by ultrasound. Scans showed a gradual increase in the size of the gallbladder with age; only one patient had a gallbladder diameter greater ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.4.7111740

    authors: McGahan JP,Phillips HE,Cox KL

    更新日期:1982-09-01 00:00:00

  • Cytotoxic and radiosensitizing effects of 5-thio-D-glucose on hypoxic cells.

    abstract::The effect of 5-thio-D-glucose on the viability and radiosensitivity of P815-X2 mouse mastocytoma cells was studied in vitro. By itself, this compound is specifically cytotoxic toward hypoxic cells; moreover, it sensitizes hypoxic cells to irradiation while it protects aerobic cells from radiation damage. These featur...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.1.201

    authors: Song CW,Clement JJ,Levitt SH

    更新日期:1977-04-01 00:00:00

  • Protein-losing enteropathy: diagnosis with (99m)Tc-labeled human serum albumin scintigraphy.

    abstract:PURPOSE:To investigate the diagnostic value of technetium 99m-labeled human serum albumin (HSA) scintigraphy in a group of patients suspected of having protein-losing enteropathy (PLE). MATERIALS AND METHODS:After intravenous injection of 740 MBq of freshly prepared (99m)Tc HSA, serial images of the abdomen were obtai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.1.r01ap2986

    authors: Chiu NT,Lee BF,Hwang SJ,Chang JM,Liu GC,Yu HS

    更新日期:2001-04-01 00:00:00

  • Technique factors and image quality as functions of patient weight at abdominal CT.

    abstract:PURPOSE:To investigate how changes in kilovolt peak and milliampere second settings, and patient weight affect transmitted x-ray energy fluence and the image contrast-to-noise ratio (CNR) at abdominal computed tomography (CT). MATERIALS AND METHODS:Cylinders of water were used as patient models, and x-ray spectra, inc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.2.r00nv35430

    authors: Huda W,Scalzetti EM,Levin G

    更新日期:2000-11-01 00:00:00

  • Brain image manifestation in the patient with cavernous sinus occlusion.

    abstract::Radionuclide findings in a case of cavernous sinus occlusion by an intracavernous aneurysm are described. A brain image obtained 10 minutes after injection of 99Tc pertechnetate shows diminished activity in the area of the right cavernous sinus and increased activity in the area of the right sylvian veins; these are a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.1.113

    authors: Hahn FJ,Schapiro RL

    更新日期:1976-01-01 00:00:00

  • Neuropsychologic correlates of brain white matter lesions depicted on MR images: 1921 Aberdeen Birth Cohort.

    abstract:PURPOSE:To examine relationships between brain white matter hyperintensities depicted at magnetic resonance (MR) imaging and performance on neuropsychologic tests in community-dwelling elderly adults. MATERIALS AND METHODS:The 1921 Aberdeen Birth Cohort is a subsample of survivors of the Scottish Mental Survey of 1932...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2211010086

    authors: Leaper SA,Murray AD,Lemmon HA,Staff RT,Deary IJ,Crawford JR,Whalley LJ

    更新日期:2001-10-01 00:00:00

  • Living donor liver transplantation: complications in donors and interventional management.

    abstract:PURPOSE:To evaluate the incidence of postoperative complications in liver donors and the efficacy of interventional management for treating these complications. MATERIALS AND METHODS:The study included 386 consecutive donors: 219 donors underwent right lobectomy or segmentectomy and 167 donors underwent left lobectomy...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2302021318

    authors: Lee SY,Ko GY,Gwon DI,Song HY,Lee SG,Yoon HK,Sung KB

    更新日期:2004-02-01 00:00:00

  • 99mTc-pertechnetate thyroid scintigraphy in patients predisposed to thyroid neoplasms by prior radiotherapy to the head and neck.

    abstract::Histories, physical examinations and 99mTc-pertechnetate imaging were used to evaluate 1,452 persons who had had x-ray therapy to the neck region for benign conditions 18 to 35 years previously. Thyroid abnormalities were found in 301 patients (21%) and thyroid malignancy was found in 29% of 193 patients with abnormal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.653

    authors: Arnold J,Pinsky S,Ryo UY,Frohman L,Schneider A,Favus M,Stachura M,Arnold M,Colman M

    更新日期:1975-06-01 00:00:00

  • Transarterial chemoembolization for hepatocellular carcinoma: volumetric and morphologic CT criteria for assessment of prognosis and therapeutic success-results from a liver transplantation center.

    abstract:PURPOSE:To evaluate the prognostic value of volumetric computed tomography (CT) for therapy control in patients treated with repeated transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Eighty-five patients with histologically proved HCC underwent 182 TACE procedures with 5...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.2.r00fe06349

    authors: Vogl TJ,Trapp M,Schroeder H,Mack M,Schuster A,Schmitt J,Neuhaus P,Felix R

    更新日期:2000-02-01 00:00:00

  • Balloon dilation of ureteral strictures after renal transplantation.

    abstract::Ten ureteral strictures that developed in nine patients after renal transplantation were managed with balloon catheter dilation and placement of a ureteral stent. Four strictures were successfully dilated (40%), with a follow-up of 15-42 months (mean, 29 months). Comparison of these cases with the six cases of unsucce...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.3.8430180

    authors: Kim JC,Banner MP,Ramchandani P,Grossman RA,Pollack HM

    更新日期:1993-03-01 00:00:00

  • Scanner conformity in CT densitometry of the lungs.

    abstract:PURPOSE:To quantify inter- and intrascanner conformity in computed tomographic (CT) densitometry of the lungs. MATERIALS AND METHODS:With six scanners from four manufacturers, a lung densitometry protocol with several variations was applied for performance comparison. Phantoms included water, air, and a humanoid thora...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.3.7480750

    authors: Kemerink GJ,Lamers RJ,Thelissen GR,van Engelshoven JM

    更新日期:1995-12-01 00:00:00

  • Superior vena cava syndrome associated with massive thrombosis: treatment with expandable wire stents.

    abstract::Two patients with superior vena cava syndrome (SVCS) associated with massive thrombosis were treated by means of local thrombolytic therapy and placement of modified Gianturco expandable wire stents. Treatment resulted in complete resolution of the SVCS symptoms. The combination of local thrombolytic therapy and stent...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.3.3363130

    authors: Putnam JS,Uchida BT,Antonovic R,Rösch J

    更新日期:1988-06-01 00:00:00

  • Pure ductal carcinoma in situ: kinetic and morphologic MR characteristics compared with mammographic appearance and nuclear grade.

    abstract:PURPOSE:To retrospectively compare the kinetic and morphologic characteristics of pure ductal carcinoma in situ (DCIS) lesions depicted on dynamic contrast material-enhanced magnetic resonance (MR) images with the nuclear grade and conventional mammographic appearance of these lesions. MATERIALS AND METHODS:This HIPAA...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2453062061

    authors: Jansen SA,Newstead GM,Abe H,Shimauchi A,Schmidt RA,Karczmar GS

    更新日期:2007-12-01 00:00:00

  • Alzheimer disease: improved visual interpretation of PET images by using three-dimensional stereotaxic surface projections.

    abstract:PURPOSE:To compare the diagnostic usefulness of three-dimensional (3D) stereotaxic surface projection (SSP) with that of standard transaxial display in brain positron emission tomography (PET) in Alzheimer disease (AD). MATERIALS AND METHODS:Standard transaxial section display and 3D-SSP PET image sets obtained after ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.3.8628880

    authors: Burdette JH,Minoshima S,Vander Borght T,Tran DD,Kuhl DE

    更新日期:1996-03-01 00:00:00

  • Normal modiolus: CT appearance in patients with a large vestibular aqueduct.

    abstract:PURPOSE:To determine the computed tomographic (CT) appearance of the normal modiolus and the pathologic alteration in patients with a large vestibular aqueduct and an otherwise normal-appearing cochlea. MATERIALS AND METHODS:Temporal bone CT studies obtained before and after a major upgrade of CT capability in 1992 we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.1.9205250

    authors: Lemmerling MM,Mancuso AA,Antonelli PJ,Kubilis PS

    更新日期:1997-07-01 00:00:00

  • Detection of unsuspected central pulmonary embolism with conventional contrast-enhanced CT.

    abstract::When fast, nondynamic scanning techniques are used in combination with adequate intravenous injection of contrast material, good-quality images of the pulmonary artery (PA) can be obtained with routine computed tomography (CT). The purpose of this study was to evaluate PA filling defects detected on these CT scans. Tw...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351360

    authors: Verschakelen JA,Vanwijck E,Bogaert J,Baert AL

    更新日期:1993-09-01 00:00:00

  • Multiphasic examinations of the stomach: efficacy of individual techniques and combinations of techniques in detecting 153 lesions.

    abstract::Multiphasic examinations of 153 gastric abnormalities observed radiologically and endoscopically were reviewed to determine the efficacy of four radiologic techniques and of several common combinations of these techniques for examining the stomach. There were 68 gastric ulcers, 12 ulcer scars, 44 cases of gastritis in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.3.3809500

    authors: Gelfand DW,Chen YM,Ott DJ

    更新日期:1987-03-01 00:00:00